    11257 - A-100 CORROSION INHIBITOR

    SAFETY DATA SHEETA-100 CORROSION INHIBITOR

    1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY:

    PRODUCT NAME: A-100 CORROSION INHIBITOR

    APPLICATIONS: CORROSION INHIBITOR

    SUPPLIER: PT MILCHEM/BAKER HUGHES INTEQ

    THE GARDEN CENTRE, 6th FLOOR SUITE 07

    CILANDAK COMMERCIAL ESTATE, JALAN CILANDAK K.K.O.

    PO BOX 7508, JAKARTA 12560

    TELEPHONE: (62 21) 780 0737

    FAX: (62 21) 780 1682

    2. COMPOSITION/INFORMATION ON INGREDIENTS:

    CAS No.: CONTENT HEALTH: RISK:INGREDIENT NAME:67-63-0 5-10 %PROPAN-2-OL107-19-7 15-25 % T 23/24/25, 34PROPARGYL ALCOHOL

    3. HAZARDS IDENTIFICATION:

    Flammable.Harmful by inhalation, in contact with skin and if swallowed.Causes burns.

    4. FIRST AID MEASURES:

    GENERAL: No recommendation given, but first aid may still be required in case of accidental exposure, inhalation or ingestion ofthis chemical. If in doubt, GET MEDICAL ATTENTION PROMPTLY!

    INHALATION: Move the exposed person to fresh air at once. Keep the affected person warm and at rest. Get prompt medical

    attention.

    INGESTION: DO NOT induce vomiting. Get medical attention immediately. Promptly get affected personnel to drink largevolumes of water to dilute the swallowed chemical.

    SKIN: Wash the skin immediately with soap and water. Get medical attention if irritation persists after washing.

    EYES: Promptly wash eyes with plenty of water while lifting the eye lids. Continue to rinse for at least 15 minutes and getmedical attention.

    5. FIRE FIGHTING MEASURES:

    EXTINGUISHING MEDIA:Fire can be extinguished using: Powder, foam or CO2.

  • 8/13/2019 A-100 Corrosion Inhibitor

    2/4

    REVISION DATE: 23/8/96

    2 / 4

    11257 - A-100 CORROSION INHIBITOR REVISION DATE: 23/8/96

    2 / 4

    11257 - A-100 CORROSION INHIBITOR

    6. ACCIDENTAL RELEASE MEASURES:

    SPILL CLEANUP METHODS:Clean-up personnel should use respiratory and/or liquid contact protection. Extinguish all ignition sources. Avoidsparks, flames, heat and smoking. Ventilate. Stop leak if possible without risk. Absorb in vermiculite, dry sand or

    earth and place into containers.

    7. HANDLING AND STORAGE:

    USAGE PRECAUTIONS:Keep away from heat, sparks and open flame. Avoid spilling, skin and eye contact. Ventilate well, avoid breathingvapours. Use approved respirator if air contamination is above accepted level. Wear full protective clothing forprolonged exposure and/or high concentrations.

    STORAGE PRECAUTIONS:Keep in cool, dry, ventilated storage and closed containers. Flammable/combustible - Keep away from oxidizers, heatand flames.

    STORAGE CRITERIA:Flammable liquid storage.

    8. EXPOSURE CONTROLS AND PERSONAL PROTECTION:

    CAS No.: STD: LT EXP. 8 HRS: ST EXP. 15 MIN:INGREDIENT NAME:67-63-0 OES. 400 ppm 500 ppmPROPAN-2-OL

    107-19-7 OES. 1 ppm(Sk) 3 ppm(Sk)PROPARGYL ALCOHOL

    PROTECTIVE EQUIPMENT:

    VENTILATION: No specific ventilation requirements noted, except this product must not be used in a confined space without goodventilation.

    RESPIRATORS: Exposure should be avoided\controlled by ventilation or extraction if exposure limits are likely to be exceeded. Ifexcessive contamination exists Wear suitable chemical respirator.

    PROTECTIVE GLOVES:Use protective gloves made of: Rubber, neoprene or PVC.

    EYE PROTECTION:

    Wear approved safety goggles.

    OTHER PROTECTION:Wear appropriate clothing to prevent any possibility of skin contact.

    HYGIENIC WORK PRACTICES:Wash at the end of each work shift and before eating, smoking and using the toilet.

    9. PHYSICAL AND CHEMICAL PROPERTIES:

    APPEARANCE: Liquid.

    COLOUR:Dark. Brown.

    ODOUR/TASTE: Slight.

    SOLUBILITY DESCRIPTION: Soluble in water. Soluble in: Hydrocarbons. Miscible with water. Mineral acids (some).

    BOILING POINT (C, interval): 80 PRESSURE: 760mmHg

    MELT./FREEZ. POINT (C, interval):

  • 8/13/2019 A-100 Corrosion Inhibitor

    3/4

    REVISION DATE: 23/8/96

    3 / 4

    11257 - A-100 CORROSION INHIBITOR REVISION DATE: 23/8/96

    3 / 4

    11257 - A-100 CORROSION INHIBITOR

    DENSITY/SPECIFIC GRAVITY (g/ml): 0.97 TEMPERATURE (C): 20

    pH-VALUE, CONC. SOLUTION: 3.5

    VISCOSITY: 100 cps TEMPERATURE (C): 20

    FLASH POINT (C): 26 METHOD: P/M Pensky-Martens.

    10. STABILITY AND REACTIVITY:

    STABILITY: Normally stable.

    MATERIALS TO AVOID:Strong oxidizing agents.

    HAZARDOUS DECOMP. PRODUCTS:Fire or high temperatures create: Oxides of: Carbon. Nitrogen.

    11. TOXICOLOGICAL INFORMATION:

    INHALATION: Harmful by Inhalation. Corrosive, exposure can injure throat and lungs.

    INGESTION: Causes severe burns to mouth, throat and stomach Harmful by ingestion.

    SKIN: Harmful by skin absorbtion. Corrosive, causes skin burns which may result in tissue damage.

    EYES: May cause severe irritation, redness, tearing, blurred vision.

    12. ECOLOGICAL INFORMATION:

    ECOLOGICAL INFORMATION:LC50 (Arcartia tonsa) 29,400 mg/l

    EC50 (Skeletonema costatum) 1000 mg/lEC50 (Abra alba) 5126 ppm

    13. DISPOSAL CONSIDERATIONS:

    DISPOSAL METHODS:Dispose of in accordance with Local Authority requirements.

    14. TRANSPORT INFORMATION:

    LABEL FOR CONVEYANCE:

    ROAD TRANSPORT:

    UN No. ROAD: 2924

    ADR CLASS: 3ADR ITEM No.: 33(c)

    HAZCHEM CODE: 3XE

    CEFIC TEC(R) No.: 30G31

  • 8/13/2019 A-100 Corrosion Inhibitor

    4/4

    REVISION DATE: 23/8/96

    4 / 4

    11257 - A-100 CORROSION INHIBITOR REVISION DATE: 23/8/96

    4 / 4

    11257 - A-100 CORROSION INHIBITOR

    PROPER SHIPPING NAME I: FLAMMABLE LIQUID, CORROSIVE N.O.S

    RAIL TRANSPORT:

    RID CLASS No.: 3

    SEA TRANSPORT:

    UN No. SEA: 2924

    IMDG CLASS: 3

    IMDG PAGE No.: 3346IMDG PACK GR.: III

    EmS No.: 3-02

    MFAG TABLE No.: 760

    MARINE POLLUTANT: No.

    AIR TRANSPORT:

    UN No., AIR: 2924

    ICAO CLASS: 3

    AIR SUB CLASS: 3

    AIR PACK GR.: III

    15. REGULATORY INFORMATION:

    LABEL FOR SUPPLY:

    RISK PHRASES: R-10 Flammable.R-34 Causes burns.R-20/21/22 Harmful by inhalation, in contact with skin and if swallowed.

    SAFETY PHRASES: S-16 Keep away from sources of ignition - No Smoking.

    S-36/37/39 Wear suitable protective clothing, gloves and eye/face protection.S-24/25 Avoid contact with skin and eyes.S-45 In case of accident or if you feel unwell, seek medical advice immediately (showthe label where possible).

    UK REGULATORY REFERENCES: Chemicals (Hazard Information & Packaging for Supply) Regulations 1994

    16. OTHER INFORMATION:

    REVISION COMMENTS: Data Sheet conforms to CHIP Regulations.

    REVISION DATE: 23/8/96

    DATE: 14th June 1995

    THIS SDS IS PRODUCED WITH SAFECHEM for WINDOWS

    DISCLAIMER:THIS INFORMATION RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR SUCH MATERIALUSED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY PROCESS. SUCH INFORMATION IS, TO THE REST OF THECOMPANY'S KNOWLEDGE AND BELIEF, ACCURATE AND RELIABLE AS OF THE DATE INDICATED. HOWEVER, NO WARRANTY,GUARANTEE OR REPRESENTATION IS MADE AS TO ITS ACCURACY, RELIABILITY OR COMPLETENESS. IT IS THE USER'S

    RESPONSIBILITY TO SATISFY HIMSELF AS TO THE SUITABILITY OF SUCH INFORMATION FOR HIS OWN PARTICULAR USE.