Calculations of 3D Weighting Field Profiles for 3D Detectors. Zheng Li G. Carini, M. Li. 3rd Workshop on Advanced Silicon Radiation Detectors (3D and P-type Technologies, Barcelona, Spain, April 14-16, 2004. BNL 3D detector: 1 column design. n + (column),0. p + , 0. p + (implant),0. - PowerPoint PPT Presentation

TRANSCRIPT

Calculations of 3D Weighting Field Profiles for 3D Detectors

Zheng Li

G. Carini, M. Li

3rd Workshop on Advanced Silicon Radiation Detectors (3D and P-type Technologies, Barcelona, Spain, April 14-16, 2004

BNL 3D detector: 1 column design

n+ , the collecting electrode column, 1

p+ (implant),0

p+ , 0

Weighting Field (1/cm)

n+ (column),0

cut plane @ 1um cut plane @ 2um

cut plane @ 4um cut plane @ 10um

n+ n+

n+ n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting field highest near the surface

cut plane @ 20um

cut plane @ 50um

cut plane @ 30um

cut plane @ 70um

n+ n+

n+ n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting field highest near the collecting n+ column, lowest under p+ electrodes,and is at ½ strength in the middle (non-zero)

cut plane @ 150um cut plane @ 250um

cut plane @ 268um cut plane @ 271um

n+ n+

n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

Cutline

CutlineWeighting Field (1/cm)

Potential

cut plane @ 280um

cut plane @ 300um

cut plane @ 290um

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Some weighting field still exists near the unprocessed back side (non-zero)

BNL 3D detector: 2 columns design

n+ , the collecting electrode column, 1

n+ (column)

p+ (column)

p+

Weighing field (1/cm)

cut plane @ 0um cut plane @ 150um

cut plane @ 250um cut plane @ 268um

n+ n+

n+ n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting field highest near the collecting n+ column, lowest between p+ columnsAnd non-collecting n+ column, and is at about ½ strength in the middle (non-zero)

Cutline Weighting Field (1/cm)

cut plane @ 271um cut plane @ 275um

cut plane @ 278um cut plane @ 281um

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

cut plane @ 285um cut plane @ 290um

cut plane @ 300um

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Some weighting field still exists near the unprocessed back side (non-zero)

3D detector: BNM/ITC - IRST

n+ , the collecting electrode column

n+ (column)

p+ (column)

p+

cut plane @ 0um

cut plane @ 12um

cut plane @ 7um

cut plane @ 17um

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm)Weighting Field (1/cm)

Weighting field lowest near the surface of p+ columns

cut plane @ 18um

cut plane @ 24um

cut plane @ 20um

cut plane @ 28um

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

cut plane @ 30um cut plane @ 50um

cut plane @ 150um cut plane @ 250um

n+ n+

n+ n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting field highest near the collecting n+ column, lowest between p+ columnsAnd non-collecting n+ column, and is at about ½ strength in the middle (non-zero) (same)

Cutline

cut plane @ 269um cut plane @ 271um

cut plane @ 280umcut plane @ 273um

n+ n+

n+ n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting Field (1/cm)

cut plane @ 285um

cut plane @ 300um

cut plane @ 290um

n+ n+

n+

Weighting Field (1/cm) Weighting Field (1/cm)

Weighting Field (1/cm) Weighting field at the surface of n+ columns is similar to that of the STC 3D detector

Summary Weighting field in 3D detectors is highly non-uniform

But it is distributed all throughout the detector (for pitch 50 µm) In the middle of the cell (between 4 columns), the weighting field is about half of the maximum

So the main limiting factor for CEE in 3D detectors may be electric fields