doppler log jln-205 - jrc · 2017-01-30 · doppler log jln-205 med certificate number :...
Post on 02-Jan-2020
5 Views
Preview:
TRANSCRIPT
DOPPLER LOGJLN-205
MED Certificate Number : QQ-MED-39/04-01
Stable & high accurate measurement Easy reading of speed indication
E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 2
Operating Method Dual beam, pulse Doppler sensing
Frequency 2MHz
Speed Range -10.0 to +40.0 knot
Distance-run Range 0 to 99999.99 nm *Note: NWW-7 optional indicator allows the range from 0 to 9999.99 nm
Depth Range 3m or more (below hull bottom)
Accuracy +/- 1% or +/- 0.1 knot whichever is greater +/- 1% or +/- 0.1 nm whichever is greater
Indiction Digital indicator Analog indicator (where using option unit of NWW-24 / 25 / 26)
IEC61162-1 Input RMC, RMA or VTG (for SOG indication from GPS receiver)
IEC61162-1 Output 8 port / $VDVBW, $VDVLW sentence
Other Outputs for Analoge indicator: 2 circuits / Pulse for distance-run : 4 circuits /
Contact closure: 1 circuit / for Sub display: 2 circuits / for Distance-run indicator: 1 circuit /
for Remote display: 1 circuit / for Remote diagnostic data port: 1 circuit /
for power fail: 1 circuit
Power Supply 100 / 110 / 115 / 220 / 230 Vac +/- 10%, 50/60Hz, 1-phase
Power Consumption 100VA or less
Operating Temperature -15 to +55 deg. C
S
O
FEATURES
SPECIFICATIONS
M
S
N
1
1
1
1
The JLN-205 Doppler Log is designed as a device of ship speed measurement and information. The JLN-205 utilizing high frequency of ultrasonic wave brings high stability and accuracy of speed measurement. In addition, a miniaturized transducer will enable to install on the bow where is in less influence against tiny bubbles.
●Ensuring accurate measuring and stable indicating of ship speed since measurement is insensible to bubbles generated in navigation. ●The installation on bow of what is less bubbles influence will be accomplished with a miniaturized transducer. ●The large characters in main display helps easy glance. ●To enable connecting GPS receiver will bring comprehensive speed information calculated by GPS information. ●Various option units can help to configure an optimal Doppler Log system.
C
IMO Resolution A.824(19),Revised IMO Resolution MSC.96(72),IMO Resolution A.694(17). IEC60945:2002,IEC61162-1:2000
This equipment is complied with the following standards.
E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 3
STANDARD COMPONENTS
OPTION COMPONENTS
Normal viewer with large charactor with instruction comment graphic viewer
Main Display can provide suitable viewer from various screen types.
Sub Display(Option) NWW-65S
Analog Indicator(Option) NWW-24
Main Display NWW-65 Remote Display(Option) NWW-16
Remote Display(Option) NWW-5
Data Distributor NQA-4288
Signal Processor NJC-25
Transducer NKF-547
or
Ship's mainMax 500m
Transducer Gate-valve type (Option) NKF-531E
No. NAME TYPE Q'TY REMARKS
1 Main Display NWW-65 1 Desktop,(Flush mounting kit : option), with a cable of 5m length
2 Data Distributor NQA-4288 1
3 Signal Processor NJC-25 1 IPx5
4 Transducer NKF-547 1 With a cable of 30m length
5 Spare Parts 7ZXBS0020 1
6 Instruction Manual 7ZPBS2803
No. NAME TYPE Q'TY REMARKS
1 Sub Display NWW-65S Max. 2
2 Analog Indicator NWW-24 Flush mouting
3 NWW-25 Max. 2 Bulkhead mounting / Waterproof
4 NWW-26 Panel mounting
5 Remote Indicator NWW-5
6 Remote Indicator NWW-16
7 Distance-run Indicator NWW-7 Max. 1 Ship's speed (fore / aft) / Distance-run / Indication range: 9999.99 nm
8 Dimmer Unit NCM-227D - For main / sub display
9 NCM-329 - For analog indicator
10 NCM-227 - For remote indicator
11 Connection Box NQD-2025 1 for extension between NWW-65 and NQA-4288
12 Transducer (Gate-valve type) NKF-531E 1 With a cable of 25m length
13 Flush mounting kit MPTG30432 - for Main / Sub Display
Distance-run Indicator(Option) NWW-7
CONNECTION DIAGRAM
Max. 1Ship's speed (fore / aft)
Ship's speed (fore / aft) / Distance-run / Indication range: 9999.99 nm
E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 4
StaEas
DIMENSIONS
Main Display NWW-65 Main Display Flush-mounting type (NWW-65)
Data Distributor NQA-4288
Transducer NKF-547
Signal Processor NJC-25
CLR OFF
PWR OFF
MODE
JLN-205
CONT DIM
(46.5) 197 104 46.5
21
138 117
DOPPLER LOG
CABLE INLET
28 96 124
55
PUSH
CLR OFF
PWR OFF
MODE
PUSH
DOPPLER LOG JLN-205
CONT DIM
117
197 WALL
CABLE INLET
11.5 27 70
130
470
300
4-R4.5
420
490
240
CABLE INLET
警告 WARNINGこのカバーをはずすな 感電の恐れあり
HIGH VOLTAGEDO NOT REMOVETHE COVER.
MADE IN JAPAN
NB 0191-**
380
360
220 123
310
280
φ13~φ18
CABLE INLET
4-R4.5
XXXXXXX DATE
XXXXXXX
SIGNAL PROCESSOR
COMPASS SAFE DISTANCE
SERIAL NO.
MODEL
3.0m
NJC-25
警告 WARNINGこのカバーをはずすな 感電の恐れあり
HIGH VOLTAGEDO NOT REMOVETHE COVER.
MADE IN JAPAN
SEAWATER AREA
SEPARATE FROM POWER CABLE
SHEET PACKING
4-M16×40BOLT SPRING LOCK WASHER
CABLE φ13.2
(10K-32) (SHIP YARD)
(MOUNTING HOLE φ137)
FLANGE JIS B 2220
CFT-022B-30
(SHIP YARD)
(SHIP YARD)
(SHIP YARD)
(SHIP YARD)
PIPING
130
φ50
φ100
(2)
(16)
26
φ135 ±1
RED
WHITE
BOW MARK
BOW MARK(TRANSDUCER)
BOW
10゚
WELD
(SHIP YARD) WELD DO NOT PAINT THIS
RADIATION SURFACE
INSTALL UNDER AN ANGLE OF ±5° DEGREES TO THE BOW-STERN DIRECTION
Unit:mm Weight:0.8kg Unit:mm Weight:0.8kg
Unit:mm Weight:6kg Unit:mm Weight:10kg
Unit:mm Weight:17kg
For further information, contact:
Since 1915
Main Office:
Overseas Branches : Seattle, Amsterdam, Athens, Manila Liaison Offices : Taipei, Jakarta, Singapore, Hanoi,
Shanghai, Hamburg, New York
28EM ISO9001,ISO14001 Certified
●Specifications may be subject to change without notice.
URL eng
Printed in Japan2005.4 CAT.No.Y14-197(No.849-7-2)D2011.12
Fujisawa bldg. 30-16, Ogikubo 4-chomeSuginami-ku, Tokyo 167-8540, JapanTelephone: +81-3-6832-1816Facsimile: +81-3-6832-1845
E_JLN-205_1128.qxd 11.11.28 7:07 PM ページ 1
top related