a elevators for people with reduced mobility - inicio dksa_ang.pdf · inauxa comercial s.a. d a d a...
TRANSCRIPT
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
D
A
D
AElevators forpeople withreduced mobility(PEV - PMR)
D
A
D
AA SOLUTION FOR ANY HOUSE
The company
Dksa is thought to make you able to enjoy allour technology and experience asmanufacturers, comfortably at your home.
Our equipment is thought to have a fast andeasy installation, always with our integralphilosophy. Our commercial department willtake charge of everything.
Forget the need for contact with architects,manufacturers, installers, apply for permits ...with INAUXA you may have the solution.
Where to put an DKSA elevator
Upgrade your house by installing ourequipment DKSA. Enjoy the latestadvancements in design. We adapt it to thestyle of your home. We are manufacturers andwe can make the product to yourrequirements.
Do not wait until it becomes a need, enjoynow the luxury of being able to move easilybetween building floors.
PEV PMR- - Vertical lift platform for people with reduced mobility
www.inauxacomercial.com
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
Why a DKSA elevator
A SOLUTION FOR ANY HOUSE
The installation of an elevator, besideimproving the quality of daily life, increasesthe economic value of the building.
Our team will advise you to find the bestsolution, as for facilities in new constructionsas well as for refurbishments, always thinkingabout a definitive solution.
A luxury accessible to everybody. The Dksaelevator is a solution to overcome architecturalbarriers in residential and public spaces, insituations of reduced mobility both temporaryand permanent.
The Dksa elevator is thought to be able tomove comfortably between floors in privatehouses, commercial premises, publicorganisms, schools, offices, …
The Dksa elevator facilitates the mobility indaily situations: senior citizens, pregnantwomen, baby prams, wheelchairs, shoppingbags, heavy packages, etc.
DKSA
D
A
D
A
CE Certificationnumber1081- MA/B2006/42/CE Relative tothe machines
Flip-top ceiling:temporary LEDSlightning
Non-slipping pavementand skirting boards instainless steel
Control panel
Mirror detail
Semi automatic door withpeephole
Handrails detail
Bright stainlesssteel push buttons
PEV PMR- - Vertical lift platform for people with reduced mobility
www.inauxacomercial.com
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
Landing and cabin doors
COMPONENTS
Automatic telescopic doorsGlass and Metal
Automatic telescopicdoors Diamond Bus type doors
Semi-automatic blinddoor
Semi-automatic doorwith peephole
Semi-automatic door withlarge peephole
Automatic telescopicdoors
D
A
D
ACOMPONENTS
Mirror in the cabin
Black dotted rubberPVC GrayPVC Black PVC Beige
R10 Salmon A2V CreamV14 Green N1 Grey
Colors acabat panell cabina
PPS14 GreyPPS31 BluePPS17 Black
PEV PMR- - Vertical lift platform for people with reduced mobility
Colours of the cabin pavement finishings
www.inauxacomercial.com
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
LED focused timer in cabin to switch off light when lift isnot in use'(very low consumption)Without doors in cabinOperation by means of supported pulsation accordingto the machine guidelineDouble photoelectric safety curtainSemi-automatic landing door with or without peephole,primer finishingSafety lock in doors according to En81Manoeuvre controlled by PLCGuide rail panels of 5mParachute according to En81Wedging for cable breakDevice to control a fast descent in cabinSafety valve partly hydraulicWeight overload limiter with optical and acoustic indicatorDevice for emergency descent (manual rescue)Manual pump in hydraulic power plantUPS of emergency for power cut (electrical rescuemaintained push)Safety contact for trajectory endLímit físic d'excés de recorregutTap for hydraulic closureAutomatic lighting in cabin in case of emergencyControl devices according to EN81-41For doors without peephole: indication of present cabinon the floorAlarm push buttonEmergency stop in cabinEmergency stop in pitControl disconnection key in cabin and floorTelephone in cabinIndication of "operation" in landing push buttonsRemovable cabin side for maintenanceFlip-top ceilingSingle-phase supply voltage to 220/230/240 V2 CV or 3 CV single-phase motor
(programmable automation)
Maximum safety and energetic saving (standard equipment)
TECHNICAL FEATURES
D
A
D
A
Closet machine roomAccess ramp to cabin, metallic, for an elevatorwithout pitSelf-supporting structure of interior or exteriorhole, with pad, glass or combined finishing.Firing resistance of warm hydraulic oilThree-phase voltage supply to 380V/400V/415V2 CV or 3CV three-phase motor
Technical Service and advice to costumers andinstallers
TECHNICAL FEATURES
Options
Quality finishings (standard equipment)
Cabin finished in SkinplateNon-slipping PVC pavement in cabinSide handrails in cabinMirror in cabinBright stainless steel cabin push buttonsSkirting boards and snouts in stainless steelIlluminated control push buttonsLanding push buttons in stainless steel
Adjustment of the equipment to non standarddimensionsAutomatic telescopic or central cabin or landing doorsAutomatic doors bus in cabin·Automatic opening doors in case of electrical supplyfailureDoors finishing in epoxy, stainless steel, glazed orcomplete glassGlazed manual landing doorsPavements in granite, Silestone or preparation forspecial finishingPersonalized CabinCabin with panoramic panelsCeiling with stainless steel finishingDisplay in cabinDisplay in floorCodified KeyboardTelephone (keyboard) integrated to the cabinpush buttonsKit push-buttons Luxury rangeReopening doors push buttonGuide rail panels to 2,5mOil collector guides in pitBiodegradable and non-pollutant lubricant forhydraulic power plant
PEV PMR- - Vertical lift platform for people with reduced mobility
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
www.inauxacomercial.com
Speed:Payload Kg:Minimal pit:Minimal way out:Maximum travel:Motor power:Voltage:
Safety systems:
0,15 m/sec300Kg250mm
2450mm14m
2CV/3CV220V/230V/240V single-phase
380V/400V/415V three-phase
ParachuteParachute valveLocks doors En81Emergency battery
TECHNICAL FEATURES
VE
RT
ICA
L C
LEA
RA
NC
E D
OO
RS 2
00
0 m
m
WA
Y O
UT
/ L
AST
ST
OP
24
50
mm
MIN
IMU
MT
RA
VE
L
D
A
D
A
CABIN DOOR WITHOUT DOORS BUS TYPE TELESCOPIC 2D
PASSING CLEARANCE (PC)
HOLE WIDTH (WH)
HOLE DEPTH (HD)
CABIN WIDTH (CW)
CABIN DEPTH (CD)
MINIMAL MEASURES TRACTION SIDE / SINGLE ENTRY
HOLE WIDTH (WH)
HOLE DEPTH (HD)
Standard cabin 1000 x 1200
Minimal dimensions with standard material
TECHNICAL SCHEMES
700 800 900
1075 1175 1275
1000
775 875 975
800
700 800 900
1100 1200 1300
1000
800 900 1000
800
700 800 900
1250 1400 1550
1025
900 1050 1200
800
1290
1400
1290 1300
1400
1290 1400 1550
1425
PC
WH
HD
CD
CW
PC
WH
PC
WH
HD
CD
HD
CD
CW
CW
CABIN DOOR WITHOUT DOORS BUS TYPE TELESCOPIC 2D
PASSING CLEARANCE (PC)
HOLE WIDTH (WH)
HOLE DEPTH (HD)
CABIN WIDTH (CW)
CABIN DEPTH (CD)
700 800 900
950 1050 1150
1170
810 910 1010
800
700 800 900
950 1050 1150
1170
810 910 1010
800
700 800 900
1250 1400 1540
1195
1050 1150 1250
800
MINIMAL MEASURES TRACTION BOTTOM / SINGLE ENTRY
HOLE WIDTH (WH)
HOLE DEPTH (HD)
1120 1150
1570
1120 1150
1570
1250 1400 1550
1595
Standard cabin 1000 x 1200
PC
WH
HD
CD
CW CWCW
HD
CD
HD
CD
PC
WH
PC
WH
PEV PMR- - Vertical lift platform for people with reduced mobility
www.inauxacomercial.com
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
CABIN DOOR WITHOUT DOORS BUS TYPE TELESCOPIC 2D
PASSING CLEARANCE (PC)
HOLE WIDTH (WH)
HOLE DEPTH (HD)
CABIN WIDTH (CW)
CABIN DEPTH (CD)
700
800
900
1075 1175 1275
1080
775 875 975
700 800 900
1100 1200 1300
1080
800 900 1000
700 800 900
1250 1400 1550
1130
900 1050 1200
EMBARCAMENT 180º
800 800
800
HOLE WIDTH (WH)
HOLE DEPTH (HD)
1290
1480
1290 1300
1480
1290 1400 1550
1530
Standard cabin 1000 x 1200
CABIN DOOR WITHOUT DOORS BUS TYPE TELESCOPIC 2D
PASSING CLEARANCE (PC)
HOLE WIDTH (WH)
HOLE DEPTH (HD)
CABIN WIDTH (CW)
CABIN DEPTH (CD)
700 800 900
1145 1245 1345
775 875 975
700 800 900
1170 1270 1370
800 900 1000
700 800 900
1355 1500 1650
950 1050 1200
EMBARCAMENT 90º
1000 1100 1200
800 900 1000
1000 1100 1200
800 900 1000
1250 1400 1550
1010 1160 1310
HOLE WIDTH (WH)
HOLE DEPTH (HD)
1370
1400
1370
1400
1400 1500 1650
1425 1600
Standard cabin 1000 x 1200
Minimal dimensions with standard material
PC PCPC
WH WH WH
HD
HD
HD
CD
CD
CD
CW CW
CW
PC
WH
HD
CD
CW
HD
CD
CW
PC
WH
HD
CD
PC
WH
CW
INAUXACOMERCIAL S.A.
INAUXACOMERCIAL S.A.
Cardener, 3-1308670 Navàs,Barcelona - EspañaTel. +34 93 839 07 43+34 93 839 07 50 www.inauxacomercial.com