principles for hplc methods development

Post on 10-Feb-2016

110 Views

Category:

Documents

2 Downloads

Preview:

Click to see full reader

DESCRIPTION

Principles for HPLC Methods Development. Bioanalytical Chemistry Lecture Topic 4. Five Stages. Define problem Experiment with key variables Evaluate Optimize Troubleshoot. Define. What is the purpose? Analytical Preparative - PowerPoint PPT Presentation

TRANSCRIPT

Principles for HPLC Methods Development

Bioanalytical ChemistryLecture Topic 4

Five Stages Define problem Experiment with key variables Evaluate Optimize Troubleshoot

Define What is the purpose?

– Analytical– Preparative

What are the molecular characteristics of the analyte and sample?– CHASM

CHASM Charge

– Positive/negative Hydrophobicity Affinity

– “lock and key” sites Solubility & stability

– pH, ionic strength, organic solvents Molecular weight

Analytical vs. Preparative Analytical Requirements

– Linearity– Precision– Accuracy– Sensitivity– Assay reproducibility– Robustness

Analytical vs. Preparative Preparative Requirements Recovery Product purity Capacity Costs

– Scale up– Process throughput– Speed

Methods Development Select the mode pH map Optimize gradient/elution

– gradient slope– eluent concentration

Loading study– overload: peak width and shape

Common Modes Reverse phase (RPC)

– Stationary phase hydrophobic and mobile phase hydrophilic

• column: silica, polystyrene covalently modified with alkyl chain 3-18 C’s

– EX: octadecylsilane (ODS) - C18

• mobile phase: buffered water + organic solvent (propanol CH3CN, CH3OH)

• gradient elution

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3 H2O

H2O

H2O

H2O

CH3CN

CH3CN

Reverse Phase

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

H2O

H2O

H2O

CH3OH

Reverse PhaseC6H6

C6H6

C6H6

CH3OH

Non-polar polar

Polarity?

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

CH2CH2CH2CH2CH2CH2CH2CH3

H2O

H2O

H2O

CH3OH

Reverse Phase – 50/50?

C6H6

C6H6

C6H6

CH3OH

Mobile phaseMore/less polar?

Non-polar polar

Common Modes Ion-Exchange (IEC)

– Ion exchange interactions between cationic or anionic analyte and stationary phase bearing opposite charge

• stationary phase: polystyrene, silica modified with functional groups such as quaternary amines

• mobile phase: buffer containing increasing concentration of salt (NaCl, MgCl2, K3PO4, NH4SO4)

• gradient elution

Evaluation Resolution

– degree of separation between analyte and other species present in mixture

– bandspreading– selectivity

Recovery– mass recovery– activity recovery

Capacity

Developing Your Application

Proteins

Antibodies

Peptides

Nucleic acids

Proteins All modes can potentially be used

Ion exchange common first step– mobile phase less denaturing

Antibodies – Affinity

Peptides amino acid chain < 30 residues (5000 MW)

reverse phase most commonly used– historical

ion exchange can be equally effective

Nucleic Acids gel electrophoresis commonly used

anion exchange predominant chromatographic method

Ion Exchange Sample must be ionized in order to be retained

on column significantly

Anion exchange (anionic acidic proteins)X- + R+Cl- = X-R+ + Cl-

Cation exchange (protonated basic proteins)X+ + R-K+ = X+R- + K+

Column Type 4 types: strong/weak cation/anion

Strong - ionization of ionic group does not change over usual pH range– better starting point

Weak - lose charge and sample retention for certain pH ranges

Cation Exchangers Strong cation exchanger (SCX)

– sulfonic acid, SO3-

Weak cation exchanger (WCX)– carboxylic acid, COO-

Anion Exchangers Strong anion exchanger (SAX)

– quaternary ammonium, e.g., N(CH3)4+

Weak anion exchanger (WAX)– diethylaminoethyl (DEAE)

pH Effects Anion exchange

– RCOOH = RCOO- + H+

– INcrease in pH leads to greater sample ionization and retention

Cation exchange– RNH3

+ = RNH2 + H+

– DEcrease in pH leads to greater sample ionization and retention

Salt/Buffer Effect Mobile phase cations/anions can displace

analyte on column

All salts are NOT equal– Anions:

• F- < OH- < Cl- < NO3- < citrate3- (strong)

– Cations:• Li+ < H+ < NH4

+ < K+ < Mg2+ < Ca2+ (strong)– Polyvalent ions held more strongly by ion

exchange column than monovalent ions

Salt/Buffer Effect Need to select appropriate pH:

– Anion exchange, pH > 6 used– start: pH 8.5

• protein stable?• extreme end of pH range• binding should be tightest

– Cation exchange, pH < 6 used (pH 4.0)

Salt/Buffer Effect Select Salt

– 0.5 - 1.0 M

Gradient– 0 - 100 % gradient - to determine relative

retention of sample– long, shallow to start:

• 0 - 1 M NaCl, 50 - 100 CV’s

Organic Solvent Effect Addition of organic solvents decreases

retention– Be careful! Can denature biomolecules

Can be used to create changes in selectivity

EXS: methanol or acetonitrile– water miscible

Cytochrome c Function:

Redox protein involved in cell apoptosis and respiration

Structure: heme protein– FW 12,384

(horse)– Basic protein 3CYT: Takano, T., Dickerson, R. E.: Redox conformation

changes in refined tuna cytochrome c. Proc. Natl. Acad. Sci. USA 77 pp. 6371 (1980)

What mode should we use?

Cyt cCOO-

COO-

COO-

COO-

K+

K+

K+

K+

K+

K+

K+

K+

Cyt cCOO-

COO-

COO-

COO-

Cyt c

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

K+

K+

K+

K+

COO-

COO-

COO-

COO-

Cyt c

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

K+

K+

K+K+

K+

COO-

COO-

COO-

COO-

Cyt c

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

Na+

Na+

Na+

Na+

Na+

Na+

Na+Na+

Effect of pH

What Does Cyt c look like at low pH?

COO-

COO-

COO-

COO-

Cyt c

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

NH3+

Na+

Na+

Na+

Na+

Na+

Na+

Na+Na+

Effect of pH

What Does Cyt c look like at high pH?

COO-

COO-

COO-

COO-

Cyt c

NH2

NH2

NH2

NH2

NH2

NH2

NH2

Na+

Na+

Na+

Na+

Na+

Na+

Na+Na+

Effect of pH

So low pH more effective for cation exchange than high pH

Useful References “The Busy Researcher’s Guide to

Biomolecular Chromatography,” Perspective Biosystems, publication date unknown.

Snyder, L.R.; Kirkland, J.J.; Glajch, J.L. “Practical HPLC Method Development,” 2nd ed. John Wiley & Son: New York, 1997.

top related