axa uno back to wall pan - d12qbzr1dyleru.cloudfront.net · align and push pan back to wall,...
Post on 04-Aug-2020
2 Views
Preview:
TRANSCRIPT
AXAUNO BACK TO WALL PAN
SPECIFICATIONSRecommended use Domestic, Hotel and Commercial
Colour availability White
Rim configuration Open rim
Set out S Trap: 95mm
P Trap: 180mm fixed
Pan fixing Fixed to floor
Seat Matching top fix Soft Close Quick Release seat supplied with suite
Material Vitreous china
Weight Pan: 25kg
CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved bathroom cleaners.
This bathroom product should not be cleaned with abrasive materials.
Damage caused by any improper treatment is not covered by the product warranty - Refer to Warranty Conditions.
To see the complete Axa range go to www.reece.com.au/bathrooms
520
360390
20095
420180
350
180
99
page 1 of 2
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.
Tech Page Version 5
TM
WMKA21243 AS 1172.1
Dimensions are nominal measurements only
The more stars the more water efficient
WATER RATINGwww.waterrating.gov.au
In accordance with AS/NZS 6400
Licence No. 0437AXA ONE SrL
4.5 L per full flush / 3 L per half flush
3.3 litres average flush
AXAUNO BACK TO WALL PAN
INSTALLATION INSTRUCTIONS
Note
All measurements for roughing in should be taken from finished wall/floor. Dimensions shown are nominal measurements only.
1. Rough in positions of water inlet and waste outlet.
2. Mark out and drill floor fixing brackets into position (140mm apart, 200mm from finished wall) and mark out and prepare plate, rod and plastic bend if installing the waste into the floor via a pan collar.
3. Fix the pan bend connector back to the wall using the rod and bracket.
4. Align and push pan back to wall, connecting pan spigot into waste bend and pan inlet into flush pipe and keeseal.
5. Check pan is level.
6. Fix pan by using the fixing screws through the fixing holes into the floor fixing brackets.
7. Flush pan to check connections for leaks.
8. Apply flexible sealant around base and rear of pan to seal to wall and floor.
he
m
e
250mm
200mm14
0mm
175mm
m
4-6 P-Trap installation
350
inlet
outlet
175
Levelling
S-Trap setup P-Trap setup
Fixing
SILICONE
Pan collar
140
page 2 of 2
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference