212680000 e 05
TRANSCRIPT
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 1/42
Alcatel-Lucent GSM
BSS Methods Handbook
BSS Document
Procedural Handbook
Release B10
3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 2/42
Status RELEASED
Short title BSS Methods Handbook
All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.
BLANK PAGE BREAK
2 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 3/42
Contents
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 Basic Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 From BSC Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1.1 Load BSS Software from BSC Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1.2 Offline Hardware Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.1.3 BSC Reloading Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.1.4 9130 BSC Evolution DLS Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.1.5 9130 BSC Evolution Backup/Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 From Transmission Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.2.1 Check Alarms on ATBX Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.2.2 Check Alarms on ASMC Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.2.3 Local Download of Generic Settings for G2TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.3 From TC-NEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.3.1 E1 to STM1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.3.2 STM1 to E1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
1.4 From BTS Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.4.1 Call Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.4.2 Locally Load Software on 9100/9110 Micro BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.5 Program Initial Transmission Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241.5.1 G1 BTS (MKII), G2 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241.5.2 9100 BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.6 Common Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261.6.1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261.6.2 Hardware Technical Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261.6.3 Connect BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261.6.4 Disconnect BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.6.5 Connect Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.6.6 Disconnect Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281.6.7 Change Abis Port from One Port to Another . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.1 Faults and Anomalies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.1.1 ALCATEL 3000 Failure Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.1.2 Fault Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.2 Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.2.1 General Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.2.2 Safety Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.2.3 Safety Requirements IEC 950 (Excerpt) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.2.4 Safety Rules for Equipment Under Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.2.5 Equipment Emitting RF Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.2.6 Electrostatic Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332.3 Fill In a CCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3BK 21268 AAAA PCZZA Ed.05 3 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 4/42
Contents
4 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 5/42
Preface
Preface
Purpose This Methods Handbook presents a list of tasks for the control and maintenanceof the Alcatel BSS for the mobile communication network.
This document applies to operational BSS from release B10.
What’s New In Edition 05
Update with the new equipment naming.
In Edition 04
Update in section Fill In a CCL (Section 2.3)
In Edition 03
Delivered in release.
First official release of the document for B10 MR2.
In Edition 02
Update in section Fill In a CCL (Section 2.3)
In Edition 01
First official release of the document for B10.
Audience This document is intended for:
Commissioning personnel
System support engineers (specialists)
Field service technicians.
Assumed Knowledge You must have a basic understanding of the following:
Alcatel-Lucent Operations and Maintenance concepts for the BSS
BSC, TC, BTS hardware configurations
Installation and commissioning tools
3BK 21268 AAAA PCZZA Ed.05 5 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 6/42
Preface
Windows environment.
6 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 7/42
1 Basic Tasks
1 Basic Tasks
This section describes the basic tasks to be performed on BTS, BSC, and TCsites before, during and after commissioning.
3BK 21268 AAAA PCZZA Ed.05 7 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 8/42
1 Basic Tasks
1.1 From BSC Terminal
Note: Perform the following tasks with a BSC Terminal running on Windows 2000/XP.
1.1.1 Load BSS Software from BSC Terminal
Three cases apply:
C1 : Load the BSS Software with the files stored on the diskettes (quantity =
7) that were created during the complete backup from the OMC-R (DISK_A
+ DISK_B + DISK_C)
C2 : Load the BSS Software with the SDP Package and the first diskette
that was created during the partial backup from the OMC-R (DISK_A)
C3 : Load the BSS Software with the files stored using ftp during the
backup performed from the OMC-R.
To load the BSS Software from the BSC Terminal:1. Create a directory for either the B10 gzip files (C1or C3) or the SDP Package
files and the B10 gzip files from the first diskette (C2):
Create a target directory (example: C:\target_name)
Copy gzip.exe from C:\ProgramFiles\Alcatel\WinBSC\B10 to the
target directory
For C1: Copy all compressed files (gzip) from backup diskettes to
the target directory
For C2: Copy the SDP Package files and the files from the first backup
diskette in the target directory
For C3: Copy all compressed files (gzip) into the target directory (copy
the content of all the folders that were transferred using ftp)
Open a "Command Prompt" window on the BSC terminal
Select the target directory: cd C:\target_name
Uncompress the gzip files: gzip -dvN *.gz.
2. Disable the BSC.
From the BSC terminal menu bar, select:
Commands -> Equipment Handling-> SBL DisableObject Class: ’SBL’
Unit Type: ’BSC’, Unit Number: ’1’
SBL Type: ’BSC’, Nbr: ’1’, SubNbr: ’255’
WTC (Wait Traffic Clear): ’0’
Click on [ OK ].
8 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 9/42
1 Basic Tasks
3. Format disk A (CPRA system A, subrack 8, slot 27).
From the BSC terminal menu bar, select:
Commands -> Disk operations -> Format SSD
Directory path: C:\target_name
Available file: Select the BSS masterfile name
<cipher>MZQ xx.xxx for B6
<cipher>MZT xx.xxx for B7
<cipher>MZV xx.xxx for B8
<cipher>MZW xx.xxx for B9
<cipher> MZX xx.xxx for B10.
Destination disk: ’Disk A:’
Click on [ Go! ].
4. Load the BSS software on disk A.
From the BSC terminal menu bar, select:
Commands -> Disk operations -> File transfer from PC to BSC.
Directory path: C:\target_nameAvailable file: Select the BSS masterfilename
<cipher>MZQ xx.xxx for B6
<cipher>MZT xx.xxx for B7
<cipher>MZV xx.xxx for B8
<cipher>MZW xx.xxx for B9
<cipher> MZX xx.xxx for B10.
Destination disk: ’Disk A:’
Click on [ Go! ].
5. Format disk B (CPRA system B, subrack 8, slot 31)
From the BSC terminal menu bar, select:
Commands -> Disk operations -> Format Duplex SSD.
Source-destination-disk: from DISKA: to DISKB:
Click on [ OK ].
6. Copy the BSS software to Disk B (CPRA system B, subrack 8, slot 31).
From the BSC terminal menu bar, select:
Commands -> Disk operations -> File Transfer from BSC to BSC.
Source disk: ’Disk A:’
Destination disk: ’Disk B:’
Select ’All Files’
Click on [ OK ].
7. Wait until all the files are transferred from disk A to disk B.
When the file transfer in finished, the following message appears:
File copy completed.
3BK 21268 AAAA PCZZA Ed.05 9 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 10/42
1 Basic Tasks
8. Activate loading of the BSC.
From the BSC terminal menu bar, select:
Commands -> System Activation -> System Initialization.
Unit Identity: ’BSC’
Unit Number: ’01’
Init Level: ’REBOOT’
Click on [ OK ].
9. Wait for the BSC to complete its startup.
10. Check that the contents of both disks are identical.
From the BSC terminal menu bar, select:
Commands -> Disk operations -> Control SSD
Action: ’DISK INFORMATION’
Involved SSD: ’Disk A’
Click on [ OK ].
From the BSC terminal menu bar, select:
Commands -> Disk operations -> Control SSD
Action: ’DISK INFORMATION’
Involved SSD: ’Disk B’
Click on [ OK ].
Compare the two results. There must be the same number of files.
1.1.2 Offline Hardware Test
Before the BSC can be tested, it must be in the idle state, with the software inall the Control Elements (CE) running in the idle mode.
1.1.2.1 Test ProcedureTo start the test procedure:
1. Reboot BSC in OFFLINE TEST Mode
2. Trigger BSC Hardware Test
3. Reboot BSC in OPERATIONAL Mode .
1.1.2.2 Reboot BSC in OFFLINE TEST Mode
To reboot the BSC in OFFLINE TEST mode:
1. Select:
Commands -> Commissioning Tests -> BSC System Test Init
2. In ’Unit identity’, select the ’BSC’ parameter.
3. In ’Unit Number’, enter the ’1’ parameter.
4. In ’Initialization level’, select the ’REBOOT’ parameter.
5. In ’Test Mode’, select the ’OFFLINE TEST’ parameter.
6. In ’Autoconfiguration’, select the ’NO AUTOCONFIGURATION’ parameter.
7. Click on [ OK ].
8. Wait approximately 10 minutes for the successful report. Check that 94CE (configuration 3) are equipped.
10 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 11/42
1 Basic Tasks
1.1.2.3 Trigger BSC Hardware Test
To perform a network test:
1. Select Commands -> Commissioning Tests ->Test Facilities for G2-> Network Test.
2. In ’Test’, select the ’GLOBAL NETWORK’ parameter.
3. In ’Source’, select the ’******’ parameter.
4. In ’Tunnel’, select the ’******’ parameter.
5. In ’Destination’, select the ’******’ parameter.
6. In ’Port’, select the ’******’ parameter.
7. In ’Loop’, select the ’NO’ parameter.
8. Click on [ OK ].
9. Wait for the successful report.
To perform a broadcast test:
1. Select Commands -> Commissioning Tests ->Test Facilities for G2 ->Broadcast Test.
2. In ’Test’, select the ’BROADCAST TEST’ parameter.
3. In ’All CE’s’, select the ’YES’ parameter.
4. In ’Loop’, select the ’NO’ parameter.
5. Click on [ OK ].
6. Wait for the successful report.
To perform a clock test:
1. Select Commands -> Commissioning Tests ->Test Facilities for G2
-> Clock Test.
2. In ’Test’, select the ’GLOBAL CLOCK TEST’ parameter.
3. In ’Transmission’, select the ’NO’ parameter.
4. In ’External Ref’, select the ’NO’ parameter.
5. In ’Loop’, select the ’NO’ parameter.
6. Click on [ OK ].
7. Wait for the successful report.
Note: If any hardware test fails, try to identify the problem and fix it. Repeat all thehardware tests. If a test still fails, check the inter-rack cabling between the racks.
3BK 21268 AAAA PCZZA Ed.05 11 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 12/42
1 Basic Tasks
1.1.2.4 Reboot BSC in OPERATIONAL Mode
To reboot the BSC in OPERATIONAL mode:
1. Select:
Commands -> Commissioning Tests -> BSC System Test Init.
2. In ’Unit identity’, select the ’BSC’ parameter.3. In ’Unit Number’, select the ’1’ parameter.
4. In ’Initialization level’, select the ’REBOOT’ parameter.
5. In ’Test Mode’, select the ’OPERATIONAL’ parameter.
6. In ’Autoconfiguration’, select the ’NO AUTOCONFIGURATION’ parameter.
7. Click on [ OK ].
8. Wait approximately 10 minutes for the successful report.
1.1.3 BSC Reloading Test
1.1.3.1 Disconnect/Reconnect Main Power Supply
To disconnect/reconnect the main power supply:
1. Switch OFF all the rack circuit breakers. No LED is lit.
2. Switch ON all the rack circuit breakers. All the boards run the self testand reload.
The TCU 1, DTC 1, and CPRCs 3, 4, 5, and 6 boards are loaded by
CPRC boards 1 and 2
The loaded TCU and DTC boards then load the remaining TCU and
DTC boards (cascade loading). When loading is complete, all boards
are ready to start.
The loading procedure is indicated by the LEDs on the board front
panels. Refer to Hardware Information, which describes the various
LED states for the different boards.
1.1.3.2 Check BSC Loading
Generate and print out the states of the faulty SBLs:
1. Select:
Commands -> Equipment Handling -> SBL State List
2. In ’Object Class’, enter the ’SBL’ parameter.3. In ’Unit Type’, enter the ’BSC’ parameter.
4. In ’Unit Number’, enter the ’01’ parameter.
5. Click on [ OK ].
6. Check that all the CPR, DTC, TCU, and SWITCH SBLs of the BSC are ’InTraffic’. They should not appear in the State List command report.
12 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 13/42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 14/42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 15/42
1 Basic Tasks
1.1.5 9130 BSC Evolution Backup/Restore
1.1.5.1 9130 BSC Evolution Backup from OMC-R
NEM terminal PC should be installed according to the Network ElementManager User Guide (3BK 21284 AAAA PCZZA) document.For the 9130 BSC Evolution Restore the 9130 BSC Evolution SoftwareInstallation (3BK 17430 3126 RJZZA) document is required.
To perform an 9130 BSC Evolution backup from the OMC-R:
1. Generate Complete BSS Software Package without ’Zip production’.
2. Create a tar archive of the SBPA and SBPB directories located in/alcatel/var/share/AFTR/SLD/<BssName>
cd /alcatel/var/share/AFTR/SLD/<BssName>
tar cvf <BSSName>.tar ./SBPA ./SBPB
where <BSSName> is the name of the directory.
The SBPC directory with the files according to the 9130 BSC Evolution softwareversion must be available on NEM terminal PC and located in the same placeas the tar backup archive.If SBPC directory is not available on NEM terminal PC then include it in thetar archive:
tar cvf <BSSName>.tar ./SBPA ./SBPB ./SBPC
3. Copy the tar archive to the NEM terminal PC.
You can use FileZilla ftp client software with a secure connection.
4. Free up the disk space on the OMC-R.
rm <BSSName>.tar
5. Untar the <BSSName>.tar archive located on NEM terminal PC.
6. Copy the content of SBPA, SBPB and SBPC directories in a new directory(backup directory).
7. Write the content of the backup directory on a CD to use later whenperforming 9130 BSC Evolution Restore from NEM PC ( Section 1.1.5.2 )
3BK 21268 AAAA PCZZA Ed.05 15 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 16/42
1 Basic Tasks
1.1.5.2 9130 BSC Evolution Restore from NEM PC
To perform an 9130 BSC Evolution restore from the NEM PC:
1. Insert the backup CD in the NEM PC CD-ROM drive.
2. Disable Windows XP Firewall .
3. Start the Linux from NEM .
4. From Linux NEM mount yhe CD:mount /mnt/cdrom
5. Write down filenames of the master file and descriptor file which will beused during the installation.
cd /mnt/cdrom
ls | grep ’^...M.W01.01A’
This command gives you the name of the master file.ls | grep ’MXSWDSCR’
This command gives you the name of the descriptor file.
6. Install the 9130 BSC Evolution software CD on NEMcd /mnt/cdrom/MXPF
ls |grep ’copy-to-build’
This command gives you the name of the copy script file.copy-to-build-<xxyy>.sh
xx is the project release
yy is from 01 to 99
./copy-to-build-<xxyy>.sh <BSS Master file name>
Wait until the following message appears:Copy successful
7. Run the following commands:cd /build/<BSS Master file name>/MXPF
ls |grep ’load-bsc-build’
This command gives you the name of the load script file.load-bsc-build-<xxyy>.sh
xx is the project release
yy is from 01 to 99
./load-bsc-build-<xxyy>.sh
Type the names of the master file and the descriptor file when requestmessage appears.
At the end of the installation the following message appears:Now your PC is ready to install an ATCA shelf.
Now the directory structure for MxPF platform installation part is created.
8. Stop the DHCP Server.[root@nem MXPF]# /etc/init.d/dhcpd stop
Shutting down dhcpd: OK
9. Connect the NEM PC to the 9130 BSC Evolution as described in the 9130BSC Evolution Software Installation document.
10. Continue with the software installation as described in 9130 BSC EvolutionSoftware Installation (3BK174303126RJZZA) starting with the section’OMCP, CCP & TPGSM Software Installation’.
16 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 17/42
1 Basic Tasks
1.2 From Transmission Terminal
1.2.1 Check Alarms on ATBX Boards
To check the alarms on the ATBX boards:
1. Connect the PC to the ATBX using the RS-232 cable.
2. Double click on the [ Transmission Terminal Program ] icon. The"Transmission Terminal Password" window appears.
3. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menuappears.
4. Select Session -> Connect
The "ATBX Connection Established" window appears.
5. Click on [ OK ]. The Main Menu appears again.
6. Select Services -> Alarm Collection
If the connection is OK, no active alarms appear.
If Alarm Collection indicates a ’Loss of CRC multiframe alignment’ alarmlocated on the MSC site, check that the CRC4 is disabled on the A-Trunk MSC.
1.2.2 Check Alarms on ASMC Boards
To check alarms on the ASMC boards:
1. Connect the PC to the ASMC using the RS-232 cable.2. Double click on the [ Transmission Terminal Program ] icon. The
"Transmission Terminal Password" window appears.
3. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menuappears.
4. Select Session -> Connect.
The "ASMC Connection Established" window appears.
5. Click on [ OK ]. The Main Menu appears again.
6. Select Services -> Alarm Collection
If the connection is OK, no active alarms appear.
If Alarm Collection indicates a ’Loss of CRC multiframe alignment’ alarmlocated on the MSC site, check that the CRC4 is disabled on the A-Trunk MSC.If Alarm Collection indicates a ’Loss of incoming 2M signal’ or an ’AIS 2M’alarm, check the PCM connection on the DDF.
3BK 21268 AAAA PCZZA Ed.05 17 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 18/42
1 Basic Tasks
1.2.3 Local Download of Generic Settings for G2TC
To perform a local download of the generic settings for a G2TC:
1. Start the LMT-CT software.
2. Enter the Password (if any) and click on [ OK ]. The Alcatel Main Menu
appears.
3. Select Session -> Connect
The "Connection Established" window appears.
4. Click on [ OK ]. The Main Menu appears again.
5. Select Service -> Data -> Download
6. Click on [ Browse ].
7. To chose the file to download, go to the LMTCT\B10 directory and selectone of the following paths:
G2 TC, ASMC board: LMTCT\B10\Settings\G2\<IMP120 or
IMP 75>\ASMC\<3_1_MAP or 4_1_MAP>\<BSCX.25 or MSCX.25>\
RACK<x>\SHELF<y>\SLOT <z>
G2 TC, ATBX board: LMTCT\B10\Settings\G2\<IMP120 or
IMP 75> \ ATBX \ <3_1_MAP or 4_1_MAP>\<BSCX.25 or
MSCX.25>\RACK<x>\SHELF<y>\SLOT <z>.
8. Click on [ OK ] and wait for the file to download.
1.3 From TC-NEM
1.3.1 E1 to STM1 Configuration
1.3.1.1 Prerequisites
The following prerequisites apply:
The 9125 TC was previously configured to an 9125 TC with TC STM1 board.
A "working" STM1 configuration file is ready to be downloaded from
TC-NEM.
The STM1 links must be physically installed on the STM1 daughter board
of the TCIF board.
Note: STM1 interfaces:
The STM1 interfaces are numbered from 1 to 4, instead of 240 E1 links
The TC can be pure STM1, pure E1 or mixed
One STM1 can carry up to 63 E1 (on VC12)
One STM1 port can be shared between A and A-ter interfaces.
18 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 19/42
1 Basic Tasks
1.3.1.2 Procedure
To move from E1 to STM1 configuration, perform the following steps:
1. If the 9125 TC with TC STM1 board was not previously declared on theOMC-R, perform the Declare an 9125 TC task.
2. If the STM1 interface was not previsouly declared on the OMC-R, declarethe requested STM1 interface from the OMC-R (STM1 interfaces andassociated STM1-TTPs are created in the TC).
3. Start the TC-NEM application. See also Local Connection and Remote Connection depending on the type of connection to the TC-NEM.
The "TC-NEM Communication" window opens.
4. To connect, from the menu bar select Serial -> Connect.
The TCIF panel opens.
5. Select the "STM1 Configuration" tab.
6. Open the default configuration file in a text editor or from the TC-NEMapplication.
In the "STM1 Configuration" tab, in the "Get" frame click on [ Current ].
The current configuration file opens.
7. Import the file in the Configuration folder in order to change it.
In the "STM1 Configuration" tab, click on [ Import ].
8. Modify the current configuration file.
In the first ’Browse’ section, look for the saved file in the Configuration
folder.
Once the file is selected in the ’Browse’ field, click on [ View ].The "STM1 View" window opens.
9. Make the necessary changes in the configuration file.
10. In the’ File Name’ field type a name for the modified file and click on [ Save ].
11. Click on [ OK ] to confirm the changes.
12. Check the file.
Click on [ Check ]. If the check result is not OK, correct the errors andthen save the file again.
13. Download the configuration file from the TC-NEM to the TC STM1-IP subrack.
In the "Set" frame click on [ Candidate ].
Note: Once it is downloaded, the STM1 configuration is identified as the ‘candidate’configuration.
14. If a candidate configuration is applied for the first time, unlock and verifySTM1_TTPs.
15. Apply the candidate configuration.
Click on [ Apply ].
3BK 21268 AAAA PCZZA Ed.05 19 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 20/42
1 Basic Tasks
1.3.2 STM1 to E1 Configuration
To move from STM1 to E1 configuration, perform the following steps:
1. Start the TC-NEM application. See also Local Connection and Remote Connection depending on the type of connection to the TC-NEM.
The "TC-NEM Communication" window opens.2. To connect, from the menu bar select Serial -> Connect.
The TCIF panel opens.
3. Select the "STM1 Configuration" tab.
4. Open the default configuration file in a text editor or from the TC-NEMapplication.
In the "STM1 Configuration" tab, in the "Get" frame click on [ Current ].
The current configuration file opens.
5. Import the file in the Configuration folder in order to change it.
In the "STM1 Configuration" tab, click on [ Import ].
6. Modify the current configuration file.
In the first ’Browse’ section, look for the saved file in the Configuration
folder.
Once the file is selected in the ’Browse’ field, click on [ View ].The "STM1 View" window opens.
7. Make the necessary changes in the configuration file.
8. In the’ File Name’ filed type a name for the modified file and click on [ Save ].
9. Click on [ OK ] to confirm the changes.
10. Check the file.
Click on [ Check ]. If the check result is not OK, correct the errors andthen save the file again.
11. Download the configuration file from the TC-NEM to the TC STM1-IP subrack.
In the "Set" frame click on [ Candidate ].
Note: Once it is downloaded, the E1 configuration is identified as the ‘candidate’configuration.
12. Apply the candidate configuration.
Click on [ Apply ].
20 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 21/42
1 Basic Tasks
1.4 From BTS Terminal
1.4.1 Call Test
Note: In the case of an extended cell, tests must be performed at a distance of
approximately 30Km from the BTS site.
1.4.1.1 Identify Signaling Using BTS Terminal
To identify signalling using the BTS terminal:
1. Connect and start the BTS Terminal.
2. Select:
BTS Terminal Window -> Show -> Logical Configuration -> RadioChannel Configuration.
3. The "BTS_LOG_CONFIG_REQUEST" window appears.
4. Check that the radio channels are assigned as signaling links and traffic
channels (FCCH, SCH, BCCH, CCCH, SDCCH, SACCH, TCH).
1.4.1.2 Unlock Cell Under Test
Unlock the cell under test:
1. At the BTS Terminal, unlock the impacted cell. Select:
BTS Terminal Window -> Commands -> SBL Management
2. Select ’BTS_TEL’ for ’SBL ID’.
3. Click on [ Init ].
4. Wait for the successful ’SBL Init report’.
1.4.1.3 Activate Mobile Trace Function
Check the handling of radio calls in the timeslots of each FU:
Make radio calls on all the timeslots (RTS) of each FU
Make one incoming call on each BTS from a fixed station (ask somebody to
call you)
Check speech quality in both directions (subjectively)
Make calls to the voice mailbox for all the remaining timeslots.
For each call:
1. Check on the trace mobile that the call is handled by the BTS.2. Check the cell number (hexadecimal).
3. Check the used BCCH frequency.
4. Check the used radio resource radio channel (ARFCN).
5. Check the timeslot (TN).
Note the result of each call.
3BK 21268 AAAA PCZZA Ed.05 21 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 22/42
1 Basic Tasks
1.4.2 Locally Load Software on 9100/9110 Micro BTS
If the BTS is connected to the Abis, you cannot perform this procedure.
To download the BTS from the BTS terminal:
1. Start the BTS Terminal:
Connect the PC to the SUM board (between COM1 or COM2 and the
’BTS TERMINAL’ connector) using the BTS terminal cable
Launch the BTS Terminal:Start -> Programs -> BTS-Terminal release B10 -> BTS-Terminalrelease B10
At the BTS Terminal: User/Group name: ’UPGRAD’ Password:
’SUMSUP’
Click on [ Logon ].
2. Set the serial interface parameters and the path to Inventory software, ifnot already done:
Select Settings -> Terminal
Under the ’Serial Interface’ tab, select the required port (COM1 or
COM2) and baud rate of 115200
Select the ’Misc’ tab, and if not already done, click on [ Browse ] and select
the path to INVENTAR (usually C:\WINVENT\Program\pwinvent.exe)
Click on [ OK ].
3. Establish the connection:
File -> Connect/Disconnect.
The connection to the OMU has been established! messageappears.
4. OPTION: Only if the files are not already on the PC:
Create a directory: C:\bts_files
Copy all the files to the directory from the diskette.
5. Download the BTS with the BTS terminal:
Commissioning ->Download-> BTS-SW...
Master File: BM*SAT**.MSF
CPF File: 00o*AT**.DDL
CODA File: CODA.990The CODA.990 is in the directory C:\bstw\10\commtest.
Click on [ Browse ] to give the path of each file: C:\bts_files
Click on [ Download ].
22 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 23/42
1 Basic Tasks
6. Check the downloading of the BTS: A disconnection appears duringthe download. Wait until the The connection to the OMU has been
established! message appears.
Some messages/windows may appear during download, such as:
No operator action during next 80 seconds!!!
BTS SW download in progress...
Start operational software...
Initialization in progress....
7. WAIT for the "Edit frequencies" window:
Select the ’Frequency band’ (GSM 900/DCS 1800/DCS 1900/EGSM)
Select the test frequencies by clicking on [ Add ] or [ Remove ] in the
’Available ARFNs’ list to have the correct frequencies in the ’Selected
ARFNs’ list
Click on [ Submit ].
8. Create and initialize the sector:
To create the sectors, select Commissioning->Edit Sector Mapping
Click on [ SAVE ]
To initialize sectors, select Commissioning->Initialization->All sectors
Commissioning->End Commissioning
Some automatic actions start. At the end, the following message
appears:Do you want to execute INVENTAR now? (This is the last
possibility before BTS-Auto-Reset)
Click on [ YES ] to perform a Remote Inventory.
3BK 21268 AAAA PCZZA Ed.05 23 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 24/42
1 Basic Tasks
1.5 Program Initial Transmission Settings
1.5.1 G1 BTS (MKII), G2 BTS
Note: For a G1 BTS, the transmission setting files for the initial programming are
delivered with the program. Refer to the following table to determine which filehas to be downloaded according to the field configuration.
File name Numberof SMBSboards
Qmux onTS
R bit on TS S bit on TS On Directory/SETTINGS /G1/MKIIBTS
q01r_.hex 1 01 No S bit No R bit ONE_SMBS/
q18r31.hex 1 18 17 31 ONE_SMBS/
q16r31.hex 1 16 15 31 ONE_SMBS/
q01r02.hex 1 01 17 02 ONE_SMBS/
q01r_.hex 2 01 No S bit No R bit TWO_SMBS/
q18r31.hex 2 18 17 31 TWO_SMBS/
q16r31.hex 2 16 15 31 TWO_SMBS/
q01r02.hex 2 01 17 02 TWO_SMBS/
q00r31.hex 2 00 00 31 TWO_SMBS/
1.5.1.1 Establish Connection to Local Board
To establish a connection to the local board:
1. Connect the Transmission Terminal to the local board of the BTS.
2. Disconnect the PCM cables to isolate the transmission module beforetrying to establish a connection.
3. Start the Transmission Terminal software. Click on [ OK ] when the passwordis requested.
4. Select Session-> Connect
5. Select Broadcast Address. Click on [ OK ] when the broadcast warningwindow appears.
6. Wait until the connection is established.
24 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 25/42
1 Basic Tasks
1.5.1.2 Download Transmission Files
To download the transmission files:
1. Select File- > Download
2. Select the required data file. Click on [ OK ]. Wait until the download isfinished.
3. Disconnect from the board. SelectFile -> Disconnect
4. Disconnect the cable from the board. Reconnect the PCM cables to the localboard of the BTS.
1.5.2 9100 BTS
You can download the transmission files in two ways:
Download files generated by the OMC-R
Download files created with the 9100 BTS Terminal.
1.5.2.1 Download Files Generated by OMC-R
To download files generated by the OMC-R:
1. Connect the 9100 BTS Terminal to the local board (SUM) of the 9100 BTS.
2. Disconnect the Abis link cables before trying to establish a connection.
3. Start the 9100 BTS Terminal software.
4. Select Settings-> Transmission
5. Click on [ Download ]. In the "Open File" window, select the required datafile. Click on [ OK ].
1.5.2.2 Download Files Created with 9100 BTS TerminalTo download files created with the 9100 BTS Terminal:
1. Connect the 9100 BTS Terminal to the local board (SUM) of the 9100 BTS.
2. Disconnect the Abis link cables before trying to establish a connection.
3. Start the 9100 BTS Terminal software.
4. Select Settings -> Transmission.
5. Click on [ Initial settings ]. Click on [ Get Config ].
6. Insert the values for the following fields: Qmux address, Qmux in TS (1 ),Baud rate (1200).
7. Click on [ Transmit ].
8. Wait until the download is successfully finished.
3BK 21268 AAAA PCZZA Ed.05 25 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 26/42
1 Basic Tasks
1.6 Common Tasks
1.6.1 Inventory
For each subrack, check for the presence, number, type, and layout of the
boards against the ’Hardware Configuration’ site documentation.
1.6.2 Hardware Technical Level
Check each board’s technical release level marked on the label against theBSS hardware technical release document.
1.6.3 Connect BTS
The following figure shows the connection between the BTS and BSC.
PCM toprevious BTSr BSC site
Terminal block
Equipmentterminal block
to BIEBTS link B
BTS 1
to BIEBTS link A
TX
RX
1
2
TX
RX
2
to BIEBTS link B
BTS 2
to BIEBTS link A
TX
RX
PCM toprevious BTSor BSC site
Terminal block
to BIEBTS link B
BTS 3
to BIEBTS link A
TX
RX
1
2
TX
RX
2
PCM to nextsite (if any)
Jumpers
2
2
NTPM
NTPM
NTPM
(1) PCM looped
(2) PCM connected
Figure 1: Connect BTS to BSC
26 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 27/42
1 Basic Tasks
To connect the BTS:
1. Locate the Alcatel-Lucent Digital Distribution Frame (DDF).
2. Use the labels on the DDF to find the two positions, Emission and Reception,of the Abis link (link A) of the BTS.
3. If the BTS is:
First on the chain: Connect the PCM from the first Abis link (link A) of the
BTS in the DDF according to the correct position of the BTS
In the middle of the chain: In the DDF, connect the PCM from the first
Abis link (link A) of the BTS to the second Abis link (link B) of the previous
BTS. Ensure that the jumper connection between the two Abis links of
the BTSs is done according to the following rule:
The emission of the Abis link A is connected to the reception of the
Abis link B
The reception of the Abis link A is connected to the emission of
the Abis link B.
1.6.4 Disconnect BTS
To disconnect the BTS:
1. Locate the Alcatel-Lucent Digital Distribution Frame (DDF).
2. Use the labels on the DDF to find the two positions, Emission and Reception,of the Abis link (link A) for the BTS.
3. If the BTS is:
First on the chain: Disconnect the PCM from the first Abis link (link A) of
the BTS from the DDF
In the middle of the chain: In the DDF, disconnect the PCM from the
first Abis link (link A) of the downstream BTS from the second Abis link
(link B) of the previous BTS. Remove the jumpers between the two Abis
links of the BTSs from the DDF.
1.6.5 Connect Jumper
To connect the jumper:
1. Locate the Alcatel-Lucent Digital Distribution Frame (DDF).
2. Use the labels on the DDF to locate the two positions, Emission andReception, of the Abis link for the BTS.
3. Insert a loop on the Emission position. Insert a loop on the Receptionposition.
3BK 21268 AAAA PCZZA Ed.05 27 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 28/42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 29/42
2 General Information
2 General Information
This section describes the safety rules and precautions that must be followedby all personnel.
3BK 21268 AAAA PCZZA Ed.05 29 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 30/42
2 General Information
2.1 Faults and Anomalies
2.1.1 ALCATEL 3000 Failure Report
During the process:
Any faulty components, supplies, or replacement parts must be returned
with an ALCATEL 3000 FRD failure report form to the ALCATEL person
responsible for the operation
The ALCATEL 3000 number must be entered in the ’Title’ column of the
Faults reports/Actions form section of the CCL
If a module from the replacement kit is used to replace a faulty module
unrelated to the operation, the replacement must be noted in the
’Manufacturers comments’ section of the CCL.
2.1.2 Fault ReportsBugs found when preparing and carrying out work must be reported bycompleting and sending a fault report to the Alcatel-Lucent person responsiblefor the operation on the site.
2.2 Safety Rules
This section contains safety rules and precautions for:
Installation personnel on the site
Equipment under power
Equipment emitting RF power
Electrostatic precautions.
Death or serious physical harm to personnel and damaged equipment mayresult by mishandling.You must be familiar with the local safety requirements. Read the GeneralSafety Instructions.
2.2.1 General Safety RequirementsIn terms of general safety requirements:
Always refer to local safety regulations and accident prevention
In France, apply Labor Legislation and decree Nx92-158
Obtain safety requirements linked to equipment during installation in
accordance with IEC 950.
30 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 31/42
2 General Information
2.2.2 Safety Prerequisites
2.2.2.1 Customer
The customer:
Is able to warn the installation staff in case of danger
Is able to communicate with the installation team via a direct line of
communication
Is able to provide a list of collocated radiating equipment.
2.2.2.2 Installation Team
Inform the customer about:
Date of arrival
Duration of work
Number of technicians onsite
Staff authorized to enter the site
The contact person.
2.2.2.3 Before You Start
Before you start:
Verify that the site inspection is done and that the results are documented in
an inspection report
Ensure good illumination in your place of work
Indicate danger sources
Check that the compliance perimeter to electromagnetic field exposure
is marked
Be prepared to provide first aid
Be familiar with the telephone numbers of the:
Fire brigade
Hospital
Police
Customer contact person.
Take into account special site risks
Check working conditions onsite.
Do not work alone onsite.
3BK 21268 AAAA PCZZA Ed.05 31 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 32/42
2 General Information
2.2.3 Safety Requirements IEC 950 (Excerpt)
The following information is an excerpt from the IEC 950 safety requirements:
The 230 V electrical supply must be recognizable
The equipment power supply is protected by 300 mA circuit breakers
The service point power supply is protected by 30 mA circuit breakers
Do not extend the maximum load indicated at the service point
Insure a proper protective earth connection (resistance <0.1 Ohm)
The earth conductor outside the rack is one of the following:
Bare
Sleeved in green/yellow
Transparent insulation.
The protective earth connection inside the rack is terminated with a crimpcable lug
The feed line to the circuit breaker is protected against physical contact.
2.2.4 Safety Rules for Equipment Under Power
For maintenance or procedure purposes, field operators may have to workon equipment under power (-48 VDC or -60 VDC). This means that it ispossible to touch some parts under power that are only protected by heavyfuses. All activities must be carried out carefully to avoid short circuits andto prevent serious personal injury.
Remove all conductive objects from the hands, such as rings, bracelets, metallicwrist watches and so on. Use appropriate insulated tools for your activities.
2.2.5 Equipment Emitting RF Power
When working with equipment emitting FR power:
Do not enter into the compliance RF perimeter for the general public and
non-authorized persons
Switch off the RF emission if you want to enter into the compliance RF
perimeter for workers
Do not stand in the compliance RF perimeter for general public if not
necessary
People with electronic medical devices (pacemakers, hearing aids) and
pregnant women must identify themselves to Alcatel-Lucent representatives.
32 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 33/42
2 General Information
2.2.6 Electrostatic Precautions
2.2.6.1 Environment
Observe the following electrostatics precautions:
Ensure that work benches, stools, and floor mats have a conducting surface
connected to the ground. Before handling static-sensitive components and
assemblies, ground yourself to the conducting surface using an anti-static
wrist strap.
When handling static-sensitive components and assemblies, do not wear
or use clothes made of wool, nylon, or any other synthetic material. Such
fabrics are major sources of static build up.
When handling static-sensitive components and assemblies, do not use
gloves and finger covers, unless they are made of cotton.
2.2.6.2 ToolsObserve the following electrostatics precautions:
Ensure that all tools which come into contact with static-sensitive
components are at the same voltage level as the conducting work surfaces
and floor mats. These tools include soldering irons, oscilloscopes, power
supplies, and metal parts of tools and fixtures that are used to hold,
assemble, or test Printed Board Assemblies (PBA).
Do not use rough cleaners or erasers to clean the gold-plated contacts
on PBAs
Do not mark a PBA with lead pencil or any other writing instrument
Do not use synthetic brushes to clean equipment and do not use dry
cleaning methods.
3BK 21268 AAAA PCZZA Ed.05 33 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 34/42
2 General Information
2.2.6.3 Transportation and Storage
Observe the following electrostatics precautions:
Pack all electronic components and modules in containers used to transport
and store static-sensitive components and use aluminum container tubes
if possible. If not, insert the components terminations into electricallyconductive foam
Before shipping a PBA, wrap it in a conducting synthetic bag or in aluminum
foil. Also pack the PBA in a polyethylene transport box
Before shipping a PBA which has Metal Oxide Semiconductor (MOS)
components, ensure that an appropriate warning symbol is displayed on
the package
Store spare PBAs in their appropriate polyethylene boxes. Keep the boxes
closed except when access to their contents is required
Do not store PBAs in an area where the air is polluted with smoke, dust,dangerous gases, or other airborne particles that may cause damage
Do not stack PBAs side-by-side or on top of each other with the board
surfaces or components in contact with one another
Before cleaning a PBA, remove or disconnect the damage protection, such
as protective foam, to allow the PBA to be cleaned thoroughly. Replace the
damage protection upon completion of the task.
2.2.6.4 Components and PBAs
Observe the following electrostatics precautions:
Components and PBAs are not in protective containers, and must only be
handled by trained personnel in static-controlled work areas
Before removing a PBA from an equipment rack, discharge any static by
touching the metal frame of the rack with your hand
Always handle a PBA by the edges
Do not handle or carry a PBA by any mounted components
Do not handle a PBA by the gold-plated contact terminals and do not apply
direct pressure to the components
Do not touch PBA connection pins or conductor paths
Do not touch PBAs with wet hands
Place PBAs that have been removed during maintenance with the soldered
side down on a conductive surface
Do not scratch or rub the soldered side of a PBA with a sharp or rough object
Do not repair PBAs in the switch room
Do not handle components and assemblies by their leads
Do not use excessive force when inserting connection boards.
34 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 35/42
2 General Information
2.3 Fill In a CCL
A generic CCL is used for all installation procedures.
Each commissioning procedure has its own CCL, identical in structure to theinstallation CCL, differing in task descriptions.
Filling in an installation and commissioning CCL is almost the same process.For more information, refer to the following sections.
Document Title
Identification
1Customer
2Country
OMC−R Site
Address::
Name:
Name:
Address::3
4ALCATEL Representative (s)
5Customer Representative (s)
6Customer Contractor Representative (s)
Start End Duration
7
89
General Remarks from Customer General Remarks from Alcatel
0
3BK 21268 AAAA PCZZA Ed.05 35 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 36/42
2 General Information
Applicable Documents
10
Applicable ITL 11
EditionDocument ReferenceDocument Title
3BK 17430 0245 RJZZAMove A9130 BSC Evolution, Same MFS,
Different MSC, Same OMC−R
B10 BSS Methods Handbook 3BK 21263 AAAA PCZZA
BSS Configuration Handbook 3BK 21201 AAAA PCZZA
BSS Surveillance Handbook 3BK 21206 AAAA PCZZA
Network Reconfiguration Recommendations 3BK 21209 AAAA PCZZA
Evolium A9125 Compact TC User Guide 3BK 21230 AAAA PCZZA
Information
OMC−R
12
Hostname
User Name
Password
Cases and Options
C1
13
The target TC is an A9125 Compact TC. Change TRAU LOUDNESS andHR PRESENCE parameters
The target TC is a G2 TC. Modify CRC4 value
Change LAC of the cells
C2
C3
Change CI of the cellsC4
There is at least one MFS−TC linkC5
36 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 37/42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 38/42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 39/42
2 General Information
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Section Title
Unavailability Duration Sheet
UnavailabilityType
Equipment Date Start Time End Time
22 23
24
25 26 27
Figure 4: How to Fill in the Unavailability Duration Sheet
22 Write the unavailability type:
T for traffic interruption
R for traffic reduction
S for loss supervision
(T, R and S could be held simultaneously)
23 Type the equipment wih its number (eg BTS-1)
3BK 21268 AAAA PCZZA Ed.05 39 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 40/42
2 General Information
24 Write the title of the paragraph where the unavailability occured
25 Date expressed as: yy/mm/dd
26 Start time expressed as: hh/mm/ss
27 End time expressed as: hh/mm/ss
Anomaly Sheet
28 29
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Section Title:
Brief Description of the anomaly:
Anomaly Report: Y/N
Name:
Date:
Name:
Date:
Name:
Date:
Name:
Date:
Name:
Date:
Name:
Date:
Description Solved by
Figure 5: How to Fill in the Anomaly Sheet
40 / 42 3BK 21268 AAAA PCZZA Ed.05
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 41/42
2 General Information
28 Section Title: Title of the paragraph where the anomaly occured
Brief description of the anomaly: Summarize the anomaly (detailsmust be in anomaly report)
Anomaly report : Anomaly report was sent or no
29 Name of the technician who solved the anomaly
Date of anomaly solving
3BK 21268 AAAA PCZZA Ed.05 41 / 42
8/13/2019 212680000 e 05
http://slidepdf.com/reader/full/212680000-e-05 42/42
2 General Information