project rendering drawing index
Post on 31-Dec-2021
4 Views
Preview:
TRANSCRIPT
PROJECT TEAM:
ARCHITECT:CLIENT:
Architecture • Planning • Interiors • Preservation • Urban Design
www.arkinetics.com
architects + urbanists
STRUCTURAL ENGINEER:
2012 West 25th St., Suite 200Cleveland, OH 44113
P: 216. 227. 8505F: 216. 227. 8570
MECHANICAL / ELECTRICAL ENGINEER:
2012 West 25th St., Suite 200Cleveland, OH 44113
P: 216. 227. 8505F: 216. 227. 8570
MECHANICAL / ELECTRICAL ENGINEER:
2012 West 25th St., Suite 200Cleveland, OH 44113
P: 216. 227. 8505F: 216. 227. 8570
ANCHOR BOLTAIR CONDITIONINGACOUSTIC(AL)ACOUSTICAL CEILING TILEADJACENTABOVE FINISH FLOORALTERNATEALUMINUMANODIZEDAPPROXIMATEARCHITECT(URAL)AUTOMATIC
BOARDBETWEENBUILDINGBLOCK(ING)BULKHEADBEAMBOTTOMBRIDGINGBEARINGBRICKBASEMENTBUILT-UP ROOFING
CENTER TO CENTERCABINETCADMIUMCATCH BASINCEMENTCENTER LINECUBIC FEET PER MINUTECORNER GUARDCAST IRONCONTROL JOINTCEILINGCLOSETCLEARCONTRACT LIMIT LINECOUNTERCERAMIC MOSAIC TILECONCRETE MASONRY UNITCASED OPENING/CLEAN OUT
ABA/CACOUSACTADJAFFALTALUMANODAPPROXARCHAUTO
BDBETWBLDGBLKBLKHDBMBOTBRDGBRGBRKBSMTBUR
C/CCAB'TCADCBCEMCL orCFMCGCICJCLGCLCLRCLLCNTRCMTCMUCO
COLUMNCONCRETECONNECTIONCONSTRUCTIONCONTINUOUSCOORDINATECORRIDORCARPETCONCRETE SEALERCOURSECERAMIC TILECERAMIC TILE - PORCELAINCENTER
DEPTHDOUBLEDEGREESDEMOLITIONDRINKING FOUNTAINDIAMETERDIMENSIONDISPENSERDOWNDOORDOWN SPOUTDETAILDRAWINGDRAWERDRYWALL
EXPOSED STEELEXISTING TO REMAINEXISTING
FIRE ALARMFACE BRICKFAN COIL UNITFACE TO FACEFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISH
COLCONCCONNCONSTCONTCOORD/CORRCPTCSCSLRCTCTPCTR
DDBLDEGDEMODFDIADIMDISPDNDRDSDETDWGDWRDW
ESETREXIST
FAFBFCUF/FFDFDNFEFECFHCFIN
FLOORFLUORESCENTFACE OF MASONRYFIRE RESISTANTFIBERGLASS REINFORCED PANELSFIRE-RETARDANT TREATEDFIRE-RETARDANT TREATED WOODFEETFOOTINGFURRINGFIRE VALVE CABINETFABRIC WALLCOVERING
GAUGEGALVANIZEDGENERAL CONTRACTORGLASSGRADEGYPSUM BOARDGYPSUM WALL BOARD
HIGHHOSE BIBBHOLLOW COREHARDBOARDHANDICAPPEDHARDWAREHARDWOODHOLLOW METAL HORIZONTALHIGH PERFORMANCE COATINGHIGH PRESSURE DECORATIVE LAMINATEHOURHEIGHTHEATINGHEATERHEATING, VENTILATION AIR CONDITIONINGHOT WATERHOT WATER HEATER
FLRFLUORFMFRFRP
FRTFRTWD
FTFTGFURRFVCFWC
GAGALVGCGLGRGYP BDGWB
HHBHCHDBDHDCPDHDWRHDWDHMHORIZHPC
HPDL
HRHTHTGHTRHVAC
HWHWH
INSIDE DIAMETERINCHINCLUDE (INCLUSIVE)INSULATIONINTERIOR
JANITORJOIST
KNOCK DOWNKNOCK OUT
LENGTH (LONG)LAMINATE(D)LAVATORYPOUNDLINEAR FEET (FOOT)LIMITEDLIGHTLIGHTINGLOUVER
MARBLEMASONRYMATERIALMAXIMUMMECHANICALMEMBRANEMANUFACTURERMANHOLEMINIMUMMISCELLANEOUSMASONRY OPENINGMOUNTEDMETALMULLION
NOT APPLICABLENOT IN CONTRACTNUMBERNOMINALNOT TO SCALE
IDININCLINSULINT
JANJST
KDKO
LLAMLAVLBLFLIMLTLTGLVR
MARBMASMATMAXMECHMEMBMFRMHMINMISCMOMTDMTLMULL
N/ANICNONOMNTS
OVERALLON CENTERON CENTER ABOVE FINISH FLOOR
OUTSIDE DIAMETEROVERHEAD DOOROPPOSITE HANDOVERFLOW ROOF DRAINOUT TO OUTOPENINGOPPOSITEOPTIONAL
PAVER TILEPARTICLE BOARDPRECAST CONCRETE POUNDS PER CUBIC FOOTPREFACED CONCRETE MASONRYPERIMETERPEG BOARDPLATEPLASTICPLASTIC LAMINATEPLUMBINGPREMOULDEDPANELPAINTPLYWOODPOLISHEDPAIRPREFINISHEDPREFABRICATEDPROJECTIONPRE-STRESS CONCRETEPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPOINT/PAVER TILEPAINTEDPARTITIONPRESSURE TREATED WOODPOLYVINYLCHLORIDEPAVEMENT
OAOCOCAFF
ODOHDROPHOVRDO/OOP'GOPPOPT
PTPBDPCPCFPCM
PERIMPG BDPLPLASPLAMPLBGPMLDPNLPNTPLYWDPOLPRPREFINPREFABPROJPSCPSFPSIPTPTDPTNPTWDPVCPVMT
QUARRY TILEQUANTITY
RISERRETURN AIRRADIUSRETURN AIR GRILLEROOF DRAINRECEPTACLEREFRIGERATORREGISTERREINFORCEMENT (REINFORCING)REQUIREDRESILIENTRETURNREVISED (REVISION)RESINOUS FLOORINGROOMROUGH OPENINGREVERSE
SOLID CORESCHEDULE SMOKE DETECTORSADDLESECTIONSHEETSIMILARSLATESTAND PIPESPECIFICATIONSSPEAKERSPRINKLERSINGLE PLY ROOFINGSQUARESQUARE INCHSQUARE YARDSTAINLESS STEEL/ SLOP SINKSTANDARDSTEELSTORAGESTRUCTURE(AL)
QTQTY
RRARADRAGRDRECREFREGREINF
REQ'DRESRETREVRFRMRORVS
SCSCHEDSDSDLSECTSHTSIMSLTSPSPECSPKRSPKLRSPRSQSQ INSYSS
STDSTLSTORSTRUC
SUSPENDEDSHEET VINYLSEAMLESS VINYL - NON SLIPSEAMLESS VINYL SHEETSYSTEMS
THREADTONGUE AND GROOVETONGUE AND GROOVETRENCH DRAINTELEPHONETEMPORARYTEMPEREDTERRAZZOTEXTURETHICKTHRESHOLDTOP OF CONCRETE (TOP OF CURB)TOP OF STEELTOP OF DECKTOP OF MASONRYTOP OF JOISTTOP OF PARAPETTOP OF WALLTYPICAL
UNDERCUTUNDERGROUNDUNFINISHEDUNLIMITEDUNLESS NOTED OTHERWISEURINAL
VERTICALVESTIBULEVINYL COVEVINYL COMPOSITE TILEVERIFY IN FIELDVINYL STRAIGHTVINYL WALLCOVERING
SUSPSVSVNSSVSSYS
TT/G T>DTELTEMPTEMP'DTERTEXTHKTHLDTOC
TOSTODTOMTOJTOPTOWTYP
UCUGUNFINUNLIMUNOUR
VERTVESTVCVCTVIFVSVWC
WIDTHWITHWITHOUTWALL TO WALLWATER CLOSETWALL CARPETWOODWATER HEATERMOISTURE AND MOLD RESISTANT GYPSUM WALL BOARDWINDOWWIRE GLASSWEIGHTWELDED WIRE FABRIC
YARD
WW/W/OW/WWCWCARWDWHWGWB
WINWGWTWWF
YD
ABBREVIATION LEGEND: SYMBOLS
A8888
8
8
8 8
8
8
8
8
X
X
88A8888
INTERIOR AND EXTERIOR ELEVATION REFERENCE:
DRAWING NUMBER(S)
SHEET NUMBER
STRUCTURAL GRID:
NEW GRID
REFERENCE GRID
BUILDING, WALL, AND DETAIL SECTION REFERENCE:
DRAWING NUMBER
SHEET NUMBER
88A8888
ENLARGED PLAN OR DETAIL CALLOUT REFERENCE:
DRAWING NUMBER
SHEET NUMBER
888A
2-D-101
150 SF
ROOM NAME
FUNCTIONS
DOOR IDENTIFICATION:
NEW
888A
EXISTING
DOOR LETTER
DOOR NUMBER CORRESPONDS TO ROOM NUMBER
ROOM IDENTIFICATION:
ROOM NAME
ROOM NUMBER
ROOM AREA (WHEN INDICATED)
CEILING IDENTIFICATION:
WWW-88
88'-8"
CEILING TYPE
CEILING HEIGHT ABOVE FINISH FLOOR
WALL IDENTIFICATION:
WW88 A WALL TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS
KEYNOTE IDENTIFICATION:
KEYNOTE NUMBER; SEE CORRESPONDING NOTE ON KEYNOTE LEGEND ELSEWHERE ON SAME SHEET
?
FINISH FLOOR LEVEL
101.00
FINISH FLOOR LEVEL
101.00
LEVEL LINE, CONTROL POINT, OR DATUM:
NEW LEVEL
EXISTING LEVEL W
WINDOW / STOREFRONT GLAZING IDENTIFICATION:
WINDOW OR STOREFRONT GLAZING TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS.
1. ALL PRODUCT INSTALLATION SHALL BE PERFORMED ACCORDING TO MANUFACTURER'S WRITTEN SPECIFICATIONS AND INDUSTRY STANDARDS.
2. NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE OWNER, CONTRACTOR AND ARCHITECT.
3. ALL CONTRACTORS SHALL BE LICENSED AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.4. ALL CONTRACTORS SHALL INSPECT THE PROJECT AS RELATED TO THEIR SCOPES OF WORK AND
BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AS REQUIRED FOR THE PROPER EXECUTION OF THEIR WORK.
5. ANY CONFLICTS OR INTERFERENCES OF THE PROPOSED WORK WITH THE EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR FOR RESOLUTION WITH THE OWNER AND ARCHITECT.
6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING DISRUPTIONS TO THE UTILITIES AND SHALL INFORM THE OWNER OF SUCH ACTIVITIES.
7. "FURNISH" MEANS TO SUPPLY TO THE JOBSITE. "INSTALL" MEANS TO PLACE THE ITEM IN THE SPECIFIED LOCATION AND MAKE IT FUNCTIONAL. "PROVIDE" MEANS TO FURNISH & INSTALL.
8. THE JOBSITE SHALL BE KEPT FREE OF DEBRIS AND MADE BROOM-CLEAN EACH DAY.9. MOCK-UPS AND SAMPLES SHALL BE PROVIDED TO THE OWNER FOR ALL NEW FINISHES. MOCK-UPS
MAY BE PART OF THE FINAL WORK AND APPROVED BY THE OWNER AND ARCHITECT, PROVIDED OTHER REQUIREMENTS ARE MET.
10. ALL EXISTING CONDITIONS AND NEW WORK ARE "TYPICAL" UNLESS NOTED OTHERWISE.11. THE GENERAL CONTRACTOR AND SUB CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH ALL
EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID, NOTIFY THE OWNER IMMEDIATELY OF ANY DISCREPANCIES.
12. ALL MATERIALS FURNISHED ON THE JOB SITE SHALL BE NEW AND STORED IN SUCH A MANNER AS TO PROTECT THEM FROM THE ELEMENTS.
13. DO NOT SCALE DRAWINGS, DIMENSIONS AND/OR EXISTING CONDITIONS GOVERN, NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.
14. SUPPORT WIRES FOR CEILINGS, SOFFITS, ETC. SHALL NOT BE CONNECTED TO ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING, ETC.
15. DURING CONSTRUCTION THE CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE OWNER OR OWNER'S REPRESENTATIVE.
16. ENTRIES IN THE REVISION COLUMN OF ANY SCHEDULED ITEM INDICATE THAT THE ITEM HAS CHANGED IN THAT REVISION SEQUENCE. ITEMS REMOVED FROM THE PROJECT WILL NOT APPEAR IN SCHEDULES.
PROJECT GENERAL NOTES LOCATION AND SITE DATA
NORTHPROJECT LOCATION
DANIELJ.
BARNEY
0413550
TC
ETI
HCRADERE
T
SIG
ER
OI
HOFO
ETATS
DANIEL J. BARNEY , LICENSE#: 0413550
EXPIRATION DATE: 12/31/2021
arc
hit
ec
ts +
urb
an
ists
A
rchitectu
re •
Pla
nnin
g •
Inte
rio
rs •
Pre
serv
ation •
Urb
an D
esig
n
www.arkinetics.com
Cle
vela
nd O
ffic
e3723 P
earl R
oad
Cle
vela
nd,
OH
44109
DEALER CODE:
SHEET #:
DATE:
PROJECT #:
DRAWING TITLE:
arkinetics © 2021
DRAWN BY: CHECKED BY:
Arkinetics, Inc. and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. The Instruments of Service shall not be used for future additions or alterations to this Project or for other projects, without the prior written agreement of Arkinetics, Inc. Any unauthorized use of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics, Inc. and their Consultants
ISSUE:MARK:
P:
216.7
49.7
800
F:
216.7
49.1
300
OH011
C:\R
evit\M
arh
ofe
r H
yun
da-C
uyah
oga
Fa
lls_2
10
15.0
2_
rbe
nto
n6
XF
9T
.rvt
10
/7/2
021
10
:24
:31
PM
RO
N M
AR
HO
FE
R H
YU
ND
AI
Marh
ofe
r H
yu
nd
ai C
uya
ho
ga
Fa
lls1
26
0 M
ain
Str
ee
t, C
uya
ho
ga F
alls
, O
hio
COVER SHEET
G0.01
21015.02
BRP DB
RON MARHOFER HYUNDAIMarhofer Hyundai Cuyahoga Falls
1260 Main Street, Cuyahoga Falls, Ohio
DRAWING INDEX
SheetNumber Sheet Name
ELECTRICAL
E0.01 ELECTRICAL SYMBOL LEGEND & LUMINAIRESCHEDULE
E0.02 POWER DISTRIBUTION & LIGHTING CONTROLDIAGRAMS
E0.03 ELECTRICAL PANEL SCHEDULES
E1.01 DEMO - SERVICE LEVEL LIGHTING PLAN
E1.02 DEMO - SHOW ROOM LIGHTING PLAN
E1.03 DEMO - SERVICE LEVEL POWER PLAN
E1.04 DEMO - SHOW ROOM POWER PLAN
E2.01 NEW - SERVICE LEVEL LIGHTING PLAN
E2.02 NEW - SHOW ROOM LIGHTING PLAN
E2.03 NEW - SERVICE LEVEL POWER PLAN
E2.04 NEW - SHOW ROOM POWER PLAN
E3.01 SITE ELECTRICAL PLAN
E4.01 ELECTRICAL SPECIFICATIONS
E4.02 ELECTRICAL SPECIFICATIONS
MECHANICAL
M0.01 HVAC SPECIFICATIONS AND LEGEND
M0.02 HVAC SCHEDULES AND DETAILS
M1.01 DEMO - SERVICE LEVEL HVAC PLAN
M1.02 DEMO - SHOW ROOM HVAC PLAN
M2.01 NEW - SERVICE LEVEL HVAC PLAN
M2.02 NEW - SHOW ROOM HVAC PLAN
M3.01 HVAC ISOMETRIC DIAGRAMS
PLUMBING
P0.01 PLUMBING SPECIFICATIONS, SCHEDULES, ANDDETAILS
P1.01 PLUMBING PLANS
DRAWING INDEX
SheetNumber Sheet Name
GENERAL
G0.01 COVER SHEET
G0.02 LIFE SAFETY PLAN
ARCHITECTURAL
AS.01 ARCHITECTURAL SITE PLAN
A0.01 DEMO - SERVICE LEVEL PLAN
A0.02 DEMO - SHOWROOM PLAN
A0.03 DEMO - EXTERIOR ELEVATIONS
A1.01 NEW - SERVICE LEVEL PLAN
A1.02 NEW - SHOWROOM PLAN
A1.03 NEW SERVICE LEVEL RCP
A1.04 NEW SHOW ROOM RCP
A1.05 ROOF PLAN
A1.10 FURNITURE AND GRAPHICS PLANS
A1.11 FINISH PLAN
A1.21 WALL TYPES & DETAILS
A2.01 EXTERIOR ELEVATIONS
A3.11 WALL SECTIONS
A3.12 WALL SECTIONS
A3.21 WALL SECTION DETAILS
A4.21 ENLARGED ELEVATOR PLANS, SECTION ANDDETAILS
A5.01 INTERIOR ELEVATIONS
A5.11 MILLWORK SECTIONS & DETAILS
A6.01 DOOR AND WINDOW SCHEDULES
A6.02 FINISH SCHEDULE & VENDOR INFORMATION
STRUCTURAL
S0.01 GENERAL NOTES
S1.01 DEMO - SERVICE LEVEL PLAN
S1.02 DEMO - SHOW ROOM FLOOR PLAN
S1.03 DEMO - ROOF PLAN
S1.04 SERVICE LEVEL FOUNDATION PLAN
S1.05 SHOW ROOM FLOOR FRAMING PLAN
S1.06 SHOW ROOM SLAB PLAN
S1.07 ROOF FRAMING PLAN
S3.01 SECTIONS
S3.02 SECTIONS
S4.01 ENLARGED FRAMING PLAN
S5.01 TYPICAL DETAILS
DRAWING INDEXPROJECT RENDERING
REQUIRED SUBMITTALS
ARCHITECTURAL• ROOFING / ROOFING SYSTEM• METAL STUD FRAMING• ACOUSTICAL CEILING TILE• FLOOR AND WALL FINISHES• GROUT• FRP• MILLWORK• PLUMBING FIXTURES• DOORS• DOOR FRAMES• DOOR HARDWARE• OVERHEAD DOORS• STOREFRONT / CURTAINWALL• GLASS AND GLAZING• FIRE EXTINGUISHERS AND CABINETS
• ALUMINUM COMPOSITE MATERIAL (ACM)• JOINT SEALANT• GUARDRAILS / RAILINGS• AIR/WATER BARRIERS• WALL INSULATION• KNOXBOX• COPING
AS REQUIRED BY THE ARCHITECT. ENGINEERS WILL REQUIRE
ADDITIONAL SUBMITTALS AS INDICATED IN THEIR SPECIFICATIONS
PERMIT 10/7/2021