Index
ItemTest
DescriptionReference
Date of Test(D/M/Y)
Result Location of Test Page
A. Characteristic Tests
A-1 Visual inspection EN 50155:2001, 10.2.1 PASS AAEON LAB 3
A-2Performance Test(where applicable)
EN 50155:2001, 10.2.2 Supply variations: 0,7 UPASS Cerpass 3
A-3 Insulation test EN 50155:2001, 10.2.9.1 500 V DC PASS Cerpass 3
A-4Voltage withstandtest
EN 50155:2001, 10.2.9.2 1000 Vrms, sinusoidalPASS Cerpass 3
B. Environmental Tests
B-1 Cooling testEN 50155:2001, 10.2.3EN60068-2-1, Ad
Ambient temperature: TX:Internal cubicleTemp 0~+55
PASS AAEON LAB 3
B-2 Dry heat testEN 50155:2001, 10.2.4EN60068-2-2, Bd
PASS AAEON LAB 4
B-3Vibration, Shock,and Bump test
EN50155:2001, 10.2.11EN 61373
PASS King Design 5
B-4 Damp heat testcyclic
EN50155:2001, 10.2.5EN 60068-2-30, Db
+25C/+55C @ 2 x 24h,2cycles
PASS AAEON LAB 11
C. EMC Tests
C-3Conductedemission
EN 50155:2001, 10.2.8.2EN 50121-3-2 (Table 4)EN 55011
79 dBV QP @ 150 - 500 kHz73 dBV QP @ 500 kHz - 5 MHz73 dBV QP @ 5MHz - 30 MHz
PASSCOMPLIANCELAB
12
C-4 Radiated emission
EN 50155:2001, 10.2.8.2EN 50121-3-2(Table 6)EN 55011
40 dBV/m QP @ 30 230kHz,10m47 dBV/m QP @ 230-1GHz,10m
PASSCOMPLIANCELAB
15
C-5Fast transient burstimmunity
EN 50155:2001, 10.2.7EN 50121-3-2 (Table 8)EN 61000-4-4
2 kV (capacitive clamp)
PC = A PASSCOMPLIANCELAB
20
C-6 Surge immunityEN 50155:2001, 10.2.6.2EN 50121-3-2 (Table 7)
1,8 kV, 5/50 us
2 Kv
PC = B
PASSCOMPLIANCELAB
22
C-7RFI immunity,Conducted
EN 50155:2001, 10.2.8.1EN 50121-3-2 (Table 7)EN 61000-4-6
10Vrms @ 0.15 - 80 MHz, 80 %AM (1 kHz)PC = A
PASSCOMPLIANCELAB
24
C-8RFI immunity,radiated
EN 50155:2001, 10.2.8.1EN 50121-3-2 (Table 9)EN 61000-4-3
10 V/m @ 80 - 1000 MHz, 80 %AM (1 kHz)PC = A
PASSCOMPLIANCELAB
26
C-9Electrostaticdischarge
EN 50155:2001, 10.2.6.4EN 50121-3-2 (Table 9)EN 61000-4-2
6 kV contact discharge
8 kV air discharge
PC = B
PASSCOMPLIANCELAB
28
-
8/10/2019 AEC-6910 en-50155 Test Report
3/29
R/N:Page: 3 of 68
A. Characteristic Tests
A-1 Visual inspectionA-1-1 Inspection Request
The visual inspection shall be carrier out to ensure that the equipment is of sound construction and, so far
as can be ascertained, meets its specified requirements.A-1-2 Inspection Result
Pass:This is a FAN less product, therefore without any noise leakage except the Hard Disk Driver motor.
A-2 Performance Test (where applicable)A-2-1 Test Condition
1. Supply variations:- Supply voltage: (1) rated input voltage x 0.7 (2) rated input voltage x 1.25- Operation function shall be worked normally at the supply variations.
2. Supply interruption:- Supply voltage: rated input voltage.- Interruption classification: Class S1.- Repeated 10 times at random and covered all modes of operation.
- Operation function shall be worked normally at supply variations.A-2-2 Test Result
1. Supply variations:
Test voltage (V) Result / Observation
DC 23.75 No malfunction
DC 13.3 No malfunction
2. Supply interruption:
Test voltage (V) Result / Observation
DC 19 No malfunction
A-3 Insulation testA-3-1 Test Condition
- Test voltage: 500 Vdc.- No fundamental deterioration from the initial measurement.- Test voltage is applied between the power supply sides of external power adaptor and I/O ports
equipment under test.
A-3-2 Test Result
Test voltage (V) Result / Observation
DC 500 No fundamental deterioration
A-4 Voltage withstand testA-4-1 Test Condition
- Test voltage: 1000 Vac or 1414Vdc.- Test time: one minute.- Neither disruptive discharge nor flashover shall occur.- Test voltage is applied between the power supply sides of external power adaptor and I/O ports
equipment under test.
A-4-2 Test Result
Test voltage (V) Result / Observation
DC 1414 No disruptive discharge / no flashover
B. Environmental TestsB-1 Cooling test
B-1-1 Test EquipmentProgrammable Temperature & Humidity ChamberK.SON. INS. TECH. CORP.Model: TS-F3L+-100
Date of Calibration: 04/01/05
-
8/10/2019 AEC-6910 en-50155 Test Report
4/29
R/N:Page: 4 of 68
Serial Number: 1467
B-1-2 Test Condition
1. Test Temperature: 02. Test Times: 96Hrs3. Test Software: Windows 2000 / Run PassMark Burn In Test Pro 4.0
B-1-3 Machine Curve
B-1-4 Test Result
The system structure doesnt have any deformation; All functions are passed after low temperature
operation test.
B-2. Dry heat test
B-2-1 Test EquipmentProgrammable Temperature & Humidity ChamberK.SON. INS. TECH. CORP.Model: TS-F3L+-100
Date of Calibration: 04/01/05Serial Number: 1467
B-2-2 Test Condition
1. Test Temperature: 552. Test Times: 96Hrs3. Test Software: Windows 2000 / Run PassMark Burn In Test Pro 4.0
B-2-3 Machine Curve
-
8/10/2019 AEC-6910 en-50155 Test Report
5/29
R/N:Page: 5 of 68
B-2-4 Test ResultThe system structure doesnt have any deformation; All functions are passed after high temperature
operation test.
B-3 Vibration, Shock, and Bump testB-3-1 Test Equipment
SHOCK TEST
EQUIPMENT MFR MODELSERIAL
NUMBER
CAL.
DUE
Shock Testing System King Design KD-DP-1200-60 KDS11054989 No Cal. Required
Controller King Design KD-1200-03 KD674 No Cal. Required
Accelerometer B&K B&K 4398 2209043 No Cal. Required
VIBRATION TEST
EQUIPMENT MFR MODELSERIAL
NUMBER
CAL.
DUE
Vibration Tester King DesignKD-9363EM-600F2K-
50N120KDS11054783 No Cal. Required
Controller DACTRON FRONT-End Box 5250251 No Cal. Required
Control Accelerometer Wilcoxon Research WR-77 4208 No Cal. Required
B-3-2 Shock Test ConditionTemperature : 202
Humidity : 7020%RHEUT : AEC-6910 with HDDWave From : Half sine wave(operation)Acceleration : 30gDuration Time : 18msNo. of Shock : Each axis 3 timesShock of direction : X, Y, Z axis
-
8/10/2019 AEC-6910 en-50155 Test Report
6/29
R/N:Page: 6 of 68
B-3-3 Shock Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
7/29
R/N:Page: 7 of 68
B-3-4 Shock Test Curve
-
8/10/2019 AEC-6910 en-50155 Test Report
8/29
R/N:Page: 8 of 68
B-3-5 Shock Test Result
B-3-6 Vibration Test Condition
Temperature : 202
Humidity : 7020%RH
-
8/10/2019 AEC-6910 en-50155 Test Report
9/29
R/N:Page: 9 of 68
EUT : AEC-6910 with HDDWave From : Random vibration test(operation)
Test Axis : VerticalFrequency : 5~20 Hz
Acceleration : 5.40 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct10~100 Hz 0.190 (m/s)/Hz
100~250 Hz -6 dB/OctTest Time : 1 hr
Test Axis : TransverseFrequency : 5~250 HzAcceleration : 4.71 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct
10~100 Hz 0.144 (m/s)/Hz
100~250 Hz -6 dB/OctTest Time : 1 hr
Acceleration : 5.40m/s rmsAcceleration : 5.40m/s rms
Test Axis : Longitudinal axisFrequency : 5~250 HzAcceleration : 2.52 m/s rms
P.S.D. : 5~10 Hz +9 dB/Oct10~100 Hz 0.0414 (m/s)/Hz
100~250 Hz -6 dB/OctTest Time : 1 hr
Total test Time : 3 hrs
B-3-7 Vibration Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
10/29
R/N:Page: 10 of 68
B-3-8 Vibration Test Curve
-
8/10/2019 AEC-6910 en-50155 Test Report
11/29
R/N:Page: 11 of 68
B-3-5 Vibration Test Result
B-4. Damp heat test cyclicB-4-1 Test Equipment
Programmable Temperature & Humidity ChamberK.SON. INS. TECH. CORP.Model: TS-F3L+-100
Date of Calibration: 04/01/05Serial Number: 1467
B-4-2 Test Condition
1. Test Temperature: 25 / 552. Test Humidity: 93~95%RH3. Test Cycle: 2 Cycle
B-4-3 Machine Curve
-
8/10/2019 AEC-6910 en-50155 Test Report
12/29
R/N:Page: 12 of 68
3 h 6 h
95%
93%
24 h (1 Cycle)
25
9 h
T1
Ambient temp.
10 min
relative humidity
45 to 75%
dielectric test
B-4-4 Test ResultPass: The system structure doesnt have any deformation; All functions are passed during humidity test.
C. EMC TestsC-1 EUT DESCRIPTIONProduct Embedded Control PC
Trade Name AAEON
Model AEC-6910
Housing Type Metal case
EUT Power Rating 100~240VAC
AC Power During Test 230VAC / 50Hz
Power Adaptor Manufacturer FSP
Power Adaptor Model Number FSP120-AAB
Power Adaptor Power Rating I/P: 100-240VAC 50-60Hz O/P: 19VDC
AC Power Cord Type Unshielded, 1.8m (Detachable)
DC Power Cord Type Unshielded, 1.6m (Non-detachable, with a core)EUT I/O Cable Unshielded, 0.3m (Detachable)
OSC/Clock Frequencies 32.768kHz; 14.31818MHz; 25MHz
C-2 I/O PORT OF EUT
I/O Port Type QTY TESTED WITH
PIO Port 1 1
SIO Port 4 4
PS/2 Keyboard Port 1 1
PS/2 Mouse Port 1 1
VIDEO-OUT Port (VGA) 1 1
AUDIO IN/OUT/ MIC Port 1 1
LAN Port 1 1USB Port 4 4
PCMCI Port 2 2
CF Slot 1 1
C-3 Conducted emission
C-3-1 Test Equipment
Conducted Emission Test Site # B
EQUIPMENT MFR MODELSERIAL
NUMBER
CAL.
DUE
TEST RECEIVER R&S ESHS10 843743/015 03/31/2006
LISN (EUT) EMCO 3825/2 9106-1810 01/16/2006LISN EMCO 3825/2 1382 01/16/2006
BNC CABLE MIYAZAKI 5D-FB BNC B1 07/14/2006
Pulse Limiter R&S ESH3-Z2 100374 08/25/2006
THERMO-HYGRO METER TOP HA-202 9303-3 03/02/2006
-
8/10/2019 AEC-6910 en-50155 Test Report
13/29
-
8/10/2019 AEC-6910 en-50155 Test Report
14/29
R/N:Page: 14 of 68
-
8/10/2019 AEC-6910 en-50155 Test Report
15/29
R/N:Page: 15 of 68
C-3-4 Performance and Result:Pass:No any emission over the limit line.
C-4. Radiated emission
C-4-1 Test Equipment
Open Area Test Site J
EQUIPMENT MFR MODEL SERIAL no. CAL. DUE
SITE NSA CCS J Site N/A 10/15/2006
MEASURE RECEIVER SCHAFFNER SCR3501 330 06/13/2006
-
8/10/2019 AEC-6910 en-50155 Test Report
16/29
R/N:Page: 16 of 68
SPECTRUM ANALYZER ADVANTEST R3132 120900003 No Cal. Required
ANTENNA SCHAFFNER CBL 6112B 2800 09/24/2006
PRE-AMPLIFIER SCHAFFNER CPA9231A 3629 10/08/2006
CABLE BELDEN 9913 N-TYPE #J2 02/18/2006
ATTENUATOR MCL UNAT-6 AT06-8 12/03/2005
THERMO-HYGRO METER TFA N/A NO.3 11/02/2006
C-4-2 Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
17/29
R/N:Page: 17 of 68
C-4-2 Emission Profile
-
8/10/2019 AEC-6910 en-50155 Test Report
18/29
-
8/10/2019 AEC-6910 en-50155 Test Report
19/29
R/N:Page: 19 of 68
C-4-3 Performance and Result:Pass:No any emission over the limit line.
-
8/10/2019 AEC-6910 en-50155 Test Report
20/29
R/N:Page: 20 of 68
C-5. Fast transient burst immunityC-5-1 Test Equipment
Fast Transients/Burst Test Site (EN 61000-4-4)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / EFT Generator BEST EMC V2.3 200031A024SC 11/07/2006
Schaffner / Capacitive Clamp N/A N/A No Cal. Required
C-5-2 Test ConditionPort : AC Power Port and RJ45 PortBasic Standard : IEC/EN 61000-4-4
Requirements : 2 kV for AC Power Port 2 kV for RJ45 Port
Performance Criterion : The Equipment or System shall be able to provide the essential performance andremain safe.
Tested by : ALEX PANTemperature : 18
oC
Humidity : 56%Pressure : 1005mbar
C-5-3 Test Block Diagram of Test Setup
Controller Computer
EFT/Burst/Surge Generator
EUT SupportUnits
0.8mNon-Conductive Table
AC
Injection ClampBurst Generator
To Load
AC
Comm. Line 3 m
EUT
80cmNon-Conductive
Table
10cm
C-5-4 Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
21/29
R/N:Page: 21 of 68
(IEC 61000-4-4 FOR I/O)
C-5-5 Performance and ResultImpulse Frequency : 5kHzTr/Th : 5/50nsBurst Duration : 15msBurst Period : 300ms
-
8/10/2019 AEC-6910 en-50155 Test Report
22/29
R/N:Page: 22 of 68
Inject Line Voltage kV Inject Method Result (Pass/Fail)
L 2 Direct Pass
N 2 Direct Pass
PE 2 Direct Pass
L + N 2 Direct PassL + PE 2 Direct Pass
N + PE 2 Direct Pass
L + N + PE 2 Direct Pass
RJ45 2 Clamp Pass
Pass:No function degraded during the tests.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.
C6 Surge immunityC-6-1 Test Equipment
Surge Immunity Test Site (EN 61000-4-5)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / Surger Generator BEST EMC V2.3 200031A024SC 11/07/2006
Schaffner / Signal and Data
Lines Coupling NetworkCDN118 19328 No Cal. Required
C-6-2 Test ConditionPort : AC Power PortBasic Standard : IEC/EN 61000-4-5
Requirements : 2 kV(Line to Ground)) for AC Power Port
1.8kV(Line to Line) for AC Power PortPerformance Criteria : The Equipment or System shall be able to provide the
essential performance and remain safe.Tested by : ALEX PANTemperature : 20
oC
Humidity : 56%Pressure : 1010mbar
C-6-3 Test Block Diagram of Test Setup
Surge Immunity
Test
Controller Computer
EUT
&
Support Units
0.8m
To AC
Source
C-6-4 Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
23/29
R/N:Page: 23 of 68
C-6-5 Test Procedure1. The EUT and support units were located on a wooden table 0.8 m away from ground floor.
2. Injected test voltage to the EUT ports from minimum to standard request or client request.3. Recorded the test result as shown in following table.
C-6-6 Performance and ResultVoltage Waveform : 5/50 usCurrent Waveform : 8/20 usPolarity : Positive/NegativePhase angle : 0
o, 90
o, 270
o
Number of Test : 5
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
L1-L2 11.8 Positive Capacitive Pass
L1-PE 12 Positive Capacitive Pass
L2-PE 12 Positive Capacitive Pass
L1-L2 11.8 Negative Capacitive Pass
L1-PE 12 Negative Capacitive Pass
L2-PE 12 Negative Capacitive Pass
Pass : Where normal functioning of LAN cant be achieved because of the impact of CDN on the EUT, notest be required.
The apparatus continues to operate as intended. No degradation of performance or loss of function is
allowed below a performance level specified by the manufacturer, when the apparatus is used as
intended. In some cases the performance level may be replaced by a permissible loss of performance.
-
8/10/2019 AEC-6910 en-50155 Test Report
24/29
R/N:Page: 24 of 68
C-7 RFI immunity, Conducted
C-7-1 Test Equipment
CS test (EN 61000-4-6)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / RF Generator NSG 2070-1 1061 08/03/2006Schaffner / CDN CDN M316 19600 08/02/2006
Schaffner / CDN CDN M216 19294 08/02/2006
FCC / CDN FCC-801-M3-16A 99122 08/02/2006
Schaffner / EM Clamp KEMZ 801 19227 02/23/2006
Schaffner / CDN CDN T002 15881 01/13/2006
FCC / CDN FCC-801-T8-RJ45 04025 06/23/2006
Schaffner / Attenuator INA2070-1 2061 No Cal. Required
FCC / CDN FCC-801-T4-RJ45 04031 08/02/2006
C-7-2 Test Condition
Port : AC Power Port and RJ45 PortBasic Standard : IEC/EN 61000-4-6Requirements : 10V, with 80% AM. 1kHz Modulation.Injection Method : CDN-M3 for AC Power Port
CDN-T4 for RJ45 PortPerformance Criterion : A (Standard Required)Tested by : ALEX PANTemperature : 20
oC
Humidity : 56%Pressure : 1010mbarFrequency Range : 0.15MHz-80MHzFrequency Step : 1% of fundamentalDwell Time : 3 sec
C-7-3 Test Block Diagram of Test Setup
CDN
EUT and
Support units Power
AmplifierPC
Controller
Ground Reference
10 cm isolation
supporter
0.1m< L
-
8/10/2019 AEC-6910 en-50155 Test Report
25/29
R/N:Page: 25 of 68
C-7-5 Test Procedure1. The EUT and support units were located at a ground reference plane with the interposition of a 0.1 m
thickness insulating support and the CDN was located on GRP directly.2. Set the testing parameters of CS test software as per IEC/EN 61000-4-6.
C-7-6 Performance and Result:
-
8/10/2019 AEC-6910 en-50155 Test Report
26/29
R/N:Page: 26 of 68
Range (MHz) Field Modulation Result (Pass/Fail)
0.15-80 10V Yes Pass
Pass:No function degraded during the tests.The apparatus continues to operate as intended. No degradation of performance or loss of function isallowed below a performance level specified by the manufacturer, when the apparatus is used asintended. In some cases the performance level may be replaced by a permissible loss of performance.
C-8 RFI immunity, radiatedC-8-1 Test Equipment
Radiated Electromagnetic Field Immunity Test Site (EN 61000-4-3)
Manufacturer/Type Model No. Serial No. Cal. Due
Calibration of Field Chamber#RS RS3H-7 / RS3V-7 07/01/2006
Agilent / Signal Generator E4421B MY43350597 05/16/2006
AR / Electric Field Probe FP6001 305650 02/03/2006
Boonton / RF Voltmeter 9200B 328001AE 02/23/2006
BNC / Function Generator 625A 25451 02/17/2006
AR / Amplifier 100W1000M1 17564 No Cal. RequiredWerlatone Inc. / Direction Coupler C2630 4121 No Cal.Required
Frankonia /Broadband Antenna BTA-M 030001M No Cal. Required
TOP / Thermo-Hygro meter HA-202 9303-2 03/02/2006
C-8-2 Test Condiction
Port : EnclosureBasic Standard : IEC/EN 61000-4-3Requirements : 10V/m / with 80% AM. 1kHz Modulation.Performance Criterion : A (Standard Required)Tested by : ALEX PANTemperature : 18
oC
Humidity : 56%Pressure : 1010mbar
C-8-3 Test Block Diagram of Test Setup
0.8m
Power Amp Signal
GeneratorEUT Monitoring by
using a camera
Control Room
7x3x3
EUT &
Support Units
PC Controller to
control S.G. & PA as
well as forward
power
3 meter
1.5 meter
-
8/10/2019 AEC-6910 en-50155 Test Report
27/29
R/N:Page: 27 of 68
C-8-4 Test Procedure1. The EUT and support units were located at the edge of supporting table keep 3 meter away from
transmitting antenna, it just the calibrated square area of field uniformity.2. Adjusting the cables to be exposed to the electromagnetic filed as possible.
3. Performing a Radiated Emission Scan in range of 80 to 1000 MHz prior to do RS test and records themore higher emission frequencies for the reference of RS test, due to antenna effectiveness.
4. Adjusting the monitoring camera to monitor the H message as clear as possible.5. Setting the testing parameters of RS test software per IEC 61000-4-3.6. Referring to the tested data of step 3 to performing the RS test from 30 to 2300 MHz.7. Recording the test result in following table.8. Changing the EUT to the other side and repeat step 3 to 6, until 4 sides of EUT were verified.
C-8-5 Test Photograph of test setup
C-8-6 Performance and Result:
Test level : 10V/m
Steps : 1 % of fundamental
Dwell Time : 3 sec
Range (MHz) Field Modulation Polarity Position () Result (Pass/Fail)
80-1000 10V/m Yes H Front Pass
80-1000 10V/m Yes V Front Pass
80-1000 10V/m Yes H Right Pass
80-1000 10V/m Yes V Right Pass
80-1000 10V/m Yes H Back Pass
80-1000 10V/m Yes V Back Pass
80-1000 10V/m Yes H Left Pass
80-1000 10V/m Yes V Left Pass
Pass:No function degraded during the tests.The apparatus continues to operate as intended. No degradation of performance or loss of function isallowed below a performance level specified by the manufacturer, when the apparatus is used asintended. In some cases the performance level may be replaced by a permissible loss of performance.
-
8/10/2019 AEC-6910 en-50155 Test Report
28/29
R/N:Page: 28 of 68
C-9 Electrostatic dischargeC-9-1 Test Equipment
ESD Test Site (EN 61000-4-2)
Manufacturer/Type Model No. Serial No. Cal. Due
Schaffner / ESD Simulator NSG 438 129 04/20/2006
Sato / Aneroid Barometer 7610-20 89090 08/29/2006TOP / Thermo-Hygro meter HA-202 9303-1 03/02/2006
C-9-2 Test Condition
Port : EnclosureBasic Standard : IEC/EN 61000-4-2Test Level : 8kV (Air Discharge)
6kV (Contact Discharge)Performance Criterion : The Equipment or System shall be able to provide the
essential performance and remain safe.Tested by : ELVIS ZENGTemperature : 19
oC
Humidity : 59% RH
Pressure : 1005mbar
C-9-3 Test Block Diagram of Test Setup
Ground Reference Plane
Wooden Table
Indirect
Support units
EUT & its direct
Support Units
VCP
HCP
>1m
0.8m
(The 470 k resistors are installed per standard requirement.)
C-9-4 Test Photograph of test setup
-
8/10/2019 AEC-6910 en-50155 Test Report
29/29
R/N:Page: 29 of 68
C-9-5Test Performance and ResultThe electrostatic discharges were applied as follows:
Amount of Discharges Voltage Coupling Result20 / Point 8kV Air Discharge Pass
20 / Point 6 kV Contact Discharge Pass
20 / Point 2, 4, 6 kV Indirect Discharge HCP Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Front) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Left) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Back) Pass
20 / Point 2, 4, 6 kV Indirect Discharge VCP (Right) Pass
Observation: No function degraded during the tests.