3 - the simatic manager
TRANSCRIPT
-
8/20/2019 3 - The Simatic Manager
1/25
Date: 1/16/2012File: PRO1_03E.1
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
The SIMATIC Manager
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
2/25
Date: 1/16/2012File: PRO1_03E.2
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Objectives
Upon completion of the chapter the participant will ...
... understand the project structure in the SIMATIC Manager
… understand the function "accessible nodes"
... be familiar with the offline / online view in the SIMATIC Manager
... be familiar with the STEP7 Standard Libraries
... be familiar with the STEP7 help system
... be able to create and manage a project with the SIMATIC Manager
… be able to set the PG´s interface
… be able to erase an MMC
… be able to perform an S7 CPU memory reset
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
3/25
Date: 1/16/2012File: PRO1_03E.3
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
From Process to Project
FB21
Hardware
Software
Project Management
Prozess
OB1
SIMATIC Manager
I 1.0 I 1.1 Q4.0
Communication
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
4/25
Date: 1/16/2012File: PRO1_03E.4
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Opening a Project, Deleting a Project, and Project Save As
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
5/25
Date: 1/16/2012File: PRO1_03E.5
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
STEP 7 Project Structure
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
6/25
Date: 1/16/2012File: PRO1_03E.6
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
S7 Program Blocks
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
7/25
Date: 1/16/2012File: PRO1_03E.7
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Cyclic Program Processing
OB1
Network 1
A(O I 0.0
O Q 4.1)A I 0.1= Q 4.1
Network 2
Call FC 1NOP 0
Network 3
User Program Execution
Scan Cycle TimerStart/Reset
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
8/25
Date: 1/16/2012File: PRO1_03E.8
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Interesting Facts about Multiprojects
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
9/25
Date: 1/16/2012File: PRO1_03E.9
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Creating an S7 Project
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
10/25
Date: 1/16/2012File: PRO1_03E.10
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Inserting an S7 Program
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
11/25
Date: 1/16/2012File: PRO1_03E.11
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Standard Library
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
12/25
Date: 1/16/2012File: PRO1_03E.12
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
STEP 7 Help System
Press Hot-key F1
Example
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
13/25
Date: 1/16/2012File: PRO1_03E.13
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Context Sensitive Help in STEP 7
Press Hot-key F1
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
14/25
Date: 1/16/2012File: PRO1_03E.14
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Setting the PG/PC Interface
STEP 7
CP5611
CPU
Access Pointof the Application:
S7ONLINE
Interface ParameterAssignment Used:
CP5611 (MPI)
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
15/25
Date: 1/16/2012File: PRO1_03E.15
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Offline / Online View in the SIMATIC Manager
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
16/25
Date: 1/16/2012File: PRO1_03E.16
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Online Connection using "Accessible Nodes"
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
17/25
Date: 1/16/2012File: PRO1_03E.17
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Erasing Data Stored on the MMC
Icon
Icon
Menu option “PLC displayaccessible nodes“
Menu option“View online“
or
or
Project – Online – View:
Accessible Nodes:
any user file
S7 project archive
www.infoPLC.net
i f PLC t
-
8/20/2019 3 - The Simatic Manager
18/25
Date: 1/16/2012File: PRO1_03E.18
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Exercise 1: Setting the PG Interface to MPI
www.infoPLC.net
www infoPLC net
-
8/20/2019 3 - The Simatic Manager
19/25
Date: 1/16/2012File: PRO1_03E.19
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Exercise 2: Performing a CPU Memory Reset and a Warm Restart
RUN-P
RUN
STOP
MRES
1. Set the mode selector switch to STOP
within 1 sec
RUN
STOP
MRES
RUN-P
RUN
STOP
MRES
2. Hold (Press) the mode selector switch in the MRES
position until the STOP LED has flashed twice slowly.
Release the mode selector switch so that it returns to
the STOP position.
RUN
STOP
MRES
RUN-P
RUN
STOP
MRES
3. Turn (press) the mode selector switch to the MRES posi--tion once more until the STOP LED begins to flash quickly.Release the mode selector switch so that it returns tothe STOP position.
RUN
STOP
MRES
RUN-P
RUN
STOP
MRES
4. Set the mode selector switch to the RUN-P (RUN)position. (A warm restart is carried out in the transitionfrom STOP to RUN/RUN-P)
RUN
STOP
MRES
Until Oct. 2002 After Oct. 2002
www.infoPLC.net
www infoPLC net
-
8/20/2019 3 - The Simatic Manager
20/25
Date: 1/16/2012File: PRO1_03E.20
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Calling the "Monitor/Modify Variables" Tool
www.infoPLC.net
www infoPLC net
-
8/20/2019 3 - The Simatic Manager
21/25
Date: 1/16/2012File: PRO1_03E.21
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Establishing Trigger Points for "Monitor/Modify Variable"
Trigger point
"Beginning of Scan Cycle"
Cyclic
program
execution
PII
PIQ
SetTrigger
Trigger point
"End of Scan Cycle"
Trigger point
"Transition to STOP"
Monitor / Modifydepending onTrigger setting
Update Status / ModifyValues (one timemonitor / modify)
www.infoPLC.net
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
22/25
Date: 1/16/2012File: PRO1_03E.22
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Opening a Variable Table and Establishing a Connection to the CPU
ConfiguredCPU
(VAT fromHW Station
"Station 2")
Station 2Directlyconnected
CPU
Station 1
PG
Station 3
Accessible CPUs
www.infoPLC.net
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
23/25
Date: 1/16/2012File: PRO1_03E.23
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
Exercise 3: Creating a Project
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
24/25
Date: 1/16/2012File: PRO1_03E.24
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
If You Want to Know More
www.infoPLC.net
-
8/20/2019 3 - The Simatic Manager
25/25
Date: 1/16/2012File: PRO1_03E.25
SIMATIC S7Siemens AG 2006. All rights reserved.
SITRAIN Training for Automation and Industrial Solutions
SIMATIC Manager Customizing Options