All Suture Anchor
with IntelliBraid Technology
Introduction Searching For a Better Option
IntelliBraid Technology
Without SC Technology
Self-Centering Technology
With SC Technology
12.0 mm
ICONIX 1
4.5 mm
3.0 mm
ICONIX 2,3,25
Measurements - Before
4.0 mm
8.0 mm
�e ICONIX family of anchors symolise the next generation of suture anchor technology. �e all suture based system allows for less bone removal during pilot hole creation without compromising pullout strength. �e innovation design is truly the �rst of its kind.
Competitive Advantages
• Four all suture configurations
• A completely all suture based implant made of HSS (Force Fiber) and a polyester sheath
• Helps eliminate the possibility of loose bodies in the joint due to anchor breakage
ICONIX 11 strand #2 Force FiberUse w/1.4mm instrumentation
ICONIX 22 strands #2 Force FiberUse w/2.3mm instrumentation
ICONIX 33 strands #2 Force Fiber Use w/2.3mm instrumentation
ICONIX 252 strands #5 Force FiberUse w/2.3mm instrumentation
• Smaller drill allows for minimal bone removal during pilot hole creation
• More anchors can be placed in smaller footprint
Typical3.0mm Drill Hole
ICONIX2.3mm Drill Hole
ICONIX1.4mm Drill Hole
Anchors
Pilot Hole
• The ICONIX Anchor System is intelligently sized and color coded to reduce risk of human error
Intelligent Design
2.3mm1.4mm
Competitive Advantages
• Smaller drill guides cause less damage to surrounding tissue
• Universal crown tips can be used on the face and rim of the glenoid
• Options when you need them
• The ICONIX Anchor System was specifically designed for both Rotator Cuff and Instability repairs, with curved and straight option guides
Rotator Cuff
Instability
Straight Short
Straight
12º
25º
2.3mm 1.4mm
Guides
Competitive Advantages• The ICONIX Anchor System is specifically designed for Hip FAI procedures with curved and straight guide options
• Designed to provide proper guide length during all FAI cases
• Directs anchor trajectory away from the acetabular socket
• Unique SLANT mouth helps place anchor closer to the acetabulum rim, allowing for a more anatomic repair
2.3mm 1.4mm12º Slant
25º Slant
3mm
Hip - FAI
TechniqueRotator Cuff
Instability
Hip - FAI
Take selected drill guide and place on bone in preferred position.
Insert the awl or drill into the drill guide and advance until positive stop is hit.
Insert anchor, lightly mallet to fully seat the anchor into the bone until positive stop is hit. Untether the suture from the inserter handle. Pull the anchor inserter handle. Pull on all sutures to set the anchor.
Take selected drill guide and place on bone in preferred position.
Insert the drill into the drill guide and advance until positive stop is hit.
Insert anchor, lightly mallet to fully seat the anchor into the bone until positive stop is hit. Untether the suture from the inserter handle. Pull the anchor inserter handle. Pull on all sutures to set the anchor.
(Instructions for Hip - FAI are same as for Instability)
Pull-out Strength1
Competitive Advantages
Stryker ICONIX 25
Stryker ICONIX 3
Stryker ICONIX 2
Stryker ICONIX 1
Biomet JuggerKnotsingle loaded
Linvatec Y-Knotsingle loaded
0 100 200 300 400 500 600
Anchor
Ultimate Pull-out Force (N)
One pound force is approximately equal to 4.5 Newtons
• Cannulated obturators help save time while gaining access to the hip joint
Cannulated Obturator
References:Tech Report # RD-12-080
PART NUMBER DESCRIPTION
3910-500-512
3910-500-522
3910-500-532
3910-500-525
3910-500-550
3910-500-551
3910-500-552
3910-500-553
3910-500-554
3910-500-555
3910-500-556
3910-500-557
3910-500-558
3910-500-559
3910-500-560
3910-500-561
Obturator3910-500-562
3910-500-563
3910-500-564
3910-500-565
Drills / Awl3910-500-568
3910-500-569
3910-500-571
3910-500-573
3910-500-574
Tray3910-500-575
ICO with IntelliBraid Technology Ancho with 1 stran Force Fiber
ICO with IntelliBraid Technology Anchor with 2 strands #2 Force Fiber
ICO with IntelliBraid Technology Anchor with 3 strands #2 Force Fiber
ICONIX 25 with IntelliBraid Technology Anchor with 2 strands #5 Force Fiber
ICONIX Straight Guide SHORT for 1.4mm anchor
ICONIX Straight Guide SHORT for 2.3mm anchor
ICONIX Straight Guide for 1.4mm anchor
ICONIX 12º Guide for 1.4mm anchor
ICONIX 25º Guide for 1.4mm anchor
ICONIX Straight Guide for 2.3mm anchor
ICONIX 12º Guide for 2.3mm anchor
ICONIX 25º Guide for 2.3mm anchor
ICONIX SLANT 12º Guide for 1.4mm anchor
ICONIX SLANT 25º Guide for 1.4mm anchor
ICONIX SLANT 12º Guide for 2.3mm anchor
ICONIX SLANT 25º Guide for 2.3mm anchor
ICONIX Pencil Tip Obturator SHORT for 1.4mm anchor
ICONIX Pencil Tip Obturator SHORT for 2.3mm anchor
ICONIX Trocar Tip Obturator for 1.4mm anchor
ICONIX Trocar Tip Obturator for 2.3mm anchor
ICONIX 1.4mm Disposable Drill
ICONIX 2.3mm Disposable Drill
ICONIX 1.4mm Reusable Straight Drill
ICONIX 2.3mm Reusable Straight Drill
ICONIX 2.3mm Reusable Awl
Multi-System Reusable Tray
Anchors
Guides
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery.
The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Products referenced with ™ designation are trademarks of Stryker. Products referenced with ® designated are registered trademarks of Stryker. Copyright © 2014 Stryker. Printed in Australia.
Literature Number: LJPICX-BSSP MS/GS 09/12
Stryker Australia 8 Herbert Street, St Leonards NSW 2065 T: 61 2 9467 1000 F: 61 2 9467 1010
Stryker New Zealand515 Mt Wellington Highway, Mt Wellington Auckland T: 64 9 573 1890 F: 64 9 573 1891
For more information contact your local Stryker Sales Representative
www.stryker.com