Application Product Construction Technical Data

ü�Conductor : Finely Stranded Annealed

Electro Tinned Copper, Class 5.

ü�Insulation : Cross linked Silicone Rubber

ü�Screen : Tinned Copper Braid

ü�Outersheath : Cross linked Silicone Rubber

Black colour or as per Customer order.

ü�Cables are used in Driver desks, Control panels, wiring harness in inside/outside moving vehicles.

0 0ü�Temperature Range : -40 C to +120 C.

ü�Rated Voltage : 3.6/6kV

ü�Specification : BS EN 50382 - 2

In addition to BS EN 50382 spec, cables

also meet fire performance tests as per

EN 50306-2

DIN 5510-2

BS 6853

NF F 16-101

2D View

Featuresü�Excellent resistance to high and low temperatureü�Outstanding Flame retardant ü�Halogen freeü�Thin walled with excellent flexibilityü�Resistance to Oil, fuel,ozone and weathering.ü�Easy to stripü�Low smoke densityü�Soldering iron resistantü�Electron Beam Cross Linked.ü�Resistance to corona effect.

Wires & Cables

Cross Section2 (mm )Part Number

Outer diameter (mm) (Nom)

Note : XX* & YY*: Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11

Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21

0Siechem BS EN 50382-2 Single Core, Screened, 1.8/3kV, EBXL 120 C High Temperature Rolling Stock Cable

Catalogue No.

570

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

32

0Siechem EN 50382-2 Single Core, Screened 1.8/3kV AC, EBXL 120 C High Temp Rolling Stock Cable

Cable Weight (Kg/Km) approx.

*57013XXYY

57016XXYY

57019XXYY

57023XXYY

57027XXYY

57028XXYY

57030XXYY

57032XXYY

57034XXYY

57037XXYY

57038XXYY

57041XXYY

57042XXYY

57044XXYY

57046XXYY

57048XXYY

57049XXYY

30 X 0.25

50 X 0.25

56 X 0.30

84 X 0.30

80 X 0.40

126 X 0.40

196 X 0.40

276 X 0.40

396 X 0.40

360 X 0.50

475 X 0.50

608 X 0.50

756 X 0.50

925 X 0.50

1221 X0.50

1525 X 0.50

2013 X 0.50

Conductor Diameter (mm)

1.5

1.95

2.5

3.0

3.9

5.0

6.4

7.7

9.2

11.0

12.5

14.2

15.8

17.5

20.1

22.5

25.8

Insulation Thickness(Nom.) ( mm)

Sheath Thickness(Nom.) ( mm)

1.3

1.3

1.3

1.3

1.3

1.5

1.5

1.8

1.8

1.8

1.8

2.2

2.2

2.4

2.4

2.4

2.6

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.5

1.5

1.6

1.6

1.7

1.8

1.9

2.0

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

13.7

8.21

5.09

3.39

1.95

1.24

0.795

0.565

0.393

0.277

0.210

0.164

0.132

0.108

0.0817

0.0654

0.0495

7.4

7.8

8.4

8.9

10.2

11.4

13.4

14.8

16.3

18.3

20.6

22.6

24.2

26.6

29.4

32.1

36.1

111

131

168

201

277

373

528

668

864

1151

1453

1783

2144

2554

3252

3935

5067

Conductor Construction No.of Strands x Strand dia Nos x mm