cause of alarm 1 on 6 3 sr-3 - vta tekniikka oy · 2020. 5. 5. · hourmeters 1 3 4 2 & 5 menu...
TRANSCRIPT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
MAIN MENU
ALARMS
NEXTEXIT SELECT
NO ALARMS
NO ALARMS0 OF 0 ALARMS
EXIT
ALARM 28
PRETRIP ABORT1 OF 1 ALARMS
EXIT CLEAR HELP
ALARM 28
PRETRIP ABORT1 OF 1 ALARMS
EXIT CLEAR HELP
MENU6 °C
3SET SENSORSGAUGES
POINT
.1
TK 55526-2-PC-EN (Rev. 1, 08-16) ©Thermo King Corporation
83 LowEngineCoolantTemperature84 RestartNull85 ForcedUnitOperation86 DischargePressureSensor87 SuctionPressureSensor89 CheckElectronicThrottlingValveCircuit90 ElectricOverload91 ElectricReadyInput92 SensorGradesNotSet93 LowCompressorSuctionPressure94 Loader#1Circuit95 Loader#2Circuit96 LowFuelLevel98 FuelLevelSensor99 HighCompressorPressureRatio108 DoorOpenTime-out111 UnitNotConfiguredCorrectly113 ElectricHeatCircuit114 MultipleAlarms-CannotRun115 CheckHighPressureCutoutSwitch116 CheckHighPressureCutInSwitch117 AutoSwitchfromDieseltoElectric118 AutoSwitchfromElectrictoDiesel120 AlternatorExciterCircuit121 LiquidInjectionCircuit122 Diesel/ElectricRelayCircuit127 SetpointNotEntered128 EngineRunTimeMaintenanceReminder#1129 EngineRunTimeMaintenanceReminder#2130 ElectricRunTimeMaintenanceReminder#1131 ElectricRunTimeMaintenanceReminder#2132 TotalUnitRunTimeMaintenanceReminder#1133 TotalUnitRunTimeMaintenanceReminder#2134 ControllerPowerOnHours135 CheckSpareDigitalInputs136 CheckSpareDigitalOutputs137 CheckDamperMotorHeaterOutput141 AutoswitchDieseltoElectricDisabled145 LossofController“On”FeedbackSignal146 SoftwareVersionMismatch148 AutoswitchElectrictoDieselDisabled149 AlarmNotIdentified150 OutofRangeLow151 OutofRangeHigh157 OptiSetPlusMismatch158 Softwarefailedtoload203 DisplayReturnAirSensor204 DisplayDischargeAirSensor252 CheckFreshAirExchangeCircuit
HÄLYTYSTEN TARKISTELU SIMPLE TO DETERMINE
CauseofAlarm
2
1
4
6
3
5
7
13
2
1. Palaa perusnäyttöön.2. Paina VALIKKO näppäintä.3. Paina SEURAAVA näppäintä kunnes
näytössä on hälytysvalikko.4. Paina VALITSE hälytysvalikko aukeaa
5. Jos hälytyksiä ei ole näytössä lukee EI HÄLYTYKSIÄ
6. Paina POISTU palataksesi perusnäyttöön
7. Jos hälytyksiä on aktiivisena, hälytysten lukumäärä ja viimeisin hälytyskoodi on näytössä
8. Jos hälytyksiä on useampi, paina SEURAAVA tarkastellaksesi niitä.
9. Jos mikroprosessori havaitsee vakavan ongelman laitteessa, se pysäyttää laitteen lisävahinkojen ehkäsemiseksi. Jos näin tapahtuu, on näytössä ilmoitus laitteen pysäyttämisestä ja hälytyskoodi. Hälytys voi olla myös ns. tarkistushälytys joka näkyy näytöllä mutta ei sammuta laitetta.Vakavan ongelman hälytyksen sattuessa ota aina yhteyttä ensin Thermo King huoltoon ennen kun kuittaat hälytyksen.
1. Paina POISTA näppäintä kuitataksesi hälytyskoodin.
2. Näyttö palautuu perusnäyttöön kun kaikki mahdolliset hälytykset on kuitattu.
3. PresstheHELPkeyforadditionalinformationwnonthedisplay.Also seethecompleteAlarmCodelistinthenextcolumn.
4. Huom. Joitain koodeja ei saa kuitattua HÄLYTYKSET valikosta tai koodi palaa heti takaisin. Ota silloin yhteyttä valtuutettuun Thermo King huoltoon.
0 NoAlarmsExist2 EvaporatorCoilSensor3 ControlReturnAirSensor4 ControlDischargeAirSensor5 AmbientAirSensor6 CoolantTempSensor7 EngineRPMSensor9 HighEvaporatorTemperature10 HighDischargePressure11 UnitControllingonAlternateSensor12 SensororDigitalInputShutdown13 SensorCheck15 CheckGlowPlugs/IntakeAirHeater17 EngineFailedtoCrank18 HighEngineCoolantTemperature19 LowEngineOilPressure20 EngineFailedtoStart21 CoolingCycleCheck22 HeatingCycleCheck23 CoolingCycleFault24 HeatingCycleFault25 AlternatorCheck26 RefrigerationCapacity28 PretriporSelfCheckAbort29 DefrostDamperCircuit30 DefrostDamperStuck31 OilPressureSwitch32 RefrigerationCapacityLow33 CheckEngineRPM35 RunRelayCircuit36 ElectricMotorFailedtoRun37 EngineCoolantLevel38 ElectricPhaseReversed39 WaterValveCircuit40 HighSpeedCircuit41 CheckEngineCoolantTemperature42 UnitForcedtoLowSpeed43 UnitForcedtoLowSpeedModulation44 CheckFuelSystem45 HotGasBypassorHotGasBypassCircuit46 CheckAirFlow48 CheckBelts/Clutch50 ResetClock52 HeatCircuit54 TestModeTime-out61 LowBatteryVoltage62 AmmeterOutofCalibration63 EngineStopped64 PretripReminder65 AbnormalTemperatureDifferential66 LowEngineOilLevel67 LiquidLineSolenoidCircuit68 InternalControllerFault70 HourmeterFailure74 ControllerResettoDefaults77 ControllerEPROMChecksumFailure79 InternalDataLoggerOverflow80 CompresorTempSensor81 HighCompressorTemp82 HighCompressorTemperatureShutdown
HÄLYTYSTEN KUITTAUS
Käyttäjän pikaopas
SR-3Smart Reefer 3Microprocessor
NOTE: For more detailed information on each action, see the Operation chapter in the appropriate unit operating manual.
Formoreinformationortutorial
sessions,pleasecontactyour
ThermoKingServiceManager
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINTMENU6 °C
3SET SENSORSGAUGES
POINT
.1
PROGRAMMING DEFROST
PLEASE WAIT
MAIN MENU
PRETRIP
NEXTEXIT SELECT BACK
TOTAL RUN TIME HOURS
78NEXTEXIT BACK
3MENUSET SENSORSGAUGES
POINTEXIT
PRETRIPPASS
- EXIT
CURRENT SETPOINT
3 C
++/- TO CHANGE
- NO
NEW SETPOINT WILL BE
4 C
++/- TO CHANGE OK?YES
MENU2 °C
4SET SENSORSGAUGES
POINT
.1
2 2
1 1
ENGINE RPM
1457NEXTEXIT LOCK
RPM
BACK
ENGINE RPM
1457NEXTEXIT LOCK
RPM
BACK
4 45 53 3
5
3 & 5
7
3 3
43
4
2
1
3
1
4
1. PresstheONKey.2. Aseriesofstart-upscreenswill
appear.3. Whentheunitisreadytorun
theStandardDisplayofBoxTemperatureandSetpointwillappear.
4. TheStandardDisplaydefaultstothe“TemperatureWatch”screenafter21/2minutes.Thisscreendisplayssamesetpointandboxtemperatureinlargerfont.
1. ReturntotheStandardDisplay.2. PresstheSETPOINTKeyonthe
StandardDisplay.3. Pressthe+or-Keystochangethe
setpointreading.4. PresstheYESKeywhenthedesired
setpointisshown.5. TheStandardDisplayappears
withsetpointchangedtothenewsetpoint.
1. ReturntotheStandardDisplay.2. PresstheMODESELECTIONKey.
IMPORTANT: As of several years ago, the display no longer shows test at the top of the display to indicate “Cycle Sentry” or “Continuous”.
3. IftheunitisinCycleSentry,the“CycleSentryIcon”willappearintheupperrightcornerofthedisplayasshown.
4. IftheunitisinContinuoustheCycleSentryIconwillnotbepresent.
5. PressingtheMODESELECTIONKeyagainwillchangetheunitbacktothepreviousmode.
SIMPLE TO START
SIMPLE TO SET
CYCLE-SENTRYorContinuousRun
SIMPLE TO SET
SetpointTemperature
SIMPLE TO CHECK
Gauges
SIMPLE TO DEFROST
InitiateManualDefrost
SIMPLE TO ACCESS
Sensors
SIMPLE TO CHECK
PretripTest
SIMPLE TO CHECK
Hourmeters
1
3
4
2 & 5
MENU6 °C
3SET SENSORSGAUGES
POINT
.1
3
4
5
2
1
1. ReturntotheStandardDisplay.2. PresstheDEFROSTKey.3. Aseriesofdefrostscreenswill
appear.4. TheDefrostDisplayappears.The
barindicatorwillfillinshowingthetimeremainingtocompletetheDefrostcycle.WhentheDefrostcycleiscompletethedisplayreturnstoStandardDisplay.
12
2
3
NOTE: For more detailed information on each action, see the Operation chapter in the appropriate unit operating manual.
1. ReturntotheStandardDisplay.2. PresstheGAUGESKey.3. PressBACKorNEXTKeystoscroll
throughfollowinggauges:CoolantTemperature,CoolantLevel,EngineOil,Pressure,Amps,BatteryVoltage,EngineRPM,DischargePressure,SuctionPressure,ETVPosition,I/O.Ifnokeysarepressedwithin30seconds,thescreenwillreturntotheStandardDisplay.
4. PresstheLOCKKeytodisplayanygaugescreenfor15minutes.Pressthekeyagaintounlockthescreen.
1. Clearallalarmcodes.2. ReturntotheStandardDisplay.3. PresstheMENUkey.4. PresstheNEXTKeyasrequiredto
showthePretripMenu.5. PresstheSELECTKeytostarta
PretripTest.6. Iftheunitisnotrunning,aFull
Pretripwillbeinitiated.Iftheunitisrunningineitherdieselorelectricmode,aRunningPretripwillbeperformed.
7. Whenalltestsarecomplete,theresultsarereportedasPASS,CHECKorFAIL.IftheresultsareCHECKorFAIL,theaccompanyingalarmcodeswilldirectthetechniciantothecauseoftheproblem.
1. ReturntotheStandardDisplayscreen.
2. PresstheMENUKey.3. ScrollthroughMainMenuby
repeatedlypressingtheNEXTandBACKKeysuntilthehourmetersMainMenuScreenappears.
4. PresstheSELECTKeytoentertheHourmetersMenu.
5. PresstheNEXTandBACKKeystoviewtheHourmeterDisplays.
1. ReturntotheStandardDisplay.2. PresstheSENSORSKey.3. PresstheBACKorNEXTKeys
toscrollthroughthefollowingsensorscreens:ControlReturnAirTemperature,DisplayReturnAirTemperature,ControlDischargeAirTemperature,DisplayDischargeAirTemperature,TemperatureDifferential,EvaporatorCoilTemperature,AmbientAirTemperature,Spare1Temperature,DataloggerTemperatureSensors1-6andtheBoardTemperature
Sensor.Ifnokeysarepressedwithin30seconds,thescreenwillreturntotheStandardDisplay.
4. PresstheLOCKKeytodisplayanysensorscreenforfor15minutes.Pressthekeyagaintounlockthescreen.
5. PresstheEXITKeytoreturntotheStandardDisplay.
5. PresstheEXITKeytoreturntotheStandardDisplay.
NOTE: You must select the YES key within 10 seconds of selecting the new Setpoint, otherwise the change will be cancelled.