2u atca shelf october 2007 -proprietary and confidential-
TRANSCRIPT
![Page 1: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/1.jpg)
2U ATCA Shelf October 2007
-Proprietary and Confidential-
![Page 2: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/2.jpg)
-Proprietary and Confidential-
2
General description
2U ATCA Shelf 2 slot Mounting systems
19'' Cabinet 23'' Cabinet
ETSI Cabinet (600 mm width) Operating temperature from (-5°C) – (+55°C)
Altitude - 1800 meter above sea level (NEBS requirement)
![Page 3: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/3.jpg)
-Proprietary and Confidential-
3
2U ATCA Shelf
Front ViewFront View
![Page 4: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/4.jpg)
-Proprietary and Confidential-
4
2U ATCA Shelf
Rear ViewRear View
![Page 5: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/5.jpg)
-Proprietary and Confidential-
5
MechanicalMechanical
Chassis Material Material: Steel 1010-1016, zinc plated, Painted. 90% of the parts are assembled by riveting – reduce assembly costs & complexity
![Page 6: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/6.jpg)
-Proprietary and Confidential-
6
General descriptionGeneral descriptionFront view
Rear viewShelf ID
EEPROM x2 Shelf manager
x2
![Page 7: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/7.jpg)
-Proprietary and Confidential-
7
MechanicalMechanical
Height: 89 mm (2U)
450 mm
38
2
mm
![Page 8: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/8.jpg)
-Proprietary and Confidential-
8
MechanicalMechanical
PEMs
Front View
Rear View
Top View
Fan trays
Air Filter
Shelf managers
![Page 9: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/9.jpg)
-Proprietary and Confidential-
9
Components:Chassis Air filter2 Shelf managers2 PEMCable managementFan trayBackplane
MechanicalMechanicalMechanicalMechanical
![Page 10: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/10.jpg)
-Proprietary and Confidential-
10
Air FilterAir Filter
Meet NEBS requirements
Filters all the air which is flowing into the shelf, both front and RTM areas.
Easy maintenance
Captive screw, locking filter to chassis
Easy to open and replace the air filter
material
![Page 11: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/11.jpg)
-Proprietary and Confidential-
11
Air filter presence is detected using a switch
on the fan card
Air FilterAir Filter
![Page 12: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/12.jpg)
-Proprietary and Confidential-
12
Shelf ManagerShelf Manager
Front LEDs
Ethernet Serial Alarm
Reset switch Alarm Clear
![Page 13: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/13.jpg)
-Proprietary and Confidential-
13
Shelf ManagerShelf Manager
![Page 14: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/14.jpg)
-Proprietary and Confidential-
14
Main functionality: Compliant with PICMG 3.0 Fan tray control Temperature monitoring Discrete alarm outputs LED Alarms display Pigeon point ShMM500 module Front and rear Ethernet connection. Application blades control and power-up Hot swappable and redundant Remote access via Web interface, SNMP, RMCP and
CLI
The Shelf manager Board The Shelf manager Board
![Page 15: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/15.jpg)
-Proprietary and Confidential-
15
PEMPEM
Protective cover
EjectorTerminal Block
![Page 16: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/16.jpg)
-Proprietary and Confidential-
16
Main features: Field replaceable unit Alignment pin for smooth insertion and
extraction Common mode choke to meet EMC
requirements Insertion/extraction lever for easy
replacement Protective cover to prevent electrocution
and accidental power short.
PEMPEM
![Page 17: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/17.jpg)
-Proprietary and Confidential-
17
Cable management - optional Left Right
Cable managementCable management
![Page 18: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/18.jpg)
-Proprietary and Confidential-
18
Front insertion Comfortable and rigid extraction handle Push concept for superior cooling
Fan TrayFan Tray
Locking screw
80x80x25 fan (x4)
Front View
![Page 19: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/19.jpg)
-Proprietary and Confidential-
19
BackplaneBackplane
FRONT VIEW
Zone 1Zone 2
Right Shelf managerLeft Shelf manager
![Page 20: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/20.jpg)
-Proprietary and Confidential-
20
BackplaneBackplane
Rear VIEW
Right PEMLeft PEM
E²prom and fan tray
connection
![Page 21: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/21.jpg)
-Proprietary and Confidential-
21
Main features:Main features: Two AdvancedTCA slots Fabric interface with full mesh interconnect Dual-star Ethernet signalling environment on the
Base interface Bussed IPMI Two Hub/Node slots Update channel between slots 1&2 Full compliance with AdvancedTCA™ electrical
and mechanical specifications
BackplaneBackplane
![Page 22: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/22.jpg)
-Proprietary and Confidential-
22
E²prom’sE²prom’s
E²prom Cards
Zoom view
disintegrable E²prom cards
Redundant and hot-swappable.Easy access and removal.
Rear view
Pluggable E²prom cards
![Page 23: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/23.jpg)
-Proprietary and Confidential-
23
RFI RFI
EMC sealed chassis
The RED lines represent EMC sealed areas. Sealing is being achieved by the use of EMI gaskets, springs and proper EMC design practices.
![Page 24: 2U ATCA Shelf October 2007 -Proprietary and Confidential-](https://reader033.vdocuments.us/reader033/viewer/2022051401/56649f495503460f94c6b6bc/html5/thumbnails/24.jpg)
Thank you