  • 20to2T5m100cm Images

    Van Graves

    February 13, 2014

  • 2 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Overall View with 5 Cryostats• Beam extends to Z=1-0m

    • Target chamber extends to Z=-5m

    • Placeholder focusing magnet shown near Z=-5m

  • 3 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 4 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Target Region• Chamber extension would require supports and helium channels

  • 5 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 6 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Target Extraction• Beam path to focusing magnets is at slight angles to the magnetic axis

    • Upstream end of main cryostat Z=-2.3m, target length 3.6m inside cryostat

    • Target cannot be extracted without first removing focusing magnet(s)

  • 7 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Front Elevation Views

  • 8 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 9 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 10 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Target Chamber Views

  • 11 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 12 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Target Chamber Isometrics

  • 13 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

  • 14 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Downstream Beam Windows• Double Be windows at both ends of each cryo module

    • 23cm IR, 1mm thick, 1cm gap

    • All these are replaceable maintenance items

  • 15 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Window Close-up

  • 16 Managed by UT-Battellefor the U.S. Department of Energy 20to2T5m100cm Images 13 Feb 2014

    Window AttachmentTungsten shield module

    Gasket requires precise surface on shielding

    Be windows

    Interstitial gap requires monitoring(line not shown)

    Space for fasteners (tapped hole in shielding not shown)