agn monitoring workshop mpifr 14/15 march 2011

14
1 AGN Monitoring Workshop MPIFR 14/15 March 2011 Reduction and first results of F-GAMMA data I. Nestoras on behalf of the F-GAMMA team

Upload: marged

Post on 24-Feb-2016

46 views

Category:

Documents


0 download

DESCRIPTION

AGN Monitoring Workshop MPIFR 14/15 March 2011. Reduction and first results of F-GAMMA data. I. Nestoras on behalf of the F-GAMMA team. General information . Coordinated observations at Effelsberg and PV Typical 48h per session for Effelsberg / 12h for PV - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: AGN Monitoring Workshop MPIFR 14/15 March 2011

1

AGN Monitoring WorkshopMPIFR 14/15 March 2011

Reduction and first results of F-GAMMA data

I. Nestoras on behalf of the F-GAMMA team

Page 2: AGN Monitoring Workshop MPIFR 14/15 March 2011

2

General information

• Coordinated observations at Effelsberg and PV • Typical 48h per session for Effelsberg / 12h for

PV • Cross scans in Azi/Elv for Effelsberg

• Wobbling / calibrated cross scans for PV

• New system in Effelsberg (July 2010) • Change to EMIR receivers at IRAM (April 2009) Observing at Horizontal / Vertical polarizations

Page 3: AGN Monitoring Workshop MPIFR 14/15 March 2011

3

• Standard reduction procedures now semi-automatic (Code by E. Angelakis , A. Kraus)

• Gain Curve Correction

• Opacity Correction

• Pointing Corrections

• Absolute calibration• (Calibrators: 3C 286,etc.)

Effelsberg

Observing Wavelengths : 11cm to 7mm (8 frequencies)

• Accuracy ~ < 5% at high frequencies (Angelakis et.al 2008)

Page 4: AGN Monitoring Workshop MPIFR 14/15 March 2011

4

Effelsberg - Calibration

Page 5: AGN Monitoring Workshop MPIFR 14/15 March 2011

5

Some results

Spectra of 0235+164(BL LAC)

Light Curve of 0235+164 (BL LAC)

Page 6: AGN Monitoring Workshop MPIFR 14/15 March 2011

6

Some results

Spectra of 2251+158 (3C 454.3)(FSRQ)

Light Curve of 2251+158 (3C 454.3)(FSRQ)

Page 7: AGN Monitoring Workshop MPIFR 14/15 March 2011

7

• Reduction with Mira and IDL software

• Averaging of sub-scans in Azi/Elv

• Gain Curve Correction

• Opacity Correction

• Pointing Corrections

• Absolute calibration (Main calibrators Mars, Uranus) • Average polarizations for EMIR (Horizontal / Vertical)

IRAM - PVObserving Wavelengths : 3, 2,

1mm

• Accuracy ~ < 10%

New receiver (EMIR) since May 2009

Page 8: AGN Monitoring Workshop MPIFR 14/15 March 2011

8

IRAM – PV Flagging

First/basic filter on the data : • changes of data format• remove data that had an ambiguous fit• negative values• remove first scan before focus for calibrators Second pass filter :• pointing offset Remove all data for which the pointing offset is larger than 0.35*HPBW • fitting width Remove all data for which the width is larger than HPBW +- 0.45*HPBW

Third pass filter : After averaging of sub-scans apply again first and second filters

Page 9: AGN Monitoring Workshop MPIFR 14/15 March 2011

9

IRAM – PV Error estimation

• Propagated error with every operation

• In every average operation also the scatter of the elements is added

Page 10: AGN Monitoring Workshop MPIFR 14/15 March 2011

10

IRAM – PV Error estimationIn more detail :

• Scatter of measurements in each direction• Fit error in every scan and direction (Azi/Elv) Initial error per direction

Final error :

Propagated error per direction after pointing, opacity and gain curve correction

Calibration error :The error in each calibration factor is the propagated error of each calibration measurement and the corresponding error in the assumed model. The final calibration factor

is the average of all the available factors

The propagated error after the sensitivity correction

Page 11: AGN Monitoring Workshop MPIFR 14/15 March 2011

11

IRAM – PV Calibration

Page 12: AGN Monitoring Workshop MPIFR 14/15 March 2011

12

IRAM – PV Calibration

Page 13: AGN Monitoring Workshop MPIFR 14/15 March 2011

13

Effelsberg/IRAM Cross Calibration

Page 14: AGN Monitoring Workshop MPIFR 14/15 March 2011

14

Some results

40.781.580.891.194.298.393.593.596.893.5%

2mm3mm7mm9mm13mm20mm28mm36mm60mm110mm-

Percentage of variable sources per

frequency