Page 1: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

ATTACHMENT (10)

Non-Proprietary -- Design Report No. B-PENG-DR-005, Revision 02,

"Addendum to CENC-1179 Analytical Report for

BGE CCNPP Units 1 and 2 - Piping"

Calvert Cliffs Nuclear Power Plant, Inc. March 14, 2001

Page 2: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3 Report: 12 pages

Appendices: 153 pages

Other Attachments: none

DESIGN REPORT NO. B-PENG-DR-005, Rev. 02

Addendum to CENC- 1179

Analytical Report for

Baltimore Gas & Electric Calvert Cliffs Station

Units No. I and II

Piping

WESTINGHOUSE ELECTRIC COMPANY

CE NUCLEAR POWER LLC

WINDSOR, CONNECTICUT

This document is the property of CE Nuclear Power LLC (CE) Windsor, Connecticut, and is to be used only for the purposes of the agreement with CE pursuant to which it is furnished.

VERIFICATION STATUS: COMPLETE

Authored by:

Approved by:

B. Nadgor, Cognizant Engineer

C. R. Schmidt, Independent Reviewer

Approved by: /!°/(nC (t 1 K. H. Haslingcr, Task Manager

Date: 1Pc C'10

Date: Z/2/ 0/0

"Date: 1/2• !0 /'7"/6w

It is hereby certified this report is in compliance with the requirements of the ASME Boiler and Pressure Vessel Code, Section 111, 1989 Edition, no Addenda.

Registration _No+' _ _________

State of Connecticut Date 12 2/ ouj

Page 3: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 2 of 12

Contingencies and Assumptions

Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and Electric Calvert Cliffs Station Units No. I and II Piping

Document Number:

Project Manager:

Project Number:

B-PENG-DR-005 Revision Number:

John. T. McGarry

2009335

Instructions: A copy of this form shall be sent to the cognizant Project Manager who shall be responsible for assuring that Internal Contingencies and Assumptions are cleared and External Contingencies and Assumptions are transmitted to the customer.

Type of Contingency/Assumption Contingency/Assumption

Z None There are neither Internal nor External Contingencies or Assumptions in this Design Analysis.

0

02

Page 4: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENCG-DR-005, Rev. 02 Page 3 of 12

RECORD OF REVISIONS

Rev Date Pages Changed Prepared By Reviewed By Approved By

00 01/05/00 Original B. Nadgor C. L. Mendrala K. H. Haslinger

01 03/01/00 Pages 1 -4, 6, B. Nadgor T. D. Hammel K. H. Haslinger

A37, B13, B41,

B42

Only those pages

changed in this

revision show

Revision 01 in

the header

02 12V/100 Pages 1-6, 8-11, B. Nadgor C. R. Schmidt K. H. Haslinger

A2, A3, A5, A8,

A10-A14, A16,

A17, A20, A21,

A29-A36, A38

A41, B18,/B40,

Replaced

Attachment D

0

Page 5: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

O B-PENG-DR-005, Rev. 02 Page 4 of 12

ABSTRACT

The Baltimore Gas and Electric Calvert Cliffs Station Units I and II, Mechanical Nozzle Seal

Assemblies (MNSA), to be installed on the Hot Leg RTD, PDT and Sampling Nozzles, are designed

and fabricated to satisfy the requirements of the ASME Code, Section III.

The components of each MNSA replace the pressure boundary previously assumed to be the J-weld

connecting the nozzle to the pipe. Four holes are required in the Hot Leg for the installation of each

MNSA assembly. The impact of these holes on the design basis of the RCS Hot Leg is also

examined in this design report.

These components are analyzed in accordance with:

1. Engineering Specification No. 8067-31-5, Rev. 15.

2. Design Specification No. SP-0846, Rev. 00.

3. ASME Boiler and Pressure Vessel Code, Section III, 1989 Edition, no Addenda.

The acceptability of the design is established by the results of the detailed structural and thermal

analyses contained in this report.

Revision 01 is performed to clear the internal contingencies contained in Revision 00 of this

document and to incorporate the latest revisions of the drawings.

Revision 02 is performed to incorporate the design changes of the actual MNSA installed on the Hot

Leg RTD nozzle. Also, one typo was corrected in the analysis of PDT/Sampling MNSA.

Page 6: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 5 of 12

TABLE OF CONTENTS

SECTION

ABSTRACT

1.0

2.0

2.1

2.2

2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5

2.3.6

3.0

PAGE

4

INTRODUCTION

SIGNIFICANT RESULTS

Hot Leg RTD Nozzle MNSA

Hot Leg PDT/Sampling Nozzle MNSA

MNSAs in Hot Leg Piping Maximum Allowable Bolt Load and Minimum Allowable Length of Bolt Engagement Area of Reinforcement Requirements for Nozzle Penetration Primary plus Secondary Stress Intensity Range Fatigue Usage Factor Primary plus Secondary Stress Intensity Range and Fatigue Evaluation of Modified RTED and PDT/Sampling Nozzles Maximum Allowable Shear Load in the Grooved Section of the RTD and PDT/Sampling Nozzles

REFERENCES

LIST OF ATTACHMENTS

A Analysis of BG&E Units I and II Hot Leg RTD Nozzle MNSA

B Analysis of BG&E Units I and II Hot Leg PDT/Sampling Nozzle MNSA

C ANSYS Evaluation of Top Plate

D CALCULATION A-CCNPP-9449-1230, Rev. 01, "Evaluation of Attachment Locations for Mechanical Nozzle Repair Devices on Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant Units 1 and 2 Hot Leg Piping RTD and POT/Sampling Instrument Nozzles"

E Quality Assurance Forms

0

6

7

8

9

10 10 10 10 II

11

12

Page 7: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENIG-DR-005, Rev. 02 Page 6 of 12

1.0 INTRODUCTION

This design report summarizes the analyses performed for the installation of Mechanical

Nozzle Seal Assemblies (MNSA) on three Hot Leg nozzles. The MNSA is a mechanical

device that acts as a complete replacement of the "J" weld between an Inconel 600

instrument nozzle and the Hot Leg pipe. Its function is to prevent leakage and to restrain the

nozzle from ejecting in the event of a through-wall crack or weld failure of a nozzle. The

potential for these events exists due to Primary Water Stress Corrosion Cracking.

The components of the MNSA, as well as the impact of the MNSA installation on the Hot

Leg piping, are analyzed in accordance with the ASME Code, Section III, 1989 Edition, no

Addenda (Reference 3.4).

Revision 01 is performed to clear the internal contingencies contained in Revision 00 of this

document. It also incorporates the latest revisions of the MNSA drawings.

Revision 02 is performed to incorporate the design changes of the actual MNSA installed on

the Hot Leg RTD nozzle. Also, one typo was corrected in the analysis of PDT/Sampling

MNSA.

Page 8: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 7 of 12

2.0 SIGNIFICANT RESULTS

Reference 3.5 defines the current design basis documents for the RCS Piping.

The only Baltimore Gas and Bectric Calvert Cliffs Station Units I and II piping design report

affected by this addendum is CENC-1 179. The list of design report addenda below remain

applicable to the RCS Piping and are not modified by this addendum.

CENC-1 515 604590-MPS-5DSR-006, Rev. 00 B-MECH-DR-001, Rev. 00 B-MECH-DR-004, Rev. 00 B-MECH-DR-005, Rev. 00 B-MECH-DR-008, Rev. 00 B-MECH-DR-009, Rev. 00

(04/82) (08/90) (07/92) (08/93) (06/93) (11/93) (11/93)

The results of this design report are in accordance with the ASME Boiler and Pressure

Vessel Code, Section III allowables (Reference 3.4).

0

Page 9: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page 8 of 12

2.1 Hot Leg RTD Nozzle MNSA

Attachment A contains the detailed analysis of the Hot Leg RTD Nozzle MNSA components. The following table summarizes the results for the Hot Leg RTD Nozzle MNSA components. The existing design analysis for the Hot Leg RTD Nozzle is not affected by the addition of

the MNSA.

Page 10: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 9 of 12

2.2 Hot Leg PDT/Sampling Nozzle MNSA

Attachment B contains the detailed analysis of the Hot Leg PDT and Sampling Nozzle MNSA components. The following table summarizes the results for the Hot Leg PDT/Sampling Nozzle MNSA components. The existing design analysis for the Hot Leg PDT/Sampling nozzles is not affected by the addition of the MNSA.

0

Page 11: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 10 of 12

2.3 MNSAs in Hot Leg Piping

Attachment D contains the detailed evaluation of the attachment locations for the RTD MNSA and the POT/Sampling MNSA, and stress analysis considering a modification in the RTD (Rev. 02 of the report) and PDT/Sampling nozzles on the nozzle outside surface. The results of this evaluation are shown below:

2.3.1 Maximum Allowable Bolt Load and Minimum Allowable Length of Bolt Engagement

2.3.2 Area of Reinforcement Requirements for Nozzle Penetration

2.3.3 Primary plus Secondary Stress Intensity Range

L

AV0

Page 12: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 11 of 12

Fatigue Usage Factor

-12.3.5 Primary plus Secondary Stress Intensity Range and Fatigue Evaluation of

Modified RTD and PDT/Sampling Nozzles [ 2.3.6 Maximum Allowable Shear Load in the Grooved Section of the RTD and

PDT/Sampling Nozzles

02.3.4

I

Page 13: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page 12 of 12

3.0 REFERENCES

3.1 "Analytical Report for Baltimore Gas & Electric Calvert Cliffs Station Unitsl and II

Piping," Report No. CENC-1179, March 1972.

3.2 "Mechanical Nozzle Repair Device", BGE Design Specification No. SP-0846, Rev. 00.

3.3 "Engineering Specification for Reactor Coolant Pipe and Fittings for Baltimore Gas and Electric Company", Specification No. 8067-31-5, Revision 15.

3.4 American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, 1989 Edition (No Addenda).

3.5 ABB CENP Letter No. B-PENG-00-001, "Design Input for the MNSA Evaluations, Project No. 2009335", January 2000.

Page 14: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

B-PENG-DR-005, Rev. 02 Page Al of A42

PaeA o 4

ATTACHMENT A

ANALYSIS OF BG&E UNITS I AND II HOT LEG RTD NOZZLE MNSA

0

Page 15: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A2 of A42

TABLE OF CONTENTS Section

Page No.

1. INTRODUCTION 4

1.1 Objective 4

1.2 Assessment of Significant Design Changes 4

2. DESIGN INPUTS 5

2.1 Selection of Design Inputs 5 2.1.1 Design and Operating Pressures and Temperatures 5 2.1.2 MNSA Materials 5 2.1.3 Nozzle Materials 5 2.1.4 Material Properties 5 2.1.5 MNSA Component Dimensions 8 2.1.6 Nozzle Dimensions 8

2.2 Assumptions 9 2.2.1 Loading Conditions 9 2.2.2 Consideration of Seismic Loads 9 2.2.3 Friction Force 9 2.2.4 Sealing pressure 10 2.2.5 Preload

10 2.2.6 Dimensions 10

3. ANALYSIS 11

3.1 MNSA Description 11

3.2 Consideration of Impact Load 12 3.2.1 Relative Displacements Due to Thermal Expansion 12 3.2.2 Soft Spring Package Setting vs. Calculated Displacements 13 3.2.3 Determination of Impact Force 14 3.2.4 Impact Force 17

3.3 Stresses in the RTD MNSA Components 18 3.3.1 Tie Rod

18 3.3.2 Hex Head Bolt 23 3.3.3 Top Plate

29 3.3.4 Compression Collar 30 3.3.5 Upper Flange 31 3.3.6 Clamp 31

3.4 Fatigue Analysis 35 3.4.1 Normal Operating Pressure Force 35 3.4.2 Tie Rods

35 3.4.3 Hex Head Bolt 37

Page 16: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A3 of A42

3.4.4 Hex Head Bolt - Clamp

3.5 Consideration of Hydrostatic Test Pressure Conditions

3.6 Consideration of Faulted Conditions

4. SUMMARY OF RESULTS

5. REFERENCES

DESCRIPTIONLIST OF FIGURES

PAGE

Hot Leg RTD MNSA ........................................................................................................... 11 U p p e r F la n g e ...................................................................................................................... 2 5 Compression Collar ............................................................................................................ 26

040

41

41

FIGURE

1 2 3

42

43

Page 17: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

o B-PENG-DR-005, Rev. 02 0 Page A4 of A42

1. INTRODUCTION

1.1 Objective

The objective of this calculation is to present the results of the evaluation of the Mechanical Nozzle Seal Assembly (MNSA) to be installed on the Hot Leg RTD nozzle at the Baltimore Gas & Electric Calvert Cliffs Station Units I and I1.

The MNSA is a mechanical device that acts as a complete replacement of the "J" weld between an Inconel 600 instrument nozzle and the Hot Leg pipe. Its function is to prevent leakage and restrain the nozzle from ejecting in the event of a through-wall crack or weld failure of a nozzle. The potential for these events exists due to Primary Water Stress Corrosion Cracking.

1.2 Assessment of Significant Design Changes

This report presents the detailed structural and thermal analyses required to substantiate the adequacy of the design of the BG&E, Calvert Cliffs Units I and II Mechanical Nozzle Seal Assembly as a replacement of the nozzle "J" weld. This analytical work encompasses the requirements set forth in Reference 5.1 and is performed in accordance with the requirements of the ABB CENO Quality Procedures Manual QPM-101 (Reference 5.2).

Addenda to the original Piping Design Report (Reference 5.3) were reviewed and it was determined that their results have no impact on the current analysis and also that the current analysis does not impact their results.

Page 18: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A5 of A42

2. DESIGN INPUTS

2.1 Selection of Design Inputs

2.1.1 Design and Operating Pressures and Temperatures

The Mechanical Nozzle Seal Assembly is considered a pressure-retaining component. The Design Pressure is 2500 psia and Design Temperature is 650 0F. Operating pressure and temperature are 2250 psia and 6040F, respectively. Ambient design temperature is 120OF (Reference 5.7).

2.1.2 MNSA Materials

MNSA materials are taken from Reference 5.8.

Item Compression Collar Lower Flange Upper Flange Top Plate Clamp Hex Head Bolt Hex Nut Tie Rod Hex Bolt - Clamp

Material SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-453, Grade 660 SA-453, Grade 660 SA-453, Grade 660 SA-453, Grade 660

2.1.3 Nozzle Materials

Hot Leg RTD Nozzle and fitting materials are taken from References 5.5, 5.12.

Item Nozzle Thermowell

Material B-166 SB-166

Reference 5.12 5.5

2.1.4 Material Properties

Material properties used in this analysis include coefficients of thermal expansion (c), moduli of elasticity (E), design stress intensity values (S,) and Yield Strength Values (S). These properties are presented below and are found in the Appendices of Reference 5.9.

0

Page 19: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A6 of A42

2.1.4.1 Coefficient of Linear Thermal Expansion, a

The following table presents the temperature-dependent coefficients of linear thermal expansion for various materials:

temperature SB-166 SA-479 Type 304 SA-453, Grade 660 (OF) (Alloy 600) (304 SS) (Alloy 660)

100 6.90 8.55 8.24 200 7.20 8.79 8.39 300 7.40 9.00 8.54 400 7.57 9.19 8.69 500 7.70 9.37 8.82 600 7.82 9.53 8.94 604 7.82* 9.54' 8.94* 650 7.88 9.61 9.00

by interpolation

All coefficients are Coefficient B values from Table 1-5.0, where Coefficient B is the mean coefficient of thermal expansion X 10- in./in./°F in going from 70°F to the indicated temperature.

2.1.4.2 Modulus of Elasticity, E

The following table presents the temperature-dependent 304 and SA-453, Grade 660:

temperature

(0F) 70

200 300

moduli of elasticity for SA-479 Type

E

28.*3 27.6

2#7. 0

400 26.5 500 25.8 600 25.3 604 25.3* 650 25.0* 700 24.8

* by interpolation

All moduli of elasticity values are from Table 1-6.0, where E = value given X 106 psi.

0

Page 20: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A7 of A42

2.1. 4.3 Design Stress Intensity Value, Sm

The following table presents the temperature-dependent design stress intensity values for various materials:

temperature SA-479, Type 304 SA-453, Grade 660 (OF) Sm Sm

100 20.0 28.3 200 20.0 27.6 300 20.0 27.3 400 18.7 27.2 500 17.5 27.1 600 16.4 27.0 650 16.2 26.9* 700 16.0 26.8

by interpolation

The design stress intensity values for SA-479 Type 304 are from Table I-1.2; and the design stress intensity values for SA-453, Grade 660 are from Table 1-1.3. All Sm values are given in ksi.

2.1.4.4 Yield Strength Value, Sy

The following table presents the temperature-dependent yield strength values for SA-479 Type 304:

The yield strength values for SA-479 Type 304 are from Table 1-2.2. All Sy values are given in ksi.

0

temperature SA-479, Type 304 (OF) SY

100 30.0 200 25.0 300 22.5 400 20.7 500 19.4 600 18.2 650 17.9 700 17.7

Page 21: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02

Page A8 of A42

2.1.5 MNSA Component Dimensions

L

2.1.6 Nozzle Dimensions

-0

FI

Page 22: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Ag of A42

2.2 Assumptions

2.2.1 Loading Conditions

2.2.2 Consideration of Seismic Loads

Because of the nature of the accelerations from seismic events, only the tie rods will be evaluated for the stress effects of the seismic event. The remaining MNSA components will not be significantly affected. Separate seismic tests on similar MNSA configuration were performed to demonstrate an adequate seal performance (see Reference 5.16).

2.2.3 Friction Force

The effects of any impact of the nozzle against the top plate are dependent upon certain assumptions regarding the determination of the ejection force acting on the nozzle.

In an "ideal" (and worst case) break scenario, the crack would be complete, instantaneous and oriented such that no base or weld metal could interfere with the motion of the nozzle. In this case, the only resistance offered to the nozzle motion would be provided by the attached piping and by the Grafoil seal.

K

Page 23: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Al0 of A42

2.2.4 Sealing pressure

2.2.5 Preload

Nominal values of tie rod/bolt preload are used in this analysis since maximum values of preload will not significantly increase corresponding preload stresses. (A check of the results indicate that use of the maximum preload values will result in stresses which will remain below, or will be on the order of, their respective allowables. Therefore, use of the nominal values is acceptable).

2.2.6 Dimensions

V

0

Page 24: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page All1 of A42

3. ANALYSIS

3.1 MNSA Description

The MNSA is a mechanical device that acts as a complete replacement of the "J" weld between an Inconel 600 instrument nozzle and the hot leg pipe. It replaces the sealing function of the weld using a Grafoil seal compressed at the nozzle outside diameter to the outer hot leg surface. The MNSA also replaces the weld structurally by means of threaded fasteners engaged in tapped holes in the outer hot leg surface, and a restraining plate held in place by threaded tie rods. This feature prevents the nozzle from ejecting from the hot leg, should the '"J weld fail or the nozzle develop a circumferential crack.

A sketch of the Hot Leg RTD MNSA is depicted in Figure 1 below.

FIGURE 1 Hot Leg RTD MNSA

a9

Page 25: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A12 of A42

3.2 Consideration of impact Load

3.2.1 Relative Displacements Due to Thermal Expansion

ai

Page 26: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B4PENG-DR-005, Rev. 02 Page Al13 of A42PaeA3o 4

ISoft Spring Package Setting vs. Calculated Displacements3.2.2

L

Page 27: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A14 of A42Page A14 of A42

3.2.3 Determination of Impact Force

0

Page 28: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Al15 of A42Page A15 of A42

3.

Page 29: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A16 of A42

K

K *1I

Page 30: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A17 of A42

3.2.4 Impact Force

0

Page 31: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page A18 of A42

3.3 Stresses in the RTD MNSA Components

The Design Loads for the various MNSA components will be a function of either bolt preload, the impact load, and/or thermal expansion loads, depending upon the effects of the source load upon a particular component.

3.3.1 Tie Rod

L

Page 32: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A19 of A42

Page 33: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A20 of A42

L

Page 34: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A21 of A42

Page 35: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A22 of A42

Page 36: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A23 of A42

3.3.2 Hex Head Bolt

Page 37: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A24 of A42

Page 38: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A25 of A42

PaeA2 f 4

Page 39: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A26 of A42

0O

L.. J

Page 40: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A27 of A42

Page 41: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A28 of A42

0

Page 42: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A29 of A42

3.3.3 Top Plate

K

L

I

Page 43: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A30 of A42

3.3.4 Compression Collar

L

0

Page 44: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A31 of A42

Page A31 of A42

3.3.5 Upper Range

3.3.6 Clamp

The nozzle clamp is designed to fit tight against the nozzle and to transmit any axial load uniformly into the MNSA top plate. The load transfer between the clamp and the nozzle occurs due to contact/shear at the engaged tooth of the nozzle/clamp design and does not rely on friction.

3.3.6.1 Hex Head Bolt - Clamp

i

0

Page 45: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page A32 of A42

I-

Page 46: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

O B-PENG-DR-005, Rev. 02 Page A33 of A42

4. '7

Page 47: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A34 of A42

Q -l

Page 48: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A35 of A42

3.4 Fatigue Analysis

The fatigue analysis of the components will conservatively consider loads which may exist on the components after weld or nozzle failure has occurred. Prior to failure, components will be subjected to loads due mainly to preload and thermal expansion. After failure, and assuming that the nozzle/clamp is free to move, certain components will be additionally stressed because of the internal pressure forcing the nozzle/clamp up against the top plate. The load on these components would be cyclical, given the change in pressure and temperature that occurs as the plant heats up and then cools down.

The critical components for fatigue analysis purposes are the tie rod and hex head bolt, on the basis of:

0

0

0

preload tensile stresses thermal expansion tensile stresses stress concentrations in the threaded sections, and for the levels of stresses involved, a more restrictive number of allowable cycles (versus the stainless steel MNSA components; see Table 1-9.1 of Reference 5.9)

14.1 Normal Operating Pressure Force

3.4.2 Tie Rods

El

3.4. 2.1 Peak Stress

Page 49: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A36 of A42

0

Page 50: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A37 of A42

There are other Normal and Upset transients which are defined for the Piping (per Reference 5.7), but their contribution to fatigue in the tie rod is not significant.

3.4.3 Hex Head Bolt

L

0

Page 51: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A38 of A42

3.4.4 Hex Head Bolt - Clamp

L

0

Page 52: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A39 of A42Page A39 of A42

3.5 Consideration of Hydrostatic Test Pressure Conditions

3.6 Consideration of Faulted Conditions

fK

0

Page 53: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page A40 of A42

4. SUMMARY OF RESULTS

The results presented below were determined using the assumptions defined and justified in Section 2.0. There are no additional contingencies or assumptions that are applicable to these results.

All stresses are satisfactory and meet the appropriate allowable limits set forth in Section III of the ASME Boiler and Pressure Vessel Code (Reference 5.9).

-J

Page 54: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page A41 of A42

5. REFERENCES

5.1 ABB Project Plan No. B-NOME-IPQP-0287 Rev. 0, "Mechanical Nozzle Repair Devices (MNRD) for PZR Bottom Nozzles, PZR Side Nozzles, PZR Upper Nozzles, Hot Leg RTD Nozzles, Hot Leg PDT/Sampling Nozzles, PZR Heater Sleeves', September 1999.

5.2 ABB Combustion Engineering Nuclear Power Quality Procedures Manual QPM-101, Revision 03.

5.3 "Analytical Report for Baltimore Gas & Electric Calvert Cliffs Station Units I and II Piping," Report No. CENC-1179, March 1972.

5.4 Dedication Reports No. 1. 9 481-99-140-1A, Rev. 0, January 2000 2. 9481-99-152-1A, Rev. 0, January 2000

5.5 Rosemount Drawing No. 104-852, Rev. 04, "Thermowell".

5.6 Not Used

5.7 BGE Design Specification No. SP-0846, Rev. 00, "Mechanical Nozzle Repair Device".

5.8 ABB Drawing No. 1. E-MNSABGE-228-001, Revision 04, "Hot Leg RTD Mechanical Nozzle Seal

Assembly" 2. E-MNSA-228-004, Revision 06, "Mechanical Nozzle Seal Assembly Details" 3. E-MNSA-228-020, Revision 05, "Mechanical Nozzle Seal Assy Details" 4. E-MNSA-228-023, Revision 01, "Mechanical Nozzle Seal Assy Details"

5.9 American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, 1989 Edition (No Addenda).

5.10 "Test Report for MNSA Hydrostatic and Thermal Cycle Tests," Test Report No. TRPENG-042, Rev.00.

5.11 "Roark's Formulas for Stress and Strain," Warren C. Young, Sixth Edition, 1989,

McGraw-Hill.

5.12 ABB CE Drawing No. E-233-585, Rev. 6, "Nozzle Details".

5.13 American National Standard, Unified Inch Screw Threads, ANSI B1.1 - 1982.

5.14 "Engineering Mechanics: Statics and Dynamics", F. L. Singer, Third Edition, Harper & Row, New York, 1975.

Page 55: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page A42 of A42

5.15 "How to Calculate and Design for Stress in Preloaded Bolts", A. G. Hopper and G. V. Thompson, Product Engineering, 1964.

5.16 Engineering Report No. B-NOME-ER-0133, Revision 00, "Design Evaluation of MNSA for Various Applications at BG&E Units I and I1", January 2000.

5.17 "Mechanical Engineers' Handbook", M. Kutz, ed., John Wiley & Sons, Inc., 1986.

5.18 "Strength of Materials", F. L. Singer, Second Edition, Harper & Row, New York, 1962

5.19 Union Carbide Grafoil, "Engineering Design Manual, " Volume One, Sheet and Laminated Products, by R. A. Howard, 1987.

5.20 ABB CENP Calculation No. B-PENG-CALC-022, Revision 00, "Analysis of BG&E Hot Leg and Pressurizer MNSAs Seismic Accelerations", November 1999.

Page 56: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

B-PENG-DR-005, Rev. 02 Page B1 of B42

ATTACHMENT B

ANALYSIS OF BG&E UNITS I AND II HOT LEG PDT/SAMPLING NOZZLE MNSA

0

Page 57: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PEW-DR-005, Rev. 02 Page B2 of B42

TABLE OF CONTENTS Section

Page No.

1. INTRODUCTION 4

1.1 Objective 4

1.2 Assessment of Significant Design Changes 4

2. DESIGN INPUTS 5

2.1 Selection of Design Inputs 5 2.1.1 Design and Operating Pressures and Temperatures 5 2.1.2 MNSA Materials 5 2.1.3 Nozzle Materials 5 2.1.4 Material Properties 5 2.1.5 MNSA Component Dimensions 8 2.1.6 Nozzle Dimensions 8

2.2 Assumptions 9 2.2.1 Loading Conditions 9 2.2.2 Consideration of Seismic Loads 9 2.2.3 Friction Force 9 2.2.4 Sealing pressure 10 2.2.5 Preload

10 2.2.6 Dimensions 10

3. ANALYSIS 11 3.1 MNSA Description

11

3.2 Consideration of Impact Load 12 3.2.1 Relative Displacements Due to Thermal Expansion 12 3.2.2 Soft Spring Package Setting vs. Calculated Displacements 13 3.2.3 Determination of Impact Force 14 3.2.4 Impact Force 17

3.3 Stresses in the PDT and Sampling MNSA Components 18 3.3.1 Tie Rod 18 3.3.2 Hex Head Bolt 23 3.3.3 Top Plate 29 3.3.4 Compression Collar 30 3.3.5 Upper Flange 30 3.3.6 Clamp 30

3.4 Fatigue Analysis 35 3.4.1 Normal Operating Pressure Force 35 3.4.2 Tie Rods 35 3.4.3 Hex Head Bolt 37

Page 58: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page B3 of B42

3.4.4 Hex Head Bolt - Clamp 38

3.5 Consideration of Hydrostatic Test Pressure Conditions 39

3.6 Consideration of Faulted Conditions 39

4. SUMMARY OF RESULTS 40

5. REFERENCES 41

LIST OF FIGURES FIGURE DESCRIPTION PAGE

1 MNSA Concept Sketch for PDT/Sampling Hot Leg Nozzle ............................................ 11 2 C om pression C ollar ............................................................................................................ 26

Page 59: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B4 of B42

1. INTRODUCTION

1.1 Objective

The objective of this calculation is to present the results of the evaluation of the Mechanical Nozzle Seal Assembly (MNSA) to be installed on the Hot Leg PDT and Sampling nozzles at the Baltimore Gas &Electric Calvert CLiffs Station Unit I and I1.

The MNSA is a mechanical device that acts as a complete replacement of the 'J" weld between an Inconel 600 instrument nozzle and the Hot Leg pipe. Its function is to prevent leakage and restrain the nozzle from ejecting in the event of a through-wall crack or weld failure of a nozzle. The potential for these events exists due to Primary Water Stress Corrosion Cracking.

1.2 Assessment of Significant Design Changes

This report presents the detailed structural and thermal analyses required to substantiate the adequacy of the design of the BG&E, Calvert Cliffs Units I and II Mechanical Nozzle Seal Assembly as a replacement of the nozzle "J" weld. This analytical work encompasses the requirements set forth in Reference 5.1 and is performed in accordance with the requirements of the ABB CENO Quality Procedures Manual QPM-101 (Reference 5.2).

Addenda to the original Piping Design Report (Reference 5.3) were reviewed and it was determined that their results have no impact on the current analysis and also that the current analysis does not impact their results.

Page 60: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B5 of B42

2. DESIGN INPUTS

2.1 Selection of Design Inputs

2.1.1 Design and Operating Pressures and Temperatures

The Mechanical Nozzle Seal Assembly is considered a pressure-retaining component. The Design Pressure is 2,500 psia and Design Temperature is 650°F. Operating pressure and temperature are 2,250 psia and 6040 F, respectively. Ambient design temperature is 120OF (Reference 5.7).

2.1.2 MNSA Materials

MNSA materials are taken from Reference 5.8.

Item Compression Collar Lower Flange Upper Flange Top Plate Clamp Hex Head Bolt Hex Nut Tie Rod Hex Bolt - Clamp

Material SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-479, Type 304 SA-453, Grade 660 SA-453, Grade 660 SA-453, Grade 660 SA-453, Grade 660

2.1.3 Nozzle Materials

Hot Leg PDT and Sampling Nozzle materials are taken from Reference 5.6.

Item Nozzle Safe End

Material B-166 A-182, Type 316

2.1.4 Material Properties

Material properties used in this analysis include coefficients of thermal expansion (a), Moduli of Elasticity (E), design stress intensity values (Si), and Yield Strength Values (Sy). These properties are presented below and are found in the Appendices of Reference 5.9.

0

Page 61: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B6 of B42

2.1.4.1 Coefficient of Linear Thermal Expansion, a

The following table presents the temperature-dependent coefficients of linear thermal expansion for various materials:

temperature SB-166 SA-182 SA-479 SA-453, (OF) (Alloy 600) 316 SS Type 304 Grade 660

(304 SS) (Alloy 660) 100 6.90 8.54 8.55 8.24 200 7.20 8.76 8.79 8.39 300 7.40 8.97 9.00 8.54 400 7.57 9.21 9.19 8.69 500 7.70 9.42 9.37 8.82 600 7.82 9.60 9.53 8.94 604 7.82* 9.61 * 9.54* 8.94* 650 7.88 9.69 9.61 9.00

* by interpolation

All coefficients are Coefficient B values from Table 1-5.0, where Coefficient B is the mean coefficient of thermal expansion X 1 0a in./in./°F in going from 70OF to the indicated temperature.

2.1.4.2 Modulus of Elasticity, E

The following table presents the temperature-dependent 304 and SA-453, Grade 660:

temperature E (OF)

70 28.3 200 27.6 300 27.0 400 26.5 500 25.8 600 25.3 604 25.3* 650 25.0* 700 24.8

* by interpolation

Moduli of Elasticity for SA-479 Type

All Moduli of Elasticity values are from Table 1-6.0, where E = value given X 106 psi.

0

Page 62: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B7 of 842

2.1.4.3 Design Stress Intensity Value, Sm

The following table presents the temperature-dependent design stress intensity values for various materials:

temperature SA-479, Type 304 SA-453, Grade 660 (OF) Sm Sm

100 20.0 28.3 200 20.0 27.6 300 20.0 27.3 400 18.7 27.2 500 17.5 27.1 600 16.4 27.0 650 16.2 26.9* 700 16.0 26.8

by interpolation

The design stress intensity values for SA-479 Type 304 are from Table I-1.2; and the design stress intensity values for SA-453, Grade 660 are from Table 1-1.3. All Sm values are given in ksi.

2.1.4.4 Yield Strength Value, Sy

The following table presents the temperature-dependent yield strength values for SA-479 Type 304:

The yield strength values for SA-479 Type 304 are from Table 1-2.2. All Sy values are given in ksi.

0

temperature SA-479, Type 304 (OF) SY

100 30.0 200 25.0 300 22.5 400 20.7 500 19.4 600 18.2 650 17.9 700 17.7

Page 63: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 88 of 842

2.1.5 MNSA Component Dimensions

2.1.6 Nozzle Dimensions

7

0

Page 64: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B9 of B42

2.2 Assumptions

2.2.1 Loading Conditions

2.2.2 Consideration of Seismic Loads

Because of the nature of the accelerations from seismic events, only the tie rods will be evaluated for the stress effects of the seismic event. The remaining MNSA components will not be significantly affected. Separate seismic tests on similar MNSA configuration were performed to demonstrate an adequate seal performance (see Reference 5.16).

2.2.3 Friction Force

The effects of any impact of the nozzle against the top plate are dependent upon certain assumptions regarding the determination of the ejection force acting on the nozzle.

In an "ideal* (and worst case) break scenario, the crack would be complete, instantaneous and oriented such that no base or weld metal could interfere with the motion of the nozzle. In this case, the only resistance offered to the nozzle motion would be provided by the attached piping and by the Grafoil seal.

K_I

Page 65: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B10 of B42Page BlO of B42

Sealing pressure

2.2.5 Preload

Nominal values of tie rod/bolt preload are used in this analysis since maximum values of preload will not significantly increase corresponding preload stresses. (A check of the results indicate that use of the maximum preload values will result in stresses which will remain below, or will be on the order of, their respective allowables. Therefore, use of the nominal values is acceptable).

2.2.6 Dimensions

Nominal design dimensions of the parts were used for the calculations of the relative displacement and for the stress analysis, except when noted.

0

L 2.2.4

Page 66: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B11 of B42

3. ANALYSIS

3.1 MNSA Description

The MNSA is a mechanical device that acts as a complete replacement of the "J" weld between an Inconel 600 instrument nozzle and the hot leg pipe. It replaces the sealing function of the weld using a Grafoil seal compressed at the nozzle outside diameter to the outer hot leg surface. The MNSA also replaces the weld structurally by means of threaded fasteners engaged in tapped holes in the outer hot leg surface, and a restraining plate held in place by threaded tie rods. This feature prevents the nozzle from ejecting from the hot leg, should the "J" weld fail or the nozzle develop a circumferential crack.

A sketch of the Hot Leg PDT/Sampling MNSA is presented in Figure 1 below.

FIGURE 1 Hot Leg PDT/Sampling MNSA

Page 67: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page B12 of B42

3.2 Consideration of Impact Load

3.2.1 Relative Displacements Due to Thermal Expansion

K

Page 68: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B13 of B42

3.2.2 Soft Spring Package Setting vs. Calculated Displacements

Page 69: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page B14 of B42

3.2.3 Determination of Impact Force

K

Page 70: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

- 0 B-PENG-DR-005, Rev. 02 Page B15 of B42

I.---

Page 71: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 0 Page B16 of B42

Page 72: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B17 of B42Pae67o 4

3.2.4 Impact Force

Page 73: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02

Page B18 of B42

3.3 Stresses in the PDT and Sampling MNSA Components

The Design Loads for the various MNSA components will be a function of either bolt preload, the impact load, and/or thermal expansion loads, depending upon the effects of the source load upon a particular component.

3.3.1 Tie Rod

Page 74: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B19 of B42

0O

j

Page 75: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page B20 of B42

- Il

Page 76: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page B21 of B42

Page 77: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 622 of B42

0

IJ

Page 78: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page B23 of B42

3.3.2 Hex Head Bolt

Page 79: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B24 of B42

Li

Page 80: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

V B-PENG-DR-005, Rev. 02 Page R25 of 842

Page 81: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02

Page B26 of B42

0O

Page 82: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02

Page 827 of B42

7

Page 83: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

O B-PENG-DR-005, Rev. 02 Page 828 of B42

Page 84: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 629 of B42

3.3.3 Top Plate

r

0

Page 85: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B30 of B42

3.3.6 Clamp

The nozzle clamp is designed to fit tight against the nozzle and to transmit any axial load uniformly into the MNSA top plate. The load transfer between the clamp and the nozzle occurs due to contact/shear at the engaged tooth of the nozzle/clamp design and does not rely on friction.

0

Page 86: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B31 of B42

3.3.6.1 Hex Head Bolt - Clamp

, . , ý - - 'r , .

Page 87: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page B32 of B42

. I I - 4, ý "

Page 88: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 633 of B42

Page B33 of B42

0

Page 89: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B34 of B42

Page 90: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page 835 of B42

3.4 Fatigue Analysis

The fatigue analysis of the components will conservatively consider loads which may exist on the components after weld or nozzle failure has occurred. Prior to failure, components will be subjected to loads due mainly to preload and thermal expansion. After failure, and assuming that the nozzle/clamp is free to move, certain components will be additionally stressed because of the internal pressure forcing the nozzle/clamp up against the top plate. The load on these components would be cyclical, given the change in pressure and temperature that occurs as the plant heats up and then cools down.

The critical components for fatigue analysis purposes are the tie rod and hex head bolts, on the basis of:

0

0

0

0

preload tensile stresses thermal expansion tensile stresses stress concentrations in the threaded sections, and for the levels of stresses involved, a more restrictive number of allowable cycles (versus the stainless steel MNSA components; see Table 1-9.1 of Reference 5.9)

73.4.1 Normal Operating Pressure Force

3.4.2 Tie Rods

3.4. 2. I Peak Stress

0

F

Page 91: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page B36 of B42

Page 92: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B37 of B42

There are other Normal and Upset transients which are defined for the Piping (per Reference

5.7), but their contribution to fatigue in the tie rod is not significant.

3.4.3 Hex Head Bolt

L

Page 93: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B38 of B42

Page B38 of 842

3.4.4 Hex Head Bolt - Clamp

L

0

Page 94: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B39 of B42

3.5 Consideration of Hydrostatic Test Pressure Conditions

K3.6 Consideration of Faulted Conditions

0

I

Page 95: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B40 of B42

4. SUMMARY OF RESULTS

The results presented below were determined using the assumptions defined and justified in Section 2.0. There are no additional contingencies or assumptions that are applicable to these results.

All stresses are satisfactory and meet the appropriate allowable limits set forth in Section III of the ASME Boiler and Pressure Vessel Code (Reference 5.9).

-J

Page 96: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page B41 of 642

5. REFERENCES

5.1 ABB Project Plan No. B-NOME-IPQP-0287 Rev. 0, "Mechanical Nozzle Repair Devices (MNRD) for PZR Bottom Nozzles, PZR Side Nozzles, PZR Upper Nozzles, Hot Leg RTD Nozzles, Hot Leg PDT/Sampling Nozzles, PZR Heater Sleeves", September 1999.

5.2 ABB Combustion Engineering Nuclear Power Quality Procedures Manual QPM-101, Revision 03.

5.3 "Analytical Report for Baltimore Gas & Electric Calvert Cliffs Station Units I and II Piping," Report No. CENC-1179, March 1972.

5.4 Dedication Reports No. 1. 9481-99-140-1A, Rev. 0, January 2000 2. 9481-99-152-lA, Rev. 0, January 2000.

5.5 Union Carbide Grafoil, "Engineering Design Manual, " Volume One, Sheet and Laminated Products, by R. A. Howard, 1987.

5.6 ABB CE Drawing No. E-233-586, Rev. 7, "Nozzle Details".

5.7 BGE Design Specification No. SP-0846, Rev. 00, "Mechanical Nozzle Repair Device".

5.8 ABB CE Drawing No. 1. E-MNSABGE-228-002, Revision 03, 'Hot Leg PDT/Sampling MMSA" 2. E-MNSA-228-013, Revision 10, "Mechanical Nozzle Seal Assembly Details" 3. E-MNSA-228-020, Revision 05, "Mechanical Nozzle Seal Assy Details" 4. E-MNSA-228-004, Revision 06, "Mechanical Nozzle Seal Assembly Details"

5.9 American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, 1989 Edition (No Addenda).

5.10 "Test Report for MNSA Hydrostatic and Thermal Cycle Tests," Test Report No. TRPENG-042, Rev.00.

5.11 "Roark's Formulas for Stress and Strain," Warren C. Young, Sixth Edition, 1989, McGraw-Hill.

5.12 ANSI Standards for Threads, Appendix B, B1.1, 1982.

5.13 "Engineering Mechanics: Statics and Dynamics", F. L. Singer, Third Edition, Harper & Row, New York, 1975.

5.14 "Mechanical Engineers' Handbook", M. Kutz, ed., John Wiley & Sons, Inc., 1986.

Page 97: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page B42 of B42

5.15 "How to Calculate and Design for Stress in Preloaded Bolts", A. G. Hopper and G. V. Thompson, Product Engineering, 1964.

5.16 Engineering Report No. B-NOME-ER-0133, Revision 00, "Design Evaluation of MNSA for Various Applications at BG&E Units I and I1", January 2000.

5.17 'Strength of Materials", F. L. Singer, Second Edition, Harper & Row, New York, 1962

5.18 ABB CENP Report No. MISC-ME-C-230, Revision 02, "Software Verification and Validation Report - ANSYS Version 5.3 on HP9000/800 Series Machines with the HPUX 10.20 Operating System", December 1998.

5.19 ABB CENP Calculation No. B-PENG-CALC-022, Revision 00, "Analysis of BG&E Hot Leg and Pressurizer MNSAs Seismic Accelerations", November 1999.

Page 98: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

B-PENG-DR-005, Rev. 02 Page C1 of C21

Page Cl of C21

ATTACHMENT C

ANSYS EVALUATION OF TOP PLATE

This Attachment contains the figure of the ANSYS model used to obtain the stiffness and the stresses of the MNSA top plate, as well as the resulting output file from the computer run. The output file printed here contains an echo print of the input file used.

0

Page 99: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C2 of C21

FIGURE C1.

Bement Plot of ANSYS Top Plate Model

Page 100: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PB'NlG-DR-005, Rev. 02 Page C3 of C21

ANSYS OUTPUT FILE

BBB BBB EBB BBB BBB BBBB BBB BBBB BBB BBS BBB BBB BBB BBBB BBB BBBB

BBB BBBBB BBB BBBBBB BBB BBBBB BBB BBB

EBB BBBBB EBB BBBBBB BBB BBBBB BBS BBB

AS EA BROWN BOVE R I

C 0 M B U S T I 0 N **4* E N G I N E E R I N G

NUCLEAR POWER WORKSTATION ENVIRONMENT

Date/Time Thu Sep 30 15:45:49 EDT 1999

User Group Project,Task

Job Id Job Name

mendrala v9421me default_charge

Ou9d79en Ou9d79en

Node Name : twister Cpu Type : HP-UX

Process ID : 4138 Priority : 8

Submit Node Directory

tornado twister:/PS/mendrala/bn

Job Streim Commands From the File: twister:/PS/mendrala/bn/sub

1 Executing /ansys53/bin/hp700/ansys.e53

I I WE LC OM E TO THE AN S Y S PROGRAM I I -- -. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -

0

AA

AAAA AAAA

AAAAAA

AAAAAAA A•AAAAA

•AAAAAA

AA AAA AAAAA

AAAAAA

AAAAAAA AAAAAAA

AAAAAA

Page 101: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C4 of C21

0

Page 102: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C5 of C21

Page 103: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

*0 B-PENG-DR-005, Rev. 02 Page C6 of C21

Page 104: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

0 B-PENG-DR-005, Rev. 02 Page C7 of C21

Page 105: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C8 of C21

0

Page 106: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C9 of C21

0

Page 107: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Cl 0 of C21

Page 108: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Cl 1 of C21

0

Page 109: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C12 of C21

0

Page 110: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

SB-PENG-DR-005, Rev. 02 Page Cl 3 of C21

Page 111: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

O B-PENG-DR-005, Rev. 02 Page C14 of C21

Page 112: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C15 of C21

0

Page 113: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Cl 6 of C21

0

Page 114: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page Cl 7 of C21

Page 115: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

O B-PENG-DR-005, Rev. 02 Page C18 of C21

Page 116: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C19 of C210

Page 117: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C20 of C21

0

Page 118: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page C21 of C21

0

Page 119: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

B-PENG-DR-005, Rev. 02 Page D1 of D41

ATTACHMENT D

CALCULATION No. A-CCNPP-9449-1230, Rev. 01 "Evaluation of Attachment Locations for

Mechanical Nozzle Repair Devices on Baltimore Gas and Electric Company

Calvert Cliffs Nuclear Power Plant Units 1 and 2 Hot Leg Piping RTD and PDT/Sampling Instrument

Nozzles"

(41 pages including cover)

-0

Page 120: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

SUMMARY OF CONTENTS Calculation 34 Pages Appendices 0 Pages Attachments 6 Pages

Diskette Attached Yes X No

EVALUATION OF ATTACHMENT LOCATIONS

FOR MECHANICAL NOZZLE REPAIR DEVICES

ON BALTIMORE GAS AND ELECTRIC COMPANY

CALVERT CLIFFS NUCLEAR POWER PLANT UNITS 1 AND 2 HOT LEG PIPING RTD AND PDT/SAMPLING INSTRUMENT NOZZLES

A-CCNPP-9449-1230, REV. 01

Quality Class: QC-1 (Safety-Related)

Contingencies: None PURPOSE: To evaluate the structural integrity of the attachment locations for the mechanical

nozzle repair devices about the RTD and PDT/Sampling Instrument Nozzles in the hot leg piping.

This Design Analysis is complete and verified. Management authorizes the use of its results.

PREPARED BY: B. A. Bell 'j. 2'e4DATE: i/24 /'?C _ _ .

APPROVED BY: D. P. Siska 6:.444a DATE: /2-/_•"-,•c;e

ABB COMBUSTION ENGINEERING CHATTANOOGA, TENNESSEE

CSE-00-127

VERIFICATION STATUS: COMPLETE

The Safety-Related design information contained in this document has been verified to be correct by means of Design Review using the Checklist in QP-3.4 of QPM-101.

Name J. G. Thakkar Signature -7a t 4eDate: ,/ , 5A Ocr" Independent Reviewer

This document is the property of ABB/Combustion Engineering, Chattanooga, Tennessee, and is to be used only for the purposes of the agreement with ABB/CE pursuant to which it is furnished.

Page 121: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 2 of 34

WESTINGHOUSE I

RECORD OF REVISIONS

PARAGRAPH(s) PREPARED INDEPENDENT APPROVED NUMBER DATE INVOLVED BY REVIEWER BY

0 11/12/99 Original Issue B. A. Bell J. D. Key D. P. Siska

12/13/00 Section 1.0, 3.0, B. Bell J. G. Thakkar D.P. Siska 5.0, 6.0, 7.0, & , . / ¢-,,

Add Section 6.8 /2'1)3/2 ], /i$/• r' ,5"7" m,

CSE-00-127

Page 122: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 3 of 34

WESTINGHOUSE I

TABLE OF CONTENTS

Page

1.0 OBJECTIVE OF THE DESIGN ANALYSIS ......................................................... 4

2.0 ASSESSMENT OF SIGNIFICANT DESIGN CHANGES ..................................... 5

3.0 ANALYTICA L TECHNIQUES ................................................................................ 5

4.0 SELECTION OF DESIGN INPUTS ......................................................................... 5

5.0 A SSU M PT IO N S ....................................................................................................... 6

6.0 D ETA ILED A N A LY SIS ......................................................................................... 8

6.1 Seal Assembly Bolted Connection to Piping Evaluation ................................... 10

6.2 Evaluation of RTD and PDT/Sampling Penetration Reinforcement Areas for Standard M N RD ..................................................................................... 12

6.3 Range of Stress Intensity Evaluation of 1/2" Tapped Holes .............................. 17

6.4 Fatigue Evaluation of Tapped Holes ................................................................ 21

6.5 Range of Stress Intensity Evaluation of Grooved Section in PDT/Sampling and RTD Nozzles ............................................................ 24

6.6 Fatigue Evaluation of Grooved Section in PDT/Sampling and RTD Nozzles ...... 28

6.7 Seal Assembly Connection to PDT/Sampling Nozzles ..................................... 30

6.8 Seal Assembly Connection to RTD Nozzles .................................................... 31

7.0 RESULTS / CONCLUSIONS ................................................................................ 32

8.0 R E FE R E N C E S ....................................................................................................... 34

Attachment 1: Design Analysis Verification Checklist & Reviewer's Comment Form (For QA Record only)

CSE-00- 127

Page 123: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 4 of 34

WESTINGHOUSE

1.0 OBJECTIVE OF THE DESIGN ANALYSIS

This report investigates the structural integrity of the attachment locations for the Mechanical Nozzle Repair Devices (MNRD) on Baltimore Gas and Electric Company (BGE) Calvert Cliffs Nuclear Power Plant Units I and 2 Hot Leg Piping RTD and PDT/Sampling nozzles. The MNRDs are described in Reference I along with the Project Plan (Reference 2). A MNRD is attached to the outside surface of a pipe by four 1/2-inch bolts. The eight objectives of this analysis relate to the machined tapped holes made in the pipe to receive the attachment bolts as well as the grooved portion on the PDT/Sampling and RTD nozzles where the MNRD clamp is attached. The objectives are as follows:

The results of this analysis will demonstrate that the use of a MNRD in the hot leg piping will comply with the ASME Code requirements. This analysis can be used for future repair work on any other leaking partial penetration nozzles provided their criteria are the same as those used in this report.

CSE-00- 127

I I

Page 124: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 0 1 Page 5 of 34

WESTINGHOUSE

2.0 ASSESSMENT OF SIGNIFICANT DESIGN CHANGES

The "as-designed" configurations for the hot leg pipes defined in Reference 3 are considered. The design conditions and operating transients (T-NS) as presented in References 4 and 13 are not changed by the results of this analysis.

3.0 ANALYTICAL TECHNIQUES

4.0 SELECTION OF DESIGN INPUTS

The operating conditions for the BGE Calvert Cliffs Nuclear Power Plant Units 1 and 2 hot leg piping along with the design conditions from References 4 and 13 are as follows:

Design Pressure: Design Temperature: Operating Pressure: Operating Temperature:

2500 psia 650 °F (42" & 30" I.D. Pipe)

2250 psia 604 'F (Hot Leg)

The transient conditions for the hot leg piping are also from Reference 4, pages 4, A-79, and B-20. The bending moments are determined from the external loads given in Reference 5, Figure 10, Sheet 4, Section C for the tapped holes evaluation.

CSE-00-127

m

Page 125: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 6 of 34

WESTINGHOUSE

5.0 ASSUMPTIONS

The assumptions included in this design analysis are as follows:

CSE-00-127

Page 126: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 7 of 34

WESTINGHOUSE

5.0 ASSUMPTIONS

L

CSE-00- 127

Page 127: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 8 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

This section contains the structural evaluation of the attachment locations for the mechanical nozzle repair devices (MNRD) on the Calvert Cliffs Units 1 and 2 RTD and PDT/Sampling nozzles in the hot leg piping. The evaluation includes comparing the revised available area of reinforcement to the required area. as well as performing a fatigue evaluation on the hot leg piping outside surfaces with the stress concentration factor due to the attachment stud holes. This section also contains the structural evaluation of the grooved portion of the PDT/Sampling and RTD nozzles including a fatigue evaluation. The following figures from References IA and 1 B show the configuration for the MNRDs and their attachment to the hot leg piping. Stresses due to loads in the stud are concentrated at the upper threads and are negligible at the bottom of the hole.

PDT/Sampling Mechanical Nozzle Repair Device (See References IA and IC for details.)

NOTE: The bottom end of the stud holes in this figure are rounded and do not come to a point as shown.

CSE-00-127

I

Page 128: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 9 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

RTD Mechanical Nozzle Repair Device (See References L B and IC for details.)

CSE-O0-127

Page 129: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01

Page 10 of 34

WESTINGHOUSE'

6.0 DETAILED ANALYSIS

6.1 SEAL ASSEMBLY BOLTED CONNECTION TO PIPING EVALUATION

6.1.1 DETERMINATION MAXIMUM ALLOWABLE LOAD BASED ON THREAD SHEAR Reference 6; Paragraph NB- 3227.2(a) and Reference 7, page 81

CSE-00-127

Page 130: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

Page 11 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.1 SEAL ASSEMBLY BOLTED CONNECTION TO PIPING EVALUATION (Cont'd)

6.1.1 DETERMINATION MAXIMUM ALLOWABLE LOAD BASED ON THREAD SHEAR

6.1.2 EVALUATION OF INSTALLATION TORQUE (PRELOAD)

K

CSE-00-127

A-CCNPP-9449-1230O, Rev. 01

Page 131: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01 Page 12 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.2 EVALUATION OF RTD AND PDT/SAMPLING PENETRATION REINFORCEMENT AREAS FOR STANDARD MNRD

CSE-00-127

Page 132: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 13 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.2 EVALUATION OF RTD AND PDT/SAMPLING PENETRATION REINFORCEMENT AREAS FOR STANDARD MNRD (continued)

CSE-00-127

Page 133: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 14 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.2 EVALUATION OF RTD AND PDT/SAMPLING PENETRATION REINFORCEMENT AREAS FOR STANDARD NINRD (continued)

CSE-00- 127

Page 134: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01 Page 15 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.2 EVALUATION OF RTD AND PDT/SAMPLING PENETRATION REINFORCEMENT AREAS FOR STANDARD MNRD (continued)

CSE-0O0-127

Page 135: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 16 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.2 EVALUATION OF RTD AND PDT/SAMPLLNG PENETRATION REINFORCEMENT AREAS FOR STANDARD MNRD (continued)

K

CSE-00-127

Page 136: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01 Page 17of34

-- WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.3 RANGE OF STRESS INTENSITY EVALUATION OF 1/2" TAPPED HOLES The stresses at the location of the tapped holes for attachment of the MNRD to the hot leg pipe are calculated by classical methods of strength of materials. In order to address the specific location of these holes (i.e. the outside surface of the pipe), the stress calculations are performed according to the provisions of Subsection NB-3200 of ASME Section III. Reference 6. The drilled holes are considered to be local structural discontinuities that effect the peak stresses and fatigue usage ,actor

CSE-00-127

Page 137: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01

Page 18 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.3 RANGE OF STRESS INTENSITY EVALUATION OF 1/2" TAPPED HOLES (cont'd)

CSE-00- 127

Page 138: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01Page 19 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.3 RANGE OF STRESS INTENSITY EVALUATION OF 1/2" TAPPED HOLES (cont'd)

ICSE-00-127

Page 139: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-123_0. Rev. 01 Page 20 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.3 RANGE OF STRESS INTENSITY EVALUATION OF 1/2" TAPPED HOLES (cont'd)

CSE-00-127

Page 140: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 21 of 34

WESTINGHOUSEi

6.0 DETAILED ANALYSIS

6.4 FATIGUE EVALUATION OF TAPPED HOLES (Reference 6: Paragraph NB-3222.4)

CSE-00- 127

Page 141: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 22 of 34

WESTrNGHOUSE

6.0 DETAILED ANALYSIS

6.4 FATIGUE EVALUATION OF TAPPED HOLES (continued)

7I

CSE-00-127

Page 142: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01

Page 23 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.4 FATIGUE EVALUATION OF TAPPED HOLES (continued)

CSE-00-127

Page 143: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01

Page 24 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.5 RANGE OF STRESS INTENSITY EVALUATION OF GROOVED SECTION IN PDT/SAMPLING AND RTD NOZZLES

The stresses at the grooved section of the PDT/Sampling and RTD nozzles for attachment of the MNRD clamp are calculated by classical methods of strength of materials. In order to address the specific location of the grooved section (i.e. the outside surface of the nozzle), the stress calculations are performed according to the provisions of Subsection NB-3200 of ASME Section III, Reference 6. The grooved sections of the nozzles are considered to be local structural discontinuities that effect the

CSE-00-127

Page 144: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 25 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.5 RANGE OF STRESS INTENSITY EVALUATION OF GROOVED SECTION IN PDT/SAMPLING AND RTD NOZZLES (continued)

CSE-00-127

Page 145: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

Page 26 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.5 RANGE OF STRESS INTENSITY EVALUATION OF GROOVED SECTION IN PDT/SAMPLING AND RTD NOZZLES (continued)

CSE-00- 127

A-CCNPP-9449-1230. Rev. 01

Page 146: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 27 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.5 RANGE OF STRESS INTENSITY EVALUATION OF GROOVED SECTION IN PDT/ SAMPLING AND RTD NOZZLES (continued)

CSE-00- 127

Page 147: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 28 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.6 FATIGUE EVALUATION OF GROOVED SECTION IN PDT/SAMPLING AND RTD NOZZLES (Reference 6: Paragraph NB-3222.4)

CSE-00-127

Page 148: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 29 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.6 FATIGUE EVALUATION OF GROOVED SECTION IN PDT/SAMPLING AND RTD NOZZLES (cont'd)

CSE-00-127

Page 149: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 30 of 34

WESTrNGHOUSE

6.0 DETAILED ANALYSIS

6.7 SEAL ASSEMBLY CONNECTION TO PDT/SAMPLING NOZZLES

In the seal assembly connection to the PDT/Sampling nozzles, the maximum permissible shear load in the grooved section of these nozzles is calculated using the minimum shear area per the dimensions from View E in Reference IA and nozzle dimensions in Reference 12B.

K

CSE-00-127

Page 150: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 31 of 34

WESTINGHOUSE

6.0 DETAILED ANALYSIS

6.8 SEAL ASSEMBLY CONNECTION TO RTD NOZZLES

In the seal assembly connection to the RTD nozzles, the maximum permissible shear load in the grooved section of these nozzles is calculated Asing the minimum shear area per the dimensions from View E in Reference I B and nozzle dimensions in Reference 12A.

CSE-00-127

Page 151: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-94 4 9 - 12 30, Rev. 01 Page 32 of 34

WESTINGHOUSE

7.0 RESULTS / CONCLUSIONS

7.1 RESULTS

The objectives and their resolutions are presented below.

CSE-00-127

Page 152: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 33 of 34

WESTINGHOUSE

7.0 RESULTS / CONCLUSIONS

7.1 RESULTS (continued)

7.2. J-NLU-, 7.2 CONCLUSION

CSE-0O0-127

Page 153: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 34 of 34

WESTINGHOUSE

8.0 REFERENCES

1. ABB CENP Drawings A. E-MNSABGE-228-002, Rev. 01, "Hot Leg PDT & Sampling MNSA". B. E-MNSABGE-228-00I, Rev. 04, "Hot Leg RTD Mechanical Nozzle Seal Assembly". C. E-MNSA-228-020, Rev. 01, "Mechanical Nozzle Seal Assembly Details (4 sheets)".

2. ABB CENP Project Plan, B-NOME-IPQP-0287, Rev. 0, "Mechanical Nozzle Repair Devices (MNRD) for PZR Bottom Nozzles. PZR Side Nozzles, PZR Upper Nozzles, Hot Leg RTD Nozzles, Hot Leg PDT/Sampling Nozzles, PZR Heater Sleeves".

3. ABB CENP Drawings A. E-233-580, Rev. 03, "General Arrangement Plan". B. E-233-582, Rev. 09, Piping Details and Assembly".

4. ABBiCE Report No. CENC-1 179, "Analytical Report for Baltimore Gas & Electric Calvert Cliffs Station Units I and 2 Piping", March 1972.

5. Project Specification for Reactor Coolant Pipe and Fittings for Baltimore Gas & Electric Atomic Power Plant, Specification No. 8067-3 1-5, Revision 11.

6. ASME Boiler and Pressure Vessel Code, Section III, Division I - Subsection NB, "Rules for Construction of Nuclear Power Plant Components", 1989 edition, No Addenda.

7. USA Standard ASA-BI. 1-1974, "Unified Screw Threads", 1974.

8. ABB/CE Report No. TR-PENG-012, Rev. 00, "Test Report for Verification Testing of RTD Nozzle Seal Assembly", February I, 1995.

9. ABB/CE Report No. CR-9448-CSE91-1101, Rev. 1, "Acceptance Criteria for Florida Power and Light St. Lucie #1 and #2 Manway and Handhole Stud Hole Threads". Appendix C - "Good Bolting Practices", Volume I issued by EPRI - 3412 Hillview Avenue Palo Alto, California 94304.

10. "Preloading of Bolts", by Bernie J. Cobb; Product Engineering, August 19, 1963.

11. ABB CENP Letter No. NOME-99-VI-0244, "Palo Verde PDT & Sampling Nozzle MNSA Drawing Transmittal", June 7, 1999.

12. ABB CENP Drawings A. E-233-585, Rev. 06, "Nozzle Details Piping". . B. E-233-586, Rev. 07, "Nozzle Details Piping". C. E-233-587. Rev. 06, "Nozzle Details Piping".

13. BGE Design Specification No. SP-0846, Rev. 00, "Mechanical Nozzle Repair Device", April 1999.

CSE-00- 127

Page 154: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 1-1 of 1-6

WESTINGHOUSE NON-PROPRIETARY CLASS 3

ATTACHMENT 1

Design Analysis Verification Checklist (4 pages).

Reviewer's Comment Form (1 page).

(Copies in Q.A. Records)

CSE-00-127

I.

2.

Page 155: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 1-2 of 1-6

WEST[NGHOUSE

._1--- CSE-00-127

Page 156: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01

Page 1-3 of 1-6

WESTINGHOUSE

CSE-00-127

Page 157: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230. Rev. 01 Page 1-4 of 1-6

WESTINGHOUSE i'

CSE-00- 127

Page 158: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01

Page 1-5 of 1-6

WESTINGHOUSE

CSE-00-127

Page 159: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

A-CCNPP-9449-1230, Rev. 01 Page 1-6 of 1-6

WEST[NGHOUSE

CSE-00-127

Page 160: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

WESTINGHOUSE NON-PROPRIETARY CLASS 3

B-PENG-DR-O05, Rev. 02 Page El of E7

ATTACHMENT E

QUALITY ASSURANCE FORMS

CIE Niir.l•pr Prnl^r I I

0

Page 161: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

*0O B-PENG-DR-005, Rev. 02 Page 1E2 of E7Page E2 of E7

L_�2

CE Nuclear Power LLC

Page 162: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PBEJG-DR-OO5, Rev. 02

Page 8 of E7

0

(,.P:, hit le-Innr D^,Adnr I I f-

Page 163: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PENG-DR-005, Rev. 02 Page E4 of E7

fl

(71::: ~ im ll rl"-r 0D^%,, A ,. s r- r"

Page 164: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and

B-PSE4G-DR-OO5, Rev. 02 Page E5 of E7

('E NiicI~r PriwprIIr

0ft

Page 165: Addendum to CENC-1179 Analytical Report for …B-PENG-DR-005, Rev. 02 Page 2 of 12 Contingencies and Assumptions Title: Addendum to CENC- 1179 Analytical Report for Baltimore Gas and