kiln pre heater fan power calculation

Post on 21-Dec-2015

70 Views

Category:

Documents

4 Downloads

Preview:

Click to see full reader

DESCRIPTION

kiln Pre heater Fan Power calculation

TRANSCRIPT

Fan Power Calculator

Height above MSL : 300 Elevation Factor :

Description Preheater

Fan

Plant TPD : 7500

Am3/Hr 1000000

Nm3/Hr 434333

1.39

Mbar 54

300

Fan Efficiency % 80

40

(of the mediam handled) 1.42

0.617

Nm3/Kg Clinker

Temp. oC

Dust load gm/m3

Air Density Kg/m3

Air Density Kg/m3

0.657

Kw - without dust 1875.00

Kw - with dust 1996.60

Margin on shaft power 5%

Min. Motor Kw 2096.43

Motor loss + Cable Losses 0.95

Power Consumption 6.73

( At Meters ) kwh/t

Air Density Kg/m3- with dust

Fan Power Calculator

Elevation Factor : 1.036