advances in ribbon flow technology - pma · advances in ribbon flow® technology audrey r. emanuel...
TRANSCRIPT
![Page 1: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/1.jpg)
Advances in Ribbon Flow® Technology
Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®
![Page 2: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/2.jpg)
What Is Ribbon Flow? A Process and system for the application of
polyurethane elastomers to rolls or other cylindrical objects without the
need for a mold.
![Page 3: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/3.jpg)
Outline
• Advantages of Ribbon Flow versus Hot Cast
• Types of Standard Ribbon Flow • Improved Ribbon Flow Systems
• Improved physical and dynamic properties
• Advances in application method (One-Pass) and machine requirements to process new systems properly
![Page 4: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/4.jpg)
Advantages of Ribbon Flow® versus Hot Cast
• No molds required • Reduced Waste • Lower Energy and Labor Costs • Shorter turnaround times
![Page 5: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/5.jpg)
Types of Ribbon Flow® Available
• High Performance Polyethers • High Durometer System (RFA 1000) • High Durometer Systems with LONZACURE
• (improved dynamics) • Low Durometer System (RFA 1001)
• Polyester One-Pass System (RFA 1004)
• Polyether One-Pass System (RFA 1100) • (improved properties and dynamics)
![Page 6: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/6.jpg)
Ribbon Flow® Systems High Performance-High Durometer Ethers
• Multi-pass • 95A-66D available durometers • Excellent mechanical and dynamic
properties • Good hydrolytic stability • Mix Ratio range 100:35 to 100:57 • 20-35 second pot life at 35ºC
![Page 7: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/7.jpg)
Ribbon Flow® Systems Superior Dynamic Performance Ethers
• Multi-pass • 90A-70D Available Durometers • Improved dynamics and hydrolytic
stability • Reduced Thermoplasticity • Mix Ratio range from 100:39 to 100:61 • 15-25 second pot life at 30ºC
![Page 8: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/8.jpg)
Ribbon Flow® Systems High Performance-Low Durometer Ethers
• Multi-pass or Single-pass (60A-95A) available durometer • Catalyst needed for one-pass • Excellent Mechanical and Dynamic Properties • Good Hydrolytic stability • Mix Ratio range from 100:18 to 100:44 • Pot life 23-35 seconds at 35ºC
![Page 9: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/9.jpg)
Why Single-Pass over Multi-Pass?
• Improved properties – One prepolymer, two curatives (hard
and soft), and optionally a catalyst • Turnaround times • No worries about grinding between
layers
![Page 10: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/10.jpg)
Improved Ribbon Flow® Systems and Application
Overview
• Uses a ‘stream die’ for thick layers in one pass
• 5-6 second gel times • Uses a 3 to 4 component machine
with special requirements for processing
![Page 11: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/11.jpg)
New Ribbon Flow® Systems Ether One-Pass
• 60 A to 95A available durometers • Short pot life (5-6 seconds) at 35ºC • Improved dynamic and physical
properties • One-pass application only • Mix ratio range from 100:27 to 100:140
![Page 12: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/12.jpg)
One Pass Ether System
Physical Properties
RFA 1100 RFB 1160 1195 DUROMETER 60A 94A 100% MOD,psi 350 1350 300% MOD,psi 670 2520 TENSILE, psi 3060 4590 ELONGATION, % 670 500 Trouser Tear, pli 28 200 Die C Tear, pli 200 670
![Page 13: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/13.jpg)
One Pass Ether System
Dynamic Properties
0.0000
0.0200
0.0400
0.0600
0.0800
0.1000
0.1200
30 50 70 90 110
130
150
170
190
210
230
Temperature, C
Tan
Del
ta
Tan(d) - RFB1090
Tan(d) - New RF ether
Tan(d) L100/E300
![Page 14: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/14.jpg)
New Ribbon® Flow Systems Ester One-Pass
• 70 A to 55D available durometers • Short pot life (5-6 seconds) at 60ºC • Improved cut/tear, abrasion
resistance, and solvent resistance versus ether materials
• One-pass application only • Mix ratio range from 100:46 to
100:135
![Page 15: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/15.jpg)
One Pass Ester Physical Properties
RFA 1004 RFB 4155 4171 DUROMETER 55D 70A 100% MOD,psi 1900 325 300% MOD,psi 6600 550 TENSILE, psi 7300 5250 ELONGATION, % 305 640 Trouser Tear, pli 150 85
![Page 16: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/16.jpg)
Ribbon Flow® Single-Pass General
Material Characteristics
• Very short pot life, short dwell times in the mix chamber
• Higher viscosities, higher pressures • Higher flow-rates compared to
multi-pass • Applied through a ‘stream die’
![Page 17: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/17.jpg)
New ‘Stream Die’ for Ribbon Flow®
• Ability to apply thick layers of urethane, up to one inch, in a single-pass – Eliminates chances for interlayer
delamination • Requires a high quality mix machine with
ability to handle very short pour lives and high mix head pressure
• Tested in 50, 75, and 100mm sizes • Crompton patent applied for
![Page 18: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/18.jpg)
Ribbon Flow® ‘Stream Die’
![Page 19: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/19.jpg)
Processing with the ‘Stream Die’
• Roll size and material output must be consistent with the machine capability
• Machine output and desired thickness determines the die size and traverse rate
• Adjusting RPM is necessary to avoid dripping (RPM too low) or ‘roping’ (RPM too high) of the material.
![Page 20: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/20.jpg)
Ribbon Flow® ‘Stream Die’
![Page 21: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/21.jpg)
100 mm ‘Stream Die’
![Page 22: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/22.jpg)
Mixing Requirements
• Size of the mixing chamber (volume) • Moderate to high shear (rotor/stator) • Minimum of about 7500-8500 RPM
for good mix
![Page 23: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/23.jpg)
Mix Chamber for Ribbon Flow®
![Page 24: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/24.jpg)
Mix Chamber for Ribbon Flow®
![Page 25: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/25.jpg)
Further Machine Recommendations
• Recirculating • Metered lines (mass flow) • Stainless Steel • Moderate heat on tanks and lines, 1000 psi
lines • Ability to handle 5,000-10,000 cps • Automatic flush system with no delay • Computer recipe memory • Adjustable set points “on the fly”
![Page 26: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/26.jpg)
Challenges of Single-Pass Ribbon Flow®
• Processing can be an art • Initially more time and effort required • Best used for a significant volume of
rolls • Machine limitations • No interlayer adhesion without a rough,
ground surface first
![Page 27: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/27.jpg)
Single-Pass Ether and Ester Ribbon Flow®
![Page 28: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/28.jpg)
Single-Pass Ester RFA 1004 RFB 4155/RFB4171
![Page 29: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/29.jpg)
Summary • There are many advantages to using
Ribbon Flow over hot cast, especially single-pass, if the right circumstances exist.
• Various systems to choose from depending on need.
• Advances in application and processing offer advantages over conventional Ribbon Flow systems.
• Special consideration must be given when choosing a suitable machine to run single-pass Ribbon Flow.
![Page 30: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/30.jpg)
RF One-Pass Video Clip
![Page 31: Advances in Ribbon Flow Technology - PMA · Advances in Ribbon Flow® Technology Audrey R. Emanuel Crompton Corporation Adiprene®/Vibrathane®](https://reader034.vdocuments.us/reader034/viewer/2022051601/5ae1a7a07f8b9a5b348b544c/html5/thumbnails/31.jpg)
Special Thanks to the Following For Their Contributions:
Charles Mallon Tom Peter
Vince Gajewski Donna Day