80 975 - · pdf filev is ion s: no. sheet no: js h in t a ku 4 ... q0=8.7 cs q0=5.9 sc @2.0%...
TRANSCRIPT
80
+00
597
0
5970
5975
597
5
5990
5995
6005
0
GROUND
EXISTING
100-YR HGL
10-YR HGL
P-N-101 - 30" RCP (38 LF)
30" RCES30" RCES
HCL S FOURMILE
FOURMILE CANYON DR
90°16'28"
GRADE
FINISHEDCOVER1.0' MIN
CH-S-100
CH-S-103
TYPE 3
EMBANKMENT PROTECTOR
IN-S-EMB 112
=18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:12:4
9 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\South\Fourmile_
S_
Hydr_
PP01.dgn
R
4043.SEPT12C36
Q100=23.83 CFSQ10=11.45 CFS
@3.00%30" RCP
REQ'D 38 LF OF
P-S-101
597
5
5975
10 20 FT10
HORIZONTAL SCALE: 1"=20'
HW 10-YR=5972.26
HW 100-YR=5973.13
TW 100-YR=5970.05
TW 10-YR=5968.04
P-S-101
ELI
MR
UO
F
STA 79+72.94, 25.97' LT STA 79+72.69, 24.05' RT
STA 79+72.79
6000
5990
5980
5970
5960
5970
5980
5990
6000
5960
+
30% SET
JRS EAV
P-S-101DRAINAGE PLAN AND PROFILE
INV=5970.88
INV=5970.70
INV=5969.38
INV=5969.56
FOURMILE CANYON DR (SOUTH)
ELI
MR
UO
F
KE
ER
C
RD
N
OY
NA
C
JPZ 05/13/15 72
72
+00
5935
5955
0
INV=5938.80
INV=5938.65
10-YR HGL
100-YR HGL
FOURMILE CANYON DR
GROUND
EXISTING
INV=5339.95
INV=5339.80
30" RCES
P-N-105 - 30" RCP (40 LF)
HCL S FOURMILE
30" RCES90°00'00"
1.0' MIN COVER
GRADE
FINISHED
CH-S-104
CH-S-106
=18"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:13:0
9 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\South\Fourmile_
S_
Hydr_
PP02.d
gn
R
4043.SEPT12C36
Q100=28.87 CFSQ10=15.89 CFS
@2.50%30" RCP
REQ'D 40 LF OFP-S-105
10 20 FT10
HORIZONTAL SCALE: 1"=20'
P-S-105
ELI
MR
UO
F
5930
5940
5950
5960
59705970
5930
5940
5950
5960
59705970
30% SET
JRS EAV
P-S-105DRAINAGE PLAN AND PROFILE
STA 72+16.13, 26.36' LT
STA 72+16.13
STA 72+16.13, 25.74' RT
FOURMILE CANYON DR (SOUTH)
TW 100-YR=5938.54
TW 10-YR=5936.34
ELI
MR
UO
FK
EE
RC
RD
NO
YN
AC
HW 100-YR=5942.58
HW 10-YR=5941.71
JPZ 05/13/15 73
62
+00
5895
5895
5900
5900
5905
5910
5915
5920
5925
5935
5940
0
GRADE
FINISHED
FOURMILE CANYON DR
10-YR HGL
100-YR HGL
GROUND
EXISTING
HCL S FOURMILE
P-N-108 - 36" RCP (46 LF)
36" RCES
CH-S-109
36" RCES
70°39'30"
INV=5894.05
COVER1.0' MIN
CH-S-107
=18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
PROPOSED DRIVEWAY
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:13:2
7 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\South\Fourmile_
S_
Hydr_
PP03.d
gn
R
4043.SEPT12C36
Q100=24.68 CFSQ10=12.03 CFS
@1.67%
36" RCP REQ'D 46 LF OF
P-S-108
5900
5900
5905
5910
5915
5915
10 20 FT10
HORIZONTAL SCALE: 1"=20'
P-S-108
ELI
MR
UO
F
KE
ER
C
ELI
MR
UO
F
5920
5910
5900
5890 5890
5900
5910
5920
30% SET
JRS EAV
P-S-108DRAINAGE PLAN AND PROFILE
INV=5893.92INV=5894.94
INV=5894.81
STA 62+36.67
STA 62+46.33, 24.89' RT
STA 62+26.28, 33.39' LT
FOURMILE CANYON DR (SOUTH)
TW 100-YR=5898.89
TW 10-YR=5896.53 HW 10-YR=5896.64
HW 100-YR=5899.13
RD
NO
YN
AC
JPZ 05/13/15 74
587
0
587
0
5875
5880
5885
0
GRADE
FINISHED 10-YR HGL
100-YR HGL
FOURMILE CANYON DR
INV.=5864.76
INV.=5864.96
INV.=5866.38
INV.=5866.58
GROUND
EXISTING
HCL S FOURMILE
24" RCES
CH-S-110
24" RCES
P-S-111 - 24" RCP (43 LF)
94°00'06"
1.2' MIN COVER
=18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
Q100=25.22 CFSQ10=12.09 CFS
@3.27%24" RCP
REQ'D 43 LF OF
P-S-111
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:13:4
7 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\South\Fourmile_
S_
Hydr_
PP04.d
gn
R
4043.SEPT12C36
587
0
10 20 FT10
HORIZONTAL SCALE: 1"=20'
5890
5880
5870
5860
5890
5880
5870
5860
+
30% SET
JRS EAV
ELI
MR
UO
FR
D
NO
YN
AC
P-S-111
ELI
MR
UO
F
KE
ER
C
P-S-111DRAINAGE PLAN AND PROFILE
STA 52+50.21, 25.97' RTSTA 52+54.20, 29.34' LT
FOURMILE CANYON DR (SOUTH)
STA 52+51.84
TW 100-YR=5869.89
TW 10-YR=5866.95
HW 100-YR=5869.97
HW 10-YR=5868.18
JPZ 05/13/15 75
250
+00
6555
6560
6560
6565
6565
6570
6570
6570
6575
6575
6580
6580
6585
6590
0
10-YR HGL
100-YR HGL
FOURMILE CANYON DR
GRADE
FINISHED
GROUND
EXISTING
P-N-101 - 7' x 7' RCBC (37 LF)
WINGWALL D
WINGWALL C
HCL N FOURMILE
P-N-100
18" RCES
CH-N-102
90°14'48"
1.2' MIN COVER
=18"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
HEADWALL C-D
INV=6556.00
WALL N-4
WALL N-4
6560
6565
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:14:0
4 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\
North\Fourmile_
N_
Hydr_
PP05.d
gn
R
4043.SEPT12C36
Q100=499.40 CFSQ10=172.54 CFS
@1.61%
7' x 7' RCBC REQ'D 37 LF OF
P-N-101
10 10
HORIZONTAL SCALE: 1"=20'
20
P-N-101
+
6550
6560
6570
6550
6560
6570
6580 6580
65406540
30% SET
JRS EAV
FOURMILE CANYON DR(NORTH)
P-N-101DRAINAGE PLAN AND PROFILE
INV=6555.40
E
LI
MR
UO
FD
R
NO
YN
AC
KE
ER
C
ELI
MR
UO
F
STA 250+25.09, 21.00' LT
STA 250+25.19
STA 250+25.25, 16.25' RT
TW 10-YR=6557.89
HW 100-YR=6565.25
HW 10-YR=6560.48TW 100-YR=6560.00
05/13/15
NOTES:
SEE DRAINAGE PLANS FOR ADDTIONAL NOTES. 2.
FOR RETAINING WALL DETAILS, SEE RETAINING WALL PLANS.1.
JPZ 76
236+00
237+00
64
85
6490
64
90
6495
6495
6500
6500
6500
6505
6510
6515
6515
6520
6520
6525
6525
6530
6530
0
STA 236+36.86
48" RCES
P-N-200 - 48" RCP (115 LF)P-N-201 - 48" RCP (79 LF)
DRIVEWAY
PRIVATE
WINGWALL B
CH-N-110
WINGWALL A
HCL N FOURMILE
CH-N-112
GROUND
EXISTING
100-YR HGL
10-YR HGL
GRADE
FINISHED
FOURMILE CANYON DR
P-N-104 - 48" RCP (74 LF)
P-N-110 - 18" RCP (6 LF)
18" RCES
COVER1.5' MIN
=18"50
RIPRAP D=12"
50RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
HEADWALL A-B
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:14:2
2 P
M p
w:\\
DCP
WAPP1 .bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\
North\Fourmile_
N_
Hydr_
PP06.d
gn
R
4043.SEPT12C36
Q100=151.45 CFS
Q100=151.45 CFS
Q100=1
48.9
0 CFS
-
Q10=51.31 CFS
@3.00%48" RCP
REQ'D 115 LF OF
P-N-200
Q10=51.31 CFS
@4.18%48" R
CP REQ'D 7
9 LF OF
P-N-201
IN
V
OU
T=6500.0
0 (P-
N-201 - S)
IN
V IN
=6503.6
0 (P-
N-104 -
E)
IN
V IN
=6504.0
2 (P-
N-110 -
N)
H=16.9
7'
RI
M=65
03.1
3
MH
SL
AB
BA
SE,
HC
L
N
FO
UR
MIL
E
23
6+5
2.2
2,
23.7
7'
RT
MH-
N-2
00
H=10.0
0'
RI
M=65
10.0
0
MH
SL
AB
BA
SE,
HC
L
N
FO
UR
MIL
E
23
7+3
7.2
8,
31.1
0'
RT
MH-
N-2
01
Q10=4
9.70 C
FS
@19.4
0%48
" RCP
REQ'D
74 L
F OF
P-N-
104
IN
V
OU
T=64
86.1
6 (P-
N-200 - S
W)
IN
V IN
=64
96.7
1 (P-
N-201 -
N)
15 30 FT15
HORIZONTAL SCALE: 1"=30'
KE
ER
C
ELI
MR
UO
F
+
6505
6495
6485
6475
FO
UR
MIL
E
CA
NY
ON
DR
30% SET
JRS EAV
FOURMILE CANYON DR(NORTH)
DRAINAGE PLAN AND PROFILE
STA 235+77.08, 77.04' LT
TW 100-YR=6488.37
TW 10-YR=6485.87
HW 100-YR=6523.16
HW 10-YR=6521.09
INV=6482.71
STA 237+50.23, 23.11' RT
STA 236+52.22, 23.77' RT
MH-N-200 MANHOLE SLAB BASE (20 FOOT)
6515
6525
P-N-104
P-N-201, P-N-200 & P-N-104
INV=6482.47
INV=6518.00
6535
6505
6495
6485
6475
6515
6525
6535
STA 237+37.28, 31.10' RT
MH-N-201 MANHOLE SLAB BASE (10 FOOT)
STA 237+78.41, 96.97' RT
05/13/15JPZ 77
217
+00
6385
6390
6390
6395
6400
64
10
64
15
6435
64
45
0
42" RCES
P-N-108 - 42" RCP (42 LF)
42" RCES
CH-N-107
HCL N FOURMILE
GRADE
FINISHED
FOURMILE CANYON DR
10-YR HGL
100-YR HGL
INV=6406.34
INV=6406.76
INV=6408.96
INV=6409.38
GROUND
EXISTING
90°28'56.62"
1.0' MIN COVER
=12"50
RIPRAP D
=18"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
6405
6415
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:14:4
0 P
M p
w:\\
DCP
WAPP1.bkr.m
bakercorp.c
om:p
wprod\
Docu
ments\Proje
cts\
Lake
wood_
Office\
Boulder_
County_
Em
ergency_
Transportatio
n\
TO3\08_
Sheet_
Files\02_
Hydraulics\
DG
N\
North\Fourmile_
N_
Hydr_
PP07.d
gn
R
4043.SEPT12C36
Q100=79.82 CFSQ10=38.94 CFS
@5.20%42" RCP
REQ'D 42 LF OF
P-N-108
10 20 FT10
HORIZONTAL SCALE: 1"=20'
KE
ER
C
ELI
MR
UO
FP-N-108
6430
6420
6410
6400
6390
6380
6430
6420
6410
6400
6380
6390
+
30% SET
JRS EAV
FOURMILE CANYON DR(NORTH)
P-N-108DRAINAGE PLAN AND PROFILE
STA 217+26.04, 26.16' LT
STA 217+25.79
STA 217+25.56, 32.21' RT
HW 10-YR=6411.67
HW 100-YR=6413.38
ELI
MR
UO
F
RD
NO
YN
AC
TW 10-YR=6391.05
TW 10-YR=6390.00
05/13/15JPZ 78
EXISTING GROUNDPROPOSED GRADE
100-YR HGL
PROPOSED GRADE
EXISTING GROUND
100-YR HGL
10-YR HGL
10-YR HGL
100-YR HGL
PROPOSED GRADE
EXISTING GROUND
10-YR HGL
=18"50
RIPRAP D =18"50
RIPRAP D
=12"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
30% SET
JRS EMR
TW 10-YR = 5958.07
TW 100-YR = 5961.24
TW 100-YR = 5929.46
HW 100-YR = 5933.35
TW 10-YR = 5926.76
HW 10-YR = 5932.58
HW 10-YR = 5884.29TW 10-YR = 5884.01
HW 100-YR = 5886.13TW 100-YR = 5886.12HW 100-YR = 5961.26
HW 10-YR = 5959.49
INV
=5958.2
8
18"
RC
P
HC
L S F
OU
RMIL
E
76+08.8
6, 25.3
9' R
T
FE
S-S-1
03-U
INV
=5957.5
6
18"
RC
P
HC
L S F
OU
RMIL
E
76+08.8
6, 25.9
5' LT
FE
S-S-1
03-D
INV
=5930.1
8
24"
RC
P
HC
L S F
OU
RMIL
E
68+48.7
3, 27.0
1' LT
FE
S-S-1
06-D
INV
=5931.5
4
24"
RC
P
HC
L S F
OU
RMIL
E
68+54.8
4, 23.8
1' R
T
FE
S-S-1
06-U
INV
=5881.8
3
18"
RC
P
HC
L S F
OU
RMIL
E
58+21.9
6, 32.5
3' LT
FE
S-S-1
09-D
INV
=5882.5
8
18"
RC
P
HC
L S F
OU
RMIL
E
58+21.9
6, 46.0
7' R
T
FE
S-S-1
09-U
1.1'
MIN C
OV
ER
1.1'
MIN C
OV
ER
1.3'
MIN C
OV
ER
FOURMILE CANYON DR (SOUTH)
DRAINAGE PROFILES
05/13/15JPZ
5920
5925
5930
5935
5940
5920
5925
5930
5935
5940
Q100=13.92
CFS
5950
5955
5960
5965
59705970
5950
5955
5960
5965
5970
Q100=11.23 CFS
5875
5880
5885
5890
5895
5875
5880
5885
5890
5895
Q100=9.91 CFS
P-S-103 P-S-109P-S-1065920
5925
5930
5935
5940
5920
5925
5930
5935
5940
Q10=6.11 [email protected]
%24"
RCP REQ'D 39
LF OFP-S
-106
5950
5955
5960
5965
59705970
5950
5955
5960
5965
59705970
Q10=5.37 CFS
@1.40%18" RCP
REQ'D 39 LF OF
P-S-103
5875
5880
5885
5890
5895
5875
5880
5885
5890
5895
P-S-109
REQ'D 63 LF OF
18" RCP
@1.00%
Q10=4.92 CFS
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:1
4: 5
8 P
M p
w:\\
DC
PW
AP
P1.b
kr. m
bakercorp.c
om:p
wprod\
Docu
ments\
Projects\
Lake
wood_
Offic
e\
Bould
er_
County_
Em
ergency_
Transportatio
n\
TO
3\
08_
Sheet_
Files\
02_
Hydraulics\
DG
N\
South\
Four
mile_
S_
Hydr_
Profiles01.d
gn
R
4043.SEPT12C36 79
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE
EXISTING GROUND
EXISTING GROUND
100-YEAR HGL
10-YEAR HGL
10-YEAR HGL
100-YEAR HGL
10-YR HGL
100-YR HGL
100-YEAR HGL
10-YEAR HGL100-YEAR HGL
10-YEAR HGL
1.7'
MIN C
OV
ER
1.2'
MIN C
OV
ER
1.0'
MIN C
OV
ER
1.0'
MIN C
OV
ER
1.1'
MIN C
OV
ER
=12"50
RIPRAP D
=18"50
RIPRAP D=18"
50RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
=18"50
RIPRAP D
=12"50
RIPRAP D
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:1
5:2
4 P
M p
w:\\
DC
PW
AP
P1.b
kr. m
bakercorp.c
om:p
wprod\
Docu
ments\
Projects\
Lake
wood_
Offic
e\
Bould
er_
County_
Em
ergency_
Transportatio
n\
TO
3\
08_
Sheet_
Files\
02_
Hydraulics\
DG
N\
North\
Four
mile_
N_
Hydr_
Profiles02.d
gn
R
4043.SEPT12C36
Q100=5.31 CFS
Q100=
28.16 C
FS
Q100=17.08 CFS
Q100=21.2
5 CFS
Q100=8.69 CFS
P-N-100 P-N-102
P-N-103 P-N-106P-N-105
6560
6565
6570
6560
6565
6570
65756575
6540
6545
6550
6555
6540
6545
6550
6555
P-N-102
REQ'D 34 LF OF
18" RCP
@0.50%
Q10=2.46 CFS
6505
6510
6515
6520
6525
6505
6510
6515
6520
6525
6465
6470
6475
6480
6485
6465
6470
6475
6480
6485
Q10=8.41 CFS
@1.00%24" RCP
REQ'D 44 LF OF
P-N-105
6435
6440
6445
6450
6455
6435
6440
6445
6450
6455
Q10=9.93 C
24" RCP REQ'D
44 LF OFP-N-
106
Q10=1
4.15 C
FS
@4.7
0%30" R
CP
REQ'D 57 LF O
F
P-N-
109
Q10=3.94 CFS
@3.65%
18" RCP
REQ'D 23 LF OF
P-N-100
30% SET
JRS EMR
TW 100-YR=6565.25
HW 100-YR=6566.59
HW 100-YR=6549.29
TW 100-YR=6547.00
HW 100-YR=6517.82
TW 100-YR=6513.18
HW 100-YR=6479.29
TW 100-YR = 6471.26
HW 100-YR = 6448.74
TW 100-YR = 6445.96
HW 10-YR=6565.89
TW 10-YR=6565.00
HW 10-YR=6516.87
HW 10-YR=6548.82
TW 10-YR=6544.98
TW 10-YR = 6445.74
HW 10-YR = 6447.62
HW 10-YR=6478.47
TW 10-YR=6513.01
TW 10-YR = 6469.68
INV
=6565.0
5
18"
RC
P
HC
L N F
OU
RMIL
E
250+64.8
0, 24.6
2' R
T
FE
S-N-1
00
U INV
=6547.7
6
18"
RC
P
HC
L N F
OU
RMIL
E
247+45.8
6, 24.2
4' LT
FE
S-N-1
02
D
INV
=6547.9
9
18"
RC
P
HC
L N F
OU
RMIL
E
247+45.8
6, 22.1
0' R
T
FE
S-N-1
02
U
INV
=6512.1
7
30"
RC
P
HC
L N F
OU
RMIL
E
240+50.3
0, 40.4
4' LT
FE
S-N-1
03
D
INV
=6515.4
0
30"
RC
P
HC
L N F
OU
RMIL
E
240+26.2
8, 24.7
4' R
T
FE
S-N-1
03
U
INV
=6476.5
0
24"
RC
P
HC
L N F
OU
RMIL
E
232+46.8
8, 31.5
2' LT
FE
S-N-1
05
D
INV
=6477.0
6
24"
RC
P
HC
L N F
OU
RMIL
E
232+47.2
6, 24.8
8' R
T
FE
S-N-1
05
U
INV
=6445.9
5
24"
RC
P
HC
L N F
OU
RMIL
E
225+49.1
0, 29.6
8' LT
FE
S-N-1
06
D INV
=6446.1
4
24"
RC
P
HC
L N F
OU
RMIL
E
225+52.7
7, 26.2
5' R
T
FE
S-N-1
05
U
DRAINAGE PROFILESFOURMILE CANYON DR(NORTH)
JPZ 05/13/15 80
EXISTING GROUND
PROPOSED GRADE
EXISTING GROUND PROPOSED GRADE
10-YEAR HGL
100-YEAR HGL
100-YR HGL
10-YR HGL
1.2'
MIN C
OV
ER
1.0'
MIN C
OV
ER
10-YEAR HGL
100-YEAR HGL
EXISTING GROUND
PROPOSED GRADE
=18"50
RIPRAP D
=12"50
RIPRAP D =18"50
RIPRAP D
=12"50
RIPRAP D
ENGINEERING DIVISION
BOULDER COUNTY TRANSPORTATION DEPARTMENT
DESIGNED:
PROJECT NO:
DATE:CAD: CHECKED:
REVISION DESCRIPTION:DATE
UTILITIES
OF UNDERGROUND MEMBER
OR EXCAVATE FOR THE MARKING
ADVANCE BEFORE YOU DIG, GRADE,
CALL 2-BUSINESS DAYS IN
CALL UTILITY NOTIFICATION CENTER OF COLORADO
RE
VISIO
NS: NO.
SHEET NO:
jshintaku 4:1
5:4
2 P
M p
w:\\
DC
PW
AP
P1.b
kr. m
bakercorp.c
om:p
wprod\
Docu
ments\
Projects\
Lake
wood_
Offic
e\
Bould
er_
County_
Em
ergency_
Transportatio
n\
TO
3\
08_
Sheet_
Files\
02_
Hydraulics\
DG
N\
North\
Four
mile_
N_
Hydr_
Profiles03.d
gn
R
4043.SEPT12C36
6525
6530
6535
6540
6525
6530
6535
6540
Q10=1.86 [email protected]
0%18" R
CP REQ'D
30 LF OF
P-N-10
9
P-N-109
P-N-112
6480
6485
6490
6495
6500
6480
6485
6490
6495
6500
Q10=2.48 CFS
@1.43%18" RCP
REQ'D 43 LF OF
P-N-112
INV O
UT=6492.7
5 (P-N-1
12 - W
)
6500
6505
6510
6515
6500
6505
6510
6515
INV OUT=6500.00 (P-N-201 - S)
INV IN=6503.60 (P-N-104 - E)
INV IN=6504.02 (P-N-110 - N)
H=10.0
0'
RIM
=6510.0
0
MH S
LA
B B
AS
E,
HC
L N F
OU
RMIL
E
237+37.2
8, 31.1
0' R
T
MH-N-2
01
H=3.2
2'
GR
AT
E=6495.9
7
TY
PE C,
HC
L N F
OU
RMIL
E
235+64.1
7, 19.9
9' R
T
IN-N-1
12
Q10=1.62 CFS
@1.00%
18" RCP
REQ'D 6 LF OF
P-N-110
30% SET
JRS EMR
TW 100-YR=6484.30
HW 100-YR=6496.32
HW 100-YR = 6529.02
TW 100-YR = 6527.46
TW 10-YR=6482.72
TW 10-YR = 6527.30
HW 10-YR = 6528.65
HW 10-YR=6496.22
DRAINAGE PROFILESFOURMILE CANYON DR(NORTH)
P-N-110
INV
=6504.1
4
18"
RC
P
HC
L N F
OU
RMIL
E
237+50.2
3, 23.1
1' R
T
FE
S-N-1
10
INV
=6526.5
4
18"
RC
P
HC
L N F
OU
RMIL
E
242+37.9
1, 25.1
2' R
T
FE
S-N-1
09
D INV
=6528.2
2
18"
RC
P
HC
L N F
OU
RMIL
E
242+76.8
3, 25.1
0' R
T
FE
S-N-1
09
U
INV
=6492.0
5
18"
RC
P
HC
L N F
OU
RMIL
E
235+38.4
3, 23.0
8' LT
FE
S-N-1
12
D
HW 100-YR=6504.91
HW 10-YR=6504.72
05/13/15JPZ 81