Absorption of CO2 from a
simulated flue gas using a
rotating packed bed.
Dr Jonathan Lee, Dr Pierrot Attidekou, Tolu Kolawole, James Hendry
School of Chemical Engineering and Advanced Materials
Newcastle University
![Page 2: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/2.jpg)
25th Pin Meeting, 21st June 2017
Talk Outline
▪ Carbon Capture from CCGT power plant
▪ Process intensification technologies
▪ Proposed solution
▪ Absorber mass transfer studies
▪ Rotating packed bed size estimates
▪ Future work
![Page 3: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/3.jpg)
25th Pin Meeting, 21st June 2017
250 MWe CCGT Power Plant
Purge gas
345 kg/s
CO2
Flue gas
365 kg/s
40˚C
Lean amine
720 kg/s
Rich amine
740 kg/s
104 ˚C
118 ˚C
54 ˚C45 ˚C
43 ˚CA
bsorb
er
Regenera
tor
Steam
52 kg/s
154 MW
30 MW
121 MW
53 MW
8400 m2
11300 m2
240 m2
1300 m2
![Page 4: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/4.jpg)
25th Pin Meeting, 21st June 2017
The Problem (250 MWe Gas Turbine)
Twin absorbers
9.5 m diameter
30 m tall
regeneration
column
8.2 m diameter
30 m tall
Heat exchanger volumes based on an area per unit volume of 225 m2 m-3
amine inter cooler
50.2 m3
reboiler for regenerator, 37 m3condenser for
regenerator
1.1 m3
amine cooler
5.8 m3
![Page 5: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/5.jpg)
25th Pin Meeting, 21st June 2017
Rotating Packed Bed
• High though put in a small volume.
• Diameters 0.2 – 4.0 m.
• 20 – 750 times gravitational
acceleration.
• Rate of mass transfer 10-1 kmols m3 s-1
(HTU≈cm)
• Residence times of 1-10 s.
• Pressure gradient ≈ 500 Pa m-1
Rotating Packed Bed (RPB)
![Page 6: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/6.jpg)
25th Pin Meeting, 21st June 2017
Rotating Packed Bed
Increase MEA concentration from 30-70wt%- Reduction in the liquid flows.
- Column diameters and heat exchanger sizes are reduced.
- Viscosity of the amine solution is increased.
packed column RPB
Chen 2006
30wt% MEA µ1 = 3 mPa s 70wt% MEA µ2 = 16 mPa s
packed column RPB
kLa( )
m2
kLa( )
m1
= 0.88m
1
m2
æ
èç
ö
ø÷
0.83 kLa( )
m2
kLa( )
m1
= 0.91m
1
m2
æ
èç
ö
ø÷
0.27
kLa( )
80wt%
kLa( )
30wt%
= 0.22kLa( )
80wt%
kLa( )
30wt%
= 0.58
Chen Y, Fang-Yi L, Clifford Y T, Hwai-Shen L, 2006, “Packing Characteristics for Mass
Transfer in a Rotating Packed Bed”, Ind Eng Chem Res, 45, 6846-6853
70 wt% 70 wt%
![Page 7: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/7.jpg)
25th Pin Meeting, 21st June 2017
Spinning Disc Heat Transfer
• Extremely thin films (typically 50-
500 μm thick)
• Excellent mixing characteristics
due to high shear and surface
waves.
• Rates of heat and mass transfer
are very high.
• Convective heat transfer coefficient
> 10 kW m-2 ˚C-1
• Higher values for heat transfer
during boiling/condensation.
Spinning Disc
![Page 8: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/8.jpg)
25th Pin Meeting, 21st June 2017
Process Intensification
• Heat exchange area/unit volume of
up to 1300 m2 m-3.
- Shell and tube: 100 m2 m-3.
- Plate and frame: 400 m2 m-3.
• Convective heat transfer coefficient
for liquid duty 7-10 kW m-2 ˚C-1
Compact Heat Exchangers
Pictures from www.heatric.com
![Page 9: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/9.jpg)
25th Pin Meeting, 21st June 2017
Proposed Solution
▪ Consortium of Imperial College, Newcastle University and Sheffield
University are studying the intensification of post combustion carbon
capture (EPSRC EP/M001458/1)
▪ Use rotating packed beds to reduce the size of mass transfer elements.
▪ Use spinning discs for boiling heat transfer for the regeneration column reboiler.
▪ Use compact heat exchangers for the rich amine preheater and lean amine cooler.
![Page 10: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/10.jpg)
25th Pin Meeting, 21st June 2017
Proposed Solution
amine inter cooler
lean amine cooler
condenser
RPB absorber
RPB solvent
regenerator
reboiler
• Absorber volume is reduced by
a factor of 12.
• Regenerator volume is reduced
by a factor of 16.
![Page 11: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/11.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer Studies
![Page 12: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/12.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer StudiesO
D =
300 m
m
Axial length = 20 mm
ID =
80 m
m
‘eye’ or centre of the RPB
where flooding occurs
Packing is stacked sheets of stainless steel mesh (aP = 694 m2/m3, e = 0.84)
![Page 13: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/13.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer Studies
• RPB
- 300 mm outer diameter
- 80 mm inner diameter
- Axial length 20 mm
- 600 – 1450 rpm
• Measurements
- Inlet and outlet CO2
concentration in the air.
- Inlet and outlet loading of the
solvent.
- Pressure drop between the inlet
and outlet gas.
- Power consumption.
- Liquid and gas temperatures.
![Page 14: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/14.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer Studies
Experimental data presented in terms of CO2 penetration defined as
follows:
(%) CO2 removal efficiency= 𝑦𝐶𝑂2,𝑖𝑛−𝑦𝐶𝑂2,𝑜𝑢𝑡
𝑦𝐶𝑂2,𝑖𝑛𝑋 100 (1)
Calculation of 𝐾𝐺𝑎
The number of transfer units (NTU) was calculated assuming the CO2
concentration in the liquid phase was zero:
𝑁𝑇𝑈𝑂𝐺 = 𝑦1𝑦2 𝑑𝑦
𝑦−𝑦∗= ln
𝑦𝐶𝑂2,𝑖𝑛
𝑦𝐶𝑂2,𝑜𝑢𝑡(2)
Overall gas-phase mass transfer coefficient:
𝐾𝐺𝑎𝑒 =𝑄𝐺
𝜋 𝑟𝑜2−𝑟𝑖
2 𝑍𝑁𝑇𝑈𝑂𝐺 (3)
![Page 15: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/15.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer Studies
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
200 400 600 800 1000 1200
%C
O2
re
mo
va
l
rotational speed (rpm)
30% MEA L/G = 2.7
30% MEA L/G = 3.1
30% MEA L/G = 3.5
50% MEA L/G = 1.8
50% MEA L/G = 2.1
50% MEA L/G = 2.4
70% MEA L/G =1.3
70% MEA L/G = 1.5
70% MEA L/G = 1.7
![Page 16: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/16.jpg)
25th Pin Meeting, 21st June 2017
Absorber Mass Transfer Studies
1.0
2.0
3.0
4.0
5.0
6.0
7.0
200 400 600 800 1000 1200
KGa (
s-1
)
rotational speed (min-1)
30% MEA L/G = 2.7
30% MEA L/G = 3.1
30% MEA L/G = 3.5
50% MEA L/G = 1.8
50% MEA L/G = 2.1
50% MEA L/G = 2.4
70% MEA L/G =1.3
70% MEA L/G = 1.5
70% MEA L/G = 1.7
90% MEA L/G = 0.9
90% MEA L/G = 1.0
90% MEA L/G = 1.2
![Page 17: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/17.jpg)
25th Pin Meeting, 21st June 2017
Rotating Packed Bed Size Estimates
• Use the experimental data and correlations from literature to estimate the size of
RPB required to capture 90% of the CO2 from gas turbine exhaust gases for a 250
MWe unit:
• Assumptions:
- Use mono ethanolamine with an amine:CO2 molar ratio of 4:1
- Solvent feed contains 0.1 moles CO2 per mole amine
- Rotational speed = 100 rpm
- Liquid feed jet velocity = 4 m s-1
- Power calculation based on the K.E. of the liquid leaving the tip of the RPB
- Packing: aP = 694 m2 m-3, e = 0.84
- KGa values are constant
![Page 18: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/18.jpg)
25th Pin Meeting, 21st June 2017
Rotating Packed Bed Size Estimates
Amine
strength
(L/G)mass Di(1) (m) Z(2) (m) KGa (s-1) Do (m) Power
(MW)
30
mass%
2.7 3.1 4.8 2.1 10.2 1.4
50
mass%
1.6 3.1 4.2 3.9 8.3 0.6
70
mass%
1.2 3.1 3.9 4.7 7.9 0.4
90
mass%
0.9 3.1 3.7 5.2 7.7 0.3
1. The inner diameter is based on a gas velocity limit to ensure no entrainment of the liquid jets feeding the packed
bed: Agarwal L, Pavani V, Rao D P, Kaistha N, 2010, "Process Intensification in HiGee Absorption and
Distillation: Design Procedure and Applications", Industrial and Engineering Chemistry Research, 49, 10046-
10058.
2. The axial length is estimated using a Jassim’s flooding correlation: Jassim M S, Rochelle G, Eimer D, Ramshaw
C, 2007, "Carbon Dioxide Absorption and Desorption in Aqueous Monoethanolamine Solutions in a Rotating
Packed Bed", Industrial and Engineering Chemistry Research, 46, 2823-2833.
![Page 19: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/19.jpg)
25th Pin Meeting, 21st June 2017
Rotating Packed Bed Size Estimates
• Assumptions:
- Solvent loading reduced from 0.33 to 0.10 moles CO2 per mole amine
- Use 1.8 kg steam at 4.5 barg per kg CO2 in the feed
- Rotational speed = 100 rpm
- Liquid feed jet velocity = 4 m s-1
- Power estimate based on the K.E. of the liquid leaving the tip of the RPB
- Packing: aP = 694 m2 m-3, e = 0.84
- KLa values are constant
30 mass% amine mfeed = 1021 kg s-1 P = 101300 Pa T = 393 K
Composition: 6.6 mass% CO2 28 mass% MEA 65 mass% H2O
Estimates based on liquid side mass transfer data from: Cheng HH, Lai CC, Tan CS, 2013, “Thermal regeneration of
alkanolamine solutions in a rotating packed bed”, International Journal of Greenhouse Gas Control, 16, 206-216
Amine
strength
(L/G)mass Di(1) (m) Z(2) (m) KLa (s-1) Do (m) Power
(MW)
30
mass%
7.9 2.2 5.4 0.011 5.3 0.4
![Page 20: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/20.jpg)
25th Pin Meeting, 21st June 2017
Future Work
CO2 +
steam
lean
amine
rich
amine
LP
steam
condensat
e
spinning
disc
reboiler
rotating
packed
bed
stationary
rotor case
• Co-current and cross flow absorption measurements.
• Combined reboiler and regenerator
![Page 21: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/21.jpg)
25th Pin Meeting, 21st June 2017
Acknowledgements
▪ Prof. Meihong Wang from University of Sheffield for data on
250 MWe plant.
▪ Organizations who support our RPB work
![Page 22: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/22.jpg)
25th Pin Meeting, 21st June 2017
▪ Thank you for your attention.
▪ Any questions?
![Page 23: Absorption of CO2 from a simulated flue gas using a rotating … OF CO2 FROM A SIMU… · column 8.2 m diameter 30 m tall Heat exchanger volumes based on an area per unit volume of](https://reader034.vdocuments.us/reader034/viewer/2022051406/5aa6804d7f8b9afa758e8835/html5/thumbnails/23.jpg)
25th Pin Meeting, 21st June 2017
RPB Flow Patterns