26
Oct-15 Dr. A.Helba CIV 416 E 1 A Guide to Designing Reinforced Concrete Water Tanks Helba Alaa Dr. Examples of tank Sections Resisting Tension Tank Sections Resisting Tension and Moments General Design Requirements for Tank Elements Analysis and Design of R.C. Sections under T&M With tension on water side. (Uncracked Sections) Appendix: Solved Examples Lecture 2 & 3

Upload: others

Post on 20-Oct-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

  • Oct-15

    Dr. A.Helba CIV 416 E 1

    A Guide to Designing Reinforced Concrete Water Tanks

    Helba AlaaDr.

    Examples of tank Sections Resisting Tension

    Tank Sections Resisting Tension and Moments

    General Design Requirements for Tank Elements

    Analysis and Design of R.C. Sections under T&M

    With tension on water side. (Uncracked Sections)

    Appendix: Solved Examples

    Lecture 2 & 3

  • Oct-15

    Dr. A.Helba CIV 416 E 2

    Example of Cylindrical Wall of Water Tank in Hal direction

    Wall SEC. PLAN Wall SEC. ELEV.

    D H r Water Pressure

    Sections Resisting Tension

    T T

    r

    R

    T = r R

    1 m

    t

    R

    Ring tension T in Cylindrical Wall

    t h

  • Oct-15

    Dr. A.Helba CIV 416 E 3

    Water Pressure on Walls and Floor of an elevated Tank

    rests on columns

    Sec. Elev.

    Sections Resisting Tension and Moments

    Final B.M.D. on Walls and Floor

    Critical Sections in Tank Structural Elements

    (walls & Floors)

  • Oct-15

    Dr. A.Helba CIV 416 E 4

    Sections 1 & 4 Tension due to Moment is on Air-Side (Cracked Sections)

    Open Tank B . M . D

    1

    4

    2 3

    Sections 2 & 3 Tension due to Moment is on Water-Side (UnCracked Sections)

    1

    4

    2

    3

    B.M.D. on Walls and Floor

  • Oct-15

    Dr. A.Helba CIV 416 E 5

    General Design Requirements for Tank Elements (Uncracked Sections)

    • Consider Condition I (Tension on Water side)

    1- For serviceability requirement (no cracks at

    the liquid side ) ,Design a section To satisfy:

    ctrct

    ff

    ct ct(N) ct(M)

    T Mf = f +f +

    A Z

    cuctr

    η coeff. 1 from code

    table(4-16)

    0.6 ff =

    2- To Control the crack width (wk)

    • USE - according to ECP Code 203 tables 4-13 , 4-14 and 4-15 – the appropriate :

    - concrete cover (from table 4-13)

    - type/diam./stress of steel.

    ( from tables 4-14 and 4-15)

  • Oct-15

    Dr. A.Helba CIV 416 E 6

    Control of crack width

    ECP Code 203 Recommendations

    Table 4-11 Code

    Control of crack width ECP Code 203 Recommendations

  • Oct-15

    Dr. A.Helba CIV 416 E 7

    Control of crack width ECP Code 203

    Recommendations

    Control of crack width

    ECP Code 203 Recommendations

  • Oct-15

    Dr. A.Helba CIV 416 E 8

    Control of crack width ECP Code 203 Recommendations

    Control of crack width ECP Code 203 Recommendations

  • Oct-15

    Dr. A.Helba CIV 416 E 9

    Analysis and Design of R.C. Sections

    - Under T only - Under M only - Under T & M

    Controlling Tensile Strength of Concrete according to Egyptian Code

    • Water Tanks are classified as type 3 or 4 in CODE Table (4-8).

    • The maximum tensile stress of concrete is given by CODE Eq. (4-69) as follows :

    ( ) ( )[ ] /ct ct N ct M ctrf f f f

  • Oct-15

    Dr. A.Helba CIV 416 E 10

    fct(N) is the tensile stress due to unFactored axial tension

    (+ve sign for tension and –ve sign for comp.)

    where :

    As = all steel area

    and Assume

    ( )ct N

    c s

    Tf

    A nA

    10s

    c

    En

    E

    • fct(M) is the tensile stress due to unFactored moment

    (+ve sign for tension and –ve sign for comp.)

    ( ) 2 2

    6

    / 6ct M

    M M Mf

    Z bt b t

  • Oct-15

    Dr. A.Helba CIV 416 E 11

    Tensile Strength of Concrete according to Egyptian Code

    • is a reductuon coefficient given in code table (4-16) and depends on the ideal (virtual) thickness of the section (tv) , where

    0.6 cuctr ff

    ( )

    ( )

    [1 ]ct N

    v

    ct M

    ft t

    f

    Values of coefficient Table (4-16) Code

    tv(mm) 100 200 400 ≥ 600

    1 1.3 1.6 1.7

    fcu Values of (N/mm2)

    20 2.68 2.06 1.68 1.58

    25 3 2.31 1.88 1.76

    30 3.29 2.53 2.05 1.93

    /ctrf

  • Oct-15

    Dr. A.Helba CIV 416 E 12

    Calculation of steel rft. As required in Design

    of R.C. Sections - I - Under T only - II - Under M only - III - Under T & M (e=M/T =big ecc.) - IV - Under T & M (e = small ecc.)

    Use Steel to resist all tension (neglect concrete resistance in tension)

    us

    y

    cr

    s

    TA

    f

    I - Case of axial tension ( T only)

    1.4

    1.6

    u f

    f

    f

    T T

    for water pressure

    for other loads

    where

    T

    1

    2sA

    1

    2sA

    1

    2sA

    1

    2sA

    TIE section

  • Oct-15

    Dr. A.Helba CIV 416 E 13

    Consider a Cylindrical Wall of Water Tank

    Wall SEC. PLAN Wall SEC. ELEV.

    D H r Water Pressure

    T T

    r

    R

    T = r R

    1 m

    t

    I - Case of pure tension ( T only)

    R

    Ring tension in Cylindrical

    Wall t h

  • Oct-15

    Dr. A.Helba CIV 416 E 14

    Ring Steel in

    Cylindrical Wall

    T T

    r

    D 1 m

    t

    1

    2sA

    1

    2sA

    I - Case of Ring tension ( T only)

    T = r R = r D/2

    r = wh

    h

    II - Case of pure flexure (M only)

    ,

    12

    us

    y

    cr

    s

    M aA

    f dd

    M sA

    .cross Sec

    1 1 3 R 2( )cu

    c

    f

    uR M bd

  • Oct-15

    Dr. A.Helba CIV 416 E 15

    Calculate Mus = Tu(e + t/2 - d) or = Mu – Tu(d – t/2)

    Cases of eccentric tension (M &T)

    u

    u

    M e =

    T 2 III

    tCase of

    M

    sA T

    T(eccentric) e

    .cross Sec

    III – Case of big eccentric tension

    u

    u

    M e=

    T 21

    2

    us us

    y y

    cr cr

    s s

    M T tA if

    f fd

    Where Mus = Mu – Tu(d – t/2)

    sA T

    T(eccentric) e

    .cross Sec

  • Oct-15

    Dr. A.Helba CIV 416 E 16

    u

    u

    M e =

    T 2

    tC se oV fI a

    M

    T T(eccentric) e

    1sA

    2sA

    2se

    1se

    'd

    'd d

    .cross Sec

    IV – Case of small eccentric tension

    1 21 2,

    u us s

    y y

    cr cr

    s s

    T TA A

    f f

    1sA

    2sA

    Teccentric T e

    Calculate Tu1 = Tu / 2 + Mu / (d – d’)

    Tu2 = Tu / 2 - Mu / (d – d’)

    u

    u

    M e =

    T 2

    tC se oV fI a

    .cross Sec

  • Oct-15

    Dr. A.Helba CIV 416 E 17

    •Steps :

    1- assume t and check fct 2- calculate As

    Design of Uncracked Sections

    Step (1) for Slabs and Walls • b = 1 m = 1000 mm Assume t as follows :

    If T (in kN) only mm

    • If M only M in (kN.m) mm

    If M & T mm

    0.6t T

    50t M

    50 50t M

    For practical considerations tmin = 150 mm

  • Oct-15

    Dr. A.Helba CIV 416 E 18

    Step (1) for Sections (b X t) (Beams) • Assume t as follows :

    - for T only [ T in (N) ] mm

    - for M only M in (N.mm) mm

    - For M & T mm

    0.6T

    tb

    1.6M

    tb

    1.6 50M

    tb

    Step (1)b

    • Check fct (tensile stress) For any case :

    2

    ( ) ( )

    ( ) ,

    ( )/ 6

    [ ] /

    ct

    c

    ct

    ct ct N ct M ctr

    Tf N

    A

    Mf M

    bt

    f f f f

  • Oct-15

    Dr. A.Helba CIV 416 E 19

    Step (2) • Calculate As as follows : • case (I) T only mm2

    • case (II) M only

    us

    y

    cr

    s

    TA

    f

    12

    us

    y

    cr

    s

    MA

    fd

    21 1 3 ,

    /

    u

    cu c

    Mawhere R R

    d bd f

  • Oct-15

    Dr. A.Helba CIV 416 E 20

    • Check m ≥ mmin (steps 1 to 4 in sequence)

    Note:

    If mcal ≥ mmin (steps 1 and 2) , No need to do step 3)

    min

    0.2251 #

    max. #* 1.1

    2 #

    3 1.3 /

    max. * 4* 0.25% . .240 / 350

    4* 0.15% . .360 / 520

    cu

    y

    y

    s

    f

    fthe of

    the smaller of

    f

    A bd

    the of st Gr

    or st Gr

    m

    Minimum Val RFT. for Walls

  • Oct-15

    Dr. A.Helba CIV 416 E 21

    Step (2) • Calculate As as follows :

    • case (III) T & M and e ≥ t/2

    12

    us us

    y y

    cr cr

    s s

    M TA

    f fd

    21 1 3 ,

    /

    us

    cu c

    MaR R

    d bd f

    Where Mus = Mu – Tu(d – t/2)

    Step (2) • case (IV) T & M and e < t/2

    1 21 2,

    u us s

    y y

    cr cr

    s s

    T TA A

    f f

    Where Tu1 = Tu / 2 + Mu / (d – d’)

    Tu2 = Tu / 2 - Mu / (d – d’)

  • Oct-15

    Dr. A.Helba CIV 416 E 22

    Appendix

    Solved Examples

    on Design of different Uncracked Sections

    With conc. of fcu=25 N/mm2 & steel grade 360/520

    Design tank wall sections to resist the following cases:

    1- T = 150 kN

    2- M = 30 kN.m

    3- T = 150 kN and M = 60 kN.m

    4- T = 150 kN and M = 15 kN.m

    Solution:

    for concrete fctr = 0.6 fcu = 3 N/mm2

    for wall b = 1 m = 1000 mm

    Examples on Design of Uncracked Sections

  • Oct-15

    Dr. A.Helba CIV 416 E 23

    1- Case of T = 150 kN

    Solution:

    Assume twall = 0.6 T = 90 mm < tmin = 150 mm

    Chosen twall = 150 mm

    Check tensile stress:

    Calculate fct :

    fct = fctN + fctM = T/Ac + M/Zc = T/(b x t) + M/(bt2/6)

    = 150000/(1000 x 150) + 0 = 1 + 0

    = 1 N/mm2

    Calculate fctr/ :

    tv = t (1 + fctN / fctM) = ∞ then = 1.7

    fctr/ = 3 / 1.7 = 1.76 N/mm2

    Check: as fct < fctr/ chosen t = 150 mm is O.k

    Design of Uncracked Sections – Case # 1

    Calculation of As in Case of T = 150 kN

    As = Tu / (cr fy/s) - [ for bars 10 mm - cr = 0.93]

    = 1.4 x 150 x 1000 / (0.93 x 360/1.15)

    = 721.33 mm2

    Use 5 10 /m’ on each side (As= 2 x 395 = 790 mm2)

    Check As min

    As min = 0.15 % Ac = 0.15 x b x t /100 = 1.5 t (for walls)

    As > As min O.k

  • Oct-15

    Dr. A.Helba CIV 416 E 24

    2- Case of M = 30 kN.m

    Solution:

    Assume twall = 50 𝑀 = 50 30 = 274 mm

    Try twall = 300 mm

    Check tensile stress:

    Calculate fct :

    fct = fctN + fctM = T/Ac + M/Zc = T/(b x t) + M/(bt2/6)

    = 0 + 6 x 30 x 106 / (1000 x 3002) = 0 + 2

    = 2 N/mm2

    Calculate fctr/ :

    tv = t (1 + fctN / fctM) = t = 300 mm from table = 1.45

    fctr/ = 3 / 1.45 = 2.07 N/mm2

    Check: as fct < fctr/ chosen t = 300 mm is O.k

    Design of Uncracked Sections – Case # 2

    Calculation of As in Case of M = 30 kN.m

    Calculate As :

    As = Mu / [(cr fy/s)(0.95d)] [ use a = 0.1 d]

    = 1.4 x 30 x 106 / [(0.93 x 360/1.15)(0.95 x 260)] = 584 mm2

    Use 8 10 /m’ on tension side (As= 632 mm2)

    Check As min

    As min = 0.15 % Ac = 1.5 t = 450 mm2

    As > As min O.k

  • Oct-15

    Dr. A.Helba CIV 416 E 25

    3- Case of T = 150 kN and M = 60 kN.m

    Assume twall = 0.6 T = 90 mm

    Assume twall = 50 𝑀 + 50= 50 60 + 50 = 437 mm

    Try twall = 500 mm

    Check tensile stress:

    Calculate fct :

    fct = fctN + fctM = T/Ac + M/Zc = T/(b x t) + M/(bt2/6)

    = 150 x 103 /(1000 x 500) + 6 x 60 x 106 / (1000 x 5002)

    = 0.3 + 1.44 = 1.74 N/mm2

    Calculate fctr/ :

    tv = t (1 + fctN / fctM) = t (1 + 0.3 / 1.44) = 1.21 x 500 = 605 mm > 600 mm then = 1.7

    fctr/ = 3 / 1.7 = 1.76 N/mm2

    Check: as fct > fctr/ chosen t = 500 mm is O.k

    Design of Uncracked Sections – Case # 3

    Calculation of As in Case of T = 150 kN and M = 60 kN.m

    e = M / T = 400 mm > t / 2 = 250 mm Large ecc.

    Calculate Ms :

    Ms = T (e – t / 2 + d’)

    = 150 (400 – 250 + 40) / 1000

    = 28.5 kN. m

    Calculate As :

    As = Mus / [(cr fy/s)(0.95d)] + T1u / (cr fy/s) [ use a = 0.1 d]

    = 1.4 x 28.5 x 106 / [(0.75 x 360/1.15)(0.95 x 460)]

    + 1.4 x 150 x 1000 / (0.75 x 360/1.15) = 388.9 + 894.4 = 1283 mm2

    Use 7 16 /m’ on tension side

  • Oct-15

    Dr. A.Helba CIV 416 E 26

    4- Case of T = 150 kN and M = 15 kN.m

    Solution:

    Design of Uncracked Sections – Case # 4

    Assume twall = 0.6 T = 90 mm

    Assume twall = 50 𝑀 + 50= 50 15 + 50 = 244 mm

    Try twall = 250 mm

    Check tensile stress: Calculate fct :

    fct = fctN + fctM = T/Ac + M/Zc = T/(b x t) + M/(bt2/6)

    = 150 x 103 /(1000 x 250) + 6 x 15 x 106 / (1000 x 2502)

    = 0.6 + 1.44

    = 2.04 N/mm2

    Calculate fctr/ :

    tv = t (1 + fctN / fctM) = t (1 + 0.6 / 1.44) = 1.42 x 250 = 355 mm then = 1.53

    fctr/ = 3 / 1.55 = 1.94 N/mm2

    Check: as fct > fctr/ Not O.k increase t (try t = 300 mm)

    Recheck: as fct > fctr/ chosen t = 300 mm is O.k

    Calculation of As in Case of T = 150 kN and M = 15 kN.m

    e = M / T = 100 mm < t / 2 = 150 mm Small ecc.

    Calculate T1 and T2 :

    T1 = 150/2 + 15/(0.26 – 0.04) = 143.2 kN

    T2 = 150/2 - 15/(0.26 – 0.04) = 6.8 kN

    Calculate As1 and As2 : As1 = T1u / (cr fy/s)

    = 1.4 x 143.2 x 103 / (0.93 x 360/1.15) = 689 mm2

    Use 9 10 /m’ or 7 12 /m’ on tension side ❶(As=711 mm2)

    As2 = T2u / (cr fy/s)

    = 33 mm2 < Asmin = 1.5 t

    Use Asmin 5 10 /m’ on tension side ❷(As= 395 mm2)

    ❷ T1 = T / 2 + M / (d – d’)

    2 _