boq electrical
Post on 06-Apr-2018
409 Views
Preview:
TRANSCRIPT
-
8/3/2019 Boq Electrical
1/22
C
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C
C1 Non-sch commissioning of free standing, floor
mounted indoor type, air insulated, totally
enclosed vermin proof, dead front,compartmentalised, cubicle type, 2 mm
thick sheet steel enclosure panel suitable
for use on 415 V, 3 Ph.,4 wire, 50 Hz. A.C.
system, incoming circuit breaker/ S F unit,
high conductivity TP & N Aluminium bus
bars, bus bar, risers, extended bus bars
for cable connection, outgoing circuit
breakers instrumental panel, C.Ts,
outgoing feeder terminals and incomingcable compartment. The incoming and
outgoing functional units shall be arranged
in multi tier formation to provide a
compact panel. Each unit shall be
accommodated in a totally separate
compartment having gasketted hinged
door
INTERNAL ELECTRIFICATION WORKSRate Amount (TOTAL)
HEAD: ELECTRICAL WORKS
ELECTRICAL PANELS
ELECTRICAL: Page 1
-
8/3/2019 Boq Electrical
2/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR with locking arrangement. The Panel shall
be complete with switches/circuit breakers
of following ratings, interconnection, G.I.
earth bus bar of adequate size covering
the total length of switch board with drilled
holes, G.I. bolts, nuts, washers etc. The
cubicle should be painted with two (2)
coats of light grey synthetic enamel paint
over two coats of zinc chromate primer.The complete fabrication, construction
shall be done as
per the detailed specification and
conforming to the
relevant IS. Short circuit interrupting
current of all MCBss ou e o m n mum. ame p ate
of
Panels/DBs Danger Board, incoming and
outgoing
feeders with Ampere rating of switches/
MCCB/ MCB
etc. are to be fixed up on front door above
or below the
respective switches. Approval ofManufacturer's
drawings from Consultant/Employer is
required before
commencing manufacture and panel
should be tested
in the presence of Consultant/ Employer's
engineer at
ELECTRICAL: Page 2
-
8/3/2019 Boq Electrical
3/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR manufacturer's premises before dispatch
to site.
C1a Non-schIncoming :
415 V400 A 50 KA 4pole MCCB (Relay
range 320-400 A) : 1 no.
Multifunction meter to observe
voltage/current/PF etc with sets of 400/5A
CT's ete. As reqd3 Nos. Phase Indicating lamp, 230 V3nos. protective fuse :PVC SLEEVED TPN ALUMINIUM BUS
BAR :100 mm x 8 mm for phases &50 mm x 6 mm for neutral.GI EARTH BUS BAR25 mm x 6 mm covering the total length of
panel.Outgoing :4 Nos.415 V 200 A, 35KA 4 pole MCCB
with relay range 160-200A.1 Nos.415 V 100 A, 25KA 4 pole MCCB
with relay range 80-100A.4 Nos.415 V 63 A, 25KA 4 pole MCCB
with relay range 50-63A. 1.00 No 350,000.000.00 350,000.00
C1a Non-schIncoming :415 V400 A 50 KA 4pole MCCB (Relay
range 250-320 A) : 1 no.Multifunction meter to observe
voltage/current/PF etc with sets of 300/5A
CT's ete. As reqd3 Nos. Phase Indicating lamp, 230 V3nos. protective fuse :
MAIN POWER DISTRIBUTION BOARD
MAIN POWER DISTRIBUTION BOARD
ELECTRICAL: Page 3
-
8/3/2019 Boq Electrical
4/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR PVC SLEEVED TPN ALUMINIUM BUS
BAR :75 mm x 8 mm for phases &50 mm x 6 mm for neutral.GI EARTH BUS BAR25 mm x 6 mm covering the total length of
panel.Outgoing :4 Nos.415 V 125 A, 35KA 4 pole MCCB
with relay range 100-125A. 1.00 208,600.000.00 208,600.00
C1b Non-schIncoming :415 V100 A25 KA 4pole MCCB (Relay
range 80-100 A) : 1 no.125A 4 pole 415V on load change over
switch-1no
Multifunction meter to observevoltage/current/PF etc with sets of 100/5A
CT's ete. As reqd3 Nos. Phase Indicating lamp, 230 V3nos. protective fuse :PVC SLEEVED TPN ALUMINIUM BUS
BAR :40 mm x 6 mm for phases &25 mm x 6 mm for neutral.
GI EARTH BUS BAR25 mm x 6 mm covering the total length of
panel.Outgoing :9 Nos.415 V 63 A, 10KA 4 pole MCB1 Nos.415 V 32 A, 10KA 4 pole MCB 1.00 No 108,000.00 0.00 108,000.00
MAIN LIGHT DISTRIBUTION BOARD
ELECTRICAL: Page 4
-
8/3/2019 Boq Electrical
5/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C1c Non-sch SUB MAIN POWER DISTRIBUTION
BOARD SMPDBIncoming :415 V 200 A 35 KA 4pole MCCB (Relay
range 160-200 A) : 1 no.Multifunction meter to observe
voltage/current/PF etc with sets of 200/5A
CT's ete. As reqd3 Nos. Phase Indicating lamp, 230 V3nos. protective fuse :PVC SLEEVED TPN ALUMINIUM BUS
BAR :50 mm x 8 mm for phases &25 mm x 6 mm for neutral.GI EARTH BUS BAR25 mm x 6 mm covering the total length of
panel.Outgoing :
5 Nos.415 V 100 A, 25KA 4 pole MCCBwith relay range 125-160A.1 Nos.415 V 63 A, 25KA 4 pole MCCB
with relay range 50-63A. 3.00 No 169,000.000.00 507,000.00
C1b Non-sch Area Lighting DBThe Road Lighting DB consists of the
following :
Incoming :1 no. 32A TPN MCBOutgoing :6 no. 16A/20A SP MCB1 no. time switch.( DAILY)1 no. 3 pole power contactor 40A1 set 4 pole 60A Al Bus Barcomplete with all interconnection 1.00 No 21,584.00 0.00 21,584.00
ELECTRICAL: Page 5
-
8/3/2019 Boq Electrical
6/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR SUPPLY AND FIXING OF TPN MCB DB
C2 2.33
TPMCB
DB
sheet steel MCB distribution board, 415V
on surface/ recessed, complete with
tinned copper Bus bar, neutral link, earth
bar, din bar, detachable grand plate,
interconnections, phosphatized powder
painted including earthing etc. as
required.(but without MCB/ RCCB/
Isolator)a 2.33.1
4 way (4+12, single door horizontal type) 8.00 nos 820.00
6,560.00 0.00
b 2.33.2
6 way (4+18, single door horizontal type) 1.00 nos 959.00
959.00 0.00
2.35
VTTPM
CBDB
Suppling, installation, testing and
commissioning of surface/ recessed
mounting, vertical type, 415V, TPNMCB
Distribution board of sheet steel, dustprotected, duly phophatised and powder
painted, inclussive of 200A tinned copper
bus bar, common neutral link, earth bar,
din bar for mounting MCB's, detachable
gland/ Knock out plate, and with 100A
10Ka MCCB as incomer, interconnection
between incomer MCCB and Busbars of
following ways (but with out MCBs) as
required.
2.35.2
8 way with 100A MCCB as incommer 16.00 no 3,553.00
56,848.00 0.00
SUPPLY AND FIXING OF SPN
CONSUMER UNIT
ELECTRICAL: Page 6
-
8/3/2019 Boq Electrical
7/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C3 2.32
SPMCB
DBCO
upp y ng an x ng o o ow ng waysheet steel MCB distribution board
consumer unit, 240V on surface/
recessed, complete with tinned copper
Bus bar, neutral link, earth bar, din bar,
hinged front acrylic cover for the MCB
knobs, detachable grand plate,
interconnections, phosphatized and
powder painted including painting,
earthing etc. as required.(but without
MCB, RCCB, Isolator).
a 2.32.1 2+4 way 1.00 each 559.00 559.00 0.00b 2.32.2 2+8 wat 4.00 each 654.00 2,616.00 0.00
SUPPLY AND FIXING OF 5A to 32A L
series MCB:
C4 2.52
MCBC Supplying and fixing 5amps to 32 amps
rating 240V, 'C' series, MCB suitable for
inductive load of following poles in the
existing MCB DB complete with
connections, testing and commissioning
etc. as required. (Category B)
a 2.52.1 Single Pole 342.00 each 94.00 32,148.00 0.00B 2.52.3 Triple pole 74.00 each 383.00 28,342.00 0.00
S/F DP MCB ISOLATORC5 2.54
MCBDP
IS
Supply and fixing following rating double
pole 240V, isolator in the existing MCB DB
complete with connections, testing and
commissioning etc as required.
2.54.1 40A 5.00 each 166.00 830.00 0.00
ELECTRICAL: Page 7
-
8/3/2019 Boq Electrical
8/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C6 2.55
MCBTP
IS S/F TP MCB ISOLATOR
Supply and fixing following rating 4 pole
400V, isolator in the existing MCB DB
complete with connections, testing and
commissioning etc as required.
2.55.2 63 A 12.00 each 362.00 4,344.00 0.00
C7 non-
schedul
e
Providing and fixing G.I. pipes complete
with G.I. fittings if required including
trenching and refilling etc.for cable
rotectiona 50 mm dia. Nominal bore 8.00 meter 450.00 0.00 3,600.00b 100 mm dia. Nominal bore 8.00 meter 1,100.00 0.00 8,800.00c 150 mm dia. Nominal bore 26.00 meter 1,600.00 0.00 41,600.00
DISTRIBUTION CABLE :SUPPLYING OF CABLE :
C8 non-
schedul
e
Supplying, Transportation & handling of
1.1 KV grade XLPE insulated and PVC
sheathed armoured aluminium conductor
cable of following size conforming of
IS:1554 (Part-I) :2 core 10 sq.mm. PVCA Al. Cable. 100.00 meter 215.00 0.00 21,500.00
a 4 core 16 sq.mm. PVCA Al. Cable. 100.00 meter 330.00 0.00 33,000.00b 4 core 10 sq.mm. PVCA Al. Cable. 90.00 meter 263.00 0.00 23,670.00c 3.5 core 300 sq.mm. PVCA Al. Cable. 60.00 meter 2,890.00 0.00 173,400.00d 3.5 core 35 sq.mm. PVCA Al. Cable. 300.00 meter 497.00 0.00 149,100.00e 3.5 core 150 sq.mm. PVCA Al. Cable. 40.00 meter 1,490.00 0.00 59,600.00f 3.5 core 70 sq.mm. PVCA Al. Cable. 60.00 meter 827.00 0.00 49,620.00g 3.5 core 50 sq.mm. PVCA Al. Cable. 150.00 meter 697.00 0.00 104,550.00
ELECTRICAL: Page 8
-
8/3/2019 Boq Electrical
9/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C9 1.1
MVCBG
R25 MV Cable Laying upto 25sqmm in ground:
Laying of 1 no. PVC insul and PVC
sheathed / XLPE cable of 1.1 KV grade
size not exceeding 25sqmm, direct in
ground including excavation, sand
cousioning, protective covering and
refilling the treanch etc as required. 120.00 meter 85.00
10,200.00 0.00
C10 1.2
MVCBG
R120
MV Cable Laying upto 120 sqmm in
ground:
Laying of 1 no. PVC insul and PVC
sheathed / XLPE cable of 1.1 KV grade
size exceeding 25sqmm but not
exceeding 120 sqmm, direct in ground
including excavation, sand cousioning,protective covering and refilling the
treanch etc as required. 75.00 meter 91.00
6,825.00 0.00
C11 MV Cable Laying upto 400 sqmm in
ground:
1.3
MVCBG
R400
Laying of 1 no. PVC insul and PVC
sheathed / XLPE cable of 1.1 KV grade
size exceeding 120sqmm but not
exceeding 400 sqmm, direct in ground
including excavation, sand cousioning,protective covering and refilling the
treanch etc as required. 60.00 meter 97.00
5,820.00 0.00
0.00 0.001.11
MVCBS
UR 25
and PVC sheathed/ XLPE aluminium
conductor cable of 1.1 KV grade of size
not exceeding 25sqmm on surface as
required. 190.00 meter 31.00
5,890.00 0.00
ELECTRICAL: Page 9
-
8/3/2019 Boq Electrical
10/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
1.12
MVCBS
UR 120
Laying and fixing of 1 no PVC insulated
and PVC sheathed/ XLPE aluminium
conductor cable of 1.1 KV grade of size
exceeding 25sqmm but not exceeding
120sqmm on surface as required. 435.00 meter 59.00
25,665.00 0.00
1.13
MVCBSUR 400
Laying and fixing of 1 no PVC insulated
and PVC sheathed/ XLPE aluminiumconductor cable of 1.1 KV grade of size
exceeding 120sqmm but not exceeding
400sqmm on surface as required. 40.00 meter 61.00
2,440.00 0.00
BASS COMPRESSION GRAND
C12 4.1
MVET S/M LV/MV cable end termination
Supplying and making end terminationwith brass compression grand and
aluminium lugs for following sizes of PVC
insulated and PVC sheathed/ XLPE
aluminium conductor cable of 1.1 KV
grade as required.
a 4.1.2 2 x 10 sqmm 14.00 each 76.00 1,064.00 0.00b 4.1.32 4 x 10 sqmm 16.00 each 104.00 1,664.00 0.00C12 4.1.33 4 x 16 sqmm 10.00 each 196.00 1,960.00 0.00
d 4.1.26 3.5 x 150 sqmm 6.00 each 278.00 1,668.00 0.00e 4.1.30 3.5 x 300 sqmm 2.00 each 508.00 1,016.00 0.00
4.1.21 3.5 x 35 sqmm 26.00 each 137.00 3,562.00 0.004.1.23 3.5 x 70 sqmm 2.00 each 168.00 336.00 0.004.1.22 3.5 x 50 sqmm 9.00 each 146.00 1,314.00 0.00
C14 1.5
WGSTL
PP2
Power Plug wiring in steel conduit (2 x
4 sqmm)
ELECTRICAL: Page 10
-
8/3/2019 Boq Electrical
11/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
Wiring for light/ power plug with 2x4sqmm
FRPVC insulated copper conductor single
core cable in surface/ recessed steel
conduit along with 1 no 4sqmm FRPVC
insulated copper conductor single core
cable for loop earthing as required. 2600.00 meter 136.00
353,600.00 0.00
(For Lab equipment power plug wiring)
C15 1.14
WGPVCSB Circuit/ submain wiring in PVC conduit
Wiring for circuit / submain wiring along
with earth wire with the following sizes of
FRPVC insulated copper conductor,
single core cable in surface/ recessed in
conduit as required.
a 1.14.1 2 x1.5 sqmm + 1x 1.5sqmm earth wire 1900.00 meter 71.00 134,900.00 0.00(Circuit wiring)
b 1.14.1 2 x1.5 sqmm + 1x 1.5sqmm earth wire 750.00 meter 71.00 53,250.00 0.00(6amp plug wiring)
c 1.14.3 2 x4 sqmm + 1x 4sqmm earth wire 1500.00 meter 97.00 145,500.00 0.00d 1.14.4 2 x6 sqmm + 1x 6sqmm earth wire 10.00 meter 127.00 1,270.00 0.00e 1.14.9 4 x 4 sqmm + 2x 4 sqmm earth wire 5.00 meter 148.00 740.00 0.00f 1.14.10 4 x 6 sqmm + 2x 6 sqmm earth wire 5.00 meter 207.00 1,035.00 0.00
C15 1.7
WGSTLSB Circuit/ submain wiring in Steel conduit
Wiring for circuit / submain wiring along
with bearth wire with the following sizes of
FRPVC insulated copper conductor,
single core cable in surface/ recessed in
conduit as required.
e 1.7.9 4 x 4 sqmm + 2x 4 sqmm earth wire 1250.00 meter 190.00 237,500.00 0.00(For Lab equipment power plug wiring)
ELECTRICAL: Page 11
-
8/3/2019 Boq Electrical
12/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
a 1.7.1 2 x1.5 sqmm + 1x 1.5sqmm earth wire 300.00 meter 109.00 32,700.00 0.00(Circuit wiring)
b 1.7.1 2 x1.5 sqmm + 1x 1.5sqmm earth wire 350.00 meter 109.00 38,150.00 0.00(6amp plug wiring)
1.7.10 4 x 6 sqmm + 2x 6 sqmm earth wire 550.00 meter 258.00 141,900.00 0.00
10 A LIGHT PLUG POINT WIRING ON
BOARD
C16 non-schedul
e
Wiring for 10 A light plug point on board
with 1100volt grade single core 3 Nos.1.5 sq. mm
(1 greencolour for earth) PVC insulated flexible
copperconductor cable (IS:694) complete with
providing
and fixing of 10 A 3 pin socket on switchboard and 10 A switch, earthing the 3rd
pin, etc. as requiredWith Modular Switch and approved
coloured plate 97.00 Point 698.000.00 67,706.00
POINT WIRING FOR LIGHT, FAN, ETC. :
C17 non-
schedul
e
Wiring for light/ ceiling fan / exhaust fan/
call bell point with 2x 1.5 sq.mm PVC
insulated copper conductor cable insurface/ recessed PVC conduit as
required.
a With 10A Modular Switch and approved
colour plate (primary point) 500.00 Point 895.000.00 447,500.00
b Secondary point without switch 300.00 Point 666.00 0.00 199,800.00
ELECTRICAL: Page 12
-
8/3/2019 Boq Electrical
13/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C17 non-
schedul
e
Wiring for light/ ceiling fan / exhaust fan/
call bell point with 2x 1.5 sq.mm PVC
insulated copper conductor cable in
surface/ recessed steel conduit as
required.
a With 10A Modular Switch and approved
colour plate (primary point) 100.00 Point 996.000.00 99,600.00
b Secondary point without switch 55.00 Point 767.00 0.00 42,185.00
2.62
MCBDP
SOC20
Supply and fixing 20A 240V SPN
Industrial type, socket outlet, with 2 pole
and earth metal enclosed plug top along
with 20A C series SPMCB, in sheet steel
enclosure, on surface or in recessed, with
chained metal cover for the socket outlet
and complete with connection, testing and
commissioning etc as required. 15.00 each 520.00
7,800.00 0.00
2.64
MCBTP
SOC30
Supply and fixing 30A, 415V , TPN
Industrial type, socket outlet, with 4 pole
and earth metal enclosed plug top along
with 30A C series TPMCB, in sheet steel
enclosure, on surface or in recessed, with
chained metal cover for the socket outlet
and complete with connection, testing and
commissioning etc as required. 18.00 each 1,294.00
23,292.00 0.00
non-
schedul
e
Supply and fixing power unit consisting
20A starter, 25A socket, 25A plug top with
4 module plate and box complete as
required. 14.00 each 1,150.00
0.00 16,100.00
SUPPLY & FIXING OF 16 A SOCKET
OUTLET& SWITCH :
ELECTRICAL: Page 13
-
8/3/2019 Boq Electrical
14/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C18 non-schedul
e
with 16A controlling switch, mounting box
and front cover on wall surface or
recessed in wall complete with chase
cutting, making good all damages to
originalfinish, interconnection, painting, etc. as
required tobe completed in all respect.
With Modular Switch/ socket andapproved coloured plate. 30.00 No. 941.00
0.00 28,230.00
SUPPLY & FIXING OF 10/6 A SOCKET
OUTLET & SWITCH :
C19 non-
schedul
e
Supply and fixing of 10/6 A socket outlet
withcontrolling switch, mounting box and front
cover on
wall surface or recessed in wall completewithchase cutting, making good all damages
to originalfinish, interconnection, painting, etc. as
required tobe completed in all respect.With Modular Switch/ socket and
approved coloured plate. 132.00 No. 711.000.00 93,852.00
ELECTRICAL: Page 14
-
8/3/2019 Boq Electrical
15/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C20 non-schedul
e
Supply and fixing of 16/13/10 A combined
socket outlet with the following i.e. (a) 1no
16A controlling switch with 16/10A socket,
(b) 1no 16A switch & 1no 13A universal
socket and ( c) 1no 10A switch & 10A
socket outlet, in single modular mounting
box and front cover on wall/ table surface
or recessed in wall complete with chase
cutting, making good all damages tooriginal.finish, interconnection, painting, etc. as
required to be completed in all respect.With Modular Switch/ socket and
approved coloured plate. 54.00 no 2,109.000.00 113,886.00
C21 non-
schedul
e
upp y ng ns a a on o sur ace
mounted Industrial type luminior with
stove enamelled reflector 2x36W T8 eqvWIPRO cat no WCF 26236 SWG,
suspended with required length of 2x
20mm dia painted MS conduit complete
with clamping arrangement as required, . 90.00 nos 3,583.00
0.00 322,470.00
C21 non-
schedul
e
Supplying & Installation of recessed type
integral low bay luminiar simillar to
WIPRO cat no WHH91070 with 1x 70W
MHL (double ended) fixed in metal falseceiling/ cladding complete as required. . 10.00 nos 9,565.00
0.00 95,650.00
C21 non-
schedul
e
mounted mirror optic luminior with
2x14wT5 eqv. PHILIPS cat no TCS
350/214 MI HF. 142.00 nos 3,088.00
0.00 438,496.00
ELECTRICAL: Page 15
-
8/3/2019 Boq Electrical
16/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C22 non-schedul
e
mounted mirror optic luminior with 2xTL5
28W PHILIPS cat no TCS 350/228 MI
HF. 82.00 nos 3,697.00
0.00 303,154.00
C25 non-
schedul
e
Supplying & Installation of surface
mounted mirror optic lumeniar with
paralite P5 louvers complete with 2x36w
CFL eqv. WIPRO cat no. WVP 44236. 18.00 nos 5,800.00
0.00 104,400.00
C26 non-schedul
e
Supplying & Installation of recessed
mounted mirror optic lumeniar with
paralite P5 louvers complete with 2x36w
CFL eqv. WIPRO cat no. WVP 24236. 36.00 nos 5,550.00
0.00 199,800.00
C27 non-
schedul
e
Supplying & Installation of wall mounted
decorative lumeniar with cylindrical
diffuser including 1x8W CFL eqv. cat
no.CITY-1 of Havells wall mounting range. 6.00 nos 935.00
0.00 5,610.00
C28 non-
schedul
e
Supplying & Installation of recessed
mounted ceiling decorative lumeniar with
diffuser including 1x55 W 2D lamp eqv.
cat no.CASPER of Havells. 2.00 nos 11,535.00
0.00 23,070.00
C29 non-
schedul
e
Supplying & Installation of recessed
mounted ceiling light low depth
downlighter with fresnel lens and 2 x 18W
CFL eqv. WIPRO WCP 28218. 65.00 nos 1,896.00
0.00 123,240.00
C30 non-
schedul
e
Supplying & Installation of slim energy
saving tube fitting with 1x 28W FTL(T5)
eqv. WIPRO cat no. WIF 21128 SWG 65.00 nos 1,858.00
0.00 120,770.00
C31 non-
schedul
e
Supplying & Installation of slim energysaving tube fitting with 2x 28W FTL(T5)
eqv. WIPRO cat no. WIF 21228 APF 14.00 nos 3,350.00
0.00 46,900.00
C32 non-
schedul
e
Supplying & Installation of bulk head fitting
with 1x 9W PL-S Lamp eqv. Philips
FXC/101. 2.00 nos 1,190.00
0.00 2,380.00
C33 non-
schedul
e
Supplying & Installation of decobattens
with 1x 14 w(T5) TLS eqv. Philips TWG
207 1x14w TLSHF 1.00 nos 955.00
0.00 955.00
ELECTRICAL: Page 16
-
8/3/2019 Boq Electrical
17/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C34 non-schedul
e
Supplying & Installation of decobattenswith 1x 28 w(T5) TLS eqv. Philips TWG
207 1xTLS28wHF 1.00 nos 1,200.00
0.00 1,200.00
non-
schedul
e
Supplying & Installation of decorative
surface mounted circular fitting with 2 x
18W CFL ( THORN cat no. ORBITLITE S
CORS 218 (E) or equivant. 70.00 nos 5,871.00
0.00 410,970.00
non-
schedul
e
Supplying & Installation of Out door
luminiar suitable for 70W (I) HPSV lamp
integral Translucent of KLITE ID 6831 with10' long Colombia pole complete with all
asseccories of Metal Coat ID No. 6005. 12.00 16,600.00
0.00 199,200.00
non-
schedul
e
Supplying & Installation Emergency light
with 8W PL lamp and one hour battery
backup Cat no. 617 31/617 87 G5NM of
Legrand 11.00 nos 7,820.00
0.00 86,020.00
C38 1.42
ITCFFD
R
ITC fluroscent fitting with down rods and
copper wiring: Installation, testing andcommissioning of prewired, flourescent
fittings of all types complete with all
accessories and tube etc. including supply
and fixing ball and socket arrangement,
2nos. down rods of 20mm dia x 1.6mm
thick steel conduit upto 30cm. length
painting and wiring the down rod and
connection with 1.5sqmmfFR PVC
insulated Cu conducter single core cable
and earthing etc. as required.
200.00 Each 126.00
25,200.00 0.00
ELECTRICAL: Page 17
-
8/3/2019 Boq Electrical
18/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C39 1.41ITCFFS
UR
ITC fluroscent fitting directly on surfacewith copper wiring: Installation, testing and
commissioning of prewired, flourescent
fittings of all types complete with all
accessories and tube etc. directly on
ceiling/wall including connections with 1.5
sq.mm FR PVC insulated, copper
conductor, single core cable and earthing
etc. as required25.00 Each 43.00
1,075.00 0.00
C40 1.43
EXTDR
P/F extra down rod with copper wiring:
Providing and fixing extra conduit down
rod of 20 mm dia. 2 X 10 cm length with 2
X 1.5 sq.mm FR PVC insulated , copper
conductor , single core cable including
painting etc. as required (Note: more than
5 cm length shall be rounded to the
nearest 10 cm. and 5 cm. or less shall be250.00 Each 17.00
4,250.00 0.00
C41 non-
schedul
e
Supply of 1200 AC ceiling fan of Delux
model quality, complete as required. 42.00 no 2,214.00
0.00 92,988.00
non-
schedul
e
Supply of 1400 AC ceiling fan of Delux
model quality, complete as required. 248.00 no 2,400.00
0.00 595,200.00
C42 non-
schedul
e
Supply of 300mm dia Metal body Exhaust
fan with louvers. 32.00 no 3,036.00
0.00 97,152.00
non-
schedul
e
Supply of 450mm dia Metal body heavy
duty Exhaust fan with louvers. 12.00 no 4,680.00
0.00 56,160.00
C43 non-
schedul
e
Supply and installing 400mm dia with
rotating head wall bracket fan suitable for
240 V AC supply. 13.00 no 2,150.00
0.00 27,950.00
ELECTRICAL: Page 18
-
8/3/2019 Boq Electrical
19/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C44 non-schedul
e
Supply and fixing 2 module ceiling fanregulator in the existing switch plate as
required. 290.00 no 500.00
0.00 145,000.00
C45 1.44
ITCCF
I T C of ceiling fan including wiring the
down rods of standard length (upto 30cm)
with 1.5 sqmm FRPVC insulated copper
conductor single core cable etc as
required, upto 450mm sweep in the
existing opening, including making the
hole to suit the size of the above fan,
making good the damage, connections,
testing, commissioning etc. as required.290.00 Each 45.00
13,050.00 0.00
C46 1.52
ITCEF4
50
Installation of exhaust fan upto 450mm
sweep in the existing opening, including
making the hole to suit the size of the
above fan, making good the damage,
connections, testing, commissioning etc.
as required. 44.00 Each 223.00
9,812.00 0.00
C47 1.54
LOUSH
EF
Fixing louvres /shutters for exhaust
fan:Extra for fixing the louvres /shutters
complete with frames for exhaust fans of
all sizes 44.00 Each 65.00
2,860.00 0.00
C48 4.2
LCFGI
Providing and fixing of lightning conductor
finial, made of 25mm dia, 300mm long GI
tube, having single prong at top, with
85mm dia 6mm thick GI base plate
including holes etc. complete as required. 16.00 each 243.00
3,888.00 0.00
C49 4.7
LCGITS
URH
Providing and fixing GI tape 20mm x3mm
thick on parapet or surface of wall for
lightning conductors as required ( for
horizontal run) 500.00 meter 31.00
15,500.00 0.00
ELECTRICAL: Page 19
-
8/3/2019 Boq Electrical
20/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
C50 4.8LCGITS
URV
Providing and fixing GI tape 20mm x3mm
thick on parapet or surface of wall for
lightning conductors as required ( for
verticall run) 200.00 meter 43.00
8,600.00 0.00
C51 4.12
LCTJGI
Providing and fixing testing joints, made of
20mm x 3mm thick GI strip, 125mm long
with 4 Nos of GI bolts nuts check nuts and
spring washer complete as required. 8.00 each 37.00
296.00 0.00
C52 3.5EARGIP
L
GI Earth Plate Electrode : Earthing with GIplate 600mm x 600mm x 6mm thick
including accessories and providing
masonry enclosure with cover plate
having locking arrangement and watering
pipe etc. (but without charcoal or coke and
salt complete) as required. 14.00 set 1,585.00
22,190.00 0.00
C53 3.7
EARCH
ARPL
Salt /charcoal for plate earth electrode:
Extra for using charcoal and salt for G.I.
copper plate earth electrode as required14.00 set 603.00
8,442.00 0.00
3.10
EAR6G
GIWR
Supply & Laying of 6 SWG GI wire at
0.5meter below ground level / along cable
thru pipe for conductor earth electrode
including soldering etc s required. 400.00 meter 16.00
6,400.00 0.00
ELECTRICAL: Page 20
-
8/3/2019 Boq Electrical
21/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
Providing, Installation, Testing andCommissioning of Otis or equivalent make
Electric Traction Passenger Elevator of 10
person (680 Kgs) capacity Elevators,
traveling from ground floor to third floor (4
stops, 4 opening,) stopped at all floor and
opening on the same side, 1 m/s speed,
AC varable voltage variable frequency (
with close loop) controlled, simplex full
collective, automatic with ACVVVF door
operator & multi-ray door detector system,
stainless steel hair finished car and car
door, etc complete ( Otis model code No.
OPTIMUS-7C10A-7-18M) as per
specification and instruction of Engineer in
charge. The work also include all building/
structural works for supporting
arrangement system, necessaryscaffolding required for erection of the
complete system, necessary wiring and
installation of lighting for lift well and lift pit,
providing ladder in the lift pit etc. as 1.00 each 2,070,000.00
0.00 2,070,000.00
C55 Non-
schedule
Supply, installation, testing &
commissioning of Hi wall split unit with
outdoor unit, Indoor Unit, refrigeration pipe
of required length (with insulation as
required), PVC drainout pipes of requiredlength, electrical starter unit with
necessary wiring etc. complete as per
instruction of engineer-in-charge. The rate
shall be inclussive of the cost of
supporting system of the outdoor unit.
a 2.0 TR 12.00 each 45,000.00 0.00 540,000.00
ELECTRICAL: Page 21
-
8/3/2019 Boq Electrical
22/22
Sl.
No
DSR
NO
Description of Itemstotal
Qty Unit DSR NDSR DSR NDSR
b 1.5 TR 2.00 each 42,000.00 0.00 84,000.00
Rs. 1,495,830.00Cost after index Rs. 2,587,785.90
Rs. 9,165,218.00
SUB-TOTAL (DSR)
SUB-TOTAL (NON-SCH)
ELECTRICAL: Page 22
top related