adventure central -kitchen modifications & upgrades · q-101 food service equipment plan q-102...

27
1370 Vanguard Boulevard // Miamisburg, Ohio 45342 Phone: 937.438.0978 // Fax: 937.438.0379 © Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED Time / Date: FILE NO. File: Drawing: REVISION INFORMATION 6/28/2019 2:44:09 PM C:\Users\TJFinney\Documents\ADV CEN_AC_v18_tim.finney.rvt COVER SHEET G-001 FIVE RIVERS METROPARKS 3695800 ADVENTURE CENTRAL - KITCHEN MODIFICATIONS & UPGRADES ADVENTURE CENTRAL - KITCHEN MODIFICATIONS & UPGRADES FIVE RIVERS METROPARKS 2222 JAMES H. MCGEE BLVD - DAYTON, OHIO G-001, COVER SHEET 2222 JAMES H. MCGEE BLVD - DAYTON, OHIO 21 JUNE 2019 SHEET INDEX SHEET # SHEET TITLE GENERAL G-001 COVER SHEET ARCHITECTURAL A-001 GENERAL INFORMATION AD101 DEMOLITION PLAN A-101 FIRST FLOOR PLAN A-131 REFLECTED CEILING AND ROOF PLANS A-201 BUILDING ELEVATIONS A-601 DOOR AND WINDOW SCHEDULE EQUIPMENT Q-101 FOOD SERVICE EQUIPMENT PLAN Q-102 FOOD SERVICE EQUIPMENT MECHANICAL AND ELECTRICAL PLANS Q-103 FOOD SERVICE EQUIPMENT HOOD DETAILS PLUMBING P-001 GENERAL INFORMATION - PLUMBING PD100 UNDERSLAB FLOOR PLAN - PLUMBING - DEMOLITION PD101 FLOOR PLAN - PLUMBING - DEMOLITION P-100 UNDERSLAB FLOOR PLAN - PLUMBING P-101 FLOOR PLAN - PLUMBING MECHANICAL M-001 GENERAL INFORMATION - MECHANICAL MD101 FLOOR PLAN - MECHANICAL DEMOLITION M-101 FLOOR PLAN - MECHANICAL M-501 DETAILS - MECHANICAL M-502 DETAILS - MECHANICAL M-601 SCHEDULES - MECHANICAL ELECTRICAL E-001 GENERAL INFORMATION - ELECTRICAL ED101 FLOOR PLAN - ELECTRICAL DEMOLITION E-101 FLOOR PLAN - LIGHTING E-201 FLOOR PLAN - ELECTRICAL E-501 SCHEDULES - ELECTRICAL E-701 ONELINE - ELECTRICAL ARCHITECTURE/INTERIOR DESIGN/STRUCTURAL BARGE DESIGN SOLUTIONS 1370 VANGUARD BLVD. MIAMISBURG, OH 4534 PLUMBING/MECHANICAL/ELECTRICAL ADVANCED ENGINEERING CONSULTANTS 1405 DUBLIN RD. COLUMBUS, OH 43215 FOOD SERVICE EQUIPMENT VORNDRAN & ASSOCIATES 3125 STERLING RIDGE COVE FORT WAYNE, IN 46825 R E V . D R C H K D A T E : D E S C R I P T I O N : PROJECT SITE VICINITY MAP LOCATION MAP CONTRACTOR STAGING / LAYDOWN AREA 06-28-19

Upload: others

Post on 14-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

1370 V

anguard

Boule

vard

//

Mia

mis

burg

, O

hio

45342

Phone:

937.4

38.0

978 /

/ F

ax:

937.4

38.0

379

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:44:0

9 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

CO

VE

R S

HE

ET

G-001

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

ADVENTURE CENTRAL - KITCHEN

MODIFICATIONS & UPGRADES

FIVE RIVERS METROPARKS

2222 JAMES H. MCGEE BLVD - DAYTON, OHIO

G-0

01,

CO

VE

R S

HE

ET

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

21 JUNE 2019

SHEET INDEX

SHEET

# SHEET TITLEGENERAL

G-001 COVER SHEET

ARCHITECTURAL

A-001 GENERAL INFORMATION

AD101 DEMOLITION PLAN

A-101 FIRST FLOOR PLAN

A-131 REFLECTED CEILING AND ROOF PLANS

A-201 BUILDING ELEVATIONS

A-601 DOOR AND WINDOW SCHEDULE

EQUIPMENT

Q-101 FOOD SERVICE EQUIPMENT PLAN

Q-102 FOOD SERVICE EQUIPMENT MECHANICAL ANDELECTRICAL PLANS

Q-103 FOOD SERVICE EQUIPMENT HOOD DETAILS

PLUMBING

P-001 GENERAL INFORMATION - PLUMBING

PD100 UNDERSLAB FLOOR PLAN - PLUMBING - DEMOLITION

PD101 FLOOR PLAN - PLUMBING - DEMOLITION

P-100 UNDERSLAB FLOOR PLAN - PLUMBING

P-101 FLOOR PLAN - PLUMBING

MECHANICAL

M-001 GENERAL INFORMATION - MECHANICAL

MD101 FLOOR PLAN - MECHANICAL DEMOLITION

M-101 FLOOR PLAN - MECHANICAL

M-501 DETAILS - MECHANICAL

M-502 DETAILS - MECHANICAL

M-601 SCHEDULES - MECHANICAL

ELECTRICAL

E-001 GENERAL INFORMATION - ELECTRICAL

ED101 FLOOR PLAN - ELECTRICAL DEMOLITION

E-101 FLOOR PLAN - LIGHTING

E-201 FLOOR PLAN - ELECTRICAL

E-501 SCHEDULES - ELECTRICAL

E-701 ONELINE - ELECTRICAL

ARCHITECTURE/INTERIOR DESIGN/STRUCTURAL

BARGE DESIGN SOLUTIONS1370 VANGUARD BLVD.MIAMISBURG, OH 4534

PLUMBING/MECHANICAL/ELECTRICAL

ADVANCED ENGINEERING CONSULTANTS1405 DUBLIN RD.

COLUMBUS, OH 43215

FOOD SERVICE EQUIPMENT

VORNDRAN & ASSOCIATES3125 STERLING RIDGE COVE

FORT WAYNE, IN 46825

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

PROJECT SITE

VICINITY MAP LOCATION MAP

CONTRACTOR STAGING / LAYDOWN AREA

06-28-19

Page 2: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

A ---------------------A LABEL CLASS A DOORA/C AIR CONDITIONA/C UNIT AIR CONDITIONING UNITA/E ARCHITECT/ENGINEERAB ANCHOR BOLTACC ACCESSIBLEACS AUTOMATIC CONTROL SYSTEMACS DR ACCESS DOORACS PNL ACCESS PANELACT ACOUSTICAL CEILING TILEADA AMERICANS WITH DISABILITIES ACTADMIN ADMINISTRATIONAFC ABOVE FINISHED COUNTERAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFS ABOVE FINISHED SLABAGGR AGGREGATEAHU AIR HANDLING UNITAIB AIR INFILTRATION BARRIERALT ALTERNATEALUM ALUMINUMANOD ANODIZEAPC ACOUSTICAL PANEL CEILINGAPPROX APPROXIMATEAR AS REQUIREDARCH ARCHITECTASC ABOVE SUSPENDED CEILINGASSY ASSEMBLYATC ACOUSTICAL TILE CEILINGAVG AVERAGEAW ARCHITECTURAL WOODWORKAWT ACOUSTICAL WALL TREATMENT

B ---------------------B LABEL CLASS B DOORBALC BALCONYBB BASEBOARDBC BOOKCASEBD BOARDBDRY BOUNDARYBFF BELOW FINISH FLOORBHMA BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATIONBLDG BUILDING BLKG BLOCKINGBLT IN BUILT-INBN BULLNOSEBOS BOTTOM OF STEELBOT BOTTOMBP BUILDING PAPERBRKT BRACKETBSMT BASEMENTBTWN BETWEENBUR BUILT-UP ROOFING

C ---------------------C CONC CAST CONCRETEC LABEL CLASS C DOORCAB CABINETCATW CATWALKCAV CAVITYCBB CEMENTITIOUS (BACKER) BOARDCD CONSTRUCTION DOCUMENTSCDW CHILLED DRINKING WATERCEM PLAS CEMENT PLASTERCER CERAMICCF CONTRACTOR FURNISHEDCF/CI CONTRACTOR FURNISHED/CONTRACTOR

INSTALLEDCFE CONTRACTOR FURNISHED EQUIPMENTCFLG COUNTERFLASHINGCFM CUBIC FEET PER MINUTECFMF COLD-FORMED METAL FRAMINGCFS CUBIC FEET PER SECONDCG CORNER GUARDCI CAST IRONCIP CAST-IN-PLACECJ CONTROL JOINTCL CENTER LINECLG CEILINGCLG DIFF CEILING DIFFUSERCLG HT CEILING HEIGHTCLL COLUMN LINECLO CLOSETCLR COLORCLRM CLASSROOMCMU CONCRETE MASONRY UNITCNDS CONDENSATECDR CARD READERCO CLEANOUTCOL COLUMNCOMM COMMUNICATIONCONC CONCRETECONC FLR CONCRETE FLOORCONF CONFERENCECONT CONTINUECOORD COORDINATECORR CORRIDORCP CONCRETE PIPECPT CARPETCR CONTROL ROOMCS CAST STONECSWK CASEWORKCT CERAMIC TILECTB CERAMIC TILE BASECTF CERAMIC TILE FLOORCTR CENTERCU FT CUBIC FEETCW CASEMENT WINDOW

D ---------------------D DEPTHD LABEL CLASS D DOORDBL DOUBLEDEMO DEMOLITIONDEPT DEPARTMENTDET DETAILDIA DIAMETERDIR DIRECTIONDIST DISTANCEDOC DOCUMENTDR DOORDS DOWNSPOUT

E ---------------------E LABEL CLASS E DOOREA EACHEF EACH FACEEIFS EXTERIOR INSULATION AND FINISH SYSTEMEJ EXPANSION JOINTES EACH SIDEEL ELEVATIONELEV ELEVATORENTR ENTRANCEEPS EXPANDED POLYSTYRENE BOARD (INSULATION)EQ EQUALEWC ELECTRIC WATER COOLEREXP EXPOSEDEXT EXTERIOREXT EXTINGUISHEREXT GR EXTERIOR GRADE

F ---------------------FA FIRE ALARMFAAP FIRE ALARM ANNUNCIATOR PANELFAS BD FASCIA BOARDFC BRK FACE BRICKFCO FLOOR CLEANOUTFD FLOOR DRAINFDTN FOUNDATIONFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFED FEDERALFF FINISH FACEFF EL FINISH FLOOR ELEVATIONFF INSUL FOIL BACKED INSULATIONFGL FIBERGLASSFH FIRE HOSEFHP FULL HEIGHT PARTITIONFIN FINISHFIN BS FINISH BOTH SIDESFIN FLR FINISH FLOORFIN GR FINISH GRADEFIXT FIXTUREFLDG FOLDINGFLEX FLEXIBLEFLG FLOORINGFLMT FLUSH MOUNTFLR FLOORFM FACTORY MUTUALFOC FACE OF CONCRETEFOM FACE OF MASONRYFR FIRE RESISTANTFRG FIBER REINFORCED GYPSUMFRMG FRAMINGFRP FIBERGLASS REINFORCED PLASTICFRTW FIRE RETARDANT TREATED WOODFS FEDERAL SPECIFICATIONFSTNR FASTENERFT FEETFTG FOOTINGFWC FABRIC WALLCOVERING

G ---------------------G NATURAL GASGALV GALVANIZEDGB GRAB BARGFCI GOVERNMENT FURNISHED CONTRACTOR

INSTALLEDGFGI GOVERNMENT INSTALLED FURNISHED

INSTALLED BY GOVERNMENTGFRG GLASS-FIBER-REINFORCED GYPSUMGLZ GLAZINGGR FL GROUND FLOORGUT GUTTERGYP BD GYPSUM BOARDGYP PLAS GYPSUM PLASTER

H ---------------------HB HOSE BIBBHDPE HIGH DENSITY POLYETHYLENEHDW HARDWAREHDWD HARDWOODHEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)HM HOLLOW METALHMD HOLLOW METAL DOORHORIZ HORIZONTALHT HEIGHTHYDR HYDRAULIC

I ---------------------IBC INTERNATIONAL BUILDING CODE INSUL INSULATIONINT INTERIORILO IN LIEU OF

J ---------------------JAN JANITOR

K ---------------------KPD KEYPADKIT KITCHENKPL KICKPLATE

L ---------------------LAM LAMINATELAV LAVATORYLBR LUMBERLBS POUNDLDG LANDINGLF LINEAR FEET (FOOT)LIB LIBRARYLIN LINEARLKR LOCKERLOC LOCATIONLT LIGHTLVDR LOUVER DOORLVR LOUVER

M ---------------------MACH RM MACHINE ROOMMATL MATERIALMAX MAXIMUMMC MOISTURE CONTENTMD METAL DECKMECH MECHANICALMECH RM MECHANICAL ROOMMEMB MEMBRANEMF MILL FINISHMFR MANUFACTURERMID MIDDLEMIL STD MILITARY STANDARDMIN MINIMUM, MINUTEMIRR MIRRORMISC MISCELLANEOUSMLDG MOLDING (MOULDING)MO MASONRY OPENINGMOD MODIFYMB MOISTURE BARRIERMTG MOUNTINGMTL METALMVBL MOVABLEMWP MEMBRANE WATERPROOFING

N ---------------------N NORTHNA NOT APPLICABLENFPA NATIONAL FIRE PROTECTION ASSOCIATIONNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNP NO PAINTNRC NOISE REDUCTION COEFFICIENTNTS NOT TO SCALE

O -------------------OA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROFD OVERFLOW DRAINOFF OFFICEOGL OBSCURE GLASSOPH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEOPQ OPAQUEOWSJ OPEN WEB STEEL JOISTOPR OPERABLEORD OVERFLOW ROOF DRAINORIG ORIGINAL

P -------------------- PA PUBLIC ADDRESS PAR PARAPET PAT PATTERN PB PULL BOX PBD PARTICLEBOARD PCC PRECAST CONCRETE PCF POUNDS PER CUBIC FOOT PCT PERCENT PERF PERFORATED PERIM PERIMETER PH PHASE PIL PILASTER PL PROPERTY LINE PL GL PLATE GLASS PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLG PILING PLYWD PLYWOOD PNL PANEL PP PL PUSH/PULL PLATE PR PAIR PRCST PRECAST PRKG PARKING PS CONC PRESTRESSED CONCRETE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED PTD PAPER TOWEL DISPENSER PTDR PAPER TOWEL DISPENSER AND RECEPTACLE

PTN PARTITION PWR POWER

Q -------------------- QT QUARRY TILE QTY QUANTITY

R -------------------- RB RESILIENT BASE RBM REINFORCED BRICK MASONRY RBR RUBBER RC REINFORCED CONCRETE RCP REFLECTED CEILING PLAN RD ROOF DRAIN RDG INS RIGID INSULATION, SOLID REC RECESSED REC RM RECREATION ROOM REF REFERENCE REM REMOVABLE REP REPAIR REPL REPLACE REQ REQUIRE REQD REQUIRED RESIL RESILIENT REST RESTROOM RF RESILIENT FLOORING RFG ROOFING RH ROOF HATCH RHR RIGHT HAND REVERSE RL ROOF LEADER RLG RAILING RM ROOM RO ROUGH OPENING RSD ROLLING STEEL DOOR RV ROOF VENT RVL REVEAL

S -------------------- SB SPLASH BLOCK SCHED SCHEDULE SD SMOKE DETECTOR SF SQUARE FOOT (FEET) SFTWD SOFTWOOD SGL SINGLE SHT MTL FLASH SHEET METAL (FLASHING) SHTHG SHEATHING SHV SHELVING SIM SIMILAR SJ SCORED JOINT SKLT SKYLIGHT SLNT SEALANT SMK SMOKE SMLS SEAMLESS SP EL SPOT ELEVATION SPEC SPECIFICATION SQ SQUARE SQ IN SQUARE INCH SQ YD SQUARE YARD SST STAINLESS STEEL ST STAIRS STD STANDARD STL JST STEEL JOIST STL RF DK STEEL ROOF DECK STOR STORAGE STR STRINGERS STRB/HRN STROBE/HORN SUB FL SUBFLOOR SV SHEET VINYL SW SIDEWALK

T -------------------- T TREAD T/S TUB/SHOWER TC TERRA COTTA TD TRENCH DRAIN TEL TELEPHONE TEMP TEMPORARY TER TERRAZZO TFF TOP OF FINISH FLOOR THK THICKNESS TK BD TACKBOARD TMPD GL TEMPERED GLASS TN TRUE NORTH TOF TOP OF FOOTING TOM TOP OF MASONRY TOP TOP OF PARAPET TOPO TOPOGRAPHY TOS TOP OF SLAB TRANS TRANSOM TRTD TREATED TV TELEVISION

A. ALL MATERIALS AND SHAPES INDICATED ARE CONTINUOUS UNLESS SPECIFICALLY NOTED OTHERWISE.

B. DETAILS, NOTES AND/OR SCHEDULES MAY SHOW SELECTED REQUIRED FASTENER TYPES, SIZES AND LOCATIONS. WHERE FASTENERS ARE SO DETAILED OR SCHEDULED, SUCH FASTENING SHALL NOT BE CONSIDERED A COMPLETE REPRESENTATION OF ALL FASTENING REQUIRED.

C. SECURE ALL NEW CONSTRUCTION WITH FASTENERS OF ADEQUATE SIZE AND AT PROPER SPACING TO ENSURE THAT ALL MATERIALS WILL REMAIN SECURELY FIXED IN POSITION AS SHOWN.

D. WHERE ACCESSORY MATERIALS ARE DETAILED, NOTED OR SPECIFIED AND NO EXTENT OF USE IS INDICATED, PROVIDE ACCESSORY MATERIALS WHEREVER USE IS POSSIBLE.

E. INSTALL NEW CONSTRUCTION USING MATERIALS, TYPE AND METHOD OF ANCHORAGE IN SUCH A WAY AS TO PROVIDE FOR EXPANSION AND CONTRACTION.

F. REFER TO ABBREVIATION LIST FOR DEFINITION OF ABBREVIATIONS.G. DETAILS MAY BE EXPLODED (I.E. MATERIALS SEPARATED FOR CLARITY) TO

SHOW DESIGN INTENT.H. SEE SHEET A-101 FOR PARTITION TYPES.I. DIMENSIONS SHOWN ARE FINISH FACE TO FINISH FACE, FACE OF CMU OR

FACE OF CONCRETE UNLESS NOTED OTHERWISE.J. INSTALL CONTROL JOINTS IN GYPSUM WALL AND CEILING SYSTEMS PER

SPEC SECTION 09 29 00 AND WHERE INDICATED IN GA-216, PARAGRAPHS 4.7.3.1-4.7.4 OR ASTM C840, SYSTEM XIII, PARAGRAPHS 20.3.1-20.3.7

K. ALL DOORS TO BE INSTALLED 4" FROM HINGE SIDE OF WALL (TYPICAL) UNLESS NOTED OR DIMENSIONED OTHERWISE.

L. CEILING HEIGHTS IDENTIFIED ARE MINIMUM AND SHALL BE MAINTAINED UNLESS OTHERWISE NOTED.

M. CENTER ALL FIXTURES, EQUIPMENT AND ACCESSORIES IN CEILING TILES, UNLESS OTHERWISE NOTED.

N. CONTRACTOR SHALL PREPARE ALL WALLS AND PARTITIONS AS RECOMMENDED BY THE FINISH MANUFACTURER TO RECEIVE THE FINISHES SPECIFIED.

141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:43:3

3 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

GE

NE

RA

L I

NF

OR

MA

TIO

N

A-001

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

A-0

01,

GE

NE

RA

L IN

FO

RM

AT

ION

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

GENERAL NOTES:CODE DATA:DRAWING ABBREVIATIONS

SUMMARY OF WORK

WORK INLCUDES MODIFICATIONS AND UPGRADES TO THE EXISTING COMMERCIAL KITCHEN AT FIVE RIVERS METROPARKS – ADVENTURE CENTRAL. MODIFICATIONS AND UPGRADES INCLUDE APPROXIMATELY 380 SF OF RENOVATED KITCHEN SPACE, 285 SF OF KITCHEN ADDITION, AND 270 SF OF OUTDOOR STORAGE ADDITION. NEW SPACES INCLUDE KITCHEN, JANITOR’S CLOSET, AND DRY STORAGE.

CHAPTER 1 – ADMINISTRATION

101.2: THE PROVISIONS OF THE OHIO BUILDING CODE, THE OHIO MECHANICAL CODE, AND THE OHIO PLUMBING CODE SHALL APPLY TO THE CONSTRUCTION, ALTERATION, MOVEMENT, ENLARGEMENT, REPLACEMENT, REPAIR, EQUIPMENT, USE AND OCCUPANCY, LOCATION, MAINTENANCE, REMOVAL AND DEMOLITION OF EVERY BUILDING OR STRUCTURE OR ANY APPURTENANCES CONNECTED OR ATTACHED TO SUCH BUILDINGS OR STRUCTURES.

CHAPTER 3 – USE AND OCCUPANCY

SECTION 302: ASSEMBLY GROUP A-3, BUSINESS GROUP B, AND EDUCATIONAL GROUP E

CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS

EXISTING BUILDING IS SPRINKLERED, TYPE 5B CONSTRUCTION.

BUILDING CONTAINS NONSEPARATED OCCUPANCIES (508.3)

508.3.2: THE ALLOWABLE BUILDING AREA AND HEIGHT OF THE BUILDING OR PORTION THEREOF SHALL BE BASED ON THE MOST RESTRICTIVE ALLOWANCES FOR THE OCCUPANCY GROUPS UNDER CONSIDERATION FOR THE TYPE OF CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION 503.1.

508.3.3: NO SEPARATION IS REQUIRED BETWEEN NONSEPARATED OCCUPANCIES.

TABLE 504.3: ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE (A-3) – 60 FEET

TABLE 504.4: ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (A-3) – 2

506.2: ALLOWABLE AREA DETERMINATION (A-3) – 24,000 SF

CHAPTER 6 – TYPES OF CONSTRUCTION

TABLE 601: FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS – TYPE 5B

PRIMARY STRUCTURAL FRAME: 0 HOURSBEARING WALLS – EXTERIOR/INTERIOR: 0 HOURSNONBEARING WALLS AND PARTITIONS – EXTERIOR/INTERIOR: 0 HOURSROOF CONSTRUCTION AND SECONDARY MEMBERS: 0 HOURS

CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES

708.1: CORRIDOR WALLS ARE NOT REQUIRED TO BE RATED (1020.1, EXCEPTION 4).

CHAPTER 9 – FIRE PROTECTION SYSTEMS

903.2.1: THE BUILDING SHALL BE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM.

906.1, EXCEPTION 1.1: PORTABLE FIRE EXTINGUISHERS ARE NOT REQUIRED.

907.2.1: THE BUILDING SHALL BE EQUIPPED THROUGHOUT WITH FIRE ALARM AND DETECTION SYSTEMS.

SECTION 10 – MEANS OF EGRESS

TABLE 1020.2: MINIMUM CORRIDOR WIDTH – 36 INCHES

1020.4: DEAD END CORRIDORS – NOT APPLICABLE

1020.1, EXCEPTION 4: A FIRE-RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS IN AN OCCUPANCY IN GROUP B THAT IS A SPACE REQUIRING ONLY A SINGLE MEANS OF EGRESS COMPLYING WITH SECTION 1006.2.

CHAPTER 11 – ACCESSIBILITY

1101.2: BUILDINGS AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THIS CODE AND ICC A117.1 AS AMENDED IN SECTION 1112 OF THIS CHAPTER.

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

06-28-19

Page 3: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DEMO EXISTING MASONRY WALL FOR NEW OVERHEAD COILING COUNTER DOOR AND HOLLOW METAL DOOR AND FRAME

DEMO EXISTING WALL AND DOOR

DEMO EXISTING CEILING, FLOORING, FINISHES, FIXTURES, EQUIPMENT, ETC. AND PREPARE FOR NEW CONSTRUCTION INDICATED

DEMO EXISTING FINISHES, FIXTURES, EQUIPMENT, ETC. AND PREPARE FOR NEW CONSTRUCTION INDICATED

SAWCUT

EXISTING CONCRETE SLAB TO REMAIN - SAWCUT EDGE AT BUILDING ADDITION

DEMO EXISTING CONCRETE SLAB

DEMO EXISTING HVAC UNITS -SEE MECHANICAL

EXISTING CONCRETE SLAB TO REMAIN

APPROXIMATE LOCATION OF GREASE INTERCEPTOR COVER TO REMAIN

8"8"

141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:44:0

9 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

DE

MO

LIT

ION

PLA

N

AD101

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

AD

101,

DE

MO

LIT

ION

PLA

N

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

N

PLAN NORTH

SCALE: 1/4" = 1'-0"AD101

1 DEMOLITION PLAN

KEY PLAN

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

06-28-19

Page 4: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

G

D1

D

DE

1H

1

C

DRY FOOD

STORAGE

132

LAUNDRY /

JANITOR

127

KITCHEN

129

CORRIDOR

126

OUTDOOR

STORAGE

131

7A-201

5A-201

6A-201

11

'-6

"3

'-0

"1

1'-6

"

12'-0"

129.3

130

127

129.1

APPROXIMATE LOCATION OF GREASE INTERCEPTOR COVER TO REMAIN

12

'-1

0 1

/2"

ALIGN

2A-201

3A-201

WORK ROOM

118

AGENT

128

INTERNS

119

MAINT OFF

120

AGENT

125

CORRIDOR

121

MECHANICAL

124

EQUIP.

124A

VOLUNTEERS OFFICE

122

COATS

123

NEW 4" CONCRETE SLAB

A-131

3

A-131

4

A2

A1

A1

ALIG

N

ALIGN

A1ALIGN

A

A1

A2

SEE SHEETS Q-101 AND Q-102 FOR KITCHEN EQUIPMENT PLANS AND DETAILS

129.2

12'-0"

4'-0

"

GREAT ROOM

130

10

'-6

3/8

"

NEW 4" CONCRETE SLAB TO MATCH EXISTING

MOP SINK SEE PLUMBING

EXISTING CONCRETE SLAB TO REMAIN

3A-601

A-601

4

9A-601

10

'-10

"

+/-16'-6 1/4"

1A-201

10A-601

A3A-101

3

131

FRAMING PLAN

A4

10

'-8

"

14'-8"

LEGEND:

ACT ACOUSTIC CEILING TILEC CONCRETECMU CONCRETE MASONRY UNITETR EXISTING TO REMAINEXP EXPOSED TO STRUCTUREFRP FIBER REINFORCED PANELPT PAINTRB RUBBER BASEQT QUARRY TILEQTB QUARRY TILE BASEVCT VINYL COMPOSITION TILE

BASE AS SCHEDULED

CAULK & SEAL (TYP.)

SCHED. CLG.

1/2" FIRECODE GWB

2x4 STUDS @ 16" O.C.

A1

BASE AS SCHEDULED

CAULK & SEAL (TYP.)

SCHED. CLG.

1/2" GWB

2X6 STUDS @ 16" O.C.

A2

BASE AS SCHEDULED

CAULK & SEAL (TYP.)

SCHED. CLG.

1/2" GWB

2x4 STUDS @ 16" O.C.

A3

EXISTING MASONRY WALL

BASE AS SCHEDULED

CAULK & SEAL (TYP.)

SCHED. CLG.

1/2" GWB

2x4 STUDS @ 16" O.C.

A4

EXISTING MASONRY WALL

8" CMU - PAINTED

SEE DETAIL FOR NEW HEADER IN EXISTING MASONRY WALL

/5 A-601

9A-601

MIN. BRG

8"

L6X4X3/8

L6X4X3/8

MIN. BRG

8"

NOTES:

1. PATCH FINISHES WHERE DISTURBED BY NEW CONSTRUCTION.

2. PROVIDE 4'-0"x12'-0" VCT AT KITCHEN SERVING COUNTER AND DOOR.

3. PAINT ALL EXPOSED CMU. 141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:43:3

3 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

FIR

ST

FL

OO

R P

LA

N

A-101

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

A-1

01,

FIR

ST

FLO

OR

PLA

N

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

N

PLAN NORTH

SCALE: 1/4" = 1'-0"A-101

1 FLOOR PLAN

KEY PLAN

ROOM SCHEDULE

ROOM

NUMBER ROOM NAME

WALL

FINISH

BASE

FINISH

FLOOR

FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES126 CORRIDOR PT RB C ACT 8'-0"

127 LAUNDRY / JANITOR FRP QTB QT ACT 8'-0"

129 KITCHEN FRP QTB QT ACT 8'-0"

130 GREAT ROOM ETR ETR ETR/VCT ETR 8'-0" 1,2

131 OUTDOOR STORAGE CMU - C EXP EXP 3

132 DRY FOOD STORAGE FRP QTB QT ACT 8'-0"

A-101SCALE: 3/4" = 1'-0"

2 PARTITION TYPES

N

PLAN NORTH

SCALE: 1/4" = 1'-0"A-101

3 FRAMING PLAN

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

06-28-19

Page 5: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

OUTDOOR

STORAGE

131

LAUNDRY /

JANITOR

127KITCHEN

129

DRY FOOD

STORAGE

132

CORRIDOR

126

EXISTING CEILING TO REMAIN

EXISTING CEILING TO REMAIN

7A-201

5A-201

6A-201

2A-201

3A-201

1" / 1'-0"EXISTING ROOF TO REMAIN

TPO ROOFING MEMBRANE

TPO ROOFING MEMBRANE

NEW 6" ALUMINUM BOX GUTTER

NEW 6" ALUMINUM BOX GUTTER

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

1A-201

2"

NEW CMU WALL

1'-0"

EXISTING METAL SIDING

CLOSED CELL COMPRESSIBLE FOAM FILLER

2"

NEW 4"x4" METAL CORNER TRIM

NEW METAL SIDING

CLOSED CELL COMPRESSIBLE FOAM FILLER

EXISTING METAL SIDING

MIN

.

8"

NEW METAL FLASHING

EXTEND NEW TPO MEMBRANE UP EXISTING WALL AND TERMINATE WITH TERMINATION BAR AND SEALANT

TPO ROOFING MEMBRANE

1/2" ROOF COVER BOARD

1/2" PLYWOOD DECKING

2x10 S-P-F, SELECT STRUCTURAL ROOF JOIST @ 24" O.C.

R-38 BATT INSULATION

DOUBLE TOP PLATE

2x6 S-P-F, STUD GRADE OR BETTER @ 16" O.C.

141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:43:3

4 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

RE

FLE

CT

ED

CE

ILIN

G A

ND

RO

OF

PLA

NS

A-131

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

A-1

31,

RE

FLE

CT

ED

CE

ILIN

G A

ND

RO

OF

PLA

NS

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

N

PLAN NORTH

SCALE: 1/4" = 1'-0"A-131

1 REFLECTED CEILING PLAN

KEY PLAN

N

PLAN NORTH

SCALE: 1/8" = 1'-0"A-131

2 ROOF PLAN

A-101SCALE: 3/4" = 1'-0"

3 CMU CORNER DETAIL

A-101SCALE: 3/4" = 1'-0"

4 NEW WALL CORNER DETAIL

A-201SCALE: 1 1/2" = 1'-0"

5 FRAMING DETAIL

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

06-28-19

Page 6: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

NEW ROOF

9'-4"

3A-201

PAINTED CMU WALLNEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

METAL SIDINGNEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

PREFINISHED METAL TRIM

1" / 1'-0"

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

NEW ROOF

9'-4"

PREFINISHED METAL TRIM

METAL SIDING

1" / 1'-0"

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

NEW ROOF

9'-4"

METAL SIDING

FIXED ALUMINUM WINDOW

PREFINISHED METAL TRIM

2A-201

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

PAINTED CMU WALL

PREFINISHED METAL TRIM

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

3A-601

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

RAMP

-1'-6"T/FTG

-2'-0"

NEW ROOF

9'-4"

A-201

4A-131

5

1" / 1'-0"

DOWEL INTO EXISTING FOOTING @ 18" OC

8"

1'-0

"

8"

FIRST FLOOR

0'-0"

NEW ROOF

9'-4"

1 1/2" METAL SIDING

1" RIGID INSULATION

1/2" PLYWOOD SHEATHING

2x6 S-P-F, STUD GRADE OR BETTER @ 16" O.C. W/ TREATED SILL AND DOUBLE TOP PLATE

R-19 BATT INSULATION

1/2" GYPSUM BOARD

NEW 6" ALUMINUM BOX GUTTER

2X10 S-P-F, SELECT STRUCTURAL ROOF JOIST @ 24" OC

1/2" PLYWOOD DECKING

1/2" ROOF COVER BOARD

TPO ROOFING MEMBRANE

CEILING AS SPECIFIED

R-38 BATT INSULATION

CONCRETE FOUNDATION WALL

A-601

7

A-601

8

NEW 4" CONCRETE SLAB

2'-0"

1'-0

"2

'-0

"

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

T/FTG

-2'-0"

NEW ROOF

9'-4"

DOWEL INTO EXISTING FOOTING

@ 18" OC

8" CMU W/ #6@48" OC VERT AND LADDER TYPE JOINT REINFORCEMENT @ 16" OC VERT

10"

8"

NEW 4" CONCRETE SLAB

TPO ROOFING MEMBRANE OVER 1/2" ROOF COVER BOARD OVER 1/2" PLYWOOD DECKING

NEW 6" ALUMINUM BOX GUTTER

1'-0

"

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

NEW ROOF

9'-4"

3A-601

OVERHEAD COILING DOOR

PREFINISHED METAL TRIM

NEW 3"X4" ALUMINUM DOWNSPOUT WITH CONCRETE SPLASH BLOCK

NEW 6" ALUMINUM BOX GUTTER

141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:44:0

8 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

BU

ILD

ING

EL

EV

AT

ION

S

A-201

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

A-2

01,

BU

ILD

ING

ELE

VA

TIO

NS

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

A-101SCALE: 1/4" = 1'-0"

5 NORTH ELEVATION

A-101SCALE: 1/4" = 1'-0"

6 SOUTH ELEVATIONA-101

SCALE: 1/4" = 1'-0"

7 WEST ELEVATION

A-101 SCALE: 1/4" = 1'-0"

2 BUILDING SECTION

A-201SCALE: 1/2" = 1'-0"

4 WALL SECTION

A-101 SCALE: 1/4" = 1'-0"

3 OUTDOOR STORAGE BLDG SECTIONA-101 SCALE: 1/4" = 1'-0"

1 EAST ELEVATION

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

Page 7: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

TYPE "1"HM FRAME

SE

E S

CH

ED

ULE

2"

SEE SCHED.

FFLUSH

OCOVERHEAD COILING

OCCOVERHEAD COILING COUNTER

A

3'-0

"4

'-0

"

3'-0"

8

7

7 SIM.

LEGEND:

ETR EXISTING TO REMAINGALV GALVANIZEDHM HOLLOW METALPT PAINT

2"

GYPSUM BOARD PARTITION - SEE PLANS FOR TYPE

CAULKING AT GYP. BD.

HOLLOW METAL DOOR FRAME

HOLLOW METAL DOOR

1/2" 1/2"

2"

GYPSUM BOARD PARTITION - SEE PLANS FOR TYPE

CAULKING AT GYP. BD.

HOLLOW METAL DOOR FRAME

HOLLOW METAL DOOR

JAMB CLIPS (3 PER JAMB)

1/2" 1/2"

8" CMU BOND BEAM W/ (2) #4 CONT.

8" CMU

PREFINISHED METAL TRIM

1/2" PLYWOOD DECKING

1/2" ROOF COVER BOARD

TPO ROOFING MEMBRANE

2x10 S-P-F, SELECT STRUCTURAL ROOF JOIST @ 24" O.C.

OVERHEAD COILING DOOR

GALVANIZED METAL TRACKS BY DOOR MANUFACTURER

8" CMU

CLOSED CELL COMPRESSIBLE FOAM FILLER

EXISTING METAL SIDING

FIXED ALUMINUM WINDOW

1" RIGID INSULATION

1 1/2" METAL SIDING

1/2" PLYWOOD SHEATHING

JOINT SEALANT

NEW METAL DRIP FLASHING

2x WOOD HEADER

1/2" GWB

FIXED ALUMINUM WINDOW

1" RIGID INSULATION

1 1/2" METAL SIDING

1/2" PLYWOOD SHEATHING

JOINT SEALANT

METAL PAN FLASHING

1/2" GWB

2x6 S-P-F, STUD GRADE OR BETTER @ 16" O.C.

R-19 BATT INSULATION

FIRST FLOOR

0'-0"

RAMP

-1'-6"T/FTG

-2'-0"

NEW ROOF

9'-4"

3'-4"

MIN

.3

'-0

"

A-601

6

A-601

5

EXISTING MASONRY WALL

5/8" THREADED ROD @ 16" OC

1/8" COVER PLATE

1/8 1-12

OVERHEAD COILING COUNTER DOOR

2x4 STUDS @ 16" O.C.

1/2" GWB

1"1"

8" CMU - PAINTED

1 1

/2"

2x4 STUDS @ 16" O.C.

1/2" GWB

PLASTIC LAMINATE COUNTER BY COILING DOOR MANUFACTURER

OVERHEAD COILING COUNTER DOOR

FIRST FLOOR

0'-0"

EXISTING ROOF

13'-0"

T/FTG

-2'-0"

NEW ROOF

9'-4"

9A-601

SET 13 PR HINGES1 EA PASSAGE SET1 EA WALL STOP

HARDWARE SCHEDULE

141 W

est

Centr

al A

ve.

// #

21 /

/ W

inte

r H

aven,

FL 3

3880

Phone:

615.2

54.1

500 /

/ F

ax:

615.2

55.6

572

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e /

Date

:

FILE NO.

File

:D

raw

ing

:

RE

VIS

ION

IN

FO

RM

AT

ION

6/2

8/2

019 2

:44:0

9 P

M

C:\

Users

\TJF

inney\D

ocum

ents

\AD

V C

EN

_A

C_v18_tim

.fin

ney.r

vt

DO

OR

AN

D W

IND

OW

SC

HE

DU

LE

A-601

FIV

E R

IVE

RS

ME

TR

OP

AR

KS

3695800

AD

VE

NT

UR

E C

EN

TR

AL

-K

ITC

HE

NM

OD

IFIC

AT

ION

S &

UP

GR

AD

ES

A-6

01,

DO

OR

AN

D W

IND

OW

SC

HE

DU

LE

22

22

JA

ME

S H

. M

CG

EE

BL

VD

-D

AY

TO

N, O

HIO

FRAME TYPESDOOR LEAF TYPES

DOOR SCHEDULE

DOORNUMBER

LEAF INFORMATION FRAME INFORMATION

HARDWARE

FIRERATING

(MIN) NOTESLEAFQTY WIDTH HEIGHT THICKNESS

LEAFTYPE MATERIAL FINISH

FRAMETYPE MATERIAL FINISH JAMB HEAD

127 1 3'-0" 7'-0" 1 3/4" F HM PT 1 HM PT 2/A-601 1/A-601 1

129.1 1 3'-0" 7'-0" 1 3/4" F HM PT 1 HM PT 2/A-601 1/A-601 1

129.2 1 6'-0" 3'-0" OCC GALV - - GALV - 3/A-601 5/A-601 - FRAME BY OVERHEAD DOOR MANFACTURER

129.3 1 3'-0" 7'-0" 1 3/4" F HM PT 1 HM PT 2/A-601 1/A-601 1

130 1 3'-0" 7'-0" 1 3/4" F HM PT 1 HM PT 2/A-601 1/A-601 1

131 1 8'-0" 8'-0" OC GALV - - GALV - 4/A-601 3/A-601 - FRAME BY OVERHEAD DOOR MANFACTURER

(REFER TO DOOR SCHEDULE FOR SIZES)

WINDOW SCHEDULE

A-601SCALE: 1 1/2" = 1'-0"

1 HM DOOR HEAD AT STUD

A-601SCALE: 1 1/2" = 1'-0"

2 HM DOOR JAMB AT STUD

A-101SCALE: 1 1/2" = 1'-0"

3 OC DOOR HEAD

A-101SCALE: 1 1/2" = 1'-0"

4 OC DOOR JAMB

A-201SCALE: 1 1/2" = 1'-0"

7 WINDOW HEAD DETAIL

A-201SCALE: 1 1/2" = 1'-0"

8 WINDOW SILL DETAIL

A-101 SCALE: 1/2" = 1'-0"

9 SECTION THRU OCC

A-601SCALE: 1 1/2" = 1'-0"

5 OCC HEAD DETAIL

A-601SCALE: 1 1/2" = 1'-0"

6 OCC SILL DETAIL

A-101SCALE: 1/4" = 1'-0"

10 WALL INFILL ELEVATION

RE

V.

DR

CH

KD

AT

E:

DE

SC

RIP

TIO

N:

06-28-19

Page 8: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment
Page 9: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment
Page 10: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment
Page 11: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

GEN

ERAL

INFO

RM

ATIO

N -

PLU

MBI

NG

P-001

CO

SYMBOLS LISTPIPING

EXISTING TO REMAIN

EXISTING TO BE DEMOLISHED

(E)

(D)

DOMESTIC HOT WATER HW

DOMESTIC COLD WATER CW

DOMESTIC HOT WATER RETURN HWR

SANITARY SAN

VENT V

NATURAL GAS G

PIPING (FITTINGS, VALVES, AND MISCELLANEOUS)

DROP

RISE

TEE

CAP

FLOW ARROW

PUMP

BUTTERFLY VALVE

BALL VALVE

CHECK VALVE

BALANCE VALVE

STRAINER

UNION

TEMPERATURE & PRESSURE RELIEF VALVE

THERMOMETER

METER

PIPE SLEEVE

PLUG VALVE

SOLENOID VALVE

GAS PRESSURE REGULATOR

OUTSIDE STEM & YOKE VALVE

REDUCED PRESSURE BACKFLOW PREVENTER

PRESSURE GAUGE WITH STOPCOCK

AQUASTAT

WALL HYDRANT OR HOSE BIBB

CLEANOUT AT FLOOR OR AT GRADE

FLOOR DRAIN

NOTATIONS

CONNECT TO EXISTING

BEGINNING AND/OR END OF DEMOLITION

DOMESTIC WATER RISER

SANITARY STACK

1

P-XXX

A

P-XXX

A

M

S

ABBREVIATIONSNOTE: NOT ALL ABBREVIATIONS MAY BE USED.

(D) EXISTING TO BE DEMOLISHED(E) EXISTING TO REMAINAFF ABOVE FINISHED FLOORAMP AMPERE

APPROX APPROXIMATEARCH ARCHITECTAUTO AUTOMATICBLDG BUILDINGCAP CAPACITYCFH CUBIC FEET PER HOUR

CONN CONNECTION OR CONNECTCONT CONTINUATIONCU FT CUBIC FEETCU IN CUBIC INCH

D DRAINDEPT DEPARTMENTDIA DIAMETER

DWG DRAWINGEQUIP EQUIPMENTEWC ELECTRIC WATER COOLEREXH EXHAUSTEXP EXPANSION

EXIST EXISTING°F DEGREES FAHRENHEITFD FLOOR DRAIN

FIN FL EL FINISHED FLOOR ELEVATIONFT FOOT OR FEETGA GAUGEGAL GALLONSGPH GALLONS PER HOURGPM GALLONS PER MINUTEHP HORSEPOWER

HVAC HEATING, VENTILATING, AND AIR CONDITIONINGHZ HERTZIN INCHES

INV EL INVERT ELEVATIONKW KILOWATTL LAVATORY

MAX MAXIMUMMECH MEHCANICALMFG MANUFACTURERMIN MINIMUMMS MOP SINKN/A NOT APPLICABLENO. NUMBERNTS NOT TO SCALE

PLBG PLUMBINGPRESS PRESSURE

PSI POUNDS PER SQUARE INCHPSIG PSI GUAGERCP RECIRCULATING PUMP

RPBP REDUCED PRESSURE BACKFLOW PREVENTERRPM REVOLUTIONS PER MINUTESHT SHEET

SPEC SPECIFICATIONTEMP TEMPERATURETMV THERMOSTATIC MIXING VALVETYP TYPICALUNO UNLESS NOTED OTHERWISEUR URINALV VOLT/VENT

VB VACUUM BREAKERVTR VENT THRU ROOF

GENERAL NOTES:

1. PROVIDE NEW DOMESTIC WATER, SANITARY WASTE, STORM DRAINAGE,NATURAL GAS FOR THIS BUILDING. PROVIDE ALL NECESSARYCOMPONENTS FOR FULLY OPERATIONAL SYSTEM. INSTALL SYSTEMS INACCORDANCE WITH STATE REQUIREMENTS AND LOCAL AUTHORITYHAVING JURISDICTION.COORDINATE THE LOCATION OF ALL UTILITYCONNECTION POINTS, FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENTWITH OTHER TRADES.

2. ALL FLOOR PENETRATIONS TO BE SEALED WATER TIGHT ANDCOMPLETELY PACKED WITH FIRE STOP MATERIAL BY TRADECONTRACTORS.

3. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOTINTENDED TO SHOW THE EXACT LOCATIONS OF COMPONENTS, NORSHOW ALL SYSTEM COMPONENTS. CONTRACTOR SHALL PROVIDEADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPERINSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TOMAINTAIN PROPER CLEARANCES.

4. DRAWINGS ARE NOT TO BE SCALED. DIMENSIONS SHALL GOVERN.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THEJOB SITE CONCERNING EXISTING AND NEW WORK BEFORE PROCEEDINGWITH EITHER FABRICATION OR INSTALLATION IN MECHANICAL AREASWITH NUMEROUS OBSTRUCTIONS INCLUDING DUCTWORK, EQUIPMENTAND PIPING. THIS WILL REQUIRE ON SITE CUTTING AND VERIFICATION.

5. ANY INFORMATION CONFLICTS BETWEEN THE SPECIFICATIONS ANDDRAWINGS SHALL BE BROUGHT TO THE ENGINEERS'S ATTENTION. THECONTRACTOR(S) SHALL NOT PROCEED WITH ANY WORK, EXCEPT ATTHEIR OWN RISK, UNTIL CLARIFICATIONS OF THE CONFLICTS ARE ISSUEDTO THE CONTRACTOR(S) BY THE ENGINEER.

6. ALL MATERIAL AND LABOR SHALL BE UNDER WARRANTY FOR ONE YEARFROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. ANY NEWDEVICES OR EQUIPMENT FOUND FAULTY SHALL BE REPLACED AS PARTOF THE WARRANTY.

7. A SET OF APPROVED DRAWINGS SHALL BE MAINTAINED ON SITE AND ALLFIELD CHANGES SHALL BE RED LINED ON THE DRAWINGS. CONTRACTORSHALL PREPARE "AS-BUILT" DRAWINGS IN ELECTRONIC (AUTOCAD)FORMAT, REFLECTING ACCURATE FIELD CONDITIONS.

8. ALL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTIONSHALL BE PROVIDED A UL LISTED THROUGH PENETRATION FIRESTOPASSEMBLY. THE RATINGS OF ALL FIRESTOP ASSEMBLIES SHALL BEGREATER THAN OR EQUAL TO THE RATING OF THE PENETRATED BARRIER.

9. CORE DRILL PENETRATIONS IN CONCRETE FLOORS OR WALLS 1-2 INCHESLARGER THAN THE PIPE DIAMETER OF THE PENETRATING PIPE.

10. DUCTWORK, PIPING, MECHANICAL EQUIPMENT AND CEILINGS SHALL NOTBE UTILIZED AS LADDERS, SCAFFOLDING OR WORK PLATFORMS.

11. NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, OR BURNEDWITHOUT THE KNOWLEDGE AND WRITTEN APPROVAL OF THE OWNER.

12. EQUIPMENT, MATERIALS, INSTALLATION WORKMANSHIP, EXAMINATIONAND TESTING SHALL BE IN ACCORDANCE WITH CURRENT PLUMBINGCODE. INSTALL PIPING STRAIGHT AND TRUE TO BEAR EVENLY ONHANGARS AND SUPPORTS. PIPE SHALL NOT INTERFERE WITH OTHEREQUIPMENT AND CONSTRUCTION.

13. CONTRACTOR SHALL BE RESPONSIBLE FOR AVOIDING ALL CONFLICTSWITH LIGHTING FIXTURES, DIFFUSERS, GRILLS, DUCTS, STRUCTURALMEMBERS, MECHANICAL EQUIPMENT AND PIPES.

14. NO FABRICATION OR INSTALLATION IS ALLOWED WITHOUT APPROVEDSHOP DRAWING SUBMITTALS.

15. CONTRACTOR SHALL SUBMIT SYSTEM CATALOG PRODUCT DATA SHEETSOF ALL COMPONENTS PROPOSED FOR USE PRIOR TO INSTALLATION FORAPPROVAL. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL.

16. PIPING SHALL NOT SHARE SUPPORTS WITH OTHER BUILDING SYSTEMS. INMECHANICAL AREAS, PIPING SHALL NOT BE ATTACHED TO THE DUCTWORK. STANCHIONS SHALL BE USED WHERE PIPING IS UNABLE TO BEHUNG FROM ABOVE.

17. PIPING IN AREAS WITH FINISHED CEILINGS SHALL BE INSTALLED ABOVEFINISHED CEILINGS.

18. PIPING SHALL NOT BE INSTALLED PASSING THROUGH ELECTRICAL ROOMSOR OVER ELECTRICAL PANELS / EQUIPMENT WHICH SERVES OTHERAREAS. COORDINATE THE LOCATION OF ALL PIPING WITH ELECTRICALEQUIPMENT AND OTHER TRADES AND ADJUST AS NECESSARY.

19. MAKE REASONABLE AND NECESSARY MODIFICATIONS IN LAYOUTS ANDCOMPONENTS NEEDED TO PREVENT CONFLICTS WITH WORK OF OTHERTRADES AND TO COORDINATE IN ACCORDANCE WITH SPECIFICATIONS.

20. MAINTAIN MAXIMUM HEADROOM AT ALL LOCATIONS. ALL PIPING TO BE ASTIGHT TO THE UNDERSIDE OF DECK AS POSSIBLE. AL EXPOSED PIPINGSHALL BE APPROVED BY ARCHITECT AND SHALL MAINTAIN REQUIREDCLEARANCES.

PLUMBING FIXTURE SCHEDULETAG FIXTURE DESCRIPTION MANUFACTURER MODEL #

L1

LAVATORY: 20-1/2" X 18-1/4", VITREOUS CHINA, WALL HUNG, FRONT OVERFLOW, SELF-DRAINING DECKAREA WITH CONTOURED BACK AND SIDE SPLASH SHIELDS, FAUCET LEDGE, FAUCET HOLES ON 4"CENTERS, CONCEALED ARMS SUPPORT.

AMERICANSTANDARD 0355.012

FAUCET: DECK MOUNTED FAUCET WITH 8" INTEGRAL SPOUT, POLISHED CHROME PLATED FINISH, SOLIDBRASS BODY CONSTRUCTION, 0.5 GPM PRESSURE COMPENSATING AERATOR OUTLET, LEVERHANDLES, SECURED COLOR CODED INDEX BUTTONS, 4” CENTERS. CHICAGO 802-ABCP

TRIM: SUPPLY PIPE WITH LOOSE KEY STOPS. CAST BRASS P-TRAP WITH CLEAN-OUT. DRAIN WITHCHROME PLATED CAST BRASS SOLID TOP, OPEN GRID, P.O. PLUG. CHROME PLATED BRASS 17 GAUGETAILPIECE.

MCGUIRE 165LK, 8902, 149

THEMOSTATIC MIXING VALVE: LEAD-FREE DESIGN, WAX-FILLED THERMOSTAT, ADJUSTABLE SET POINTWITHIN TEMPERATURE RANGE, UNIVERSAL MOUNTING CAPABILITY, INTEGRAL CHECK VALVES ANDSTRAINER, ASSE 1070 COMPLIANT. SET TO 110°F. BRADLEY S59-4000

CARRIER: LAVATORY SUPPORT WITH CONCEALED ARMS, RECTANGULAR STEEL UPRIGHTS WITHWELDED FEET, CAST IRON ADJUSTABLE HEADERS, CONCEALED ARMS, STEEL SLEEVE, ALIGNMENTTRUSS AND MOUNTING FASTENERS. ZURN SERIES Z1200

MS1

MOP SINK: 24"x24", PRECAST TERRAZZO ONE PIECE PRODUCTS ARE MADE OF MARBLE CHIPS CAST INGREY PORTLAND CEMENT. 12" HIGH. SHOULDERS SHALL NOT BE LESS THAN 2" WIDE WITH 1/2" PITCHTOWARD INSIDE. STAINLESS STEEL CAPS ON ALL CURBS. DRAIN BODY MADE OF STAINLESS STEEL CASTINTEGRALLY AND PROVIDE FOR A CAULKED LEAD CONNECTION NOT LESS THAN 1" DEEP TO A 3" PIPE. FIAT TSB100

TRIM: WALL MOUNTED SERVICE SINK FAUCET, POLISHED CHROME PLATED FINISH, SOLID BRASS BODYCONSTRUCTION, ATMOSPHERIC VACUUM BREAKER SPOUT WITH PAIL HOOK AND WALL BRACE, 3/4" MALEGARDEN HOSE THREAD OUTLET, LEVER HANDLES WITH SECURED COLOR CODED INDEX BUTTONS. CHICAGO 897CP

FD1

FLOOR DRAIN: ADJUSTABLE CAST IRON BODY, ROUND NICKEL BRONZE STRAINER. CAULK OUTLET.CONTRACTOR SHALL BUFF STRAINER TO BE SUITABLE FOR BAREFOOT TRAFFIC IN SHOWER AREAS.SURESEAL INLINE FLOOR DRAIN TRAP SEALER MODEL (3") SS3009V OR (4") SS4009V. J.R. SMITH 2005-A

FS1

FLOOR SINK: STAINLESS STEEL TYPE 304, 14 GAUGE FLANGED RECEPTOR BODY WITH SEEPAGECONTROL HOLES, RIBBED NON-TILT LOOSE SET GRATE WITH 1/2-INCH SQUARE HOLES. PERFORATEDSTAINLESS STEEL DOME BOTTOM STRAINER. PROVIDE STAINLESS STEEL HALF GRATE. SURESEAL INLINEFLOOR DRAIN TRAP SEALER MODEL (3") SS3009V OR (4") SS4009V.

J.R. SMITH 3002-12

WH1WALL HYDRANT: FREEZEPROOF FAUCET, BRONZE CASING, HINGED, LOCKING POLISHED BRONZE(NICKEL) BOX AND COVER, SELF-DRAINING VACUUM BREAKER, INTEGRAL BACKFLOW PREVENTER, 3/4"SIZE. LENGTH AS REQUIRED.

WOODFORD 67

WB1WASHING MACHINE: 1/2" COMBINATION MPT BRASS SWEAT CONNECTION, 1/2" HOSE END VALVES, 1-1/2"DRAIN PIPE AND OVERFLOW GUARD. GUY GRAY T200TPPVC

WB2ICE MACHINE: 20 GAUGE RECESSED REFRIGERATOR BOX WITH 18 GAUGE FACEPLATE. PAINT OT MATCHWALL. VALVE SHALL BE 1/2" SWEAT CONNECTION AND 1/4" O.D. COMPRESSION OUTLET. GUY GRAY MIB1HA

WB3 WALL BOX: 3/4" COMBINATION MPT BRASS SWEAT CONNECTION, 3/4" HOSE END VALVES, 1-1/2" DRAINPIPE AND OVERFLOW GUARD. GUY GRAY MWB3

PLUMBING FIXTURE ROUGH-IN SCHEDULEFIXTURE WASTE TRAP VENT COLD HOT

L1 1-1/2" 1-1/4"x1-1/2" 1-1/2" 1/2" 1/2"

MS1 3" 3" 1-1/2" 1/2" 1/2"

FD1 3" 3" 1/2" NA NA

FS1 4" 4" 2" NA NA

WH1 NA NA NA 3/4" NA

WB1 3" 2" 1-1/2" 1/2" 1/2"

WB2 NA NA NA 1/2" NA

WB3 1-1/2" 1-1/2" 1-1/2" NA 3/4"

DOMESTIC WATER HEATER SCHEDULETAG

ELECTRIC CFHINPUT

MINIMUMEFFICIENCY

GALLONS OFSTORAGE

RECOVERYAT 100°F

EXHAUSTSIZE

INTAKESIZE MANUFACTURER MODEL # NOTES

VOLT PHASE

GWH1 120 1 199 97% 100 235 4" 4" A.O. SMITH BTH-199 SET TANK TEMPERATURE TO 140°F

EXPANSION TANK SCHEDULETAG

TOTAL VOLUME(GALLONS) INLET MANUFACTURER MODEL # NOTES

ET1 4.4 3/4" AMTROL ST-12 CHARGE TO INCOMING WATER PRESSURE AFTER REDUCED PRESSUREBACKFLOW PREVENTER

PUMP SCHEDULETAG

ELECTRICGPM FEET OF

HEAD MANUFACTURER MODEL # NOTESVOLT PHASE HP

RCP1 120 1 1/25 5 10 GRUNDFOS UP15-42FR

THERMOSTATIC MIXING VALVE SCHEDULETAG INLET SIZE OUTLET

SIZE MANUFACTURER MODEL # NOTES

TMV1 1/2" 1/2" BRADLEY S59-4000 SET DISCHARGE TEMPERATURE TO 110°F

Page 12: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DN

01/4"=1'-0" 2' 4' 8'1 UNDERSLAB FLOOR PLAN - PLUMBING - DEMOLITION

(E)SAN

(E)SAN

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

UNDE

RSLA

B FL

OO

R PL

AN -

PLUM

BING

- DE

MO

LITI

ON

PD100

Page 13: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DN

CODED NOTES:

1. EXISTING SINK, FAUCET, TRIM AND ASSOCIATED PIPING TO BEREMOVED.

2. EXISTING GAS-FIRED WATER HEATER TO BE REMOVED.EXISTING GAS, HOT AND COLD WATER PIPING TO REMAIN.

3. 3- COMP SINK, FAUCET, TRIM AND ASSOCIATED PIPING TO BEREMOVED. EXISTING HOT AND COLD WATER PIPING TO REMAIN.EXISTING SANITARY TO BE REMOVED TO BELOW SLAB ANDCAPPED.

4. EXISTING SINK AND ASSOCIATED PIPING TO REMAIN.

5. EXISTING LAVATORY, FAUCET, TRIM AND ASSOCIATED PIPING TOBE REMOVED. EXISTING SANITARY TO BE REMOVED TO BELOWSLAB AND CAPPED.

6. EXISTING GAS PIPING TO HVAC EQUIPMENT TO BE REMOVED.

7. DISCONNECT EXISTING GAS LINE FROM EXISTING HVACEQUIPMENT BEING REMOVED. PROVIDE TEMPORARY CAP.

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - PLUMBING - DEMOLITION

(E)G

(E)V

(E)CW

1

4

3

5

6

2

7

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

PLU

MBI

NG

- D

EMO

LITI

ON

PD101

Page 14: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DRY FOODSTORAGE

132

LAUNDRY /JANITOR

127

KITCHEN129

CORRIDOR126

OUTDOORSTORAGE

131

WORKROOM

118

AGENT128

INTERNS119

MAINT OFF120

AGENT125

CORRIDOR121

MECHANICAL124

EQUIP.124A

VOLUNTEERSOFFICE

122

COATS123

GREATROOM

130

01/4"=1'-0" 2' 4' 8'1 UNDERSLAB FLOOR PLAN - PLUMBING

(E)SAN

(E)SAN

SAN

CO

CO

CO

FD1

FS1

FS1

CO

3"

3"

4"

4"

AP-100 STACK

NONE2 DIAGRAM - STACK "A"

FS1

FD1

CO

CO

FS1

WB1

CO

MS1

WB3

M20

2"

3"

3"

3"

3"1-1/2"

1-1/2"

2"1-1/2"

2"

1-1/2"

L1

2"3"

4"

3"

1-1/2"

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

UN

DER

SLAB

FLO

OR

PLA

N -

PLU

MBI

NG

P-100

Page 15: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DRY FOODSTORAGE

132

LAUNDRY /JANITOR

127

KITCHEN129

CORRIDOR126

OUTDOORSTORAGE

131

WORKROOM

118

AGENT128

INTERNS119

MAINT OFF120

AGENT125

CORRIDOR121

MECHANICAL124

EQUIP.124A

VOLUNTEERSOFFICE

122

COATS123

GREATROOM

130

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - PLUMBING

(E)G

(E)V

(E)CW

MS1

WB1

M7

WB2

WB3

M20

M9

M10

M3

M18

GWH1

L1

1

CODED NOTES:

1. PROVIDE THERMOSTATIC MIXING VALVE (TMV1) TO SERVEEXISTING SINK.

2. INSTALL EMERGENCY GAS SHUT-OFF VALVE FURNISHED WITHHOOD.

3. 1-1/2" G TO TO MAKEUP AIR UNIT ON ROOF. PROVIDE SHUT-OFFVALVE AND DIRT LEG. MAKE FINAL CONNECTION. (200 CFH)

4. 3/4" G TO CONVECTION OVEN (90 CFH).

5. 3/4" G TO RANGE (270 CFH).

6. EXISTING GREASE INTERCEPTOR TO BE CLEANED.

7. 1" G UP TO ROOFTOP UNIT. PROVIDE SHUT-OFF VALVE AND DIRTLEG. MAKE FINAL CONNECTION. (60 CFH)

8. CONNECT EXISTING GAS LINE TO NEW GAS-FIRE WATERHEATER. (199 CFH)

9. CONNECT EXISTING GAS LINE TO NEW HVAC EQUIPMENT.

2

2"

V

G

1"

3/4"

2"

1/2"

1/2"

1/2"3/4"

1/2"

1/2"

1/2"

3/4"

2"1"

3/4"

3/4"1/2"

2"

3/4"

G7

3

8

4

56

1"

2"

2"

1-1/2"

NTS2 DETAIL - GAS-FIRED WATER HEATER

THERMOMETER.RANGE 30°-180°F

TMV1

GWH1

ET1 RCP1

A

TEMPERATURE PRESSURE RELIEFVALVE WITH DISCHARGE PIPE DOWNTO 6" ABOVE FLOOR

3/4" DRAIN FURNISHEDWITH WATER HEATER

4" HOUSEKEEPING PAD

GAS LINE TO WATER HEATER

EXTERIOR WALL

4" PVC EXHAUST

4" PVC INTAKE

BIRD SCREEN

9

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

PLU

MBI

NG

P-101

Page 16: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

GENERAL NOTES:

A. THESE NOTES APPLY TO ALL DIVISION 23 DRAWINGS.

B. ALL HVAC WORK SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL CODES.

C. CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, FEES, AND PERMITS FOR A COMPLETEINSTALLATION. CONTRACTOR SHALL COMPLY WITH ALL GENERAL CONDITIONS LISTED ON THEARCHITECTURAL DRAWINGS.

D. IN CASE OF DIFFERENCE BETWEEN BUILDING CODES, SPECIFICATIONS, INDUSTRY STANDARDS, UTILITYCOMPANY REGULATIONS, FIRE INSURANCE CARRIER'S REQUIREMENTS, AND CONTRACT DOCUMENTS, THEMOST STRINGENT SHALL GOVERN. PROMPTLY NOTIFY THE ENGINEER IN WRITING OF ANY SUCHDIFFERENCE.

E. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE FUNCTIONALITY OF THE HVAC SYSTEMINCLUDING ELECTRICAL AND CONTROL ITEMS ASSOCIATED WITH THE MECHANICAL EQUIPMENT.

F. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION OFMECHANICAL, PLUMBING, AND EQUIPMENT. DRAWINGS ARE BASED ON "AS-BUILT" DRAWINGS AND LIMITEDFIELD OBSERVATIONS. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, SIZE AND LOCATION OFEQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE.

G. CONTRACTOR SHALL VERIFY ALL CONDITIONS PRIOR TO SUBMITTING BIDS. PRIOR TO BID CONTRACTORSHALL ADVISE ENGINEER IN WRITING OF ANY CONDITIONS THAT SWAYS FROM CONTRACT DOCUMENTS.

H. IN THE EVENT OF A CONFLICT BETWEEN THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND THEACTUAL FIELD CONDITIONS THE CONTRACTOR SHALL ADVISE ENGINEER IN WRITING PRIOR TOPROCEEDING WITH WORK. THE CONTRACTOR SHALL BEAR ALL COSTS ASSOCIATED WITH RESTOCKING,RELOCATING OF EQUIPMENT, SYSTEMS, PIPING, ETC. FROM FAILURE TO PROPERLY COORDINATEINSTALLATION AND NOT ADVISING IN WRITING OF CONFLICT PRIOR TO PURCHASE AND/OR INSTALLATION.

I. NOT ALL EXISTING SYSTEMS ARE SHOWN TO AID DRAWING INTERPRETATION AND CLARITY.

J. CONTRACTOR IS TO MAINTAIN RECORDED "AS-BUILT" INFORMATION ON ALL EXISTING SERVICESUNCOVERED DURING CONSTRUCTION AND ALL NEW SERVICES BEING INSTALLED. "AS-BUILT" DRAWINGSSHALL BE MAINTAINED IN THE FIELD. THE "AS-BUILTS" SHALL CAPTURE INFORMATION ON A CLEARLYMARKED IN COLOR PRINTED COPY OF CONTRACT DRAWING. RECORDED INFORMATION SHALL INCLUDEROUTING AND INVERT ELEVATIONS. AT THE COMPLETION OF THE CONTRACT, THE CONTRACTOR SHALLPROVIDE ELECTRONIC (PDF FORMAT) OF RECORDED "AS-BUILT" INFORMATION TO THE ENGINEER.

K. THE CONTRACTOR SHALL BE RESPONSIBLE FOR START-UP OF ALL EQUIPMENT AND SYSTEMS INSTALLED,MODIFIED, OR REVISED BY THIS WORK PER MANUFACTURER'S REQUIREMENTS AND/OR CONTRACTDOCUMENTS.

L. AT THE END OF CONSTRUCTION, CONTRACTOR SHALL PERFORM A COMPLETE AIR SYSTEM FLOWBALANCE FOR ALL EQUIPMENT AND SYSTEMS SHOWN, SCHEDULED OR OTHERWISE IDENTIFIED.CONTRACTOR SHALL INCLUDE TIME IN CONSTRUCTION SCHEDULE TO FULLY TEST AND BALANCESYSTEMS PRIOR TO OCCUPANCY TO ASSURE ADJUSTMENTS CAN BE MADE TO MITIGATE COMFORT ISSUESFOR OCCUPANTS POST CONSTRUCTION.

M. UPON COMPLETION OF HVAC SYSTEMS, THE MECHANICAL CONTRACTOR SHALL INSTRUCT THE OWNER INTHE COMPLETE OPERATION OF THE SYSTEMS.

N. PRIOR TO AND DURING CONSTRUCTION, CONTRACTOR SHALL FULLY PROTECT THE AIR HANDLING ANDDUCTWORK SYSTEMS. CONTRACTOR SHALL PROTECT EACH RETURN AIR GRILLE OPENING AND RETURNAIR DUCT WITH MINIMUM MERV 8 FILTER MEDIA. AIR HANDLING EQUIPMENT AND DUCTS COVERED WITHDRYWALL/CONSTRUCTION DUST SHALL BE CLEANED AT CONTRACTOR EXPENSE.

O. THE CONTRACTOR SHALL ENSURE THAT ALL MECHANICAL EQUIPMENT, DUCTWORK, PIPING, VALVES, ANDACCESS LOCATIONS HAVE CLEARANCES IN ACCORDANCE TO THE DRAWINGS AND THE MANUFACTURER'SREQUIREMENTS FOR FULL ACCESSIBILITY AND OPERATION OF MECHANICAL SYSTEMS.

P. THE CONTRACTOR SHALL PROVIDE ACCESS PANELS, IN WALLS OR CEILING, OR ACCESS DOORS, INDUCTWORK, AS INDICATED OR REQUIRED FOR ACCESS TO CONCEALED MECHANICAL EQUIPMENT ORDEVICES.

Q. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION AND SHALL REPAIR ADJACENT EXISTING AND/ORNEW SURFACES, AREAS, AND PROPERTY THAT MAY BE DAMAGED AS A RESULT OF DEMOLITION AND/ORNEW WORK.

R. COORDINATE THE LOCATION OF ALL UTILITY CONNECTION POINTS FOR EQUIPMENT WITH OTHER TRADES.COORDINATION INCLUDES ALLOWING PROPER CLEARANCE FOR ELECTRICAL DEVICES FURNISHED WITHEQUIPMENT INCLUDING CONTROLS, DISCONNECTS, CONTROL PANELS, ETC.

S. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING DEVICES,INCLUDING CEILING MOUNTED FANS.

T. COORDINATE CLOSELY WITH OTHER TRADES IN LOCATING AND INSTALLING ALL SYSTEMS ABOVESUSPENDED CEILINGS. SPECIFICALLY, COORDINATE LAYOUT WITH ELECTRICAL AND PLUMBINGCONTRACTORS TO ALLOW SUFFICIENT ROOM FOR RECESSED LIGHT FIXTURES, FIRE SPRINKLER, ANDPLUMBING VENTS WHERE APPLICABLE.

U. ANNULAR SPACE OF PIPE, CONDUIT, DUCT, AND OTHER SIMILAR PENETRATIONS OF FIRE RATEDASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION, PENETRATIONS THRU 0-HOUR RATED FLOORS SHALLALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO FIRESTOPPINGSPECIFICATION. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT, AND FIRE RATINGSOF FLOORS, WALLS, PARTITIONS, AND OTHER BUILDING ELEMENTS.

V. THE CONTRACTOR SHALL PROVIDE ALL CUTTING, PATCHING, FINISHING, AND PENETRATIONS REQUIREDBY THE INSTALLATIONS. ALL FLOOR PENETRATIONS SHALL BE PATCHED AND SEALED TO BEWATERTIGHT. PROVIDE CHROME ESCUTCHEON FOR EXPOSED PIPING PENETRATIONS. CUTTING OFBUILDING CONSTRUCTION MATERIALS SHALL CONFORM TO THE CHARACTERISTICS OF THE PARTICULARMATERIAL INVOLVED AND SHALL NOT CREATE ANY STRUCTURAL WEAKNESS OR UNSIGHTLYAPPEARANCE. REFINISH ANY SURFACE DISTURBED UNDER THIS WORK TO MATCH EXISTING, EXCEPTWHERE REFINISHING OF THAT SURFACE IS INCLUDED UNDER THE GENERAL TRADES CONTRACT.

W. CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT AND SCHEDULE ANY DISRUPTION, DEMOLITION,OR SHUTDOWN OF UTILITIES OR SYSTEMS TO MINIMIZE INTERRUPTION OF SERVICE AND AVOIDINTERFERENCE WITH NORMAL FUNCTION OF THE BUILDING AND/OR SURROUNDING WORK AREA.DISRUPTIONS INCLUDE LOSS OF HEATING, COOLING, OUTDOOR AIR, AND/OR EXHAUST SYSTEMS.CONTRACTOR SHALL NOTIFY ARCHITECT A MINIMUM OF 14 DAYS PRIOR TO SHUTDOWN.

X. PREFERRED LOCATIONS FOR ROOM TEMPERATURE THERMOSTATS ARE SHOWN ON THE PLANS.COORDINATE LOCATION OF THERMOSTATS AND OTHER WALL MOUNTED DEVICES WITH FURNITURE, WALLFRAMING, ELECTRICAL OUTLETS AND DEVICES, AND TECHNOLOGY OUTLETS AND DEVICES PRIOR TOROUGH-IN. PROVIDE THERMOSTATS WITH ROOM TEMPERATURE INDICATOR AND WITH SET POINTADJUSTMENT.

Y. ALL ROOF AND DECK PENETRATIONS SHALL BE COMPLETED BY THE GENERAL TRADES CONTRACTOR.COORDINATE EXACT SIZE AND LOCATION WITH ARCHITECT AND STRUCTURAL ENGINEER. COORDINATESCOPE OF WORK WITH GENERAL CONTRACTOR PRIOR TO BIDDING.

Z. COORDINATE EXACT LOCATION OF DIFFUSERS, GRILLES AND REGISTERS WITH AREA SMOKE DETECTORS,LIGHTS, AND ELECTRICAL DEVICES. AIR DEVICES SHALL NOT BE CLOSER THAN 3 FEET FROM AN AREASMOKE DETECTOR.

AA. BRANCH DUCT TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED OTHERWISE.FLEXIBLE DUCT CONNECTION TO THE DIFFUSER SHALL BE NO MORE THAN 5 FEET IN LENGTH FLEXIBLEDUCT SHALL NOT BE USED FOR ELBOW TO DIFFUSER WITH A FLEXFLOW SUPPORT ELBOW.

AB. PROVIDE VOLUME DAMPERS AS SHOWN ON THE DRAWINGS, AS REQUIRED BY THE SPECIFICATIONS, ANDSHOWN IN TYPICAL DETAILS. LOCATE VOLUME DAMPERS IN ACCESSIBLE LOCATIONS. A VOLUME DAMPERSHALL BE PROVIDED FOR EACH DIFFUSER AND GRILLE IN ORDER TO BALANCE EACH AIR DEVICEINDEPENDENTLY PER SPECIFIED CFM STATED ON DRAWINGS.

AC. DUCTWORK DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE CLEAR, UNLESS NOTED OTHERWISE.

AD. PROVIDE STRAIGHT INLET AND OUTLET DUCTS PER THE LENGTH THE EQUIPMENT MANUFACTURERRECOMMENDS. FAN INLETS SHALL BE MINIMUM 3 DUCT DIAMETERS OF STRAIGHT DUCT. INSTALL ANDSUPPORT MECHANICAL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE FLEXIBLECONNECTIONS AND VIBRATION ISOLATION FOR VIBRATING EQUIPMENT UNLESS NOTED OTHERWISE.

AE. INSTALL AIRFOIL TURNING VANES IN ALL 90 DEGREE ELBOWS EXCEPT TRANSFER DUCTS AND OPENRETURN AIR BOOTS.

AF. CONTRACTOR SHALL COMPLY WITH SMACNA "HVAC DUCT CONSTRUCTION AND STANDARDS" AND OTHERAPPLICABLE STANDARDS INCLUDED IN THE SPECIFICATIONS FOR THE CONSTRUCTION AND SUPPORT OFDUCTWORK, UNLESS OTHERWISE NOTED

AG. CHANGES IN HVAC DUCT AND PIPE ELEVATIONS SHALL BE PROVIDED AND BE COORDINATED WITH OTHERSYSTEMS INCLUDING, BUT NOT LIMITED, TO PLUMBING, FIRE PROTECTION, ELECTRICAL, AND BUILDINGELEMENTS SYSTEMS. OFFSET DUCTS INTO JOIST SPACE FOR WHERE SPACE ABOVE CEILING IS NOTSUFFICIENT FOR DUCTS TO CROSS OTHER DUCTS OR WORK OF OTHER CONTRACTORS.

AH. DUCTWORK AND PIPING ON DRAWINGS DOES NOT INDICATE ALL REQUIRED OFFSETS AND FITTINGS.INCLUDE THESE OFFSETS AND FITTINGS TO COORDINATE WITH OTHER CONTRACTORS.

AI. SECURELY FASTEN ALL PIPING AND DUCTWORK WITHIN STRUCTURES TO THE BUILDING CONSTRUCTIONBY MEANS OF HANGERS, SUPPORTS, GUIDES, ANCHORS, AND SWAY BRACES TO MAINTAIN PIPE ANDDUCTWORK ALIGNMENT, TO PREVENT SAGGING, AND TO PREVENT NOISE AND EXCESSIVE STRAIN ONPIPING AND DUCTWORK DUE TO MOVEMENT UNDER OPERATING CONDITIONS. SUPPORTS FOR ALL PIPINGAND DUCTWORK SHALL BE IN ACCORDANCE WITH LATEST ANSI AND SMACNA STANDARDS.

AJ. CONTRACTOR SHALL PROTECT THE PIPING AND DUCTWORK TO PREVENT ENTRY OF DIRT AND ANY OTHERFOREIGN MATERIAL DURING THE INSTALLATION.

AK. PROVIDE FLEXIBLE CONNECTIONS FOR ALL VIBRATING EQUIPMENT.

AL. DEMOLITION OF ANY ITEM SHALL INCLUDE ALL ASSOCIATED ITEMS, THIS INCLUDES, BUT IS NOT LIMITEDTO: SUPPORTS, HANGERS, PADS, FASTENERS, INSERTS, SLEEVES, STRAPS, ATTACHMENTS, LEVELERS,AND ALL OTHER ITEMS FOR A COMPLETE DEMOLITION OF THE ITEM.

AM. ALL EQUIPMENT TO BE REMOVED SHALL BE DISPOSED BY THE CONTRACTOR IN ACCORDANCE WITHFEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS.

AN. ALL EQUIPMENT TO BE REUSED OR RETURNED TO THE OWNER SHALL BE REMOVED SO AS TO NOTDAMAGE THE EQUIPMENT, MATERIAL OR AFFECT ITS REUSE. IF ANY EQUIPMENT OR MATERIAL ISDAMAGED BY THE CONTRACTOR, IT SHALL BE REPLACED BY THE CONTRACTOR, WITH NO EXPENSE TOTHE OWNER.

DRAWING INDEXDWG NO. SHEET TITLE

M-001 GENERAL INFORMATION - MECHANICAL

MD101 FIRST FLOOR PLAN - MECHANICAL -DEMOLITION

M-101 FIRST FLOOR PLAN - MECHANICALM-501 DETAILS - MECHANICALM-502 DETAILS - MECHANICALM-601 SCHEDULES - MECHANICAL

SYMBOLS LIST

COOLING COIL CONDENSATE CREFRIGERANT SUCTION RSREFRIGERANT LIQUID RL

PIPING (FITTINGS, VALVES, AND MISCELLANEOUS)DROPRISETEECAPREDUCERFLOW ARROW

DUCTWORK

DOUBLE LINE FLEX DUCT

SINGLE LINE FLEX DUCT

ACCESS DOOR

GRILLE/REGISTER

VOLUME DAMPER

FIRE DAMPER WITH ACCESS DOOR

SMOKE DAMPER WITH ACCESS DOOR

DIFFUSER

AIR FLOW ARROW

CONNECT TO EXISTING

OR

NOTE: NOT ALL SYMBOLS MAY BE USED.

FD

SD

CD

T

H

S

90 DEGREE FITTING(WITH TURNING VANES)

THERMOSTAT(MOUNT 48" AFF TO CENTER UNO)

MISCELLANEOUS SENSOR

HUMIDISTAT(MOUNT 48" AFF TO CENTER UNO)

ORSUPPLY/O.A. DUCTRISE (SINGLE LINE)SUPPLY/O.A. DUCTRISE (DOUBLE LINE)

ORSUPPLY/O.A. DUCTDROP (SINGLE LINE)SUPPLY/O.A. DUCTDROP (DOUBLE LINE) OR

RETURN/EXHAUST/RELIEFDUCT RISE (SINGLE LINE)RETURN/EXHAUST/RELIEFDUCT RISE (DOUBLE LINE)

RETURN/EXHAUST/RELIEFDUCT DROP (SINGLE LINE)RETURN/EXHAUST/RELIEFDUCT DROP (DOUBLE LINE)

OR

OR

OR

OR

FLAT OVAL(DROP OR RISE)

OR

OR

WITHOUT FLEX WITH FLEX

SIDEWALLGRILLE/REGISTER/DIFFUSER

WITHOUT FLEX WITH FLEX

OR

OR

EXISTING WORK (VISIBLE)

FUTUREEXISTING TO BE DEMOLISHED

LINE STYLES

PIPING

NEW WORK (VISIBLE)

BACKDRAFT DAMPERBD

NEW WORK (HIDDEN)

EXISTING WORK (HIDDEN)

COMB. FIRE/SMOKE DAMPERWITH ACCESS DOOR

ABBREVIATIONSNOTE: NOT ALL ABBREVIATIONS MAY BE USED.

(D) EXISTING TO BE DEMOLISHED(E) EXISTING TO REMAIN(R) EXISTING TO BE RELOCATEDAFF ABOVE FINISHED FLOORA/E ARCHITECT/ENGINEERBAS BUILDING AUTOMATION SYSTEMCO CLEAN OUTDIA DIAMETERDN DOWNEA EXHAUST AIR

EAT ENTERING AIR TEMPERATUREEFF EFFICIENCYESP EXTERNAL STATIC PRESSUREEXH EXHAUSTGTC GENERAL TRADES CONTRACTORLAT LEAVING AIR TEMPERATURELWT LEAVING WATER TEMPERATUREMFR MANUFACTURERNA NOT APPLICABLENTS NOT TO SCALEOA OUTSIDE AIRPD PRESSURE DROPRA RETURN AIRSA SUPPLY AIRSP STATIC PRESSURE

TSP TOTAL STATIC PRESSURETYP TYPICALUNO UNLESS NOTED OTHERWISEWB WET BULBWG WATER GAUGE

WPD WATER PRESSURE DROP

MOTORIZED DAMPER WITHACCESS DOOR

M

DUCTWORK

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

GEN

ERAL

INFO

RM

ATIO

N -

MEC

HAN

ICAL

M-001

Page 17: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DN

CODED NOTES:

1. REMOVE AND DISCONNECT EXISTING CONDENSING UNITS AND ALL ASSOCIATEDREFRIGERANT PIPING.

2. EXISTING FRESH AIR INTAKE TO REMAIN.

3. REMOVE EXISTING COMBUSTION AIR INTAKE AND SEAL WALL PENETRATION WEATHER TIGHT.

4. REMOVE EXISTING GAS FIRED UNIT HEATER, DISCONNECT FROM GAS PIPING.

5. REMOVE EXISTING GAS VENT AND SEAL WALL WEATHER TIGHT.

6. REMOVE EXISTING THERMOSTAT AND CONTROL WIRING.

7. REMOVE EXISTING WALL MOUNTED EXHAUST FAN AND ASSOCIATED DUCTWORK, SEAL WALLPENETRATION WEATHER TIGHT.

8. REMOVE EXISTING KITCHEN EXHAUST HOOD AND ALL ASSOCIATED DUCTWORK.

9. REMOVE EXISTING GRILLE AND ALL ASSOCIATED DUCTWORK, PATCH WALL PENETRATION.

10. REMOVE EXISTING DIFFUSER AND DUCTWORK.

11. REMOVE EXISTING RETURN GRILLE AND ASSOCIATED DUCTWORK.

12. REMOVE EXISTING DUCTLESS SPLIT SYSTEM AND ASSOCIATED REFRIGERANT PIPING.EXISTING CONDENSATE PIPING TO REMAIN AND TO BE RECONNECTED TO WHEN NEW UNIT ISSUPPLIED.

13. REMOVE EXISTING CONCENTRIC VENT.

14. REMOVE EXISTING FURNACE, DUCTWORK TO REMAIN.

15. EXISTING WALL MOUNTED UNIT HEATER TO REMAIN.

01/4"=1'-0" 2' 4' 8'1 FOOD SERVICE PLAN - TEMPLATE - DEMOLITIONN

GENERAL NOTES:

A. SEE SHEET M-001 FOR LEGEND AND GENERAL INFORMATION.

B. SEE SPECIFICATIONS FOR MORE INFORMATION.

T

T

T

(E)14/10

(E)8/6

(E)16/8

(E)12/8(E)16/10

(E)14/8

(E)8/6(D)12/8

(D)14/10

(D)12/10

(D)4"Ø

(E)8/6(E)8/6

(E)16/10

(E)8/6

(E)22/12

(E)22/12

(E)20/12

(E)18/12

(E)12/6(E)A1-10"Ø280

(E)A1-6"Ø140

(E)A1-10"Ø340

(E)A1-10"Ø340

(E)A1-6"Ø100

(E)A1-6"Ø100

(E)A1-6"Ø100

(D)F1-14/8240

(D)G1-14/8200

(E)J1280

(E)J1100

(E)J1140

(E)J1780

(E)J1100

1

(E)10/8

(E)14/10

23

3

4

5

6

7

8 9

9

10

(D)A1-10"Ø380

10

11

12

13

14

15

6

6

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

MEC

HAN

ICAL

DEM

OLI

TIO

N

MD101

Page 18: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DRY FOODSTORAGE

132

LAUNDRY /JANITOR

127

KITCHEN129

CORRIDOR126

OUTDOORSTORAGE

131

WORKROOM

118

AGENT128

INTERNS119

MAINT OFF120

AGENT125

CORRIDOR121

MECHANICAL124

EQUIP.124A

VOLUNTEERSOFFICE

122

COATS123

GREATROOM

130

CODED NOTES:

1. PROVIDE NEW REFRIGERANT LINE SETS TO EACH UNIT BACK TOTHE INTERIOR DUCTLESS SPLIT SYSTEM AND THE NEWFURNACE IN THE MECHANICAL ROOM. MOUNT UNITS ON NEWCONCRETE PADS PER DETAIL 6 ON SHEET M-501.

2. PROVIDE NEW FURNACE, RE-BALANCE SUPPLY AIR ASSPECIFIED ON THE DRAWING. PROVIDE NEW PROGRAMMABLETHERMOSTAT. RUN CONDENSATE TO FLOOR DRAIN.

3. PROVIDE NEW DUCTLESS SPLIT SYSTEM AND WALL MOUNTEDPROGRAMMABLE THERMOSTAT. CONNECT NEW DUCTLESSSPLIT TO EXISTING CONDENSATE PIPING. EXISTINGCONDENSATE PIPING RUNS TO EXISTING FLOOR DRAIN INMECHANICAL SPACE.

4. EXISTING WALL MOUNTED UNIT HEATER.

5. FRESH AIR INTAKE TO REMAIN, BALANCE FRESH AIR TO 320 CFM.

6. PROVIDE NEW PACKAGED ROOFTOP UNIT, SEE DETAIL 5 ONSHEET M-502 FOR MOUNTING INFORMATION.

7. EXISTING CONCENTRIC VENT AND WALL CAP.

8. MOUNT GRILLE ABOVE DOOR, PROVIDE SHEET METAL SLEEVETHROUGH WALL.

9. MOUNT GRILLE AS HIGH AS POSSIBLE BELOW CEILING, PROVIDESHEET METAL SLEEVE THROUGH WALL.

10. RE-BALANCE AIR DEVICE TO SPECIFIED CFM.

11. PROVIDE 4"Ø DRYER VENT AND EXTERIOR WALL CAP, RUNDRYER VENT ABOVE CEILING AND THEN DROP DOWN ANDCONNECT TO DRYER ALONG WALL.

12. RUN REFRIGERANT PIPING AS HIGH AS POSSIBLE UNDERCEILING STRUCTURE.

13. REFRIGERANT PIPING TO PENETRATE EXTERIOR WALL ANDTHEN DROP DOWN TO GRADE LEVEL. SECURE REFRIGERANTLINES TO WALL (TOTAL TWO LINE SETS). PROVIDE WALLSLEEVES AND SEAL WEATHER TIGHT.

14. RUN NEW REFRIGERANT PIPING ALONG EXTERIOR WALL ANDSECURE TO WALL.

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - MECHANICALN

T

T

(E)14/10

(E)A1-6"Ø140

(E)A1-10"Ø440

(E)8/6

(E)12/8(E)16/10

(E)14/8

(E)8/6

(E)8/6(E)8/6

(E)16/10

(E)8/6

(E)22/12

(E)22/12

(E)20/12

(E)18/12

(E)12/6(E)A1-10"Ø435

(E)A1-6"Ø120

(E)A1-10"Ø440

(E)A1-6"Ø120

(E)A1-6"Ø120

(E)J1120

(E)J1435

(E)J11000

(E)J1120

(E)14/10

A1-10"Ø300(TYP. OF 4)

D1-6"Ø100

D1-6"Ø100

10/12

10/12

GENERAL NOTES:

A. SEE SHEET M-001 FOR LEGEND AND GENERAL INFORMATION.

B. SEE SPECIFICATIONS FOR MORE INFORMATION.

T

1

2

G1

3

G1

4

L-1

6"Ø EF-3

RTU-56

7

10

10

10

D2-6"Ø100

10

D1-6"Ø100

10

20/12

10

G3

4"Ø

L-1

10"Ø

G1

10

(E)10/8

G18

9

10

10

10

10

11

5

HC-2

CU-2

CU-1

1

HC-1RSRL

RSRL

RSRL

12

13

14

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

MEC

HAN

ICAL

M-101

Page 19: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

LOW VELOCITY SUPPLY

AIR FLOWAIR FLOW

PROVIDE 18" LONG ORANGE MARKERTAPE ATTACHED TO DAMPER TOIDENTIFY LOCATION

D

45° LEAD IN

ROUND BRANCHDUCT

LOW VELOCITYRETURN/EXHAUST

LOW VELOCITYSUPPLY (SPIN-IN)

2DTAP SIZE

BRANCH DUCT(TYP)

VOLUME DAMPER(TYP)

RECTANGULARMAIN DUCT

AIR FLOW AIR FLOW

45° LEAD IN 45° LEAD INSCOOP

MAIN DUCT

NTS1 DETAIL - BRANCH CONNECTIONS

SUPPLY AIRDIFFUSER (LAY-INFRAME)

INSULATED NON-METALLICFLEXIBLE CONNECTION (MAX 3 FT.)

18" LONG ORANGEMARKER TAPE ATTACHEDTO DAMPER TO IDENTIFYLOCATION

TOS.A.OPENING

INSULATEDROUND DUCT

SECURE FLEXIBLE DUCT TO DUCT COLLARSWITH SCREWS AND DRAWBANDS. PROVIDEADDITIONAL DRAWBANDS AND SEAL FLEXOUTER JACKET TO DUCT COLLARS

VOLUME DAMPER LOCATION WHERE DAMPERWOULD BEINACCESSIBLE AT TAKE-OFF, PROVIDE WITH 3"EXTENDED SHAFT, HANDLE AND COLLAR

SHEET METAL ELBOW REQUIRED

NTS2DETAIL - DIFFUSER MOUNTING (SUPPLY DUCT CLOSE TO CEILING)

NUTS AND WASHERS BOTHSIDES OF ANGLE (TYP)

1-1/4" X 1-1/4" X 3/16"ANGLE IRON SUPPORTS

1/2" THREADEDROD(TYP)

NTS3 DETAIL - DUCTWORK HANGER

CEILING

SUPPLY DUCT

SPIN IN BRANCH TAP FITTING,STRAIGHT SIDE, WITH MANUAL DAMPER.DAMPER SHAFT IN HORIZONTAL

CEILING DIFFUSER

ROUNDSHEETMETALBRANCH DUCT

FLEXIBLE DUCT, DIAMETER AS NOTED ON PLAN

DUCT STRAP HANGER. ATTACH TO STRUCTURE

SHEETMETAL BOX WITHADAPTER CONNECTIONTO DIFFUSER DUCTSTRAPHANGER. ATTACH TOSTRUCTURE

WALL

SLEEVE ORPREPARED OPENING.

SHEET METAL SCREW(TYP)SEALANT

PACKING

DUCT

4" WIDE CLOSURE COLLARWHERE DUCT IS EXPOSED(ATTACH TO DUCT)

NOTES:

A. DETAIL IS NOT APPLICABLE WHERE FIRE DAMPER, REGISTER, ORDIFFUSER IS PROVIDED.

B. EXTERNALLY INSULATED DUCT SHALL BE CAULKED TO PROVIDE ACOMPLETE SEAL BETWEEN THE INSULATION AND CLOSURECOLLAR.

NTS5 DETAIL - TYPICAL DUCT PENETRATION THRU WALLNTS4 DETAIL - CEILING DIFFUSER

NTS7 DETAIL - ROOFTOP UNIT CONDENSATE DRAIN PIPING

SLOPE

ROOFTOP UNIT CURB

ROOFTOP UNIT

ROOF

C.O. PLUG

PROVIDE DRAIN PIPING AT ALLROOFTOP UNIT DRAINCONNECTIONS

MIN. DIMENSION EQUAL TO THESUPPLY FAN SUCTION PRESSUREDIVIDED BY 2 PLUS 1"

MIN. DIMENSION EQUAL TO THESUPPLY FAN SUCTIONPRESSURE

T.O.S. X X EXTERIOR GRADEXX X

EXTERIOR EQUIPMENT PAD

4" N

OMIN

AL

6X6-W1.4 X W1.4 W.W.F.

3"

PLAN DIMENSION AS REQ'D

FOR EQUIPMENT (COORDINATEW/APPROVED SHOP DRAWINGS)

NTS6DETAIL - EQUIPMENT CONCRETE PAD

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

DET

AILS

- M

ECH

ANIC

AL

M-501

Page 20: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

*

**

OUTDOOR DUCT INSULATIONWITH WEATHER PROOFINGCAULK AROUND PERIMETERRUN COUNTERFLASHING UPUNDER TERMINATION BARBY HVAC CONTRACTORROOF DECK

ROOF MATERIALBY GTC

FRAMINGBY GTC

EXPANDING POLYURETHANEFOAM INSUL. AROUND PERIM.OF DUCT IN METAL DECK PLANE

OPENING THROUGHROOF BY GTC

PRE-FABRICATEDROOF CURB

* VARIES SEE ARCHITECTURAL ROOF PLAN** 12" MINNOTES:1. TURN ROOF CURB TO GENERAL TRADE CONTRACTOR FOR

INSTALLATION ON ROOF.2. THE GTC SHALL CUT ROOF OPENINGS FOR DUCTWORK PROVIDED

BY THE MC. COORDINATE WITH THE MC TO CUT THESEOPENINGS. THE STEEL FRAMING UNITS ARE 3x3x3/8 STEELANGLES, FURNISHED AND INSTALLED BY THE GTC.

NTS3 DETAIL - DUCT THRU ROOF CURB

WALL PENETRATION

BACKER ROD OR MINERAL WOOLDAMMING MATERIAL

PIPE

PIPE JACKET& INSULATION

PIPE SLEEVEFIRE BARRIER CAULK. THICKNESSBASED ON MANUFACTURERSRECOMMENDATIONS ANDPRODUCT LISTING.

NTS1 DETAIL - FIRE RATED PIPING WALL PENETRATION

PIPE SLEEVEPROVIDE BACKER ROD ANDSEALANT (TYP)

PIPE JACKET AND INSULATION

PIPE

NTS2 DETAIL - PIPING WALL PENETRATION

SECTION A-A

A REMOVABLE FRONT FACE LOUVERB (4) STAINLESS STEEL AUGER TIP SCREWS

(301) C MONOLITHIC BOX CAVITYD GRAVITY DAMPERE DUCT PORT (UP TO 6" DIAMETER)

B

D

C

A

BACK VIEW

E

A

A

NOTES:

F BIRDSCREEN

1158"

1034"

78" 91

8"

618"

F

NTS4 DETAIL - LOUVER SINGLE EXHAUST

ROOFTOP UNIT

14"

36"CLEARANCE

RETURN DUCTSUPPLY DUCT PRE-FABRICATEDEQUIPMENT CURB

ROOF

CEILING

ECONOMIZERHOOD

36"CLEARANCE

CONDENSERFAN

ROOFINGMATERIAL

VIBRATIONISOLATOR

FLASHING ANDCOUNTER FLASHING

NTS5 DETAIL - ROOFTOP UNIT

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

DET

AILS

- M

ECH

ANIC

AL

M-502

Page 21: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

MODELTAG CFME.S.P.

(IN. W.G.) FLA BHP RPM TOTALMBH

SENSIBLEMBH D.B. W.B.

E.A.T. (°F)

DX COOLING COIL DATA

D.B.

NO. OFSTAGESREFRIG.

W.B.

HEATING DATA

INPUTMBH

OUTPUTMBH

FUELTYPE

E.A.T.(°F)

L.A.T.(°F)

CONDENSER DATA

FLA(EACH)

NOTES

.80 1236 80.0 67.0 R410A 60 48

PACKAGED ROOFTOP UNIT SCHEDULE

RTU-5 1600 1.20 41.2 35.0 57.54 57.54 70.0 119.60

EQUIPMENT BASED ON TRANE UNLESS NOTED OTHERWISE

HP(EACH)

YSC047 --

UNIT DATA SUPPLY FAN DATA

L.A.T. (°F)

ELECTRICAL

MCA MOCP

40

VOLTS

20830

COMPRESSOR DATA

TYPE

SCROLL

RLA(EACH)

1

PHASE

3

FILTERS

DEPTH(IN.) MERV

2 8

NO. OFCOMP.

NO. OFFANS

NAT.GAS1 1, 2, 3, 4, 5, 6, 7 1 2.5 0.4 14.0

NOTES:1. SINGLE POINT POWER CONNECTION.2. POWER DISCONNECT AND CONVENIENCE OUTLET.3. DRY BULB ECONOMIZER OPERATION.

4. PROVIDE HINGED ACCESS DOORS.5. PROVIDE 14" ROOF CURB.6. STAINLESS STEEL HEAT EXCHANGER.7. LOW AMBIENT CONTROLS.

EQUIPMENT BASED ON BROAN UNLESS NOTED OTHERWISEFAN SCHEDULE

UNIT DATA

TAG LOCATION MODEL FUNCTION FAN TYPE E.S.P.IN W.G. CFM RPM TYPE OF

DRIVE WATTS VOLTS PHASE

ELECTRICAL DATANOTESTYPE OF

DAMPER

SOUNDRATING IN

SONESAMPS

EF-3 EXHAUST CENTRIFUGAL 0.25 110X110 1725 BACKDRAFT DIRECT 7.7 120 1 0.3 0.3 1, 2, 3

EQUIPMENT BASED ON TITUS UNLESS NOTED OTHERWISEAIR DEVICE SCHEDULE

UNIT DATA

TAG FUNCTION MODEL FACESIZE

FRAMETYPE MATERIAL FINISH DAMPER N.C.

MAX.NOTES

14" X10"

D1 24" X 24"PAS SURFACE STEEL WHITE -- 20

SUPPLY DIFFUSER TAG: TAG-NECK SIZECFM

SUPPLY

D= DIFFUSERG= GRILLER= REGISTER

G1 350FL SURFACE STEEL -- 20RETURN / EXHAUST WHITE

RETURN / EXHAUST GRILLE TAG: TAGCFM

D2 STEEL --SUPPLY WHITE 2012" X 12"PAS SURFACE

PROVIDE MOLDED INSULATION BLANKET FOR ALL

PROVIDE MOLDED INSULATION BLANKET FOR ALL

NECKSIZE

SEE PLANS

SEE PLANS

10" X 8"

SUPPLY AIR DEVICES ON TOP FLOOR.

SUPPLY AIR DEVICES ON TOP FLOOR.

NOTES:1. PROVIDE FACTORY INSTALLED DISCONNECT SWITCH.2. PROVIDE CEILING MOUNTING BRACKETS.3. EXHAUST FAN RUNS CONTINUOUSLY.

LAUNDRY / JANITOR

NOTES:1. PROVIDE WITH BIRD SCREEN2. UV STABILIZED3. REMOVABLE FRONT FACE LOUVER

UNIT DATA

TAG SERVICE MODEL FUNCTION DIMENSIONW x H x D

FREE FACEAREA (SF) CFM A.P.D. IN.

W.G. DAMPERNOTES

EQUIPMENT BASED ON XVENT UNLESS NOTED OTHERWISELOUVER SCHEDULE

VEL. FPM

L-1 EXHAUST 11.75x10.85x9.85 NA 110 -- -- BACKDRAFT 1, 2, 3, 46SEB

4. COLOR TO BE SELECTED BY THE ARCHITECT.

LAUNDRY / JANITOR

24" X16"350FL SURFACE STEEL -- 20RETURN / EXHAUSTG2 WHITESEE PLANS

MIN. O.A.

182

EQUIPMENT BASED ON MITSUBISHI UNLESS NOTED OTHERWISEDUCTLESS SPLIT SYSTEM SCHEDULE

INDOOR UNIT DATA

TAG LOCATION MODEL MAX CFM TOTALMBH VOLTS PHASE MCA REFRIG.

TYPE TAG MODEL VOLTS PHASE MCA MOCP

INDOOR UNIT EVAPORATOR DATA OUTDOOR UNIT DATANOTES

HC-2 EQUIP ROOM R-410A CU-2533 18 208 1 1MSZ-HE18NA 208 1 14 15MUZ-HE18NA

NOTES:1. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT SWITCH.2. PROVIDE WALL MOUNTED THERMOSTAT.3. SINGLE POINT POWER CONNECTION TO OUTDOOR UNIT.4. PROVIDE UNIT WITH FRONT WIND BAFFLE FOR 0°F COOLING LOW AMBIENT OPERATION (# WB-PA4).5. RUN CONDENSATE TO EXISTING CONDENSATE LINE

1, 2, 3, 4, 5

HEATING

TOTALMBH

20.9

MAX CFM

512

SEER

18

HC-1 OFFICE AREA CNPVP6124ALA

ESP(IN WC)TAG

FURNACE & BLOWER

MODEL NO.SERVICE TYPE (MBH)INPUT

CFM

COOLING COIL

MODEL NO.MOCP

VOLT

PHASE TOTAL

EAT °F

DB WB

COOLING CAPACITY (MBH)

SENSIBLE

CONDENSING UNITS

VOLTMODEL NO. MCA PHASE SEER

NOTES

1151

2081

(MBH)OUTPUT O.A. AIR

MIN

CFMWEIGHT(LBS)

CU-1

UNIT TAG

SOUNDPOWER

PROGRAMMABLE THERMOSTAT WITH AUTO CHANGEOVER. CRANKCASE HEATER, FILTER DRIER, LIQUID-LINE SOLENOID VALVE, LOW-AMBIENT CONTROLLER, WINTERSTART CONTROL, MERV-8 FILTER

AFUE% (dBA)

FIXED-CAPACITYDIRECT-VENT

REFRIGERANT TO BE R0410A

MCA AHRI

EQUIPMENT BASED ON BRYANT UNLESS NOTED OTHERWISENATURAL GAS FURNACES

120 117 96 1750 .50 CNPVP6124ALA 80.00 67.00 50.2 35.92 28 16 272 7814.7

20320 116BNA060000

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

SCH

EDU

LES-

MEC

HAN

ICAL

M-601

Page 22: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

X

OS X

J

W

C,F

X

C,F

X

C,F

NOTE: NOT ALL SYMBOLS MAY BE USED.

D

GENERAL PURPOSE LUMINAIRE:REFER TO LUMINAIRE SCHEDULE FORADDITIONAL INFORMATIONGENERAL PURPOSE LUMINAIRE ON EMERGENCYPOWER: REFER TO LUMINAIRE SCHEDULE FORADDITIONAL INFORMATION

NIGHT LIGHT LUMINAIRE. WIRE AHEAD OFLOCAL SWITCHING

ROUND LUMINAIRE: REFER TO LUMINAIRESCHEDULE FOR ADDITIONAL INFORMATIONWALL WASHER: REFER TO LUMINAIRESCHEDULE FOR ADDITIONAL INFORMATIONWALL MOUNTED LUMINAIRE: REFER TOLUMINAIRE SCHEDULE FOR ADDITIONALINFORMATIONWALL MOUNTED DECORATIVE LUMINAIRE:REFER TO LUMINAIRE SCHEDULE FORADDITIONAL INFORMATIONWALL MOUNTED FLOOD LIGHT: REFER TOLUMINAIRE SCHEDULE FOR ADDITIONALINFORMATIONEMERGENCY LIGHTEXIT SIGNCEILING MOUNTED ILLUMINATED EXIT SIGNWITH DIRECTIONAL ARROWSEMERGENCY DUAL FACE ILLUMINATED EXITSIGN WITH DIRECTIONAL ARROWS

EXIT SIGN WITH INTEGRAL HEADS

SWITCH: X=BLANK-SINGLE POLE 20A, TOGGLE;X=3-THREE WAY; X=4-FOUR WAY; X=P-PILOTLIGHT; X=K-KEY; X=MS-MOMENTARYWALL MOUNTED OCCUPANCY SENSOR:X=BLANK-DUAL TECHNOLOGY; X=IR-PASSIVEINFRARED; X=US-ULTRASONIC

DIMMERJUNCTION BOX

PANELBOARD

F,C

F,C

XYZ

M

J

SPD

NOTE: NOT ALL SYMBOLS MAY BE USED.20A DUPLEX RECEPTACLE WITH COVER PLATE:X=TYPE, Y"=NON-STANDARD MOUNTING HEIGHT,Z=SPECIAL DESIGNATION, (18" AFF TYPICAL)

XYZ

FLOOR OR CEILING MOUNTED DUPLEXRECEPTACLE: F=FLOOR, C=CEILINGDUPLEX RECEPTACLE: ABOVE COUNTER (48"AFF TYPICAL)

DOUBLE-DUPLEX RECEPTACLE WITH SINGLECOVER PLATESIMPLEX RECEPTACLE WITH COVER PLATE

WALL MOUNTED SPECIAL RECEPTACLE: REFERTO PLANS FOR ADDITIONAL INFORMATIONFLOOR OR CEILING MOUNTED SPECIALRECEPTACLE: F=FLOOR, C=CEILING REFERTO PLANS FOR ADDITIONAL INFORMATIONSURFACE MOUNTED RACEWAYSTANDARD DISCONNECT SWITCH:X=DISCONNECT SIZE, Y=NUMBER OF POLES

XYZ

STANDARD FUSED DISCONNECT SWITCH:X=DISCONNECT SIZE, Y=FUSE SIZE, Z=NUMBEROF POLES

XYZ

MOTOR STARTER: X=STARTER SIZE,Y=NUMBER OF POLES

XYZ

COMBINATION MOTOR STARTER/DISCONNECTSWITCH: X=STARTER SIZE, Y=FUSE SIZE,Z=NUMBER OF POLESMOTOR (BY OTHERS): PROVIDE POWER ASINDICATEDFRACTIONAL HORSEPOWER MANUAL MOTORSTARTERJUNCTION BOXSURGE PROTECTIVE DEVICE

PANELBOARD

NOTE: NOT ALL SYMBOLS MAY BE USED.

WALL MOUNTED PHONE OUTLET (42" AFF):

CEILING OR FLOOR MOUNTED PHONE OUTLET:C=CEILING, F=FLOORWALL MOUNTED DATA OUTLET (18" AFF):X=NUMBER OF OUTLETS

POKE THROUGH DEVICE: PROVIDE (1) DUPLEXOUTLET AND (2) CAT6 DATA JACKS, TERMINATEDATA ON PATCH PANEL IN NEAREST IT CLOSET;A=POWER / A/V / DATA, B=POWER / DATASURFACE MOUNTED RACEWAYCABLE TRAYEQUIPMENT RACKTELEPHONE TERMINAL BOARD/PLYWOODBACKBOARD: REFER TO PLANS FOR ACTUALLENGTHS

CEILING OR FLOOR MOUNTED DATA OUTLET:C=CEILING, F=FLOORWALL MOUNTED PHONE/DATA OUTLET (18" AFF):X=NUMBER OF OUTLETS (P=PHONE, D=DATA)CEILING OR FLOOR MOUNTED PHONE/DATAOUTLET: C=CEILING, F=FLOOR

DUPLEX RECEPTACLE ON EMERGENCY CIRCUITWITH COVER PLATE: X=TYPE,Y"=NON-STANDARD MTG HEIGHT, Z=SPECIALDESIGNATION, (18" AFF TYPICAL)

XYZ

CEILING MOUNTED OCCUPANCY SENSOR:X=BLANK-DUAL TECHNOLOGY; X=IR-PASSIVEINFRARED; X=US-ULTRASONIC

OS X

WEATHER RESISTANT DUPLEX RECEPTACLE,GROUND FAULT CIRCUIT INTERRUPTING WITHIN-USE COVER

WP

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW WORK

PT

WIRELESS ACCESS POINT

GENERAL NOTES:

1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. CONTRACTOR IS ALSO RESPONSIBLE FOR ALL FEES ANDPERMIT COSTS RELATED TO THE PROJECT.

2. BEFORE CONSTRUCTION WORK BEGINS THE CONTRACTOR SHALL VERIFY THE LAYOUT DIMENSIONS AND REPORTTO THE ARCHITECT ANY DISCREPANCIES.

3. IN NO CASE ARE DRAWINGS TO BE SCALED. SIZES, LOCATIONS AND DETAILING SHALL BE AS REQUIRED BY THEINTENT OF THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING THE WORK.

4. CUT AND PATCH ALL EXISTING MATERIALS AND FINISHES TO MATCH THE EXISTING MATERIALS. CONTRACTOR ISRESPONSIBLE FOR PATCHING/REPAIRING ANY WALLS, CEILINGS, AND FLOORS THAT WERE OPENED UP TO ACCESSTHEIR WORK.

5. IF MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE CONTRARY TO THE CONTRACT DOCUMENTS, THECONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER, IN WRITING IMMEDIATELY TO RESOLVE DISCREPANCIESPRIOR TO INSTALLATION.

6. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES,LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THEMOST STRINGENT REQUIREMENTS SHALL GOVERN. REQUIREMENTS INCLUDE, BUT ARE NOT NECESSARILY LIMITEDTO, THE CURRENTLY APPLICABLE EDITIONS OR PUBLICATIONS OF THE FOLLOWING:

A. STATE FIRE CODEB. NATIONAL FIRE PROTECTION ASSOCIATIONC. NATIONAL ELECTRIC CODED. ALL LOCAL AND MUNICIPAL CODESE. OHIO BUILDING CODEF. AMERICANS WITH DISABILITIES ACT

7. ONLY NEW MATERIALS, FREE FROM DEFECTS, WILL BE PERMITTED IN THE CONSTRUCTION. REJECTED ITEMS SHALLBE REMOVED IMMEDIATELY FROM THE WORK AND REPLACED WITH ITEMS OF THE QUALITY SPECIFIED. FAILURE TOREMOVE REJECTED MATERIALS AND EQUIPMENT SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITYFOR THE QUALITY OF MATERIALS AND INSTALLATION.

8. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN,UNIFORM APPEARANCES WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS, OR DISCOLORATION.JOINTING SHALL BE CLOSE FITTING, NEAT AND WELL SCRIBED. THE FINISH WORK SHALL HAVE NO EXPOSEDUNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALLHAVE THE PROVISION FOR EXPANSION, CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS,BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS.

9. THE CONTRACTOR SHALL CHECK ARCHITECTURAL AND STRUCTURAL CLEARANCES FOR THE ACCESSIBILITY ANDMAINTENANCE OF EQUIPMENT AND MECHANICAL AND ELECTRICAL SYSTEMS. NO ALLOWANCE OF ANY KIND WILL BEMADE FOR THE CONTRACTOR'S NEGLIGENCE TO FORESEE MEANS OF INSTALLING EQUIPMENT INTO POSITIONINSIDE STRUCTURES.

10. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF DRAWINGS ANDSPECIFICATIONS WILL BE ACCEPTABLE IN CONSEQUENCE OF OWNER'S OR ARCHITECT'S FAILURE TO DISCOVER ORTO POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION; NOR WILL PRESENCE OF INSPECTORS ONWORK RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR SECURING QUALITY AND PROGRESS OF WORK ASREQUIRED BY CONTRACT. DEFECTIVE WORK REVEALED WITHIN REQUIRED TIME GUARANTEES SHALL BE REPLACEDBY WORK CONFORMING WITH INTENT OF CONTRACT. NO PAYMENT WHETHER PARTIAL OR FINAL, SHALL BECONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS.

11. CONTRACTORS SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME TO AVOID DELAYS INCONSTRUCTION. IF ANY ITEMS ARE FOUND TO BE UNAVAILABLE OR HAVE A LONG LEAD TIME, THE CONTRACTORSHALL NOTIFY THE OWNER AND ARCHITECT/ENGINEER IMMEDIATELY.

12. ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS BY THE CONTRACTOR OR THEIR SUBCONTRACTORSWITHOUT WRITTEN APPROVAL OF THE OWNER AND ARCHITECT/ENGINEER SHALL RESULT IN THE CONTRACTORTAKING FULL LIABILITY OF ALL MODIFICATIONS TO THE ORIGINAL CONSTRUCTION DOCUMENTS.

13. ALL CORRESPONDENCE WITH THE CONTRACTING AUTHORITY AND THE OWNER/USER IS TO BE COORDINATEDTHROUGH THE ARCHITECT.

14. CONTRACTOR IS RESPONSIBLE FOR PATCHING/REPAIRING ANY FIREPROOFING DAMAGED OR REMOVED DURINGTHEIR SCOPE OF WORK. WHERE EXISTING WALLS ARE BEING REMOVED, THE CONTRACTOR WILL PATCH/REPAIRFIREPROOFING THAT MAY HAVE BEEN REMOVED TO ALLOW FOR THE ATTACHMENT OF THE STUD WALL TRACK TOTHE EXISTING STRUCTURE.

15. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES WITH CORRECT INFORMATION AT THE END OFPROJECT AND PROVIDE NEW TYPE DIRECTORY CARDS FOR ALL PANEL BOARDS.

16. THE ELECTRICAL DESIGN DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EXACT LOCATION OFEQUIPMENT, LIGHTING, AND DEVICES UNLESS DIMENSIONS ARE GIVEN FOR CLEARANCES, ETC. LIGHTING, DEVICESAND ELECTRICAL EQUIPMENT ARE TO BE INSTALLED ALONG THE GENERAL PLANS SHOWN ON THE DRAWINGS, BUTKEEPING IN MIND ACTUAL BUILDING CONDITIONS WHICH MUST BE CONFIRMED WITH-IN THE ACTUAL WORK AREA.CONTRACTORS, IN THEIR BIDS, ARE REQUIRED TO INCLUDE ALL LABOR AND MATERIALS AND OTHER RELATEDWORK NECESSARY TO PROVIDE MINOR OFFSETS IN ELECTRICAL INSTALLATION TO AVOID CONFLICT WITH OTHERWORK ON THIS PROJECT, OR AS REQUIRED IN ORDER TO OBTAIN MAXIMUM HEAD ROOM OR EQUIPMENT ACCESS INSPACES.

17. AN ATTEMPT HAS BEEN MADE TO SHOW ALL ELECTRICAL ITEMS TO REMAIN OR BE REMOVED. CONTRACTOR SHALLFIELD VERIFY EXISTING CONDITIONS AND REMOVE AND/OR RELOCATE ANY ITEM WHICH INTERFERES WITH NEWCONSTRUCTION.

E-001

ED101

E-101

GENERAL INFORMATION - ELECTRICAL

FLOOR PLAN - ELECTRICAL DEMOLITION

FLOOR PLAN - LIGHTING

E-201 FLOOR PLAN - ELECTRICAL

ABBREVIATIONSNOTE: NOT ALL ABBREVIATIONS MAY BE USED.

(A) EXISTING TO BE ABANDONED(D) EXISTING TO BE DEMOLISHED(E) EXISTING TO REMAIN(F) FUTURE(R) EXISTING TO BE RELOCATEDA AMPERE

AC ALTERNATING CURRENT OR AIR CONDITIONERAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAIC AMPS INTERRUPTING CAPACITY

ANNC ANNUNCIATORAWG AMERICAN WIRE GAUGEBPS BOLTED PRESSURE SWITCH

C CONDUITCB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCM CONSTRUCTION MANAGERDC DIRECT CURRENTDP DISTRIBUTION PANELBOARD

DTT DOUBLE TWIN TUBEEB ELECTRONIC BALLASTEC ELECTRICAL CONTRACTOREM EMERGENCY

EMT ELECTRICAL METAL TUBINGEWC ELECTRIC WATER COOLERFA FIRE ALARM

FLA FULL LOAD AMPSG GROUND

GC GENERAL TRADES CONTRACTORGFCI GROUND FAULT CIRCUIT INTERRUPTERGEN GENERATORHOA HAND-OFF-AUTOMATICHP HORSEPOWER

HPC HIGH PRESSURE CONTACT SWITCHHZ HERTZIG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUITINCD INCANDESCENTKVA KILOVOLT AMPEREKW KILOWATTLTG LIGHTING OR LIGHTLRA LOCKED ROTOR AMPS

ABBREVIATIONSNOTE: NOT ALL ABBREVIATIONS MAY BE USED.

MCA MINIMUM CIRCUIT AMPACITYMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTERMDP MAIN DISTRIBUTION PANELMLO MAIN LUGS ONLY

MOCP MAXIMUM OVERCURRENT PROTECTIONMSB MAIN SWITCHBOARDMH METAL HALIDE

MTS MANUAL TRANSFER SWITCHNAC NOTIFICATION APPLIANCE CIRCUITNC NORMALLY CLOSEDNO NORMALLY OPENNF NON-FUSED

OCC OCCUPANCYPA PUBLIC ADDRESSPB PULL BOX OR PUSH BUTTON

PVC POLYVINYL CHLORIDE (PLASTIC PIPE)PWR POWER

RECPT RECEPTACLESTP SHIELDED, TWISTED PAIRTC TIME CLOCK

TRT TRIPLE TUBETYP TYPICALUNO UNLESS NOTED OTHERWISEUTP UNSHIELDED, TWISTED PAIR

V VOLTW WATT

WAP WIRELESS ACCESS POINTWH WATTHOURWP WEATHERPROOF, NEMA 3R UNO

XFMR TRANSFORMERZ IMPEDANCEØ PHASE

LIGHTING SYMBOLS POWER SYMBOLS

LINE TYPE LEGENDTELECOMM SYMBOLS

SHEET LIST

E-501 SCHEDULES - ELECTRICAL

E-701 ONE LINE - ELECTRICAL

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

GEN

ERAL

INFO

RM

ATIO

N -

ELEC

TRIC

AL

E-001

Page 23: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DN

CODED NOTES:

1. EXISTING OUTDOOR HVAC UNITS TO BE REMOVED. DISCONNECT EXISTING ELECTRICAL FEED ANDREMOVE CONDUIT AND WIRING BACK TO SOURCE..

2. REMOVE ALL ELECTRICAL FEEDS TO KITCHEN HOOD BACK TO SOURCE. COORDINATE WITHMECHANICAL CONTRACTOR ANY ADDITIONAL ELECTRICAL FEEDS TO ASSOCIATED FANS THAT NEEDREMOVED.

3. FIRE SUPPRESSION PULL STATION TO BE REMOVED. COORDINATE WITH MECHANICAL CONTRACTOR.

4. REMOVE ELECTRICAL FEED AND CONDUIT TO OVERHEAD DOOR, ALONG WITH DOOR CONTROLS.

5. ALL LIGHTING IN THIS AREA TO BE REMOVED. REMOVE FIXTURE, CONDUIT AND WIRING. CONTRACTORTO MAINTAIN OTHER EXISTING LIGHTING ON THIS CIRCUIT THAT IS TO REMAIN.

6. EXISTING FIRE ALARM HORN STROBE TO BE RELOCATED. SEE DRAWING E-201 FOR NEW LOCATION.

7. EXISTING FIRE SUPPRESSION CONTROL PANEL TO BE REMOVED. REMOVE ELECTRICAL FEED ANDCONDUIT BACK TO SOURCE. COORDINATE WITH MECHANICAL CONTRACTOR.

8. REMOVE EXISTING RECEPTACLE, BACK BOX, CONDUIT AND WIRING. CONTRACTOR TO MAINTAINOTHER DEVICES ON THIS CIRCUIT THAT ARE TO REMAIN.

9. REMOVE LIGHT SWITCH. MAINTAIN BACK BOX FOR REUSE FOR NEW LIGHTING SWITCH.

10. EXISTING UNIT HEATER TO BE REMOVED. REMOVE ELECTRICAL FEEDER AND CONDUIT BACK TOSOURCE.

11. REMOVE EXTERIOR WEATHERPROOF RECEPTACLE, CONDUIT AND WIRING BACK TO SOURCE.

12. EXISTING FIRE ALARM CONTROL PANEL. PANEL TO REMAIN AND STAY OPERATIONAL DURINGCONSTRUCTION PHASE.

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - ELECTRICAL DEMOLITIONN

3

3

3

3

'A' 'AA'

'MDP'

(D)

1

GENERAL NOTES:

A. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE EQUIPMENT BEING REMOVED AND REUSED.

B. CONTRACTOR SHALL COORDINATE THE LOCATION TO STORE THE EQUIPMENT DURING CONSTRUCTIONAND SECURE TRANSPORTATION OF EQUIPMENT IF NEEDED TO BE STORED OFF SITE. ONCE THEEQUIPMENT IS PLACED IN ITS TEMPORARY STORAGE LOCATION, THE CONTRACTOR IS RESPONSIBLE FORPROTECTING THE PACKAGED EQUIPMENT AND THE TRANSPORTATION BACK TO SPACE.

C. THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARILY DISCONNECTING ALL UTILITIES FOR EQUIPMENT TOBE REMOVED OR RELOCATED.

D. THE CONTRACTOR SHALL VERIFY ANY RECEPTACLES THAT ARE NOT BEING USED AND REMOVE AS ITINTERFERES WITH NEW CONSTRUCTION. REMOVE DEVICE, WIRING AND CONDUIT BACK TO SOURCE.VERIFY IF EXISTING BACK BOXES CAN BE REUSED FOR NEW EQUIPMENT LOCATION AND REWIRE ASSHOWN.

E. SOME EQUIPMENT SHOWN FOR REFERENCE ONLY.

F. CONTRACTOR SHALL VERIFY ANY ELECTRICAL DEMOLITION THAT MIGHT EFFECT EXISTING EQUIPMENT,RECEPTACLES, AND LIGHTING THAT IS TO REMAIN AND BE MAINTAINED.

J

2 (R)

3

M

4

5

5

6

7

8

8

8

8

8

8

9

10

(D)

(D) (D)

11

12

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

ELEC

TRIC

AL D

EMO

LITI

ON

ED101

Page 24: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

DRY FOODSTORAGE

132

LAUNDRY /JANITOR

127

KITCHEN129

CORRIDOR126

OUTDOORSTORAGE

131

WORKROOM

118

AGENT128

INTERNS119

MAINT OFF120

AGENT125

CORRIDOR121

MECHANICAL124

EQUIP.124A

VOLUNTEERSOFFICE

122

COATS123

GREATROOM

130

GENERAL NOTES:

A. ALL EMERGENCY LIGHTING, EXIT SIGNS AND NIGHT LIGHTINGSHALL BE WIRED AHEAD OF LOCAL SWITCHING.

CODED NOTES:

1. EMERGENCY LIGHTING SHALL BE MOUNTED AT 8'-0" AFF.

2. PROVIDE OCCUPANCY SENSOR. SEE WIRING DIAGRAM ONSHEET E-501 FOR MORE INFORMATION.

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - LIGHTING

R1OS

3

3

R2

3

R1

R1

R1

OS

R1R1

R2

OS

3

R2

NL

NLR1

EX1

EX

EM

EM

EM

K1

EX

K1-6

EM

EM

N

'A' 'AA'

'MDP'

EX

NLR2

1

1

1

1

1

2

22

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

LIG

HTI

NG

E-101

Page 25: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

D1

E1

H1

DRY FOODSTORAGE

132

LAUNDRY /JANITOR

127

KITCHEN129

CORRIDOR126

OUTDOORSTORAGE

131

WORKROOM

118

AGENT128

INTERNS119

MAINT OFF120

AGENT125

CORRIDOR121

MECHANICAL124

EQUIP.124A

VOLUNTEERSOFFICE

122

COATS123

GREATROOM

130

CODED NOTES:

1. PROVIDE GFCI/TAMPER-PROOF RECEPTACLE AT THISLOCATION.

2. RELOCATED FIRE ALARM HORN STROBE FROM DEMOLITION.RECONNECT WIRING.

3. NEW FIRE ALARM DEVICE. WIRE BACK TO MAIN FIRE ALARMPANEL AND MAKE ALL CONNECTIONS.

4. ELECTRICAL CONTRACTOR SHALL PROVIDE 120V, 1ØCONTROL WIRING BETWEEN MICRO-SWITCH IN FIREPROTECTION SYSTEM AND HOOD SWITCH PANEL.

5. REMOTE MANUAL PULL STATION FOR ANSUL SYSTEMFURNISHED WITH FIRE SYSTEM. ELECTRICAL CONTRACTORTO PROVIDE 4" OCTAGON BOX (AT 48" AFF. TO CENTERLINE)AND 1/2" CONDUIT WITH PULL STRING TO 6" ABOVE CEILING.COORDINATE WITH FIRE PROTECTION INSTALLER.

6. ELECTRICAL CONTRACTOR TO FURNISH 208V, 3Ø POWER(K1-1, 3, 5) TO MOTOR STARTER PANEL MOUNTED ONMAKE-UP AIR UNIT (SINGLE SUPPLY CIRCUIT) AND EXTENDFROM MOTOR STARTER PANEL TO REMOTE EXHAUST FAN('EF-1') AND SUPPLY FAN ('S-1').

7. ELECTRICAL CONTRACTOR TO FURNISH CONTROL WIRING120V, 1Ø (K1-11) BETWEEN HOOD SWITCH PANEL ANDMOTOR STARTER PANEL MOUNTED ON MAKE-UP AIR UNIT.

8. NEW ROOFTOP UNIT 'RTU-5'. PROVIDE 3 #8 AWG, 1 #10 AWGIN 3/4" CONDUIT TO NEW 'RTU-5' (MDP-13,15,17).CONTRACTOR SHALL VERIFY CONDUIT LENGTH ANDROUTING PRIOR TO ROUGH-IN. COORDINATE WITHMECHANICAL CONTRACTOR.

9. NEW EXHAUST FAN 'EF-3'. ELECTRICAL CONTRACTOR TOCOORDINATE EXACT LOCATION WITH MECHANICALCONTRACTOR. UNIT WILL HAVE FACTORY INTEGRALDISCONNECT WITH CONSTANT ON FOR CONTROL. MAKEFINAL CONNECTIONS.

10. NEW 'CU-1'. COORDINATE WITH MECHANICAL CONTRACTOREXACT LOCATION. PROVIDE NEMA 3R DISCONNECT. VERIFYWITH MANUFACTURES INSTALLATION GUIDELINES FORCORRECT ELECTRICAL CONFIGURATIONS. MAKE FINALCONNECTIONS.

11. PROVIDE NEW WEATHERPROOF/GFCI ROOF TOPRECEPTACLE. MAKE FINAL CONNECTIONS.

12. EXISTING FIRE ALARM CONTROL PANEL.

13. LOCATION OF NEW ELECTRICAL PANEL 'K1'. SEE ONE LINEON SHEET E-701 FOR MORE INFORMATION. CONTRACTORSHALL PROVIDE 2" WIDE BLACK AND WHITE STRIPE TAPE ONFLOOR IN FRONT OF PANEL TO MAINTAIN WORKSPACECLEARANCE. (30"W X 36"D) PROVIDE WARNING SIGN:"WARNING - OSHA REGULATION - AREA IN FRONT OFELECTRICAL EQUIPMENT MUST BE KEPT CLEAR FOR 36INCHES".

14. NEW 'CU-2'. 'CU-2' PROVIDES POWER TO 'HC-2'. COORDINATEWITH MECHANICAL CONTRACTOR EXACT LOCATION.PROVIDE NEMA 3R DISCONNECT. VERIFY WITHMANUFACTURES INSTALLATION GUIDELINES FOR CORRECTELECTRICAL CONFIGURATIONS. MAKE FINAL CONNECTIONS.

15. NEW 'HC-1'. COORDINATE WITH MECHANICAL CONTRACTOREXACT LOCATION. PROVIDE DISCONNECT. VERIFY WITHMANUFACTURES INSTALLATION GUIDELINES FOR CORRECTELECTRICAL CONFIGURATIONS. MAKE FINAL CONNECTIONS.

01/4"=1'-0" 2' 4' 8'1 FLOOR PLAN - ELECTRICAL

GENERAL NOTES:

A. CONTRACTOR SHALL COORDINATE THE LOCATION TO STORE THE EQUIPMENT DURINGCONSTRUCTION AND SECURE TRANSPORTATION OF EQUIPMENT IF NEEDED. THE OWNERWILL CONFIRM THE CONDITION OF THE EQUIPMENT UPON DELIVERY. ONCE THE EQUIPMENTIS PLACED IN ITS TEMPORARY STORAGE LOCATION, THE CONTRACTOR IS RESPONSIBLE FORPROTECTING THE PACKAGED EQUIPMENT AND THE TRANSPORTATION BACK TO SPACE.

B. CONTRACTOR IS RESPONSIBLE FOR UNPACKING, MOVING AND LEVELING THE EQUIPMENT TOTHE FINAL LOCATIONS. AN OWNERS REPRESENTATIVE WILL BE ON SITE AT THIS TIME TOCOORDINATE THE PLACEMENT/INSTALLATION OF THE EQUIPMENT.

C. CONTRACTOR IS RESPONSIBLE FOR THE ELECTRICAL ROUGH-IN WORK ASSOCIATED WITHEACH PIECE OF EQUIPMENT.

D. UNLESS NOTED OTHERWISE, THE CONTRACTOR IS RESPONSIBLE FOR THE FINALELECTRICAL CONNECTIONS ASSOCIATED WITH THE EQUIPMENT.

E. CONTRACTOR SHALL VERIFY WITH OWNERS REPRESENTATIVE ALL RECEPTACLE MOUNTINGHEIGHTS AND EXACT LOCATIONS FOR EACH PIECE OF EQUIPMENT PRIOR TO ROUGH-IN.

F. ALL COVER PLATES SHALL BE STAINLESS STEEL.

G. ALL FLEXIBLE CONDUIT SHALL BE "SEALTITE" OR EQUAL. FLEXIBLE METAL CONDUIT IS NOTACCEPTABLE.

H. CONTRACTOR IS TO COORDINATE THEIR INSTALLATION WITH THE OTHER SYSTEMS BEINGINSTALLED. IF A CONFLICT OCCURS AND IT IS DUE TO THE CONTRACTOR'S LACK OFCOORDINATION, ALL WORK INVOLVED IN RESOLVING THE CONFLICT WILL BE AT THEEXPENSE OF THE CONTRACTOR.

I. SOME EQUIPMENT WILL NEED GFCI PROTECTION AT THE BREAKER. SEE PANEL SCHEDULES.

GFCIDR1

E23E22

E5E4

J

E3

JE10

J E20

JE17

E12GFCI

DR2

E18

DR1

GFCI

E16

GFCI

E15 DR1

GFCI

GFCIDR2

GFCIDR2

11

N

'A' 'AA'

'MDP'

(R)

2

E13

J E2DE2B J

E2CJJ4

5

K1-19

'F-1'

'S-1'

'EF-1'

6E2A K1-1,3,5

K1-11

7

3

GFCI

K1-27

K1-27

K1-29

DR1K1-29

K1-31

K1-33

K1-35

MDP-5

8

XX

EQUIPMENT NOTE:

REFER TO EQUIPMENT SCHEDULE ON SHEET E-501 FOR MOREINFORMATION.

J'EF-3'

K1-32

3

3

9

WP

12

S

'K1'13

W

3

GFCIDR1K1-29

10

CU-2

CU-1

14

15

RTU-5HC-2

HC-1

AA-20

WP

11AA-22

AA-22

AA-28,30

AA-20

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

KEY PLAN

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

FLO

OR

PLA

N -

ELEC

TRIC

AL

E-201

Page 26: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

ITEM

10.0

HOBERT LXeH

MANUFACTURER ANDDESCRIPTION AMPS

'F-1' - FURNACE

DISHWASHER UNDERCOUNTER

PANEL/CONNECTIONV-PH

HW = HARDWIRED FROM JUNCTION BOXALL STANDARD NEMA 5-20R RECEPTACLES ARE TO BE GFCI TYPE WITHIN FOOD SERVICE AREA.1. REFER TO ARCHITECTURAL ELEVATIONS FOR DEVICE LOCATIONS.2. RECEPTACLES TO BE NEMA 5-20R UNLESS OTHERWISE NOTED.

NOTES

K1-7

REACH-IN FREEZER 9.6120V-1 PLUG K1-8

EQUIPMENT SCHEDULE

40.0208V-1 K1-13,15

EXISTINGMICROWAVE 24.0208V-1 PLUG K1-28,30

HEATED HOLDING CABINET EXISTING PROVIDE GFCI BREAKER IN PANEL 'K1'120V-1 PLUG K1-1616.0

EXISTINGMILK COOLER 120V-1 PLUG8.9

ICE MAKER/DISPENSER 120V-1 11.9

SOUTHBEND 4361DRANGE 120V-1 HW5.9

SALVAJOR S914WASTE COLLECTOR 208V-3 HW3.5

BY OWNERCLOTHES WASHER PLUG16.0

BY OWNERCLOTHES DRYER 208V-1 PLUG24.0

WALL RECEPTACLE - 120V-1 -16.0 K1-27

- 120V-1 K1-3116.0

SOUTHBEND GB/15SCCONVECTION OVEN 120V-1 PLUG K1-98.9

MODEL NUMBER

3. SOME CIRCUITS MAY REQUIRE GFCI BREAKER AT THE PANEL, VERIFY WITH PANEL SCHEDULE.

HOOD CANOPY MASTER AIR 120V-1 16.0 K1-11

'S-1' - SUPPLY FAN MASTER AIR

MOUNT GFCI RECEPTACLE ABOVE COUNTER

REACH-IN REFRIGERATOR 120V-1 16.0

TRUE T-49F-HC

K1-10

'EF-1' - EXHAUST FAN MASTER AIR

SERVING COUNTER

E2A

E2B

E2C

E2D

E3

E4

E5

E10

E12

E13

E15

E16

E17

E18

E20

E22

E23

DR1

DR2

HW

HW

HW

HW

208V-3

208V-3

120V-1

EXISTING PLUG

HW

K1-1,3,5

PROVIDE GFCI BREAKER IN PANEL 'K1'

PROVIDE SHUNT-TRIP BREAKER IN PANEL 'K1'

PROVIDE GFCI BREAKER IN PANEL 'K1'

PROVIDE GFCI BREAKER IN PANEL 'K1'

PROVIDE GFCI BREAKER IN PANEL 'K1'

PROVIDE GFCI BREAKER IN PANEL 'K1'

PROVIDE GFCI BREAKER IN PANEL 'K1'

208V-1 PLUG K1-18,2016.0

K1-16

3.5

4.6

K1-29

WALL RECEPTACLE -

- 120V-1 K1-3316.0 MOUNT GFCI RECEPTACLE ABOVE COUNTERDR2 WALL RECEPTACLE -

- 120V-1 K1-3516.0 MOUNT GFCI RECEPTACLE ABOVE COUNTERDR2 WALL RECEPTACLE -

WALL RECEPTACLE - 120V-1 16.0DR1

K1-37,39

K1-25120V-1

K1-22,24,26

K1-21

K1-23

MOUNTINGHEIGHT

-

-

-

-

-

36" AFF.

90" AFF.

90" AFF.

48" AFF.

48" AFF.

16" AFF.

16" AFF.

16" AFF.

16" AFF.

48" AFF.

48" AFF.

48" AFF.

36" AFF.

36" AFF.

16" AFF.

-

MASTER AIR

PROVIDE SHUNT-TRIP BREAKER IN PANEL 'K1'

K1-1,3,5

POWER FED FROM MOTOR STARTER PANEL

POWER FED FROM MOTOR STARTER PANEL

GFCI RECEPTACLE

GFCI RECEPTACLE

24" AFF.

16" AFF.

HW

PROVIDE SHUNT-TRIP BREAKER IN PANEL 'K1'

4. CONTRACTOR SHALL REFER TO FOOD SERVICE EQUIPMENT DRAWINGS FOR EQUIPMENT WIRING REQUIREMENTS PRIOR TO ROUGH-IN.

1'-6"

4'-0"

4'-8"

6'-8"

COMMUNICATIONS OUTLET

RECEPTACLE, UNLESS NOTED OTHERWISE

LIGHT SWITCH

THERMOSTAT

FIRE ALARMPULL STATION

FIRE ALARM HORN/STROBEFIRE ALARM STROBE

NTS2 DETAIL - TYPICAL DEVICE MOUNTING HEIGHT

3'-6"

WALL PHONE

NTS1 DETAIL - OCCUPANCY SENSOR WIRING DIAGRAM

+24VDC

CONTROL OUTPUT

COMMON

+24VDC

NEUTRAL

HOT

RED

BLACK PACK

BLAC

K

BLUE

WHITE

POWERRED

RED

AD

OL

CONTROL OUTPUT

COMMON

ANY 24VDCCEILING/WALLSENSOR

ANY 24VDCCEILING/WALLSENSOR

DETAIL CODED NOTES :

1. ADDITIONAL SENSORS MAY OR MAY NOT BE PRESENT ON EVERY CIRCUIT. VERIFY EXACTQUANTITY OF SENSORS NEEDED WITH PLANS.

2. LINE VOLTAGE TOGGLE SWITCH, IF INDICATED IN ROOM. NOT ALL CIRCUITS MAY HAVE THIS.

1

2

CIRCUIT

BY OWNER

BY OWNER

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

SCH

EDU

LES

- ELE

CTR

ICAL

E-501

Page 27: ADVENTURE CENTRAL -KITCHEN MODIFICATIONS & UPGRADES · q-101 food service equipment plan q-102 food service equipment mechanical and electrical plans q-103 food service equipment

SCALE:1 ONE-LINE DIAGRAMNONE

(EXISTING) MAIN DISTRIBUTION PANEL 'MDP', 600A BUS, 208Y/120V, 3PH, 4W

60A

MCTEXISTING PAD MOUNT

TRANSFORMER

TVSS

100/3

600A

1

600/3

(EXISTING)

CODED NOTES:

1. PROVIDE NEW 200A FUSE IN EXISTING "SPARE" BREAKER.FUSE SHALL MATCH EXISTING PANEL TYPE FUSING.

2. PROVIDE INTERNAL SURGE PROTECTION DEVICE ('SPD') INNEW PANEL 'K1'.

3. REMOVE EXISTING RANGE FEEDER AND CONDUIT BACK TOPANEL.

4. PROVIDE NEW 40A FUSE IN EXISTING 100A BREAKER FORNEW 'RTU-5'. FUSE SHALL MATCH EXISTING PANEL TYPEFUSING.

5. PROVIDE NEW 60A FUSIBLE DISCONNECT NEMA 3R, WITH 40AFUSE FOR 'RTU-5'. CONTRACTOR TO MAKE FINALCONNECTIONS.

2

RANGE

100/3

60A

100/3

70A

100/3

RTU-2 RTU-3

30A

100/3

CU1

SPARE200/3

100A

100/3

RTU-4 PNL'B'

200A

200/3

(EXISTING)(EXISTING)

(EXISTING) (EXISTING)(EXISTING) (EXISTING)

TVSS

PNL 'K1'200A

(NEW)

200A(NEW)

1

(EXISTING)

3

RTU-5(NEW)

4

40A(NEW)

3 4 5 6 7 8 9

PNL'A'

(EXISTING)

PNL'AA'

10

200A

200/3SPARE200/3

(EXISTING)

60AF40AF

5

SPD

2

TAG PURPOSE

20A3 1 3-12 AWG - 12 AWG - 3/4"

30A3 3-10 AWG - 10 AWG - 3/4"

40A3 3-8 AWG - 10 AWG - 3/4"

50A3 3-6 AWG - 10 AWG - 3/4"

70A3 3-4 AWG - 8 AWG - 1"

90A3 3-2 AWG - 8 AWG - 1-1/4"

110A3 3-1 AWG - 6 AWG - 1-1/4"

150A3 3-1/0 AWG - 6 AWG - 1-1/2"

175A3 3-2/0 AWG - 6 AWG - 1-1/2"

200A3 3-3/0 AWG - 6 AWG - 2"

225A3 3-4/0 AWG - 4 AWG - 2"

250A3 - 4 AWG - 2"

1

1

1

1

1

1

1

1

1

1

1 3-250 KCMIL

3 PHASEEQUIPMENT

ANDMOTOR

FEEDERS

CONDUITSIZE PER

SET

ISOLATEDGND.SIZE(IF REQ.)

GROUNDSIZE

NEUTRALWIRE

QUANTITY -SIZE

PHASEWIRES

QUANTITY -SIZE

# OFSETS

Notes:1)

2)3)

4)

NOT ALL SIZES SHOWN ARE USED

AMPACITY SHOWN IS THE NOMINAL REQUIRED FOR CONDUCTORS INDICATED. CONDUCTORS WITH HIGHERCURRENT RATINGS MAY BE SHOWN ON THE DRAWINGS TO ACCOUNT FOR VOLTAGE DROP OR FOR FUTUREEXPANSION.

CONDUIT SIZES SHOWN ARE BASED ON EMT TYPE, AND CONDUCTORS WITH THHN, THWN, OR XHHWINSULATION. CONTRACT SHALL COMPLY WITH NEC FILL RATIOS IF ANY OTHER TYPE COMBINATIONS AREUSED.

IF CONDUIT OR CONDUCTOR SIZES ARE NOT INDICATED, SELECT FROM THE FEEDER SCHEDULE TABLEABOVE.

200A5

40A3

SCALE:2 FEEDER SCHEDULENONE

3" (TYP.)

2" (T

YP.)

LINE #1

LINE #2

LINE #3

(TYPICAL FOR ALL NAMEPLATES)

BRANCH PANELBOARD NAMEPLATE

VOLTAGE, PHASE, WIRES

PANEL SOURCE

PANEL DESIGNATION

GENERAL NAMEPLATE DETAIL

LINE #3

LINE #2

LINE #1

MINI

MUM

MINIMUM

STANDARD COLORS:

ELECTRICAL EQUIPMENT SUCH AS:1. PANELBOARDS, MOTOR STARTERS, MOTOR CONTROL CENTERS, DISTRIBUTION PANELS, SWITCHBOARDS, DISCONNECTSWITCHES (IF APPLICABLE)

A. 208Y/120 VOLTS (NORMAL) - GREEN BACKGROUND, WHITE LETTERSB. 480Y/277 VOLTS (NORMAL) - BLACK BACKGROUND, WHITE LETTERSC. 208Y/120 VOLTS (EMERGENCY) - WHITE BACKGROUND, RED LETTERSD. 480Y/277 VOLTS (EMERGENCY) - RED BACKGROUND, WHITE LETTERS

NAMEPLATE COLOR CODING AND VERBIAGE SHALL BE REVIEWED IN DETAIL WITH THE OWNER PRIOR TO FABRICATION.

ENGRAVED MICARTA WITH 3/8" HIGH LETTERS. REFERTO COLOR CHART FOR LETTER AND BACKGROUNDCOLORS. INSTALL CENTERED, AT TOP OF FRONT FACEFOR ALL BRANCH PANELBOARDS, SWITCHBOARDS,DISTRIBUTION PANELS, MCC'S, TRANSFORMERS, SAFETYAND DISCONNECT SWITCHES, AND MOTOR STARTERS.INSTALL ADJACENT TO ASSOCIATED BRANCH DEVICEFOR SWITCHBOARD AND DISTRIBUTION PANELS.

SELF-TAPPING SCREW (TYP.)

SCALE:3 IDENTIFICATION TAG DETAILSNONE

100A5 1 3-1/0 AWG 8 AWG 8 AWG 2"200A5 1 6 AWG 6 AWG 2-1/2"

225A5 4 AWG 4 AWG 3"250A5 4 AWG 4 AWG 3-1/2"

1

1

3-250 KCMIL

3-300 KCMIL

3-400 KCMIL 2-400 KCMIL

2-300 KCMIL

2-250 KCMIL

2-1/0 AWG POWER PANELS,DISTRIBUTION

PANELBOARDS,AND

SWITCHBOARDS

141

Wes

t Cen

tral A

ve. /

/ #21

// W

inte

r Hav

en, F

L 33

880

Pho

ne: 6

15.2

54.1

500

// Fa

x:61

5.25

5.65

72

© Copyright 2019, Barge Design Solutions, Inc. ALL RIGHTS RESERVED

Tim

e / D

ate:

FILE NO.

File

:D

raw

ing:

RE

VIS

ION

INFO

RM

ATI

ON

2/28

/201

9 1:

54:3

6 P

MC

:\Use

rs\T

JFin

ney\

Doc

umen

ts\A

DV

CE

N_A

C_v

18_t

im.fi

nney

.rvt

FIV

E R

IVE

RS

ME

TRO

PA

RK

S

3695800

AD

VE

NTU

RE

CE

NTR

AL

- KIT

CH

EN

MO

DIF

ICA

TIO

NS

& U

PG

RA

DE

S

A-1

01,

FIR

ST

FLO

OR

PLA

N

2222

JAM

ES H

. MC

GEE

BLV

D -

DAY

TON

, OH

IO

RE

V.

DR

CH

KD

ATE

:D

ES

CR

IPTI

ON

:

6/05/2019

ON

ELIN

E - E

LEC

TRIC

AL

E-701