  • Manual Converter Module UV-14

    A_EN_05806_00D1

    Magnetic Inductive Flowmeter

    Converter Module UV-14 Version : 001

    Description

    The converter module UV-14 is for the connection the transmitter families MDS and NFD on a PLC.

    The module converts the voltages, coming from the transmitter, in a pulse frequency proportional to the flow. The output frequency is set to 50 kHz at 10 m/sec..Additional to the pulse output a signal Zero point O.K. is available.

    For controlling the functions of the converter card a signal from the status of the valve and a signal for starting the calibration of zero point is necessary.

    A dynamic pulse shut off function is installed, which is controlled from the status signal of the valve.

    The zero point setting can be activated with a external input.

    During the batch is running it is possible to control the zero point which was set in this time the valve was opening.

    The converter module is for installation on a DIN Rail.

    Bopp & Reuther Messtechnik GmbHAm Neuen Rheinhafen 467346 Speyerwww.bopp-reuther.de

  • Manual Converter Module UV-14

    M_GB_05806_00D2

    Technical Data

    Housing DIN- Rail mounted acc. DIN EN 60715 Wide 35 mmProtection class IP 20Power Supply Nominal 24 VDCPower Supply range 18 VDC to 36 VDCNoise < 1%Current consumption max. 100 mA at 24 VDCAmbient temperature 0 to 50 CHumanity 50%

    Measuring Range

    Full scale 10 m/sec.

    Accuracy at reference conditions

    10-100% of full scale 0,5% of real value0-10% of full scale 0,5% of real value 0,01% of full scale

    Repeatability 0,1% of real value 0,005% of full scale

    Pulse output

    Frequency max. 50 kHzPulse wide 10 sec.

    Digital inputs isolated via optocoupler

    Input voltage range same as Power Supply rangeHigh- Level > 10 VDCLow- Level < 5V VDCInput resistance 2,4 kOhm

    Digital outputs isolated via optocoupler

    Output voltage range same as Power Supply range high sides witch 20mA max.short- circuit proof

    K-factor depending of diameter of the transmitter

    DN pulses / l

    10 6366015 2829320 1591525 1018532 621640 3978

  • Manual Converter Module UV-14

    M_GB_05806_00D3

    Function of In- and Outputs

    Outputs

    Volume pulses

    The output frequency is 50 kHz at 100 % Full scale and the pulse length is 10s.

    A pulse standardizing is not implemented. For the calculation of the preset value the k-factor must be selected depending of the diameter of the Flowmeter.

    Example:

    Diameter DN 15K-Factor for DN15 28293 pulses/LBatch quantity 100mL

    Preset for counter = 0,1L x 28293 pulses / L = 2829 pulses

    Zero point O.K.

    The flow at the closed valve is always measured, after the flow have reached the half value of the flow rate in the time of closing the valve. If valve opens, the status of the last measuring is saved.

    Output " HIGH

    The output goes high, if the flow is < 1 % of full scale before the valve opens.

    Output " LOW

    The output goes low, if the flow is > 1 % of full scale before the valve opens.

    The output is saved during the valve is open ( Input valve open/ closed " LOW ). It is therefore possible, to control the zero point during the valve is open and start- if the zero point is wrong- a zero point setting at the next dosing cycle.

    Inputs

    Valve OPEN / CLOSED

    This input control the switch off of the pulse output

    Controlling

    Valve open : Input "HIGH"Valve closed : Input "LOW

    If the input is LOW , then the pulse output is closed if :

    - the flow goes constant or- the flow have a oscillation

  • Manual Converter Module UV-14

    M_GB_05806_00D4

    Zero Point

    With the input Zero Point the zero point setting can be started.

    The adjustment of the Zero Point is always automatically.

    Input HIGH Zero Point setting activated, LED Zero Point is ONInput LOW Zero Point setting deactivated, LED Zero Point is OFF

    Zero Point setting is only possible if

    - The dosing valve is closed and- The pulse output is switched off.

    If the Zero point is calibrated correctly, the LED FLOW must be off. The PLC can also control the output Zero Point O.K. .

    Fuse for Power Supply 24 VAC for transmitter

    To protect the Converter Module a fuse between the Power Supply 24 VAC and the wires red / blue is installed.The Fuse is soldered on the printed circuit. The value of this fuse is 630 mA Time Lag T.

    DisplayIn front of the module 4 LED are installed24VDC LED is ON, if 24VDC is connected on terminal connectors 6 and 1224VAC LED is ON, if 24VAC is connected on terminal connector 10 and 11. The LED can anyway be

    OFF if the internal Fuse is damaged.FLOW LED is ON, if the flow is > 0,5% of full scaleZEROPOINT LED is ON, if the calibration of the Zero Point is active.

  • Manual Converter Module UV-14

    M_GB_05806_00D5

    + 24

    VD

    C

    24 VA

    C / 5

    0-60

    Hz

    -24

    VD

    C / G

    rou

    nd

    blu

    e

    red

    bro

    wn

    whi

    te

    gree

    n

    yello

    w

    Valv

    e o

    pen

    / c

    lose

    d

    Zero

    Po

    int

    Zero

    Po

    int O

    .K.

    Volu

    me

    Puls

    es

    Measuring cable

    24 VDC

    FLOW

    ZERO

    24 VAC

    INPUTS OUTPUTS

    Terminal connector2nd level

    Terminal connectortop level

    7 8 9

    1 2 3 4 5 6

    10 11 12

    13 14 15

    16 17 18

  • Manual Converter Module UV-14

    M_GB_05806_00D6

    =

    + / - 15VDC

    Fuse 0,63A Time Lag T

    RedBlue

    Shield

    White

    Brown

    Green

    Yellow

    612

    1011

    4

    5

    2

    1

    3

    7

    9

    13

    14

    17

    16

    Me

    sska

    bel

    + / - 15 VDC

    Valve open / closed

    Zero Point

    Volume Pulses

    Zero Point O.K.

    24VDC

    24VAC

    Optocoupler

    PLC

    Inpu

    tsO

    utp

    uts

    UV-14

    +

    -

  • Manual Converter Module UV-14

    M_GB_05806_00D7

    Volu

    me

    Puls

    esFl

    ow

    Valve closing ( = 100% )

    50%

    Flow constant or goes higher

    Pulse output switched ON

    Pulse output switched OFF

    Valv

    e o

    pen

    / c

    lose

    d

    Valve closed

    Zero

    Po

    int

    Zero

    Po

    int s

    ettin

    g

    Zero Point setting and pulse output switching

    Zero

    Po

    int O

    .K.

  • Manual Converter Module UV-14

    M_GB_05806_00D8

    Volu

    me

    Puls

    esFl

    ow

    Valve closing ( = 100% )

    50%

    Flow is constant or goes higher

    Pulse output switched ON

    Pulse output switched OFF

    Valv

    e o

    pen

    / c

    lose

    d

    Valve closed

    Zero

    Po

    int

    Zero

    Po

    int S

    ettin

    g

    Zero Point setting and pulse output switching : Zero Point wrong

    Zero

    Po

    int O

    .K.

    Zero Point > 1% , must be calibrated

  • Manual Converter Module UV-14

    M_GB_05806_00D9

    Volu

    me

    puls

    esFl

    ow

    Valve closing ( = 100% )

    50%

    Flow is constant or goes higher

    Pulses output switched ON

    Pulses output switched OFF

    Valv

    e o

    pen

    / c

    lose

    d

    Valve closed

    Zero

    Po

    int

    Zero

    Po

    int S

    ettin

    g

    Controlling output Zero Point O.K. and activation of Zero Point setting

    Zero

    Po

    int O

    .K.

  • Manual Converter Module UV-14

    M_GB_05806_00D10

    Volu

    me

    puls

    esFl

    ow

    Valve closing ( = 100% )

    50%

    Flow is constant or goes higher

    Pulse output switched ON

    Pulse output switched OFF

    Valv

    e o

    pen

    / c

    lose

    d

    Valve closed

    Updating output Zero Point O.K.

    Zero < 1%Zero > 1%Zero

    po

    int O

    .K.

    Output Zero Point O.K :

    Zero < 1%