about the material

24
PG 1 Flashing profiles PG 2 Chimney restoration PG 3 Gutters & downspouts PG 4 Roofing materials PG 5 Window sills Made in GERMANY Haus- und Dachtechnik GmbH The whole range for roof & wall Producer with expertise www.sarei.com

Upload: others

Post on 24-Nov-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

PG 1Flashing profiles

PG 2Chimney restoration

PG 3Gutters & downspouts

PG 4Roofing materials

PG 5Window sills

Made inG E R M A N Y

Haus- und Dachtechnik GmbH

The whole range for roof & wall

Producer with expertise www.sarei.com

Combination with other metalsCompatibility

naturalaluminium

zinc

copper

naturalaluminium zinc copper

OK

OK

OK

OK

no

no

OK

Do not combine with other metals!

no

no

About the material

Note:

- Grinding marks / score marks do not affect the functionality!- Risk of injury: Beware of sharp edges!- Metals are electrically conducting!

Deviations and differences between images and products do not affect the functionalityand do not constitute a reason for complaint!

Catalogue images and brochure images:

Aluminium - valuable characteristics:

Processing instructions:Connection Fastening

overlap 30-50 mmglue (silicone, acrylic resin, metal glue)aluminium rivet

high-grade steel screws withrosettes and rubber washersgalvanized clout nails

high durability low weightmechanical firmness and limbernessresistant to corrosion and agingincombustibleeasy processing

2

Ridge flashing European Article Number

a bc

Type 250 mma = 125 mmb = 125 mmc = 80°

1 m: 42 600 36 89 0068

2 m: 42 600 36 89 0181

Roofing Connection

bitumen shingles

torch-on felt

roof tiles

roof slate

a

b

c1 m: 42 600 36 89 00752 m: 42 600 36 89 0198

1 m: 42 600 36 89 35192 m: 42 600 36 89 3526

Eaves tray no. 1Type 200 mm

Type 250 mm

a = 60 mmb = 125 mmc = 115°

a = 85 mmb = 150 mmc = 115°

European Article Number

Connection

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing

Product group 1 Flashing profiles

3

Product group 1 Flashing profiles

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

Eaves tray no. 2 European Article Number

Type 250 mma = 235 mm

1 m: 42 600 36 89 0082

2 m: 42 600 36 89 0204a

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

Drip edge no. 1 European Article Number

Type 250 mma = 104 mmb = 35 mmc = 95 mm

1 m: 42 600 36 89 0037

2 m: 42 600 36 89 0150a

b

c

4

Product group 1 Flashing profiles

Drip edge no. 2 European Article Number

Type 185 mma = 120 mmb = 50 mmc = 45°

1 m: 42 600 36 89 2710

2 m: 42 600 36 89 2727

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

wood chamfer strip

a

bc

wood chamfer strip

Drip edge - corner jointDrip edge no. 1 Drip edge no. 2

5

Product group 1 Flashing profiles

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

Drip edge no. 3 European Article Number

Type 250 mma = 104 mmb = 35 mmc = 80 mm

1 m: 42 600 36 89 0020

2 m: 42 600 36 89 0143a

b

c

Roofing Connection

Drip edge no. 4 European Article Number

Type 250 mma = 205 mmb = 30 mm

1 m: 42 600 36 89 2178

2 m: 42 600 36 89 2185

bitumen shingles

torch-on felt

roof tiles

roof slate

a

b

6

Product group 1 Flashing profiles

Valley flashing European Article Number

Type 333 mma = 149 mmb = 149 mmc = 130°

1 m: 42 600 36 89 0105

2 m: 42 600 36 89 0228

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

a bc

Wall flashingno. 1 European Article Number

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

&Wall flashing no. 1Type 250 mm

Type 66 mm

a = 125 mmb = 125 mmc = 95°

Counter flashing

a = 57 mm

1 m: 42 600 36 89 00512 m: 42 600 36 89 0174

1 m: 42 600 36 89 00132 m: 42 600 36 89 0136

a

b

ca

Counterflashing

7

Product group 1 Flashing profiles

European Article NumberWall flashing no. 2Type 250 mm

Type 66 mm

a = 155 mmb = 80 mmc = 95°

Counter flashing

a = 57 mm

1 m: 42 600 36 89 00442 m: 42 600 36 89 0167

1 m: 42 600 36 89 00132 m: 42 600 36 89 0136

a

b

ca

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

Wall flashingno. 2 & Counter

flashing

Extruded counter flashing European Article Number

Type 70 mma = 60 mm

1 m: 42 600 36 89 8156

2 m: 42 600 36 89 8163

bitumen shingles

torch-on felt

roof tiles

roof slate

Roofing Connection

* Tip: Seal the joint between counter flashing and brickwork with acrylic resin!

a

8

Product group 1 Wall coping

Wall coping systemsWall coping with mounting

Fastening: with clamp mounting (extruded aluminium flashing with plastic sealing)

SAREI wall copings protect brickworks from influences of the weatherlike snow, ice and frost.

Colours and dimensions are customizable according to custommer’s request.

Mounting: - mount on previously installed clamp mountings - fix clamp mountings at intervals of 750 mm to each

other at the joints of the copings

The special character of the clamp mountings even protects the joints from water ingress.

natural aluminiumnatural aluminiumnatural aluminiumsilvery aluminiumsepia aluminiumwhite aluminiumspecial colourRAL: .................material thickness:

Material:1,5 mm2,0 mm3,0 mm1,5 mm1,5 mm1,5 mm

......mm

.......... mm

.......... mm

.......... mm

plastic sealing

cross section of clamp mounting

wall copingclampmounting

Wall coping without mounting

Fastening:

Connection:

screw / glue onto walls or planks

connect with lower connector

The special character of the connector even protects the joints from water ingress.

Colours and dimensions are customizable according to custommer’s request.

natural aluminiumnatural aluminiumanthracite aluminiumsepia aluminiumwhite aluminium

Material:0,65 mm1,00 mm0,80 mm0,80 mm0,80 mm

.......... mm

.......... mm

.......... mm

brick-red aluminiumzinccopperspecial colourRAL: .................material thickness:

0,80 mm0,70 mm0,60 mm

......mm

SAREI wall copings protect brickworks from influences of the weatherlike snow, ice and frost.

9

Product group 1 Custom flashing profiles

Enquiry formCopy and send by fax

brick-red aluminium 0,8 mm

zinc 0,7 mm

copper 0,6 mm

high-grade steel 0,8 mm

Material (up to 3 m lenght):

natural aluminium 1,5 mm

sepia aluminium 1,5 mm

silvery aluminium1,5 mm

white aluminium 1,5 mm

Material (up to 2 m length):

natural aluminium 0,65 mm

anthracite aluminium 0,8 mm

sepia aluminium 0,8 mm

white aluminium 0,8 mm(polyester paint)

(polyester paint)

(polyester paint)

Send us your sketchincluding specifications!

Attention:

As coloured flashings are coated on one side only,please mark the side that you wish to be coated!

Custom flashings are excluded from redemption!

Store address Customer address

10

Product group 2 Chimney restoration

Attention

Make sure that the supporting surface of the chimney chase is even, horizontal and solid.

Use high-grade steel screws with rosettes and rubber washers to mount the cover.

The chase cover has no pilot holes, so you can mount it individually.

The ultimate consumer bears responsibility for professional and properly mounting of the chimneychase cover. Neither the producer, nor the trader can be held responsible for improper mounting!

Chase coverPerfect protection for your chimney!

- high-grade steel

Available materials:

- copper

Please contact us, if you are interested in other materials.

- 50 mm lateral chamfer (circumferentially)

- circular or quadrangular cutout

Production:

Quantityhigh-grade

steel copper lenght in mm width in mm

External dimensions of chimney chased1 d2 O

- Please specify the external dimensions of the chimney chase when sending us your enquiry/order!

- The chase cover is manufactured 25 mm circumferentially larger.

lengthwidth

d1

d2O

Chimney chase

11

Product group 2 Chimney restoration

Attention

Make sure that the supporting surface of the chimney chase is even, horizontal and solid.

Before mounting: Check wind load and load-bearing capacity of the chimney chase.(If you are uncertain, contact a chimney sweeper.)

Use the included dowels only for solid masonry and concrete slabs.

The chimney cap has no pilot holes, so you can mount it individually.

The ultimate consumer bears responsibility for professional and properly mounting of the chimney cap.Neither the producer, nor the trader can be held responsible for improper mounting!

Chimney capPerfect protection for your chimney!

Available materials:

- high-grade steel

- copper

- rigid or hinged version

, und

Standard caps for chimney chase (external dimensions):

400 x 400 mm 500 x 500 mm 600 x 600 mm

Please contact us, if you are interesed in special sizes.

Quantityhigh-grade

steel copper rigid hinged

External dimensionsof chimney chase

length in mm width in mm

Fastening

lenghtwidth

Chimney chase

- Please specify the external dimensions of the chimney chase when sending us your enquiry/order!

- The chimney cap is manufactured 50 mm circumferentially larger.

12

Product group 2 Chimney restoration

Attention

Make sure that the supporting surface of the chimney chase is even, horizontal and solid.

Before mounting: Check wind load and load-bearing capacity of the chimney chase.(If you are uncertain, contact a chimney sweeper.)

The ultimate consumer bears responsibility for professional and properly mounting of the chimneyhousing. Neither the producer, nor the trader can be held responsible for improper mounting!

Chimney housingcoloured aluminium, pre-weathered zinc & copper- pre-fabricated construction kit according to your specifications

- for subsequently mounting

- give unsightly or weathered chimneys a new look

- durable protection from outside influences

- easy mounting due to exact pre-fabrication

- no soldering/brazing or bending

aa2bb2cd1

======

mmmmmmmmmmmm

d2e1e2e3f1f2

======

mmmmmmmmmmmm

zinc (pre-weathered)copperanthracite aluminiumsepia aluminiumbrick-red aluminium

anthracitebrick-red

wall & chimneyflashing tape

- 300 mm, structured -

Mafle in mm

Alu-Flex 5,0 m(red marking in picture above)

browngrey / silvery

Chimney housing

13

Product group 3 Gutters & downspouts

Gutters & downspouts

1 2

3

4 5

6

7 8 910

11 12

13

14

15

16

17

18

19

20

naturalaluminium

whitealuminiumsimilar toRAL-9002

brownaluminium

greenaluminiumsimilar toRAL-6005

anthracitealuminiumsimilar toRAL-7016

Quantity determination

Product Quantity

Size:

Material: anthracite aluminiumzinccopper

half-round gutter box gutternatural aluminiumzinccopper

Type:

Size: 80 mm

Material: natural aluminiumzinccopper

half-round gutter box gutternatural aluminiumzinccopper

Type:

Stop end for flanging/soldering1Gutter 2,0 m (only gutters of 3,0 m length are coloured)2Gutter leaf guard (PVC) universal, grey / brown 1,0 m 3Top fix rafter bracket (interval 50 - 70 cm)4Wire downspout strainer5Plug-in outlet6Bird control spikes (gutter cilips) (not compatible with copper)7Inside gutter miter8Fascia bracket (interval 50 - 70 cm)9Gutter connector + self sealing gutter connector10Outside gutter miter11Stop end for adhesive bonding12Downspout bracket with screw13Elbow 72°14Elbow 40°15Downspout 2,0 m16Downspout cleanout type 117Downspout cleanout type 218Extension for downspout cleanout type 219Downspout connector20Screws (25 pieces)Glue

natural aluminiumwhite aluminiumbrown aluminiumdark greenaluminium

125 mm 150 mm100 mm

14

Product group 3 Gutters & downspouts

Gutters & downspouts

for flanging / soldering

Stop end (half-round)

1

Half-round gutter

2 3

Gutter leaf guard

Mount the brackets inintervals of 50-70 cm.

4

Top fix rafter bracket (half-round)

Wire downspout strainer

5

Plug-in outlet (half-round)

6

Bird control spikes type 4(gutter clips)

7

Gutter miter (half-round)

118 +

Mount the brackets inintervals of 50-70 cm.

9

Gutter connector (half-round)

10

Fascia bracket (half-round) Self-sealing gutter connector

10

Stop end (half-round)

12

for adhesive bonding

Downspout bracket with screw

13 14

Elbow 72° Elbow 40°

15 16

Downspout 2,0 m

Downspout cleanout type 1

17

Downspout cleanout type 2

18

Extension for downspoutcleanout type 2

19

400 mm

Downspout connector

20

15

Product group 3 Gutters & downspouts

Gutters & downspoutsDownspout skirt Standpipe bracket Standpipe 1,0 mDownspout Y-pipe

Hose

with male & female connector

500 mm

Downspout cleanout type 3 Offsett Vent pipe cap

Box gutter Stop end (box)

for adhesive bonding

Plug-in outlet (box)

Top fix rafter bracket (box)

Mount the brackets inintervals of 50-70 cm.

Fascia bracket (box)

Mount the brackets inintervals of 50-70 cm.

Gutter miter (box) Gutter connector (box)

Screws

required quantity: 3 pieces pertop fix rafter bracket/fascia bracket

GlueEaves tray no. 1 Eaves tray no. 2

Stop end (box)

for flanging / soldering

16

Product group 3 Gutters & downspouts

Ideal use of rainwaterDownspout cleanout type 2Downspout cleanout type 1

400 mm

Extension for downspoutcleanout type 2 Downspout cleanout type 4

less effort and little expense

durable high-quality material

suitable for all common downspouts

simple and quick installation

frost-proof

decrease of drinking-waterconsumption

cross-section cross-section

conventional layingrecommended laying for

overlapping roof tiles

SAREI’s gutter leaf guard protects your gutter from clogging caused by foliage and other debris.Thus it can help in preventing expensive maintenance costs.

Due to its flexibility it is suitable for almost every gutter size.

The installation is very simpel and convenient: Just fold and bend the gutter leaf guard, lay it into thegutter and clamp it with the integrated clips. There is no additional mounting material required.If necessary, you can connect several pieces by putting them together.

Gutter leaf guard

One set (4 pieces) is sufficient for 2,32 m gutter lengh.

Integrated clip system

Material: Polypropylen (UV-stabilized, frost-resistant)

Colour: grey

Size: gutter width 90-150 mm

EAN: 42 600 3689 4608

17

Product group 3 Gutters & downspouts

Gutter heatingIdeal frost protection for your gutter

- keeps your gutter free of ice and snow

- avoids icicles & frost damages

- durable high-quality material

Default lenghts:

5 m 10 m 15 m 20 m 25 m 30 m 35 m

For special lengths send an enquiry.

Installing instructions:

It is recommended to heat downspouts, which are placed in areasthreatened by frost, down to 1 m into the ground.

Internet: www.rinnenfrei.deProduktionsstätteD e u t s c h l a n d

18

Half-round gutter Type Diameter Radius Area A

333 mm

285 mm

250 mm

200 mm

approx. 150 mm

approx. 125 mm

approx. 100 mm

approx. 80 mm

76,5

63,5

52,5

40

92 cm²

63 cm²

43 cm²

25 cm²

diameter

Box gutter Type side lengths Area A

333 mm

250 mm

200 mm

90 cm²

42 cm²

28 cm²

a b c

75 mm

55 mm

42 mm

120 mm

85 mm

70 mm

85 mm

65 mm

50 mm

Product group 3 Gutters & downspouts

Size chart

19

Product group 4 Roofing materials

Roofing materialsMetal ridge vent

natural Aluminium, colouredaluminium, zinc, copper

Chimney flashing

galvanized sheet steelzinc, copper

Alu-Flex 5,0 m

wall & chimney flashing tapestructured

anthracite, brick-red, grey

Round timber snow-guard 2,0 m

boiler-pressure impregnated

Snow-guard

lenght: 1,5 m & 3,0 mgalvanized, colour coated,

copper

Safety grating

galvanized, colour coated,copper

Snow-guard bracket for round timber

galvanized, colour coated, copperMount the snow-guard brackets in intervals of approx. 70 cm.

Snow-guard bracket no. 1

galvanized, colour coated, copperMount the snow-guard brackets in

intervals of approx. 60 cm.

Safety grating bracket

galvanized, colour coated, copperMount the brackets in

intervals of approx. 90 cm.

Ladder hook

galvanized, colour coated,copper

Snow-guard bracket no. 2

galvanized, colour coatedincl. snow protection

Mount the snow-gurard brackets inintervals of approx. 60 cm.

Snow stop

black/red/brownuniversal

for all types of roof tiles20

Product group 4 Roofing materials

Roofing materialsBird control spikes type 1

2 rowslenght: 333 mm

mounted on polycarbonate strip

Bird control spikes type 2

6 rowslength: 333 mm

mounted on polycarbonate strip

Bird control spikes type 3

2 rowslength: 500 mm

mounted on high-grade steel strip

Vent pipe flashing

black / red / brownfor roof slates / roof tiles

Ventilation strip 5,0 m

width: 100 mmwhite, brown

black, brick-red

Flexible connection for pipes

Ø 100 mm, length: 500 mmmaterial: PVC

Eaves comb 1,0 m

height: 55 - 65 mmanthracite, brick-red

Moss stop 5,0 m

width: 200 mmcopper

Ridge & hip flashing roll 5,0 m

width: approx. 320 mmwith spunbond

anthracite, brick-red

High-grade steel screws withrosettes and rubber washer

4,5 x 35 mmhigh-grade steel, colour coated, copper-plated

clout nails

2,8 x 25 mmgalvanized, copper

Annular ring shank nails

6 x 80 mmgalvanized

required quantity: 3 pieces per snow-guardbracket / safety grating bracket / ladder hook

21

Product group 4 Roofing materials

bird control spikes type 1

2 rowslength: 333 mm

mounted on polycarbonate strip- max. cornice depth: 120 mm

6 rowslength: 333 mm

mounted on polycarbonate strip- max. cornice depth: 180 mm

bird control spikes type 2

2 rowslength: 500 mm

mounted on high-grade steel strip- max. cornice depth: 120 mm

bird control spikes type 3

for gutterssimple clip system

lenght: 45 mm1 bag = 5 clips

- unsuitable for copper gutters

bird control spikes type 4

Bird controlThe purpose of bird control spikes is to keep birds away from buildings toavoid great damages caused by corrosive bird faeces.

The bird control spikes can be installed on roofs, wall copings and cornices.

Fasten with special SAREI spike adhesive. One tube is sufficient for approx.12 meters.

Due to resiliently flexible spring steel there is no risk of injury for the birds!

22

Product group 5 Window sills

Aluminium window sills

Installation instructions

- cut the window sill to desired length - press on matching window sill end caps

step 2:

step 3:

- apply sound insulation tape* & sealing rubber

* reduces pounding noises of rain

- intervals between screws approx. 300 mm- (pre-drill Ø 4 mm)- press on screw caps

step 4:

step 1:

Information- protecting the building against weather conditions

- proper window sills for every application

aluminium 1,5 mmpolyester paint (coating thickness on upside: 25 µ)

RAL 9016 whiteRAL 9006 white aluminium (silvery)RAL 8014 sepia brown

Please send an enquiry, if you are interested in other materials or colours!

- suitable for new buildings and renovations

Material:

Default colours:width

25 mm

40 mm

23

Mittelbacher Str. 1209224 ChemnitzGERMANY

Tel.: 0049 (0) 371 - 842430Fax: 0049 (0) 371 - 8424319

[email protected]

With compliments: