pre-finished - ca.miele.ca · pre-finished 36” mastercool ii k 2901 sf* / k 2911 sf* f 2901 sf* /...
Post on 13-Sep-2019
12 Views
Preview:
TRANSCRIPT
Pre-finished36” MasterCool II
K 2901 SF* / K 2911 SF*
F 2901 SF* / F 2911 SF*
KF 2901 SF / KF 2911 SF
KF 2981 SF
8miele.caSpecification Sheets TRS 04252019
Shown: KF 2981 SFPlease note: This information is subject to change*The following models are not available in Canada : K 2901 SF, K 2911 SF, F 2901 SF & F 2911 SF
DRAFT
Pre-finished 36” MasterCool II
Please note the following:• This specification sheet is for a single built-in unit.• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet. *If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
SPECIFICATIONS
Overall Unit Dimensions 353/4” (908 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]
Overall Fascia Dimensions 361/2” (927 mm) W x 84”- 8511/16” (2134 - 2175 mm) H x 11/2” (32 mm) D
Niche
Minimum Cabinet Niche Opening 36” (915 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 24” (610 mm) D
Interior Volume K 29x1 SF F 29x1 SF KF 29x1 SF
Refrigeration Volume ** 0 **
Freezer Volume 0 ** *
Electrical K 29x1 SF F 29x1 SF KF 29x1 SF
Electrical Requirements110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 29x1 SF F 29x1 SF KF 29x1 SF
Water Supply Requirements -
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres-sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Water Connection Line - Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
Shipping K 29x1 SF F 29x1 SF KF 29x1 SF
Shipping Weight 483 lbs (219 kg) 495 lbs (225 kg) 588 lbs (267 kg)
Shipping Dimensions 40” (1016 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D
Support
Call Miele (800) 565-6435
Miele Website 8www.miele.ca
20/20 Link 82020technologies.com
K 2901 SF (Right Hinged)
K 2911 SF (Left Hinged)
F 2901 SF (Right Hinged)
F 2911 SF (Left Hinged)
KF 2901 SF (Right Hinged)
KF 2911 SF (Left Hinged)
Page 2 of 6
KF 2981 SF (French Door)
CUTOUT DIMENSIONS
Pre-finished 36” MasterCool II
CUTOUT DETAILS
• The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.
• The 1/4” (6.4 mm) plumbed water connection should not be positioned higher than 2” (50.8 mm) above the floor.
Notes:In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 6
SF frame
9/32”(7)
3/4”(19) Stainless steel door
Niche/Cabinetry
Please note unit’s outer SF frame.Top view:
POWER SUPPLY AND WATER CONNECTION(Water Connection For F 29x1 SF & KF 29x1 SF Only)
Pre-finished 36” MasterCool II
Water connection is located in front of unit.1/4” compression fitting is needed.
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp - NEMA 5-15 molded plugWater line - 1/4” flexible water line - not included
Rear View Front View
Electrical Connection
Side View
Page 4 of 6
HINGING DETAILS 115° OPENING
Pre-finished 36” MasterCool II
Available for the following models:• K 29x1 SF• F 29x1 SF• KF 29x1 SF
Page 5 of 6
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
3”(76.2mm)
1-3/4”(44.5mm)
1-3/8”(35mm
)1-1/6” (29.6m
m)
1/4”(6.4mm
)17/24” (18m
m)
2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)
0-3/4” (19 mm
)1” (25 m
m)
1-1/4” (32 mm
)1-1/2” (38 m
m)
1-3/4” (44 mm
)
1-1/2” (38 mm)
1-1/4” (32 mm)
1” (25 mm)
0-3/4” (19 mm)
0-1/8” (3 mm)
DOOR SWING AT 115° OPENING 11 3/4”(298 mm)
Max
HINGING DETAILS 90° OPENING
Specification Sheets TRS 04252019
Pre-finished 36” MasterCool II
Available for the following models:• K 29x1 SF• KF 29x1 SF
Page 6 of 6
7/16”(11 mm)
1-3/16”(30mm)
1-7/16”(36.5mm)
1-11/16”(43mm)
1-15/16”(49.2mm)
Handle or object that is NOT flush with Cabinet Front.
0-3/4” (19 mm
)1” (25 m
m)
1-1/4” (32 mm
)1-1/2” (38 m
m)
1-3/4” (44 mm
)2” (51 m
m)
0-3/4” (19 mm)
1” (25 mm)
1-1/4” (32 mm)
1-1/2” (38 mm)
0-1/8” (3 mm)
When installing hinge side next to an appliance or object that is within range of the door panel, limit the door opening angle to 90°. This is done by installing the banking pin as illustrated. Insert the banking pin through the holes and drive in with a hammer.
DOOR SWING AT 90° OPENING 7/16” (11 mm)
38 11
/16” (
982
mm
)
top related