acdc surge protector type-ps 11-m orange series (

2
TOP VIEW SIDE VIEW CONNECTORS 45 220 220 50,1 25 ACDC SURGE PROTECTOR EIGHT (8) STAGES 1/1 SERIES PROTECTOR Schuko plug F-type Sur e Protection G Single Phase CLASS I+II+III 120VAC /230VAC 25 Total Surge Cur.: 105 μ 15 μ Load Rating: & A Response Time: < 1ns kA (8x20 s); kA (10x350 s) Type-PS 11-M Orange Series ACDC Protector Surge multi surge protect -stage or Type - PS 11-M Orange Series is compact stand alone The surge Protector of type ACDC Surge Pro- tector - Orange Series is 8 (eight) stages Single Phase Protector in metal enclosures with applications for load currents of up to 25A . consists of 25 s that s . The protection device have high grade cascade bi-directional of phase (L) and neutral (N) wire and special diagnostic for condition of ground. ACDC protectors have high-grade cascade bidirectional filtering. They are tracking AC waveform eliminating so-called pollution in power AC supply. These protectors have special design to protect and improve functioning of sophisticate equipment in Telecommunications, Computers, Medical equipment, Military, Home electrical appliances and other. Installation of Surge type - PS is excellent choice for investment in the quality of your power network supply, extended equipment life and reduce their down time and errors. 8 (eight) & A protection stage provide effective and reliable protection against surges and transients EMI/RFI filtering The scope of applications of ACDC Surge Protectors is quite wide and refers to the protection of electrical devices against impulse surge and high-frequency (electromagnetic) disturbance, oscillation, speaks in network power supply and atmospheric discharge. ACDC Protector If the stages 2,4 and 6 are out of function, the stages 1,3 and 7 are still provide a high grade cascade bi-directional filtering along with ultimate (5-th) protection stage. Application: Investment: Technical Specifications: Reliability: www.acdc-dcac.eu Empowered by Innovation CLASS CLASS I+II+III I+II+III 20 20 home home telecom telecom industry industry center center IT IT IP IP 3 3 0 0 1 1 2 2 LPZ LPZ Metal Enclosures ACDC ors have five ( ) and - on TVS . That with re Multi-Stage Surge Protect built-in 5 patents use four (4) complementary different prote cti technologies, (Varistor, Gas Tube, Nanocrystalline Cores and technology) in one unit result ducing the surge current up to 99.9% at single point. Innovation Approuch to Surge Protection his characteristic not - and can offer competitive surge pro ducts present a fundamental improvement in T Surge Protection technology. ACDC Surge Protectors a applicable f professions such as planners, construction engineers, designers, electricians and others. Implementation of re simple and or PLUG IN INSTALLATION - SCHUKO PLUG Sur Sur e G MULTI-STAGE SURGE PROTECTION

Upload: acdc-multi-stage-surge-protection

Post on 06-Mar-2016

214 views

Category:

Documents


1 download

DESCRIPTION

ACDC DCAC Company as manufacturer of Multi-Stage Surge Protectors has opened online web store that is available for worldwide buyers (http://shop.acdc-dcac.eu). Necessity about this step was requested from many of our customers which have required our sophisticated multi-stage surge protection for their electrical devices. Our online store provides quick and easy order and fast post-delivery to your door.

TRANSCRIPT

Page 1: ACDC Surge Protector Type-PS 11-M Orange Series (

TOP VIEW

SIDE VIEW

CONNECTORS

45

220

220

50,125

ACDC SURGE PROTECTOREIGHT (8) STAGES 1/1 SERIES PROTECTOR

Schuko plugF-type

Sur e ProtectionG

Single Phase CLASS I+II+III

120VAC /230VAC 25

Total Surge Cur.: 105 µ 15 µ

Load Rating: & A

Response Time: < 1ns

kA (8x20 s); kA (10x350 s)

Type-PS 11-M Orange Series

ACDC Protector Surge

multi surge protect-stage or

Type - PS 11-M Orange Series is compact stand

alone

The surge Protector of type ACDC Surge Pro-

tector - Orange Series is 8 (eight) stages Single Phase Protector in metal

enclosures with applications for load currents of up to 25A .

consists of 25

s that s

. The protection device have high grade cascade bi-directional

of phase (L) and neutral (N) wire and special diagnostic for

condition of ground.

ACDC protectors have

high-grade cascade bidirectional filtering. They are tracking AC waveform

eliminating so-called pollution in power AC supply.

These protectors have special design to protect and improve functioning of

sophisticate equipment in Telecommunications, Computers, Medical

equipment, Military, Home electrical appliances and other.

Installation of Surge type - PS is excellent

choice for investment in the quality of your power network supply, extended

equipment life and reduce their down time and errors.

8 (eight) & A protection

stage provide effective and reliable protection against surges and

transients

EMI/RFI filtering

The scope of applications of ACDC Surge Protectors is quite

wide and refers to the protection of electrical devices against impulse surge

and high-frequency (electromagnetic) disturbance, oscillation, speaks in

network power supply and atmospheric discharge.

ACDC Protector

If the stages 2,4 and 6 are out of function, the stages 1,3 and 7

are still provide a high grade cascade bi-directional filtering along with

ultimate (5-th) protection stage.

Application:

Investment:

Technical Specifications:

Reliability:

www.acdc-dcac.euEmpowered by Innovation

CLASS CLASS

I+II+III I+II+III 20 20homehome telecomtelecom industryindustry centercenterIT IT

IP IP

3 3 0 0 1 1 2 2 LPZ LPZ

Metal Enclosures

ACDC ors have five ( )

and -

on

TVS . That with

re

Multi-Stage Surge Protect built-in 5

patents use four (4) complementary different prote

cti technologies, (Varistor, Gas Tube, Nanocrystalline

Cores and technology) in one unit result

ducing the surge current up to 99.9% at single point.

Innovation Approuch to Surge Protection

his characteristic not -

and

can offer competitive surge pro

ducts present a fundamental improvement in TSurge Protection technology. ACDC

Surge Protectors a applicable f professions

such as planners, construction engineers, designers,

electricians and others.

Implementation of

re simple and or

PLUG IN INSTALLATION- SCHUKO PLUG

SurSur eGMULTI-STAGE SURGE PROTECTION

Page 2: ACDC Surge Protector Type-PS 11-M Orange Series (

Technical SpecificationType - PS 11-M Orange Series

Basic Circuit Diagram - Orange Series:

Bi-direct.Filter

LIN

NIN

GND

C C

C

ThermalCut-Off

Var.

GTD

Control

GTD

Bi-directionalFilter

(No back EMF effect)

C

ThermalCut-Off

Var.

Red

Control

GTD

Yellow Green

TVSLimiter

NOUT

LOUT

GND

TechnologyMulti-Stage Surge ProtectionEight (8) Stages Series ProtectorSpecification

Load

Basic Options

Installation

Product Standard

Cascade bi-directional EMI-RFI filtering of phase (L) and neutral (N) wire

Up to 25A single phase; up to 3kW load for120VAC; up to 5kW load for 230VAC

Indication for bed grounding

Plug-in installation, schuko plug, therminal block or according customer requirements

IEC61643-1 Class I+II+III; IEC60939-2

Protection StageTechnical Specification

Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)

1. First stage L=0.7mH; Imax=up to 25A

L=4.2mH; Imax=up to 25A

Surge Cur. kA (8/20 s)25 μ

U stage He r upstream, 300DC for 120VAC or 2 C for 230VAC appears on the . C < 200A gl/gG.

ltimate protection . switch-off the circuits breake install if the pick voltage > 5 0VD

output ircuits breaker

TVS μLimiter 500A (8/20 s)< 1ns (nanosecond)

; Typical response ec

Surge Cur. 80kA (8/20μs) or 12,5kA (10/350μs)

L=0.7mH; Imax=up to 25A

3. Third stage

5. Fifth stage

7. Seventh stage

2. Second stage

4. Fourth stage

6. Sixth stage

8. Eight stage

Function Technology

Nano Cr stalline Core (L-C configuration)

y

Varistor with thermal cut-off

Long term signal suppressionfrom 1 s to sec2 .μ Control Gas Tube Discharge

High speed efficiencysignal suppression

Transient Voltage Suppressor

Suppression signal shape (L-N) 8/20 s or 10/350 s, μ μ

Varistor with thermal cut-offControl Gas Tube Discharge

;

Nano Cr stalline Core (L-C configuration)

y

Suppression signal shape (L-N) 8/20 s, μ

Nano Cr stalline Core (L-C configuration)

y

Suppression signal shape ( ) 8/20 s or 10/350 sN-Gnd , μ μ Control Gas Tube Discharge

ACDC Surge Protector Type-PS 11-M Orange Series

Bi-directional filtering );;

(L-NFront signal edge reduction

Bi-directional EMI/RFI filter;;Front signal edge reduction

Bi-directional filtering N L);;

( -Front signal edge reduction

Type

Order Code

Total Surge Cur.

Dimension (WxDxHmm)

Weight (kg)

Type - PS 11-M

500.215

105kA (8/20 ) or 15kA (10/350 )μs μs

220x50x45

1,6

Single Phase ACDC Surge Protectors Type - PS 11-M Orange Series

[email protected] ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia Phone: 389 2 3216 988; Fax: 389 2 3216 993

Applications: Features:

Certificate of Quality

Varistors Standard

E

Pro Standard acc.

lect. Magn. Interfer.

tec.

ISO 9001:200

UL 1449

IEC 60

IEC 61643-1 lass I

8

IEC 61643-1;

939-2

C +II +III

Integrate Multi - Protection SystemEight Protection StagesBi-directional Wave Filtering

Thermal Circuit ProtectionHigh Reliability

Response Time < 1ns

Stage

Expel Ground Contamination

Excellent

ComputersServersTelecommunicationMedical equipmentSensitive electronic

Industrial grade

Solars

SurSur eG MULTI-STAGE SURGE PROTECTION