    ALM 30

    ALM 32LOAD MANAGER P O R T A B L E

    An irresistible Analyser that empowers Energy Managers

  • 7/30/2019 ALM 30&32 Brochure

    2/4

    Ex p e rie n c e th e p o w er o f n e w g e ne r a t io n m e a su r e m en t t e c h no lo g y

    v You cannot miss any load - Continuous cycle by cycle measurement of all 3 currents and 3 voltages @ 256 samples/cycle

    guarantees accuracy even on non-linear loads

    v You cannot miss any load condition - PF measurement range from 0 lag to 1.0 to 0 lead

    v You cannot miss the true picture of your electrical system - Get deeper insights with multi-colour 3-phase waveforms,trends, bar-graphs, vector diagrams, multi-parameter displays & energy counters

    Discover the new-found freedom of convenient usage

    v Take direct measurements on busbars or multi-rung cables using flexible probes; Easily access hitherto unreachable

    small cables; Measure HT through P T & CT - Wide choice of clamp-on CTs to measure currents from 5mA upto 6500A

    v Record selected parameters at selected intervals using the large 2MB memory (4MB in A LM 32) for in-depth analysis

    v Conduct long hours of uninterrupted field studies with upto 8 hours battery back-up

    vCapture what you see as pictures for download, review & presentation - take upto 8 pictures (12 in A LM 32)

    Expand your energy saving horizon with limitless applications

    v Track power variations & energy consumption over production cycles to accurately arrive at product/process costing

    v Initiate appropriate actions to reduce losses by conducting in-depth harmonic studies on drives, inverters, furnaces, UPS,

    ringframes & other non-linear loads

    v A ccurately evaluate the energy saving potential of energy-saving devices & processes for judicious investment decisions

    v Evaulate capacitor banks by direct kVA r & P F measurements for the first time to judge their performance, quality & life

    Improve the quality of your maintenancev Capture abnormal variations to identify potential problems (minimum cycle detection) for a wide range of parameters

    v Perform specific energy studies to identify machines with more losses for carrying out preventive maintenance

    v Monitor a variety of power quality parameters affecting your machinery to cut down-times

    v Use the DataViewer software to correlate variations between different parameters and arrive at a comprehensive solution

    Just look at the range of comprehensive measurements

    v T ru e R M S A C Vo l t ag e

    v T ru e R M S A C C u r re n t u p to 6 5 0 0 A mp s

    v Frequency

    v D C Vo l ta g e

    v D C C u r re n t w it h o pt i o na l C Ts

    v Peak Voltage and current

    v kW, kVA, kVAr per phase and total

    v kWh, kVAh, kVArhv P F

    thv Harmonics for voltage, current upto the 50 order

    v N e u tr a l c u r re n t

    v Total harmonic distortion

    v Distortion PF, Displacement PF and tangent

    v Voltage and current unbalance

    v Crest factors for current and voltage

    v Flicker measurements

    v K-Factor for current (transformer application)

    Additional information in ALM 32

    v Details of Zero, +ve, -ve sequence harmonics

    v Transients (1 cycle pre-event and 3 cycles post-event

    recording)

    v Information on whether harmonics are generated or

    received

    F e e l t h e e xc i t em e nt o f E n er g y M a n ag e me n t l i ke n e v er be f or e

    Basic Power Quality

    P o we r & E n er g y

  • 7/30/2019 ALM 30&32 Brochure

    3/4

    R e a l T i me D a t aas values,as waveformsas vector diagrams

    Harmonicsas bargraphsu p to 50 t h o n b o th V & I( a l s o o n VA i n A LM 3 2 )

    P o w er s & E n e r gi e sW, VA, VAR, PF+/-Wh, VAh, +/-VARhStart/stop record energy feature

    Recording

    2 M B m e mo r y wi t hselectable parameter r e c o rd i n g ( 4 M B f o r A L M 3 2 )

    Set-upE a s y p r o g ra m m i n g f o r 2/3/4-wireRecording

    AlarmsP C d o wn l oa d

    PicturesStore upto 8 pictures of a n y s c r e e n o f d a ta , w a v e fo r m . . ..(12 for ALM 32)

    Current probe optionsChoose 5, 100, 1000A optionsC h o os e 0 0 A A m p f l ex C T o p t i on65

    HelpHelp button explains functionsof the screen under view

    Power Quality Data

    CF, THD, K-factor, Flicker,Tangent, DPF, unbalances,N e u tr a l c u r r en t

    Alarms4096 alarm recordsdetection of 1/2 cyclevariations for easy diagnosis

    Transients (ALM 32)Upto 50 records1 cycle pre-event &3 cycle post-event for analysis

    Trendson the meter screenf o r a ll r e c o r de d d at afor on-field analysis

    se , M ea su re & A na ly se - A ll t hr ou gh g ra ph ic al s cr ee ns

  • 7/30/2019 ALM 30&32 Brochure

    4/4

    U se D a ta Vi ew er f or a dv an ce d a na ly si s & r ep or ti ng

    Choose from the wide range of accessories

    MN93AAmpflex

    Range: 10 to 6500A#1: 450mmL,140mm dia#2: 800mmL, 250mm dia

    Range: 3 to 1000AID: 50mm

    D u al R a ng e :5 mA t o 5 A & 1 00 mA t o 1 00 AID: 20mm

    MN93

    Range: 2 to 200AID: 20mm

    C193

    s e

    r

    n

    be

    r

    con

    vatio

    gi n

    sh

    e

    e

    S of tw ar e t o C on n ec t, A n al ys e & R ep or t

    J u s t co n n e c t & c o m m un i c a t ev A utom atically detect the m odel type and establish an appropriate data connection

    v S e tu p & c o nf i g ur e a l l u s er d e fi n ab l e v a lu e s

    v D o wn l o ad r e co r de d d a ta a s p i ct u re s, t ab l es o r li s t s d e pe n di n g on t he t y pe o f da t a

    v View real-tim e data from the m eter on the screen

    Analyse with easev U s e t h e I n t e l li g e n t p r e - de f i n e d t e m p la t e s f o r i m m ed i a t e a n a l y si s

    v View the graphical trend, m in, m ax & avg values of every recorded param eter in separate pages with just a single click

    v E n j o y t h e p o w e r f ul g r a ph i n g ca p a bi l i t i e s - Z o o m -i n , zo o m - o ut & v a l u e c u r s o rs w i t h au t o t i m e - sc a l i n g f o r i n- d e p th a n al y s i s

    v S p e c i f y s e t p o in t s f o r a n y pa r a me t e r & g e t a n i ns t a n t l is t o f v a ri a t i o ns f r o m t he s e t p o in t w i t h th e r e s p ec t i v e d u r at i o n s

    Report with impactv U s e t h e o b je c t- o ri e nt e d f u nc t io n s f o r c o m p le t e c u s to m is a ti o n o f y o ur r e po r ts

    v D e si g n & s a ve y o ur o w n r e po r t t e mp l at e s w i th t e x t -b o xe s, g r a ph s & l i s ts o f y o ur c h o i ce f o r r ep e at e d u s e

    v I mp o rt pi c tu r es & l o go s f o r a p r of e s si o na l & c o mp l et e l o ok t o a l l y o ur re p or t s

    v D i r e ct l y i m p or t & e d i t e x te r n a l Wo r d d o c s, E x c e l w or k s h e et s o r P D F f i l e s i n D a t aV i e w e r i ts e l f u s i n g t he p o w e r f u l OL E f e a t ur e

    v E x p or t a l l do w n l o ad e d d a t a t o E x c e l f o r f u rt h e r an a l y s is o r p r in t i n g

    v P er f o r m o n e - to u c h p r i n ti n g o f t h e c o m pl e t e d r e p o rt s

    0.000

    0.501.000

    1.500

    2.000

    2.500

    3.000

    3.500

    4.000

    4.500

    5.000

    5.500

    %

    10:46:30.000 AM4/29/2005

    12:43:30.000 P M4/29/2005

    23 M in/Div1:57:00 (H:M :S )

    Specifications

    : @1 2. 8k Hz /c ha nn el 5 0H z

    Temp.

    Voltage InputsCurrent InputsPower SupplyI n t e r na l B a t t er yBattery bac k up

    Dimens ionsL C D D i s p la yOperatingWeight

    ::

    :

    :::

    ::

    :

    L - L 6 0 0V R M S; L - N 4 8 0V1 V I n pu t2 30 V A C 5 0 HzRec hargeable NiMh 9.6V8 hours

    180mmx 55mmx 240mm86mmx116mm0 d e g C t o 5 0 de g C1.5Kg

    frequenc ySamplingI n t e r na l D a t a st o r a ge m e m or y : 2 M B ( A L M 30 ) ; 4 M B ( A L M 32 )

    Accuracy

    Voltage : 0.50%Current : 0.50%Power : 1%Power fac tor : 0.01Energy : 1%

    Frequenc y : 0.01THD : 1% + 2 ptd

    T he complete kit consists of the A LM 30/32 instrument, 4 voltageprobes with crocodile clips, carrying case, PC communicationcable, Power cord, DataViewer software CD & OperationManual.

    The CTs are optional and would be supplied as per order.

    M an ac o E ne r y S ol ut io ns P vt . L td.Gc o n s e r v a t i o n b e g i n s h e r e

    H e a d O f f i c e :St

    A - 6 , S h a n t i A p t s . , 2 1 & 2 2 , 1 C r o s s S t , T T K R o a d, A l w a rp e t , C h en n a i - 1 8 .

    Tel: Fax: Email :44- 42316164 44- 42316165 [email protected] www.mes.co.inBranches:

    Ahmedabad : ahm@mes .c o.in; Ph: +91- 93271 02033

    Bangalore : blr@mes .c o.in; Ph: +91- 93410 03147

    C he nn ai : c hn @m es .c o. in ; P h: + 91 - 9 38 05 7 30 27Coimbatore : c be@mes .c o.in; Ph: +91- 93666 22334

    Hy derabad : hy d@mes .c o.in; Ph: +91- 93940 43970

    M um ba i : m mb @m es .c o. in ; P h: + 91 - 9 32 33 1 41 56

    M E S h a s a s t r a t e g i c a l l i a nc e w i t h A l ac r i t y E l e c t ro n i c s L t d . t o o f f e r t h e K R YK A R D r a n g e o f I n s t r um e n t a t io n & C o n t r ol p r o d uc t s Specifications subject to change without notice

    T rends

    B a r g ra p h s & T ab l e s

    Set up

    Del hi : del @mes .co.in; Ph: +91- 93125 46020