cause of alarm 1 on 6 3 sr-3 - vta tekniikka oy · 2020. 5. 5. · hourmeters 1 3 4 2 & 5 menu...

Post on 04-Sep-2020

0 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

MAIN MENU

ALARMS

NEXTEXIT SELECT

NO ALARMS

NO ALARMS0 OF 0 ALARMS

EXIT

ALARM 28

PRETRIP ABORT1 OF 1 ALARMS

EXIT CLEAR HELP

ALARM 28

PRETRIP ABORT1 OF 1 ALARMS

EXIT CLEAR HELP

MENU6 °C

3SET SENSORSGAUGES

POINT

.1

TK 55526-2-PC-EN (Rev. 1, 08-16) ©Thermo King Corporation

83 LowEngineCoolantTemperature84 RestartNull85 ForcedUnitOperation86 DischargePressureSensor87 SuctionPressureSensor89 CheckElectronicThrottlingValveCircuit90 ElectricOverload91 ElectricReadyInput92 SensorGradesNotSet93 LowCompressorSuctionPressure94 Loader#1Circuit95 Loader#2Circuit96 LowFuelLevel98 FuelLevelSensor99 HighCompressorPressureRatio108 DoorOpenTime-out111 UnitNotConfiguredCorrectly113 ElectricHeatCircuit114 MultipleAlarms-CannotRun115 CheckHighPressureCutoutSwitch116 CheckHighPressureCutInSwitch117 AutoSwitchfromDieseltoElectric118 AutoSwitchfromElectrictoDiesel120 AlternatorExciterCircuit121 LiquidInjectionCircuit122 Diesel/ElectricRelayCircuit127 SetpointNotEntered128 EngineRunTimeMaintenanceReminder#1129 EngineRunTimeMaintenanceReminder#2130 ElectricRunTimeMaintenanceReminder#1131 ElectricRunTimeMaintenanceReminder#2132 TotalUnitRunTimeMaintenanceReminder#1133 TotalUnitRunTimeMaintenanceReminder#2134 ControllerPowerOnHours135 CheckSpareDigitalInputs136 CheckSpareDigitalOutputs137 CheckDamperMotorHeaterOutput141 AutoswitchDieseltoElectricDisabled145 LossofController“On”FeedbackSignal146 SoftwareVersionMismatch148 AutoswitchElectrictoDieselDisabled149 AlarmNotIdentified150 OutofRangeLow151 OutofRangeHigh157 OptiSetPlusMismatch158 Softwarefailedtoload203 DisplayReturnAirSensor204 DisplayDischargeAirSensor252 CheckFreshAirExchangeCircuit

HÄLYTYSTEN TARKISTELU SIMPLE TO DETERMINE

CauseofAlarm

2

1

4

6

3

5

7

13

2

1. Palaa perusnäyttöön.2. Paina VALIKKO näppäintä.3. Paina SEURAAVA näppäintä kunnes

näytössä on hälytysvalikko.4. Paina VALITSE hälytysvalikko aukeaa

5. Jos hälytyksiä ei ole näytössä lukee EI HÄLYTYKSIÄ

6. Paina POISTU palataksesi perusnäyttöön

7. Jos hälytyksiä on aktiivisena, hälytysten lukumäärä ja viimeisin hälytyskoodi on näytössä

8. Jos hälytyksiä on useampi, paina SEURAAVA tarkastellaksesi niitä.

9. Jos mikroprosessori havaitsee vakavan ongelman laitteessa, se pysäyttää laitteen lisävahinkojen ehkäsemiseksi. Jos näin tapahtuu, on näytössä ilmoitus laitteen pysäyttämisestä ja hälytyskoodi. Hälytys voi olla myös ns. tarkistushälytys joka näkyy näytöllä mutta ei sammuta laitetta.Vakavan ongelman hälytyksen sattuessa ota aina yhteyttä ensin Thermo King huoltoon ennen kun kuittaat hälytyksen.

1. Paina POISTA näppäintä kuitataksesi hälytyskoodin.

2. Näyttö palautuu perusnäyttöön kun kaikki mahdolliset hälytykset on kuitattu.

3. PresstheHELPkeyforadditionalinformationwnonthedisplay.Also seethecompleteAlarmCodelistinthenextcolumn.

4. Huom. Joitain koodeja ei saa kuitattua HÄLYTYKSET valikosta tai koodi palaa heti takaisin. Ota silloin yhteyttä valtuutettuun Thermo King huoltoon.

0 NoAlarmsExist2 EvaporatorCoilSensor3 ControlReturnAirSensor4 ControlDischargeAirSensor5 AmbientAirSensor6 CoolantTempSensor7 EngineRPMSensor9 HighEvaporatorTemperature10 HighDischargePressure11 UnitControllingonAlternateSensor12 SensororDigitalInputShutdown13 SensorCheck15 CheckGlowPlugs/IntakeAirHeater17 EngineFailedtoCrank18 HighEngineCoolantTemperature19 LowEngineOilPressure20 EngineFailedtoStart21 CoolingCycleCheck22 HeatingCycleCheck23 CoolingCycleFault24 HeatingCycleFault25 AlternatorCheck26 RefrigerationCapacity28 PretriporSelfCheckAbort29 DefrostDamperCircuit30 DefrostDamperStuck31 OilPressureSwitch32 RefrigerationCapacityLow33 CheckEngineRPM35 RunRelayCircuit36 ElectricMotorFailedtoRun37 EngineCoolantLevel38 ElectricPhaseReversed39 WaterValveCircuit40 HighSpeedCircuit41 CheckEngineCoolantTemperature42 UnitForcedtoLowSpeed43 UnitForcedtoLowSpeedModulation44 CheckFuelSystem45 HotGasBypassorHotGasBypassCircuit46 CheckAirFlow48 CheckBelts/Clutch50 ResetClock52 HeatCircuit54 TestModeTime-out61 LowBatteryVoltage62 AmmeterOutofCalibration63 EngineStopped64 PretripReminder65 AbnormalTemperatureDifferential66 LowEngineOilLevel67 LiquidLineSolenoidCircuit68 InternalControllerFault70 HourmeterFailure74 ControllerResettoDefaults77 ControllerEPROMChecksumFailure79 InternalDataLoggerOverflow80 CompresorTempSensor81 HighCompressorTemp82 HighCompressorTemperatureShutdown

HÄLYTYSTEN KUITTAUS

Käyttäjän pikaopas

SR-3Smart Reefer 3Microprocessor

NOTE: For more detailed information on each action, see the Operation chapter in the appropriate unit operating manual.

Formoreinformationortutorial

sessions,pleasecontactyour

ThermoKingServiceManager

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINT

OFF

ON

MENU6 °C

3SET SENSORSGAUGES

POINTMENU6 °C

3SET SENSORSGAUGES

POINT

.1

PROGRAMMING DEFROST

PLEASE WAIT

MAIN MENU

PRETRIP

NEXTEXIT SELECT BACK

TOTAL RUN TIME HOURS

78NEXTEXIT BACK

3MENUSET SENSORSGAUGES

POINTEXIT

PRETRIPPASS

- EXIT

CURRENT SETPOINT

3 C

++/- TO CHANGE

- NO

NEW SETPOINT WILL BE

4 C

++/- TO CHANGE OK?YES

MENU2 °C

4SET SENSORSGAUGES

POINT

.1

2 2

1 1

ENGINE RPM

1457NEXTEXIT LOCK

RPM

BACK

ENGINE RPM

1457NEXTEXIT LOCK

RPM

BACK

4 45 53 3

5

3 & 5

7

3 3

43

4

2

1

3

1

4

1. PresstheONKey.2. Aseriesofstart-upscreenswill

appear.3. Whentheunitisreadytorun

theStandardDisplayofBoxTemperatureandSetpointwillappear.

4. TheStandardDisplaydefaultstothe“TemperatureWatch”screenafter21/2minutes.Thisscreendisplayssamesetpointandboxtemperatureinlargerfont.

1. ReturntotheStandardDisplay.2. PresstheSETPOINTKeyonthe

StandardDisplay.3. Pressthe+or-Keystochangethe

setpointreading.4. PresstheYESKeywhenthedesired

setpointisshown.5. TheStandardDisplayappears

withsetpointchangedtothenewsetpoint.

1. ReturntotheStandardDisplay.2. PresstheMODESELECTIONKey.

IMPORTANT: As of several years ago, the display no longer shows test at the top of the display to indicate “Cycle Sentry” or “Continuous”.

3. IftheunitisinCycleSentry,the“CycleSentryIcon”willappearintheupperrightcornerofthedisplayasshown.

4. IftheunitisinContinuoustheCycleSentryIconwillnotbepresent.

5. PressingtheMODESELECTIONKeyagainwillchangetheunitbacktothepreviousmode.

SIMPLE TO START

SIMPLE TO SET

CYCLE-SENTRYorContinuousRun

SIMPLE TO SET

SetpointTemperature

SIMPLE TO CHECK

Gauges

SIMPLE TO DEFROST

InitiateManualDefrost

SIMPLE TO ACCESS

Sensors

SIMPLE TO CHECK

PretripTest

SIMPLE TO CHECK

Hourmeters

1

3

4

2 & 5

MENU6 °C

3SET SENSORSGAUGES

POINT

.1

3

4

5

2

1

1. ReturntotheStandardDisplay.2. PresstheDEFROSTKey.3. Aseriesofdefrostscreenswill

appear.4. TheDefrostDisplayappears.The

barindicatorwillfillinshowingthetimeremainingtocompletetheDefrostcycle.WhentheDefrostcycleiscompletethedisplayreturnstoStandardDisplay.

12

2

3

NOTE: For more detailed information on each action, see the Operation chapter in the appropriate unit operating manual.

1. ReturntotheStandardDisplay.2. PresstheGAUGESKey.3. PressBACKorNEXTKeystoscroll

throughfollowinggauges:CoolantTemperature,CoolantLevel,EngineOil,Pressure,Amps,BatteryVoltage,EngineRPM,DischargePressure,SuctionPressure,ETVPosition,I/O.Ifnokeysarepressedwithin30seconds,thescreenwillreturntotheStandardDisplay.

4. PresstheLOCKKeytodisplayanygaugescreenfor15minutes.Pressthekeyagaintounlockthescreen.

1. Clearallalarmcodes.2. ReturntotheStandardDisplay.3. PresstheMENUkey.4. PresstheNEXTKeyasrequiredto

showthePretripMenu.5. PresstheSELECTKeytostarta

PretripTest.6. Iftheunitisnotrunning,aFull

Pretripwillbeinitiated.Iftheunitisrunningineitherdieselorelectricmode,aRunningPretripwillbeperformed.

7. Whenalltestsarecomplete,theresultsarereportedasPASS,CHECKorFAIL.IftheresultsareCHECKorFAIL,theaccompanyingalarmcodeswilldirectthetechniciantothecauseoftheproblem.

1. ReturntotheStandardDisplayscreen.

2. PresstheMENUKey.3. ScrollthroughMainMenuby

repeatedlypressingtheNEXTandBACKKeysuntilthehourmetersMainMenuScreenappears.

4. PresstheSELECTKeytoentertheHourmetersMenu.

5. PresstheNEXTandBACKKeystoviewtheHourmeterDisplays.

1. ReturntotheStandardDisplay.2. PresstheSENSORSKey.3. PresstheBACKorNEXTKeys

toscrollthroughthefollowingsensorscreens:ControlReturnAirTemperature,DisplayReturnAirTemperature,ControlDischargeAirTemperature,DisplayDischargeAirTemperature,TemperatureDifferential,EvaporatorCoilTemperature,AmbientAirTemperature,Spare1Temperature,DataloggerTemperatureSensors1-6andtheBoardTemperature

Sensor.Ifnokeysarepressedwithin30seconds,thescreenwillreturntotheStandardDisplay.

4. PresstheLOCKKeytodisplayanysensorscreenforfor15minutes.Pressthekeyagaintounlockthescreen.

5. PresstheEXITKeytoreturntotheStandardDisplay.

5. PresstheEXITKeytoreturntotheStandardDisplay.

NOTE: You must select the YES key within 10 seconds of selecting the new Setpoint, otherwise the change will be cancelled.

top related