Objectives
State the functional areas of the Horizon II macro
cabinet.
Describe the functions and operation of the
Horizon II macro Digital modules.
Describe the cabinet RF Components.
By the end of this chapter the student will be able to :-
-
7/29/2019 80829737 Motorola BTS Training
2/51
Basic Block Diagram of Cabinet
Three Main Functional areas:
1. Digital Cards
2. Radios (CTU2)
3. RF equipment
RF interface to Antenna
( Transmit - Combining and filtering)
(Receive Amplification and filtering)
CTU2 CTU2 CTU2 CTU2 CTU2 CTU2
E1 Link Digital Cage == Controls the cabinet
Alarms
Power Supplies
Antenna
-
7/29/2019 80829737 Motorola BTS Training
3/51
Support of 6x double density CTU2
Single or Double carrier per Radio.
Horizon II Site Controller (HIISC) Integrated NIU Integrated FMUX
E1 support Enhanced E1 Redundancy
Increased Capacity/removable flash media
Increased RSL functionality
Expansion of Horizon II macro cabinets to support 24 carriers per BTSsite.
Horizon II Expansion Multiplexer (XMUX)
Site Input/Output (I/O) Panel
Interoperability with current M-Cell and HORIZON macro products
The Horizon II macro BTS hardware supports the following functionality:
-
7/29/2019 80829737 Motorola BTS Training
4/51
Site
Controller
(HIISC)
CTU2Cooling
Fans
Power
Supply
Units
(PSU)
Circuit
Breaker
Card(CBC)
Alarm
Board
HORIZON II macro Cabinet Front View
-
7/29/2019 80829737 Motorola BTS Training
5/51
Site I/O
Panel
Tx Blocks
Link
Interface
Board
SURF2
Power
Supply
EAS Alarm,
PIX 0 & 1
HORIZON II macro Cabinet Top View
-
7/29/2019 80829737 Motorola BTS Training
6/51
Cabinet Power Supply
Maximum 4x PSU per cabinet One for
Redundancy
Depends on the number of Radios fitted.
The Cabinet can support the three types of power
supply
+27V (negative earth)
-48V (positive earth)
Nominal 120/240V AC
-
7/29/2019 80829737 Motorola BTS Training
7/51
Horizon II macro cabinet powersupply requirements
Nominal
Voltage
Voltage supply
range
Current supply
maximum
+27 V dc
(negative earth)
+19.5 to +30 V
dc
204A (at
nominal
voltage)
-48 v dc
(Positive earth)
-39 to 72 V dc 99A (at nominal
voltage)
120/240 V ac
(50 to 60 Hz)
88 to 270 V 45A (at nominalvoltage)
-
7/29/2019 80829737 Motorola BTS Training
8/51
-48v PowerSupply Units
-
7/29/2019 80829737 Motorola BTS Training
9/51
Power Supply Units
All three unit types support the same PSU
Alarms: O/P over/under voltage.
I/P under voltage.
Over temperature. Internal Fan failure.
-
7/29/2019 80829737 Motorola BTS Training
10/51
Circuit Breaker Card (CBC)
6x CCB forCTU2
2x Push Button HIISC
2x Push Button SURF2
1xTx RF Blocks
1x FAN trays
-
7/29/2019 80829737 Motorola BTS Training
11/51
StatusLEDs
States LEDs
GREEN (normaloperation) RED
(Fault).
CompactFlash Slot Compact FlashCard slot contains 32Mb
of memory.
TTY
MMI
TTY MMI
connection for 9
pin D type
connector.
Reset
Buttons
Reset Buttons
CPU is a Soft
Reset (ResetControllers
Main
Processors.
Software
remains in
RAM).
FULL is a
Hard reset.Removes
software from
memory.
CAL
Port
CAL PORT
Calibrates the
Sync Block. The
8K Reference is
used in GCLK
calibration.
NIU
Ethernet
Port
Synch/NIU
TTY PORT
The NIUEthernet and
SYNC/NIU TTY
Port are for
factory use only.
H11SC
Front Panel
-
7/29/2019 80829737 Motorola BTS Training
12/51
HIISC Functional Diagram
NIU Block
Line
Interface
Module
Line
Interface
Unit &
Framers
TSI
(SMURF)
NIU
Control
Processor
Radio(s)
Site
Control
Processor8 8
2
8
24?
2
Internal 2048 kbps
TDM interface with
32 timeslots.
Control Interface
External E1 or T1
interface.
NIU Port 0
& Port 1
Control via NIU
Port 0, TS 0
8
Frequency
Reference
Site Controller Card
Internal E1 or T1
interface.
-
7/29/2019 80829737 Motorola BTS Training
13/51
Horizon II macro HSCII Block diagram
E1 Inputs
x6
Curr
entx8 Future
Uplink RSL
Insertion
16Kbs only SMuRF
Sync, Mux, uBCU,
Replacement, FPGA
LAPD
Encode/Decode
Layer2 processing
Field Programmable Gate Array
(FPGA)
similarfunction as the ASIC
64Kb switch
incapable of sub-rate switching
BTP function of the BTS
runs site software and
call processing functions
CTU2
dual carrierunit
single/dual carrieroperation
single frequency ban
d
Three on board
XMUX functions
FMUX equivalent
SecondH2SC
configured for
redundancy
-
7/29/2019 80829737 Motorola BTS Training
14/51
Cabinet Expansion
The Cabinet can be expanded up to 3x
Horizon II macro Cabinets Can be expanded with Horizonmacro and
Mcell6 cabinet combinations.
Expansion Kit 1x XMUX card1x Input/Output (I/O) card
1x 2m Fibre Optic cable
-
7/29/2019 80829737 Motorola BTS Training
15/51
Cabinet Components Interconnections
Horizon II
Cabinet
H-II Radio
NBSCHIISC
Alarm
CTUII radio(s)
TDM
Site IO
H-II ExpansionCabinet
Site IO
XMUX
XMUX
Horizonmacro
Cabinet
FMUX
FMUX
Alarm
-
7/29/2019 80829737 Motorola BTS Training
16/51
Holdup Unit (AC Supply only)
-
7/29/2019 80829737 Motorola BTS Training
17/51
Cabinet Temperature Control
Operating range -5 C to +45 C
Three Internal FAN units speedcontrolled
3x Cabinet Temperature Sensors 1x (70 C) for cabinet alarm
2x (85 C) to shutdown the cabinet, reset at 55 C.
-
7/29/2019 80829737 Motorola BTS Training
18/51
Horizon II Site Controller (HIISC)
Performs functions of: MCUF, NIU, FMUX
and BPSM in Horizonmacro
cabinet.
Cabinet supports 2x HIISC cards
Master/Slave ( redundancy)
Compact Flash card (32 Mbyte memory)
-
7/29/2019 80829737 Motorola BTS Training
19/51
XMUX
in slot 0
XMUX
Location
-
7/29/2019 80829737 Motorola BTS Training
20/51
XMUX Functional Diagram
-
7/29/2019 80829737 Motorola BTS Training
21/51
Site Expansion Board
Connects up to 3x extra cabinets
Fibre optic connections
GPS connector (not supported)
Input/Output (I/O) card
-
7/29/2019 80829737 Motorola BTS Training
22/51
GPS
connection
Fibre
connections
IN/OUT
SITE I/O PANEL
CONFIGURATION
-
7/29/2019 80829737 Motorola BTS Training
23/51
Expansion configurations
Horizon II
macro (6xCTU2)
X
M
U
X
Horizon II
macro (6xCTU2)
E1
Two Horizon II macros expanded.
Horizon II
macro (6xCTU2)
X
M
U
X
Horizon II
macro (6xCTU2)
Horizonmacro
(6 x CTU)
F
M
U
X
E1
Horizon II macro, expanded to a Horizon II macro and a Horizonmacro.
-
7/29/2019 80829737 Motorola BTS Training
24/51
Expansion configuration (cont)
Horizon II
macro (6xCTU2)
X
M
U
X
Horizonmacro
(6 x CTU)
F
M
U
X
F
M
U
X
F
M
U
X
Horizonmacro
(6 x CTU)
E1
Horizonmacro controlling a Horizon II macro and another Horizonmacro.
M-Cell 6 controlling a Horizon II macro and a Horizonmacro.
Horizon II
macro (6xCTU2)
X
M
U
X
M-Cell 6
(6 x TCU)
F
M
U
X
F
M
U
X
F
M
U
X
Horizonmacro
(6 x CTU)
E1
-
7/29/2019 80829737 Motorola BTS Training
25/51
Cabinet Alarm Module
Collects All internal Cabinet Alarms
Controls the PIX connection (customerexternal alarms)
Process Antenna VSWR alarms
Note: NOT backwards compatible to the
Horizonmacro cabinet
-
7/29/2019 80829737 Motorola BTS Training
26/51
Alarm BoardMains
Door 1
LVD
Fan 0
Fan 1 & 2
ALL LEDs are
GREEN when the
equipment is OK
RED when
equipment isfaulty
Only 4x active Displays
-
7/29/2019 80829737 Motorola BTS Training
27/51
Compact Transceiver Unit
(CTU2)
CTU2
-
7/29/2019 80829737 Motorola BTS Training
28/51
Compact Transceiver Unit ( CTU2)
Single Density Mode High Power63W (48dbm) 900MHz
50W (47dbm) 1800MHz
Normal Power 20W (43dbm) 900MHz
16W (42dbm) 1800MHz
Double Density ModeNormal Power20W (43dbm) 900MHz
16W (42dbm) 1800MHZ
-
7/29/2019 80829737 Motorola BTS Training
29/51
CTU2 backwards compatibility
Compact Transceiver Unit 2 (CTU2)
Backwards compatible with Horizonmacro Cabinet
(with minor limitations).
Requires the correct software ( GSR6 HII)
Can NOT support the CCB controller function O/P power reduced when in Double Density
Mode
BBH not supported
-
7/29/2019 80829737 Motorola BTS Training
30/51
CTU2 Receiver Sensitivity Performance
EGSM900
-110.5 dBm, static channel -107.5 dBm, faded channel
DCS18
00 -111.5 dBm, static channel
-108.5 dBm, faded channel
-
7/29/2019 80829737 Motorola BTS Training
31/51
Compact TransceiverUnit 2 (CTU2)
TRANSMIT
RF OUT
TEST
INTERFACETTY
INTERFACE
Radio
Status
LED
TxStatus A
LED
Tx
Status B
LED
VCAT
INTERFACE
-
7/29/2019 80829737 Motorola BTS Training
32/51
CTU2 to SURF2 interconnection
Second SURF2 not supported
(4 branchdiversity)
-
7/29/2019 80829737 Motorola BTS Training
33/51
*
PA Branch 1
PA Branch 2
PA Temp.
2nd Temp.
Fwd Power Detect A
Fwd Power Detect B
Rev Power Detect
Phase Adjust
Branch B VVA
Branch A VVA
PA Mode Switches
PA Pad Switches
Basic Block Diagram TX (PA only)
-
7/29/2019 80829737 Motorola BTS Training
34/51
RF Equipment
RF Equipment
-
7/29/2019 80829737 Motorola BTS Training
35/51
Sectorized Universal ReceiverFront end (SURF2)
-
7/29/2019 80829737 Motorola BTS Training
36/51
SURF2 Functional diagram
3x Ant ports with 2x Branches each
Expansion
-
7/29/2019 80829737 Motorola BTS Training
37/51
CTU2
Signal
Tx Block
Rx Filter
Tx Filter
VSWR
Monitor
Alarm
Board
AntennaTo SURF
Tx
The Antenna VSWR monitoringfunction is used to detect faults inantennas or antenna path connections.
VSWR Monitoring
-
7/29/2019 80829737 Motorola BTS Training
38/51
Cabinet TX Blocks
Transmitter RF Blocks
New RF Blocks:
DUP - Duplexer HCU - Hybrid Combiner Unit
DHU - Dual Hybrid Combiner Unit
Connecting Panels Blanking Plate
Feedthrough plate
-
7/29/2019 80829737 Motorola BTS Training
39/51
TransmitterBlocks
-
7/29/2019 80829737 Motorola BTS Training
40/51
Blanking Plate
Used to control the Air flow within the cabinet
-
7/29/2019 80829737 Motorola BTS Training
41/51
Feedthrough Plate
-
7/29/2019 80829737 Motorola BTS Training
42/51
Duplexer- DUP
Connects a single CTU2 to
a single Tx/Rx Antenna.
Typical 1db loss.
-
7/29/2019 80829737 Motorola BTS Training
43/51
DUP Block diagram
-
7/29/2019 80829737 Motorola BTS Training
44/51
Hybrid Combiner Unit - HCU
HCU
Used to connect 2x
CTU2 via a Hybrid
Typical 3-4db loss
-
7/29/2019 80829737 Motorola BTS Training
45/51
HCU- Block diagram
Typical 3-4db loss
-
7/29/2019 80829737 Motorola BTS Training
46/51
Dual Hybrid Combiner Unit - DHU
Typical 6db loss
-
7/29/2019 80829737 Motorola BTS Training
47/51
Dual Hybrid Combiner Unit - DHU
6dbs typical
loss
-
7/29/2019 80829737 Motorola BTS Training
48/51
Software and Database Requirements
New Cabinet Type - horizonmacro2 (24)
- horizonmacro2_ext (25)
Equipping the DRI Density is requiredSingle or Double
(called the associated DRI)
Setting CTU2 to High Power(max_tx_bts= -1)
-
7/29/2019 80829737 Motorola BTS Training
49/51
MMI Command : equip DRI
Enter the 1st and 2nd DRI id: 0 0
Enter the density of this DRI: SINGLE
Enter the cabinet identifier: 0
Enter the type of connection to the BTP: masterEnter the port to which the TCU is connected: 0
Enter the 1st and 2nd RTF id:
Enter the GSM cell ID where the DRI appears: 1 2 3 9 9 4 21
Enter antenna select number for this cell: 1
Does this DRI use tuneable combining: noEnter diversity flag for this DRI: 1
Enter the fm cell type: 4
Equipping a DRI Single Density
New line within
the command
-
7/29/2019 80829737 Motorola BTS Training
50/51
MMI Command: equip DRI
Enter the 1st and 2nd DRI id: 0 0
Enter the density of this DRI: DOUBLE
Enter the 2nd DRI id of the associated DRI: 1
Enter the cabinet identifier: 0Enter the type of connection to the BTP: master
Enter the port to which the TCU is connected: 0
Enter the 1st and 2nd RTF id:
Enter the GSM cell ID where the DRI appears: 1 2 3 9 9 4 64
Enter antenna select number for this cell: 1Enter diversity flag for this DRI: 1
Enter the fm cell type: 4
Equipping a DRI Double Density
Associated DRI Number
-
7/29/2019 80829737 Motorola BTS Training
51/51
CTU2 High Power parameter
DRI equipped in SINGLE Density Mode only
Parameter max_tx_bts = -1 (per cell basis)
Parameter tx_power_cap =1 (DCS1800 only)
RF power EGSM900 DCS1800
63W (48dbm) 50W (47dbm)