established in athens, greece in 2002

Post on 05-Jan-2016

22 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

Established in Athens, Greece in 2002. COMPANY SCOPE The company develops, integrates, and delivers complete solutions in the field of Laser Remote Sensing. We manufacture high-technology LIDAR SYSTEMS and we provide Services, maintenance and upgrades related to these instruments - PowerPoint PPT Presentation

TRANSCRIPT

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

Established in Athens, Greece in 2002

COMPANY SCOPEThe company develops, integrates, and delivers complete solutions in the field of Laser Remote Sensing.

We manufacture high-technology LIDAR SYSTEMS and we provide

• Services, maintenance and upgrades related to these instruments • a full spectrum of lidar hardware

• software for data retrieval, instrument control and lidar data analysis

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LB - Series Lidar systems (Elastic Backscatter)

LR - Series Lidar systems (Raman)

Ozone DIAL LIDAR systems

Design & Development

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LR-ESS-D200Eye–safe: YesDepolarization: Yes, Raman: YesVertical or scanning deployment, Mobile: YesLaser power monitoring, Pre-trigger: upon user request

LB–LR D200Multi-wavelength systemEffective range of measurements: from 150 m up to 15-18 kmEye–safe: NoDepolarization: Yes, Raman: Yes, up to 6 detected channelsMobile: Yes, Power monitoring, Pre-trigger: upon user request

LR –IVU – D400Multi-wavelength system Effective range of measurements: from 450 m up to the strato-sphere, Eye–safe: NoDepolarization: Yes (2), Raman: Yes (2), Water vapor: YesMobile: Yes / Laboratory version also possibleLaser power monitoring, Pre-trigger: upon user request

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

Multi-wavelength Ozone/Aerosol DIAL system

(266-289-299-316-532S/P-1064 nm)Effective range of measurements: from 800 m up to 15-20 km (up to 60 km upon request)Daytime - nigh-time operationEye–safe: NoUp to 7 detection channelsTransportableLaser power monitoring, Pre-trigger: upon user request

Airborne version: available upon request

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

CUSTOMIZATION

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LICEL Acquisition System

Open source software for:• Data acquisition• System checking and controlling• Lidar data analysis•Ascii files, Binary files or NetCDF

Fully simulated: ray-traced and mechanically, +/- 45o depol. Calibration procedure, Telecover Tests etc.

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

INDIA New Multiwavelength Lidar System

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

INDIA New Multiwavelength Lidar System

top related