boot mode 1

Post on 30-Dec-2015

24 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

DESCRIPTION

6. ENABLE COMM FAIL RELAY CONTROL. 1. RUN MODE 1. 7. RELAY OFF / ON COMM FAIL. 2. RUN MODE 2. 1. RUN MODE 1. 1. BOOT MODE 1. 2. RUN MODE 2. 2. BOOT MODE 2. 3. BIOS COMMUNICATION. 4. DEFAULT CONTROLLER. 1. RUN MODE 1. 2. RUN MODE 2. ENABLE COMM FAIL RELAY CONTROL. - PowerPoint PPT Presentation

TRANSCRIPT

1

2

3

4

5 6

7

8

BOOT MODE 1

BOOT MODE 2

BIOS COMMUNICATION

DEFAULT CONTROLLER

INVERT RELAY OPERATION

ENABLE COMM FAIL RELAY CONTROL

RELAY OFF / ON COMM FAIL

DRM MODULE ENABLED

1

2

3

4

RUN MODE 1

RUN MODE 2

ADDRESS 1

5 INVERT RELAY OPERATION

RELAYS NOT INVERTED

5 INVERT RELAY OPERATION

RELAYS INVERTED

8 DRM MODULE ENABLED

8 DRM MODULE ENABLED

DRM MODULE DISABLED

DRM MODULE ENABLED

6

7

ENABLE COMM FAIL RELAY CONTROL

RELAY OFF / ON COMM FAIL

1

2

RUN MODE 1

RUN MODE 2

1

2

RUN MODE 1

RUN MODE 2

1

2

RUN MODE 1

RUN MODE 2

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 1FLOOR 1 TO 16

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 2FLOOR 17 TO 32

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 3FLOOR 33 TO 48

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 4FLOOR 49 TO 64

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 5FLOOR 1 TO 16

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 6FLOOR 17 TO 32

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 7FLOOR 33 TO 48

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 8FLOOR 49 TO 64

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 9

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 10

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 11

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 12

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 13

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 14

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 15

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 16

AC

AC

B+

B- S

T T

P T

P

1K5 OHM

LED

16VAC 40VA MAX

TRANSFORMER50/60Hz 40VA MAX

MAINSINPUT

+12V AUX

AC

AC

B+

B- S

T T

P T

P

4Ah (MIN)GEL CELLBACKUP BATTERY

N+

N-

N

A

NB

TP

TP

F+

F-

FIRE CONTROLSYSTEM

12 - 32VDC6 - 21mA

TO NEXTELEVATORCONTROLLER

AC

AC

B+

B- S

T T

P T

P

N+

N-

N

A

NB

N+

N-

N

A

NB

N+

N-

N

A

NB

CONTROLLER

EOL ON

0V

B-

A+

12

V

S+

S-

S

A

SB

TO FIRST SLAVE FLOORCONTROL MODULE.PRT-PX16 IN FLOORCONTROL MODE.

TAMPER SWITCH

N+

N- N

A N

B T

P T

P

N+

N

-

NA

N

B

NETWORK COMMUNICATIONSINPUT FROM SYSTEMCONTROLLER OR PREVIOUSPROTÉGÉ SYSTEM MODULE

NO

CO

M N

CR

EL

AY

1

FLOOR SELECT BUTTONIN ELEVATOR CAR

FLOOR INPUT TERMINALSIN ELEVATOR CONTROL SYSTEM

NORMAL CONNECTIONREMOVED

LOOP TERMINAL ADDED BYELEVATOR COMPANYLOCATED IN ELEVATOR CONTROLSYSTEM

NO

CO

M N

CR

EL

AY

1

FLOOR SELECT BUTTONIN ELEVATOR CAR

FLOOR INPUT TERMINALSIN ELEVATOR CONTROL SYSTEM

NORMAL CONNECTIONREMOVED

LOOP TERMINAL ADDED BYELEVATOR COMPANYLOCATED IN ELEVATOR CONTROLSYSTEM

NO

CO

M N

CR

EL

AY

1FLOOR SELECT BUTTON

IN ELEVATOR CAR FLOOR INPUT TERMINALSIN ELEVATOR CONTROL SYSTEM

NORMAL CONNECTIONREMOVED

LOOP TERMINAL ADDED BYELEVATOR COMPANYLOCATED IN ELEVATOR CONTROLSYSTEM

+ IN

1 - +

IN2

-

INPUTS ON THE DRMDAUGHTER BOARD

RELAY CONTACTSON THE MAIN ELEVATOR CONTROLBOARDSEE TEXT

BUTTON VOLTAGECOMMON IN ELEVATORCONTROL SYSTEM

NO

CO

M N

CR

EL

AY

1

FLOOR SELECT BUTTONIN ELEVATOR CAR FLOOR INPUT

TERMINALSIN ELEVATOR CONTROL SYSTEM

NORMAL CONNECTIONREMOVED

LOOP TERMINAL ADDED BYELEVATOR COMPANYLOCATED IN ELEVATOR CONTROLSYSTEM

+ IN

1 - +

IN2

-

INPUTS ON THE DRMDAUGHTER BOARD

RELAY CONTACTSON THE MAIN ELEVATOR CONTROLBOARD

SEE TEXT

BUTTON VOLTAGECOMMON IN ELEVATORCONTROL SYSTEM

+ IN

1 - +

IN2

-

INPUTS ON THE DRMDAUGHTER BOARD

AC

AC

B+

B- +

- ST

POWER CONNECTOR ONMAIN ELEVATOR CONTROLBOARD

EOL

EOL ON EOL OFF

350mA

700mA

350mA

700mA

FIRE

OVERRIDE FIRE

OVERRIDE

EOL

1

2

3

4

5

6

7

8

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 16

ADDRESS 32

ADDRESS 64

SPECIAL FUNCTION

1

2

3

4

5

6

7

8

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 16

ADDRESS 32

ADDRESS 64

SPECIAL FUNCTION

1

2

3

4

5

6

7

8

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 16

ADDRESS 32

ADDRESS 64

SPECIAL FUNCTION

1

2

3

4

5

6

7

8

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

ADDRESS 16

ADDRESS 32

ADDRESS 64

SPECIAL FUNCTION

N+

N-

N

A

NB

N+

N-

N

A

NB

N+

N-

N

A

NB

PC OR HOST CONTROLSYSTEM CONNECTED TO

A ACC-485 SERIAL INTERFACE

EOL OFF EOL OFF EOL ON

+1

2

0V

A+

B

-

AC

AC

B+

B- +

- ST

7.5AhGEL CELLBACKUP BATTERY

N+

N-

N

A

NB

TP

TP

F+

F-

FIRE CONTROLSYSTEM

12 - 32VDC6 - 21mA

TO NEXTIRC RELAYCONTROLLER

N+

N-

N

A

NB

FROM PREVIOUS CONTROLLER

TO NEXT IRC CONTROLLER

TP

TP

F+

F-

TAMPER SWITCH

AC

AC

B+

B- S

T T

P T

P

COLD WATER PIPE GROUNDINGEARTH PEG GROUNDING ROD

TO OTHER EARTHCONNECTIONS

ALREADY ATTACHEDTO THE EARTH PEG OR

WATER PIPE

MIN AWG#14SINGLE SOLIDCONDUCTOR

COPPER WIRE

N+

N-

N

A

NB

N+

N-

N

A

NB

MODULE OR CONTROLLERSUPPLYING POWER TONETWORKED DEVICES

AU

X+

AU

X-

N+

N-

N

A

NB

NEXT MODULESON NETWORK

N+

N-

N

A

NB

N+

N-

N

A

NB

READER EXPANDER SUPPLYING NETWORK

POWER

AU

X+

AU

X-

S+

S-

S

A

SB

NEXT FLOORCONTROL MODULE

SLAVE DEVICES CONNECTED TO THE READER EXPANDER SLAVE

COMMUNICATION INTERFACE USETHE N+, N-, NA AND NB TERMIANLS.

+ - D

0 D1 L

1 L2

BZ

PRX-SAMREADER CONNECTION

RED

BLACK

GREEN

WHITE

ORANGE

BROWN

BLUE

SHIELD

CONNECT THE READERSHIELD TO A SUITABLE

EARTH POINT.DO NOT CONNECT THE

SHIELD TO A GROUND ORNEGATIVE CONNECTION.

+12V

0V

DATA 0

DATA 1

GREEN LED

RED LED

BEEPER

PRX-NANO NANO PROXPROXIMITY READER

YELLOW

YELLOW OUTPUT CARD PRESENT SIGNAL

FACTORY OPTION

-

+

POWER SUPPLY 12VDC

+ - D

0 D

1 L1 L

2 B

Z R

2 R2

R2

R2

R2 R

2 R

2

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

+12V

0V

DATA 0

DATA 1

GREEN LED

RED LED

BEEPER

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

DATA 1

ENTRY UNIT

EXIT READER

READER #1INPUT CONNECTION

READER #2INPUT CONNECTION

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

+12V

0V

DATA 0

DATA 1

GREEN LED

RED LED

BEEPER +

- D0

D1 L

1 L2

BZ

R1 R

1 R

1 R

1 R

1 R1

R1

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

+12V

0V

DATA 0

DATA 1

GREEN LED

RED LED

BEEPER

NC

CO

M N

O P

1 I3

I2 I1

DOOR CONTACTNORMALLY CLOSED

REQUEST TO EXITNORMALLY OPEN

+

-

ELECTRICLOCKING DEVICE

1N4007 DIODE(SUPPLIED)

-

+

BUZZERINPUT

ALARMOUTPUT

POWER SUPPLY12VDC

PRX-SAMINTERFACE

CONNECTIONS

NC

CO

M N

O P

1 I3

I2 I1

DOOR CONTACTNORMALLY CLOSED

REQUEST TO EXITNORMALLY OPEN

+

-

ELECTRICLOCKING DEVICE

1N4007 DIODE(SUPPLIED)

-

+

DB9RS232

POWER SUPPLY12VDC

PRX-SAMINTERFACE

CONNECTIONS

PIN 2RXD

PIN 3TXD

PIN 5GND

NC

CO

M N

O P

1 I3

I2 I1

DOOR CONTACTNORMALLY CLOSED

REQUEST TO EXITNORMALLY OPEN

+

-

ELECTRICLOCKING DEVICE

1N4007 DIODE(SUPPLIED)

-

+

RS485

POWER SUPPLY12VDC

PRX-SAMINTERFACE

CONNECTIONS

NA

NB

COM

NC

CO

M N

O P

1 I3

I2 I1

DOOR CONTACTNORMALLY CLOSED

REQUEST TO EXITNORMALLY OPEN

+

-

ELECTRICLOCKING DEVICE

1N4007 DIODE(SUPPLIED)

-

+

BUZZERINPUT

ALARMOUTPUT

POWER SUPPLY12VDC

PRX-SAMINTERFACE

CONNECTIONS

NC

CONNECTION SHOWNFOR LOCK RELAY 1

+

-

ELECTRICLOCKING DEVICE

1N4007 DIODE(SUPPLIED)

- +

POWER SUPPLY FOR LOCKINGDEVICES MAX 30VDC

1K 1K

N.C. ZONE CONTACT

N.C. TAMPER CONTACT

N.C.

ZONE INPUT

COMMON

AU

X A

UX

Z1 C

OM

Z2

Z3 C

OM

Z4

+ - D

OO

R1

RE

X1

SE

N1

RE

N1

RESISTORS SHOULD BELOCATED AT THE DEVICEATTACHED TO THE ZONE

ZONE INPUT SHOWNFOR ZONE 1

N.C. ZONE CONTACT

N.C.

ZONE INPUT

COMMON

AU

X A

UX

Z1 C

OM

Z2

Z3 C

OM

Z4

+ - D

OO

R1

RE

X1

SE

N1

RE

N1

ZONE INPUT SHOWNFOR ZONE 1

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

CONNECTION SHOWN FORPGM RDxxx:03

1K5 OHM

LED

+12V AUX1

2

3

4

5

6

7

8

ADDRESS 4

ADDRESS 8

ADDRESS 1

ADDRESS 2

ADDRESS 64

ADDRESS 16

ADDRESS 32

DEFAULT / RUN

1

2

3

4

ADDRESS 1

ADDRESS 2

ADDRESS 4

ADDRESS 8

READER EXPANDERADDRESS 079

5

6

7 ADDRESS 64

ADDRESS 16

ADDRESS 32

CROSSOVERDIRECT ETHERNET

CONNECTION

8 PORT ETHERNET HUBREADER EXPANDER

RJ45 ETHERNETCONNECTOR

READER EXPANDERRJ45 ETHERNET

CONNECTOR

MULTIPLE ETHERNETCONNECTIONS USING

A ETHERNET HUB

ET

HE

RN

ET

ET

HE

RN

ET

N+

N-

N

A

NB

N+

N-

N

A

NB

SYSTEM CONTROLLER SUPPLYING NETWORK

POWER

AU

X+

AU

X-

N+

N-

N

A

NB

NEXT MODULEON NETWORK

STANDARD ZONE EXPANDERS CONNECTED TO

THE SYSTEM CONTROLLERCOMMUNICATION INTERFACE USE

THE N+, N-, NA AND NB TERMIANLS.

N+

N

-

NA

N

B

MODULE NETWORKCOMMUNICATIONS

CROSSOVERDIRECT ETHERNET

CONNECTION

8 PORT ETHERNET HUB

SYSTEM CONTROLLERRJ45 ETHERNET

CONNECTOR

MULTIPLE ETHERNETCONNECTIONS USING

A ETHERNET HUB

ET

HE

RN

ET

ET

HE

RN

ET

SYSTEM CONTROLLER

RJ45 ETHERNETCONNECTOR

ET

HE

RN

ET

SYSTEM CONTROLLER

ONE

SYSTEM CONTROLLER

TWO

T2i

R2i

T

1i

R1

i T

1o R

1o

TELEPHONELINE CONNECTION

TERMINAL

COLD WATEREARTH PIPE

PRIMARY TELCOLINE OUT

PRIMARY TELCOLINE RING AND TIPINPUT (T1i and R1i)

SECONDARY TELCOLINE RING AND TIPINPUT (T2i and R2i)

N.C. ZONECONTACT

Z1

Z2

Z3 C

OM

Z5 Z

6 Z7

DR

1 R

EX

1 S

EN

1 D

R2 R

EX

2 SE

N2

N.C. TAMPER

1K1K

N.C. ZONECONTACT

Z1

Z2

Z3 C

OM

Z5 Z

6 Z7

DR

1 R

EX

1 S

EN

1 D

R2 R

EX

2 SE

N2

B1

+ B

1- B

2+

B2

- P3

P4

CONNECTION SHOWNFOR BELL/SIREN 1

CP001:01

+

-

12VDC SIRENWARNING DEVICE

B1

+ B

1- B

2+

B2

- P3

P4

CONNECTION SHOWNFOR CP001:03

1K5 OHM

LED

+12V AUX

350mA

700mA

L

H

FIRE

OVERRIDE FIRE

OVERRIDE

L

H

L

H

350mA

700mA

N+

N- N

A N

B

+1

2 0

V T

X R

X R

TS

N+

N- N

A N

B

AU

X

+ -

ACC-485 RS485CONVERTOR

SYSTEM CONTROLLERMODULE NETWORK CONNECTION

SYSTEM CONTROLLERAUXILLARY TERMINALS

USE SERIAL CABLE SUPPLIED WITHACC-485 TO CONNECT TO THE PC SERIAL PORT

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

CONNECTION SHOWN FORPROTÉGÉ SYSTEM

READER 1 PORTSINGLE LED READER CONTROL

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

CONNECT THE READERSHIELD TO A SUITABLE

EARTH POINT.DO NOT CONNECT THE

SHIELD TO A GROUND ORAUX- CONNECTION.

+12V

0V

PRX-NPROXNANO PROX

PROXIMITY READER

YELLOW

YELLOW OUTPUT CARD PRESENT SIGNAL

FACTORY OPTIONORANGE IS NOTUSED IN SINGLE LED OPERATION

N.O. BUTTON

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

CONNECTION SHOWN FORPROTÉGÉ SYSTEM

READER 1 PORTSINGLE LED READER CONTROL

WITH BUTTON INPUT CONNECTION

RED

BLACK

GREEN

WHITE

BROWN

ORANGE

BLUE

SHIELD

CONNECT THE READERSHIELD TO A SUITABLE

EARTH POINT.DO NOT CONNECT THE

SHIELD TO A GROUND ORAUX- CONNECTION.

+12V

0V

PRX-NPROXNANO PROX

PROXIMITY READER

YELLOW

YELLOW OUTPUT CARD PRESENT SIGNAL

FACTORY OPTIONORANGE IS USED

FOR BUTTON INPUT CONNECTION

N.O. BUTTON

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

CONNECTION SHOWN FORPROTÉGÉ SYSTEM

READER 1 PORT

YELLOW

GREEN

RED

BROWN

ORANGE

+5V

0V

CLOCK

DATA

OMRON READERMAGNETIC STRIPE READER

TRACK 2

OUT COM IN

INLINE +5V REGULATOR50mA MAX OUTPUTPART CODE REG-5V

+12V

0V

CLOCK

DATA

CARD PRESENT

REG-5V WIRING

RED = INPUT (+9 TO +12V)COM = 0V

WHITE = OUTPUT (+5V)

IMPORTANT NOTE

THE STANDARD OMRON/MAGTEK CARD READERS CAN HAVE AN INTERNAL MODIFICATION TO ALLOW THEM TO OPERATE FROM +12V WITHOUT THE

INLINE REGULATOR AS SHOWN IN THIS DIAGRAM. PLEASE CONTACT ICT FOR

FURTHER INFORMAITON.

FOR THE CONNECTION OF OTHER MAGNETIC CARD

DEVICES REFER TO MANUFACTURERS

INSTALLATION MANUAL

+ - D

0 D

1 L1 L

2 B

Z R

1 R1

R1

R1

R1 R

1 R

1

CONNECTION SHOWN FORPROTÉGÉ SYSTEM

READER 1 PORT

RED

BLACK

GREEN

WHITE

ORANGE

BROWN

BLUE

SHIELD

CONNECT THE READERSHIELD TO A SUITABLE

EARTH POINT.DO NOT CONNECT THE

SHIELD TO A GROUND ORAUX- CONNECTION.

+12V

0V

DATA 0

DATA 1

GREEN LED

RED LED

BEEPER

PRX-NANO NANO PROXPROXIMITY READER

OR WIEGAND READER

YELLOW

YELLOW OUTPUT CARD PRESENT SIGNAL

FACTORY OPTIONFOR OTHER PROXIMITY READER

CONNECTIONS REFER TO THE MANUFACTURERS

INSTALLATION MANUAL

4 CORE CONDUCTORBETWEEN READERAND CONTROLLER

top related