controls · 2018-06-08 · intesis - interfacce bms 209 controls homebidin atomation. 200 controls...
Post on 13-Apr-2020
2 Views
Preview:
TRANSCRIPT
198
CONTROLSWHAT IS TECHNOLOGY WITHOUT CONTROL? Mitsubishi Heavy Industries presents a complete range of controls for residential, commercial and KXZ systems, ensuring ease of use and maximum performance for all needs.
MHI devices allow for extreme ease and installation flexibility for complete local and remote control on any size system.
199
Standard remote controls 200
Individual optional controls 201
Optional kits for remote control 203
Control devices 203
Wi-Fi control 204
Superlink II system 205
Centralised controls 206
Control devices 207
Digital interface cards 208
INTESIS - INTERFACCE BMS 209
Controls
HOME&BUILDING AUTOMATION
200
Controls
Standard remote controls
The weekly Timer can be set using these buttons
ON/OFF: Turning on and off with illuminated button
Allergen Clear
New Timer functions: up to 28 weekly settings!
FAN SPEED: Ventilation
TEMP: Temperature
L/R: Horizontal swing in 8 directions
U/D: Vertical swing
WEEKLY TIMER PROGRAMMING•Upto4dailyprogramswithTIMERON/TIMEROFFoperation;
up to 28 weekly programs.•Modes:auto,cooling,heating,dehumidifyingandventilation.•CompatibilitywithRC-EX1Atouchscreencontrol.•Availablefunctions:Econo,NightSetback,Silent.
NIGHT SETBACK FUNCTION
Duringthecoldmonths,keeptheroomtemperatureatacomfortablelevelwhenyou'renothome,atnightandwhentheroom is empty. The air conditioner keeps a constant temperature of about 10°C.
“ULo” FAN SPEED
ThenewZSX,ZS,ZRandZMXseries(seetechnicalmanuals)areprovidedwiththeULofanspeedformaximumsilence.
MONOSPLIT - MULTISPLIT
•Homeleavefunction•Silentfunction•Automatictemperature
setting•Automaticventilationsetting
SILENT FUNCTION (active with single OUs ZSX-ZS-ZR-ZMX and with multi OUs SCM 71 and 80 ZM-S1)
The compressor speed is set within a lower range than normal operation: the unit is operated at 60% of its nominal capacity.Themaximumfanspeedontheoutdoorunitissetbelowthestandard value.ThemaximumsoundpressureofallnewSRCoutdoorunitsinSilentmodebecomes3dB(A)lowerthannormaloperationandstilllessthan45dB(A).
COMPATIBILITY WITH THE TOUCH SCREEN COMMAND FUNCTIONS
SRK ZSX-S(T) - SRK ZS-S(T)- SRK ZR-S -SRF ZMX-S
201
USB
Controls
Individual optional controls
MULTI-LANGUAGE TOUCH SCREEN RC-EX3
•TouchscreenwiredremotecontrolwithLCDdisplay.•Largesize:3.8"withbacklighting.Simple3-buttoninterface.All
settings can be made via the touch screen panel•Possibilityofselectingupto9languages.
ENERGY SAVING FUNCTIONS•Offtimer•Peak-cuttimer•Automatictempsetback•Weeklytimer•SetOn/Offtimerbyhour•SetOn/Offtimerbyclock
FUNCTIONS THAT GUARANTEE COMFORT
• Individualcontrolofairoutletlouvers•Highpoweroperation•ExternalOn/Offventilation•Heatingfunction•Automaticfanspeedfunction•0.5°Ctemperatureincreasesetting
SERVICES
•Errorcodedisplay•Operatingdatadisplay•Nextdisplaydata•Contactcompanydisplay•USBport(mini-B)
ADVANTAGES
•LCDdisplaycontrastsetting•Backlighting•Filtericon•Soundcontrol•Outdoorunitsilentmode•Summertimersetting• "Homeleave"mode• Indoorandoutdoortemperaturedisplay•Heatingstand-bydisplay•Defrostoperationdisplay•Modes:auto,cooling,heating•DisplayºC/ºF•Administratorsettings•Roomnamesetting
Outdoor unit Indoor units
RC-EX3eco-touch screen
RC-EX3commandcanbecontrolled via computer using
special software.
RC-EX3 control via software
202
Individual optional controls
WIRED REMOTE CONTROL WITH LCD DISPLAY RC-E5
WiredremotecontrolwithLCDdisplay:thisdisplayislargeandhigh-contrastforexcellentdisplayofinformation.Thewiredremote control is capable of controlling up to 16 indoor units.
Main functions:•Weeklytimerasstandard•Built-intemperaturesensor•Settabletemperaturefields•Datasavingfunction•4fanspeeds•Controlforadjustingthestaticpressure
SIMPLIFIED WIRED REMOTE CONTROL RCH-E3
Particularlysuitableforuseinhotelsandsmalloffices,itenablesthe selection of 3 different ventilation modes.Thesimplifiedwiredremotecontroliscapableofcontrollingup to 16 indoor units.Simpletouse,ithasthefollowingessentialbuttons:
•On/Off•Mode•Temp.setting•Fanspeed
Controls
203
Optional kits for remote control
Control devices
Type Model nr. Connectable IU
Individual controls
Wired remote control RC-EX3; RC-E5; RCH-E3 1
InfraredRCN-KIT4-E; RCN-T-5AW-E2; RCN-TC-24W-E2; RCN-TW-E2; RCN-TS-E2;RCN-K-E2; RCN-K71-E2; RCN-E-E2; RCN-FW-E2
1
Centralised control panel
KeypadSC-SL1N-E 16SC-SL2NA-E 64
Windows PC interface Touch screenSC-SL4-AE 128SC-SL4-BE 128
Windows PC interfaceBMS interface
WEBnet BACnet SC-WBGW256 256 (128x2)
BMS interface Lonworks SC-LGWNA-A 96 (48x2)
ControldeviceswithSUPERLINKII
Controls
RCN-TW-E2
FDT,FDTC
RCN-T-5AW-E2, RCN-TC-24W-E2
RCN-TS-E2
FDTW
RCN-KIT4-E2
FDUM,FDU,FDTQ,FDQS,FDUT,FDUH,FDFL,FDFU,FDF,FDU-F,SAF-DX
FDTS
RCN-K-E2
FDK
RCN-K71-E2
FDK71KXZE1
RCN-E-E2
FDE
RCN-FW-E2
FDFW
204
Termal presents the new MH-WIFI module which allows access to remote air conditioner control through a downloadable smartphone app*.ThankstotheMH-WIFIapp,youcanmanagethemainoperatingparametersfromyourhousewithasimplehomeWi-Ficonnection,orawayfromhome,withasimpleInternetconnection.WiththeTermalMH-WIFI,youcanswitchtheunitonandoff,adjusttheroomtemperatureandtheairflowoftheairconditionerandcoolingorheatingoperations,withasimpletouchfromyourmobilephone.An intelligent App that controls comfort and energy savings with a beneficial effect on your bill.
HOME AIR CONDITIONING CONTROL, EVEN FROM OUTSIDE YOUR HOME.
*TheMH-WIFIAppisavailableforiOSdevices.YoucandownloaditforfreefromAppleStoreattheQRCodelinkshown here.
Accesssecuritywithaccountprotectedbycredentials(UserID&PWD).
Uniqueidentificationofeachsingleunitthatyouwanttocheck.
On and off control.
Operating mode selection.
Adjustmentofthesettemperature.
Fan speed.
Weekly programming cycle setting (up to 39).
Enabling/disablingofthelocalremotecontrol.
MAIN MH-WIFI FUNCTIONS
SOME EXAMPLES OF SCREENS FROM iOS DEVICES.
Wi-Fi control
MITSUBISHI WI-FI
The only App that lets you control multiple rooms
TheMHIappletsyouindividuallyandentirelycontroldifferentindoorunits,adjustingairconditioninginmultiplerooms.
Controls
205
RC-EX3
SC-SL2NA-E
SC-SL4-AE/BE
SC-SL2NA-E
RC-E5 RC-E5 RC-E5
RC-EX3 RC-EX3
RC-E5 RC-E5 RC-E5
RC-E5
RC-E5
RC-E5RC-E5
IU Multi-KXZ-KXZXKXZ MICRO system
KXZ-KXZX system
PAC unit
An advanced fast data transmission system
Superlink II is able to connect up to 128 indoor units and 32 outdoor units on a network. Itisacentralisedcontrolsystemthatmeetsthedifferentneedsoflarge,mediumandsmallbuildings.TheimplementationoftheSuperlink II system greatly reduces installation costs by reducing the size of the wiring area using a non-polarised 2-wire cable. In ordertoharmoniseairconditioninganditsmanagement,MitsubishiHeavyIndustriesalsooffersawiderangeofcommandsandinstruments for a reliable control system. Easy access can thus be made for computerised management of the building to be air-conditioned,guaranteeingthehigheststandardonthemarketinafullyaffordablesystem.
light ventilation
IU Multi-KXZ-KXZX
IU Multi-KXZ-KXZX
KXZ-KXZX system
PC
other PC
Controls
SUPERLINKII
206
Centralised controls
CENTRALISED CONTROL PANEL SC-SL4-AE/BE
MHIintroducesitsnewSC-SL4-AE/BECentralisedControlwith9”interactive(FullColorTouch)LCDdisplay.Userscanperformmonitoring,programmingandmaintenancefromthepanel.It can control up to 128 indoor units.
UserscanconnectwithaPCortabletthroughanInternetExplorer(IPad,Windows)WEBinterface.
ALL NEW VERSION FUNCTIONS
The indoorunitscanbeprogrammed,monitoredandexamined individually, ingroups,and ingroupblockswith the followingfunctions:
Control Monitoring Programming Administration/ServiceOn/Off Operating status Yearly programming Block definitions
Cool/heat/fan/dry/Auto modes Mode Daily programming Group definitionsT° setting Temperature setting. Special daily programming Unit definition
Operations allowed/prohibited Ambient temperature Seasonal programming Date and Time settingFan speed Operations allowed/prohibited Alarm history
Air direction Fan speed Consumption calculation periodFilter signal reset Air direction Cumulative operating time
Request control (3 steps) Filter signal Energy consumptionEmergency stop Maintenance
Request control
ELECTRICAL CONSUMPTION CALCULATION FUNCTION (SC-SL4-BE ONLY)
Superlink IISC-SL4-BEisabletomonitorelectricalconsumptioninkW/hforeachindoorunitinasinglegroupontheSuperlinksystem,usingaUSBmemory.
SC-SL4-BEData export method USB / LANCalculation software StandardProportional distribution of air conditioner consumption (MAX pulse input) 8
Connectable units (MAX) 128
Model SC-SL4-AE/SC-SL4-BEAmbient temperature °C 0°C~40°CPower supply 1 Phase 100-240V 50/60HzConsumption W 18Dimensions (H x L x D) mm 172x250x23(+70)Net weight kg 2.00Number of connectable IU no. up to 128 unitsLCD touch panel LCD colour, 9” SL (Superlink) signal input 1 System (Superlink II)
Controls
207
Centralised controls
SC-SL2NA-E CENTRALISED CONTROL PANEL
The SC-SL1N-E panel is connected to the Superlink II system via a non-polarised2-wirecable. Itenables theuser to startup/stopandmonitorup to16 indoorunitssimultaneously.ThenumberofunitsinoperationcanbeseenonthespecialLEDs,ascanthosethatrequireassistance.InthecontextofaSuperlinkIIsystem,upto12SC-SL1N-Epanelscancoexist,foratotalof128indoorunitscontrolled.
Thisplatformenablesuserstoconnectandcentrallycontroltheindoorunits,convertingtheLonWorkscommunicationdataintoSuperlinkIIcommunicationdata.Upto96unitscanbecontrolled,thehighestnumberpossiblefortheLONsystemsonthemarket.
TheSC-SL2NA-EpanelisconnectedtotheSuperlinkIIsystemviaanon-polarised2-wirecable.Itenablestheusertostartup/stopandmonitorupto16groupssimultaneously,foratotalof64units.Italsomonitorsandcontrolsthefollowingfunctionsforeachunit,groupofunitsorforthewholenetwork:temperaturesetting,positionofthelouvers,operatingerrors.ThenumberofunitsinoperationcanbeseenontheLCD,ascanthosethat requireassistance.The timer facilitates thepoweronandpoweroffcycles.ThepanelcanbeconnectedatanypointintheSuperlinkIInetwork,tobothindoorandoutdoorunits,reducingthelengthofthewiringusedfortheconnections.
This platform makes a simple monitoring system possible for small and medium-sized installations: it includes metering functions and enables users to control up to 256 indoorunits(96groups-128indoorunitson2SuperlinkIInetworks).Safeandeasy:allyouneedisInternetExplorer,withoutusinganyadditionalsoftware.Using a filter on the IP address, the system lets users select and limit access to theplatform through 3 different levels of account authentication. Integrated metering function.
SC-SL1N-E CENTRALISED CONTROL PANEL
Devices for controlling the Superlink II Network
LONWORKS GATEWAY SC-LGWNB
WEB GATEWAY + BACNET GATEWAY WGWNB256
Controls
NEW
NEW
208
SC-ADNA-E INTERFACE CARD
Thisinterfacecardmakesitpossibletocreatea2-wireX,Ynetworkonunits(SRK,SRR,SRF),enablingmanagementusingtheRC-E5wiredremotecontrol.Furthermore,usingtheSC-ADNA-EcardconnecteddirectlytotheSC-BIKN2-Ecard,itispossibletoconnecttheunittotheSuperlinkIInetworkandcentralisemanagementofunits(SRK,SRR,SRF)usingremotecontrolsforallfunctions.Theinterfacecardiscontainedinaboxfastenedtothewallmeasuring120x135x29mm.ThecardisalsoequippedwithaCnTconnector,whichenablestheunits(SRK,SRR,SRF)toexchangethedigitalinputs/outputswithanexternalcontrol.
Model Interface ControlsSRK ZSX-S(T)SRK ZS-S(T)SRK ZR-SSRF ZMX-SSRR ZM-S
SC-BIKN2-E RC-EX3RC-E5
Model Interface ControlsSRK ZSX-S(T)SRK ZS-S(T)SRK ZR-SSRF ZMX-SSRR ZM-SSRR 25~60 ZM-S
SC-BIKN2-ESC-ADNA-E
RC-E5RC-EX3Centralised
FD unit (no KX) SC-ADNA-E Centralised
Wired remote control connectionSuperlink II connection
This interface card makes it possible to connect the indoor units to the Superlink II network,thusensuringtheycanbemanagedusingtheSC-SL2N-Edeviceandothercentralisers.Functions:•TransmissionofSuperlink IIdatabus informationdirectedtowardsthe indoorunitsconnected;
•Abilitytoblockthesettingsofthesingleindoorunitsfromacentraliser(remote);•TransmissionofthesignalshowinganyfaultswiththeindoorunitsconnectedtotheSuperlinkIIdevice,displayinganerrorcode.
Output start/stop command
Terminal board
SC-BIKN2-E OPTIONAL KIT
TheSC-GIFN-E interfacecardconnectedtothecentralisedMitsubishiSC-SL1N-E,SC-SL2NA-E and SC-SL4-AE/BE control systems, lets you control the switching on andoff of other equipment, including non-Mitsubishi devices (telephone dialler, homeautomationsystems,etc.).
SC-GIFN-E OPTIONAL KIT
Printed circuit board
Fault signal input
Operating signal input Network
Network lineFrom A to B on the following devices:SC-SL1N-E,SC-SL2NA-E,SC-SL4-AE/BE
Network address setting switchSets addresses for the devices:SC-SL1N-ESC-SL2NA-ESC-SL4-AE/BE
10 spaces1 space
100 spaces
DIGITAL INTERFACES USER DIAGRAM
SUPERLINKII
Controls
209
Any device or system applied inside or outside buildings must be able to enter into an automation logic. This aspect is even more important in systems where energy performance and consumption can be further improved by managing Home andBuildingAutomationtechniques,bybothcoordinatingthe various technologies available and by using energy wisely. Inaddition,thankstoavailableoperatingdata(consumption,timeprofiles,etc.),wecanquantifyrealsavingsandverifywhichimprovements can be achieved by changing management strategies.
KNX – OPEN STANDARD FOR ALL HOME & BUILDING AUTOMATION APPLICATIONS
KNXcanbeusedbothinnewbuildingsandduringrenovationin the residential and services sectors. All automation system componentscommunicatewithoneanotherwiththeKNXbus,independentofanysinglemanufacturerandanyparticularapplication.Themeansusedisaneasytoinstalltwistedpair,orIP/Ethernet.Busdevicescanbesensorsoractuatorsrequiredtocontrolairconditioning(hot/cold)whichwillbeintegratedwithlightingmanagement,blindandshuttermanagement,safetysystems,energymanagement,ventilationsystems,signalsandmonitoringincludingremotely,metering,audio/videocontrol,householdappliances,etc.Allthesefunctionscanbecontrolled,monitoredandreportedviaasinglesystemwithnoneed for additional control centres.
KNX: A SINGLE APPROACH WITH MANY ADVANTAGES
1. LOW OPERATING COSTS, CONSIDERABLE ENERGY SAVINGS
Operationisonlyactivatedwhenactuallynecessary,forexampleaccordingtotimeprofilesand/oractualpresence,thus saving energy and money.
2. SAVING TIME
Connecting all devices with a single Bus considerably reduces design and installation time. A single program independent of themanufacturerandapplication,EngineeringToolSoftware(ETS),allowsthedesign,engineeringandconfigurationofsystemscontainingKNX-certifiedproducts.Asthetoolisindependentofasinglemanufacturer,asystemintegratoris able to use a combination of products from different manufacturerswithdifferenttransmissionmedia(twistedpair,radiofrequency,powerlineorIP/Ethernet)inasinglesystem.
3. FLEXIBILITY AND ADAPTABILITY TO FUTURE DEVELOPMENTS
AKNXsystemcaneasilybeadaptedtonewapplicationsandiseasilyextendable.NewcomponentscansimplybeconnectedtotheexistingBussystem.
Lighting Blinds and shutters
Safetysystems
Energymanage-
ment
HVACsystems
Monitoring systems
Remote control
Metering Audio/videocontrol
Household appliances
HOME&BUILDINGAUTOMATION-INTESIS-BMSINTERFACES
Mitsubishi Heavy Industries, always very attentive to meeting market needs, has developed some interfaces which allow air conditioning system integration with home & building automation.
210
MH-RC-KNX-1i
MH-RC-KNX-1i (Master) MH-RC-KNX-1i (Slave)
TOUCH SCREEN
HVCA
RC-E5 RC-E5 RC-E5
TOUCH SCREEN
HVCA
TOUCH SCREEN
HVCA
RC-E5
RC-E5
BymeansoftheMH-RC-KNX-1i,MH-AC-KNX-48,andMH-AC-KNX-128interfaces,itispossibletointegrateMitsubishi Heavy Industries units with supervision that uses the KNXstandard.
Exampleofintegrationofacommercialunitwithindividualcontrol
Lighting
Energymanagement
Blinds and shutters
Lighting
Energymanagement
Blinds and shutters
Security systems
ExampleofintegrationinaKXZsystem,withbothtypeIandtypeIISuperlink
MH-AC-KNX-48(Max48IUs/SuperlinkIandII)MH-AC-KNX-128(Max128IUs/SuperlinkII)
INTEGRATED GATEWAY
Safety systems
Blinds and shutters
Lighting Energymanagement
HOME&BUILDINGAUTOMATION-INTESIS-BMSINTERFACES
KNX
Security systems
211
MH-RC-MBS-1
MH-RC-BMS-1 (Master) MH-RC-BMS-1 (Slave)
MODBUS
RC-E5 RC-E5 RC-E5
MODBUS MODBUS
MODBUS PROTOCOL
TheMODBUSprotocolisamaster/slavecommunicationbusoperatingonanRS-485(MODBUSRTUorMODBUSASCII)seriallineoronEthernet(MODBUSTCP/IP).TheMaster(Client)equipmentisPCsorcontrollers,whiletheSlaves(Servers)aredevicesusedtodetectsignalsfromthefieldortointerveneinthesystemtobeanalysed(DAT3000series).TheMasterequipmentsendspacketsofdata(queries)totheSlaves.AseachSlavedeviceisprogrammedwithauniqueaddress,onlytheSlavebeingqueriedwillrespondwiththedatarequested.TheMODBUSprotocoldefinestheformatofthequery,whichcontainsaddressoftheslavebeingqueried,afunctioncodethatdefinestherequestedaction,variousfieldsforexchangingtheactualdata(registers,coilsetc.)andafieldthatchecks for communication errors.
BymeansoftheMH-RC-MBS-1,MH-AC-MBS-48,andMH-AC-MBS-128interfaces,itispossibletointegrateMitsubishi Heavy Industries units with supervision that uses the Modbus standard.
Exampleofintegrationofacommercialunitwithindividualcontrol
ExampleofintegrationinaKXZsystem,withbothtypeIandtypeIISuperlink
MH-AC-MBS-48(Max48IUs/SuperlinkIandII)MH-AC-MBS-128(Max128IUs/SuperlinkII)
INTEGRATED GATEWAY
HOME&BUILDINGAUTOMATION-INTESIS-BMSINTERFACES
212
MH-RC-ENO-1
MH-RC-ENO-1 (Master) MH-RC-ENO-1 (Slave)
Paper
ENOCEAN PROTOCOL
Theexclusivesynergybetweenminiaturisedenergyconvertersandreliableradiotechnologygivesrisetoradiosensorsolutionsthatreducecostsandsaveenergyinbuildings(functionalandresidential)andinindustrialsystems,thankstotheirflexibilityandthefactthatnomaintenanceisrequired:
•BUILDINGAUTOMATION:themainwayofobtaininghighenergysavingsandreducingrunningcosts.Inaddition,increasinglystringentsafety,protectionandcomfortrequirementsaresatisfied.
•WIRELESSRADIOTECHNOLOGY:theenginebehindinnovationinbuildingautomationthatmakesitpossibletodefinethenumber,functionandflexibilityofthesensorsrequired.Radiotechnologyreducesinstallationtimesandsystemcosts.
•THEABSENCEOFBATTERIES:amustinlargeinstallations.Inthepresenceoffaultybatteries,thepercentageofsystemfailureincreasesexponentially,asdothecostsformaintenanceanddisposalofbatteries.EnOceanradiotechnologywithoutbatteriesisenvironmentallyfriendlyandefficientintermsofgreenbuildinganddoesnotaffectmajorenergysources.
BymeansoftheMH-RC-ENO-1interface,itispossibletointegrate Mitsubishi Heavy Industries units with supervision that uses the EnOcean standard.
Exampleofintegrationofacommercialunitwithindividualcontrol
Switch Thermostat Motion sensorSwitch Thermostat Paper Motion sensor
HOME&BUILDINGAUTOMATION-INTESIS-BMSINTERFACES
213
top related