aisin-as68rc-tech-info.pdf
TRANSCRIPT
8/11/2019 aisin-as68rc-Tech-Info.pdf
http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 1/5
8/11/2019 aisin-as68rc-Tech-Info.pdf
http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 2/5
Solenoid application chart with pressure switch states.
All 8 pressure switches are normally “open” meaning they makecontact when there is pressure in the circuit.
Shift sol. 1,2,3 and 4 are normally “closed” on /off solenoids.
Linear sol. “B” is PWM sol. Normally applied.
Linear sol. A,C are PWM sol’s and D are normally vented.
Limp in mode works as follows: if a fault occurs in 4
th
, 5
th
, or 6
th
gearunit will fail to 5
th gear until safe to downshift to 3
rd.
If fault occurs in 1st
, 2nd
, or 3rd
gear unit will fail to 3rd
gear.
You will always have Reverse.
8/11/2019 aisin-as68rc-Tech-Info.pdf
http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 3/5
Line pressure testing
8/11/2019 aisin-as68rc-Tech-Info.pdf
http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 4/5
Connector pinouts for solenoids and switches
8/11/2019 aisin-as68rc-Tech-Info.pdf
http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 5/5
Pinouts for Range sensor