2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
1
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES!
Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
How to take this course.
1. Download and Print the test questions.
2. Login to your account with your ID and password.
3. Viewing your status page, scroll down and click on “Click here to start this course”.
4. Begin viewing the web pages. Refer to your
printed test to find the correct answers. The questions track the web pages.
5. As you find the answers, circle them on your printed copy.
6. At the end of each section, you’ll enter the quiz which is the same as your printed test. Refer to your circled answers when actually answering the quiz on the web.
7. Upon passing, you will proceed to the next section. If failed to pass, you will be moved to the beginning of that section for more review.
Mobile users – Many current mobile devices are compatible with AnytimeCE and will probably work. If not, use a desktop or laptop computer to complete your course.
Quiz 1 1. The size of each water meter is based on
the _______ demand of the system.
average
typical
minimum
total
none of the answers provided 2. The pressure loss through backflow
prevention devices shall be included in the pressure loss calculations of the system, and the water supply pipe and meter shall be adequately sized to provide for any such pressure loss.
True
False
3. Equivalent fixture values as show in Table 610.3 are only for cold water demand.
True
False 4. The WSFU for a clothes washer in a private
home is _______ of cold water.
1.0
2.0
3.0
4.0
5.0 5. To get the total WSFU for a system, add all
of the WSFU of the fixtures together.
True
False
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
2
6. The developed length of the system is the total length of the pipes to the most remote outlet.
True
False 7. In designing a water system, use the
_______ pressure in the water main.
minimum
typical
average
maximum Quiz 2 – Size Water System for Studio Apartment (Diagram on page 15) 1. Design Pressure at Meter Base is _______.
25 psi
45 psi
44 psi
52 psi
76 psi 2. The total demand WSFU for the entire
system is _______.
5.0
6.5
9.0
15.5
24.0 3. The total WSFU to the water heater demand
is _______.
5.0
6.5
7.5
15.5
24.0 4. The longest developed length from the
meter to the most remote outlet is ______.
32 ft.
56 ft.
85 ft.
91 ft.
102 ft. 5. The design pressure range for sizing this
system is _______.
30-45 psi
46-60 psi
60 psi
6. The Maximum allowable length column for this system using Table 610.4 is _______.
40
60
80
100
150 7. The Meter and Street service is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 8. The Building Supply and branch service size
is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 9. The main branch on this system has a total
demand of _______ WSFU.
5.0
6.5
9.0
15.5
24.0 10. The branch supply to the water heater is
_______.
3/4 inch
1 inch
1-1/2 inch
2 inches Quiz 3 – Size Water System for Small House (Diagram on page 16) 1. Design Pressure at Meter Base is _______.
35 psi
45 psi
47 psi
52 psi
76 psi 2. The total demand WSFU for the entire
system is _______.
6.5
10.5
15.5
24.0
28.5
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
3
3. The total WSFU to the water heater demand is _______.
6.5
10.5
15.5
24.0
28.5 4. The longest developed length from the
meter to the most remote outlet is _______.
32 ft.
57 ft.
72 ft.
91 ft.
102 ft. 5. The design pressure range for sizing this
system is _______.
30-45 psi
46-60 psi
60 psi 6. The Maximum allowable length column for
this system using Table 610.4 is _______.
40
60
80
100
150 7. The Meter and Street service is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 8. The Building Supply and branch service size
is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 9. Branch 1 on this system has a total demand
of _______ WSFU.
4.0
6.5
8.0
11.5
16.5
10. The size of the pipe to Branch 1 is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 11. Branch 2 on this system has a total demand
of _______ WSFU.
4.0
6.5
8.0
10.5
16.5 12. The size of the pipe to Branch 2 is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 13. The total hot water demand WSFU for the
system is _______.
5.0
7.5
10.5
14.0 14. The size of the pipe feeding the Water
heater is ________.
3/4 inch
1 inch
1-1/2 inch
2 inches Quiz 4 – Size Water System for Town House (Diagram on page 17) 1. Design Pressure at Meter Base is _______.
35 psi
38 psi
45 psi
47 psi
52 psi 2. The total demand WSFU for the entire
system is _______.
10.5
16.5
19.5
21.5
28.5
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
4
3. The total WSFU to the water heater demand is _______.
6.5
9.5
10.5
13.0
24.0 4. The longest developed length from the
meter to the most remote outlet is _______.
32 ft.
70 ft.
80 ft.
84 ft.
96 ft. 5. The design pressure range for sizing this
system is _______.
30-45 psi
46-60 psi
60 psi 6. The Maximum allowable length column for
this system using Table 610.4 is _______.
40
60
80
100
150 7. The Meter and Street service is ________.
3/4 inch
1 inch
1-1/2 inch
2 inches 8. The Building Supply and branch service size
is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 9. Branch 1 on this system has a total demand
of _______ WSFU.
6.5
8.0
13.0
16.5
20.5
10. The size of the pipe to Branch 1 is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 11. Branch 2 on this system has a total demand
of _______ WSFU.
4.0
6.5
7.5
10.5
12.5 12. The size of the pipe to Branch 2 is
________.
3/4 inch
1 inch
1-1/2 inch
2 inches 13. The total hot water demand WSFU for the
system is _______.
7.0
13.0
15.5
18.0 14. The size of the pipe feeding the Water
heater is _________.
3/4 inch
1 inch
1-1/2 inch
2 inches Quiz 5 – Size Water System for Rambler Style Home (Diagram on page 18) 1. Design Pressure at Meter Base is _______.
35 psi
38 psi
45 psi
47 psi
52 psi 2. The total demand WSFU for the entire
system is _______.
10.5
16.5
19.5
20.0
25.5
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
5
3. The total WSFU to the water heater demand is _______.
6.5
9.5
10.5
13.0
17.0 4. The longest developed length from the
meter to the most remote outlet is _______.
32 ft.
60 ft.
72 ft.
83 ft.
94 ft. 5. The design pressure range for sizing this
system is _______.
30-45 psi
46-60 psi
60 psi 6. The Maximum allowable length column for
this system using Table 610.4 is _______.
40
60
80
100
150 7. The Meter and Street service is ________.
3/4 inch
1 inch
1-1/2 inch
2 inches 8. The Building Supply and branch service size
is ________.
3/4 inch
1 inch
1-1/2 inch
2 inches 9. Branch 1 on this system has a total demand
of _______ WSFU.
6.5
8.0
10.5
13.0
21.0
10. The size of the pipe to Branch 1 is _______.
3/4 inch
1 inch
1-1/4 inch
2 inches 11. Branch 2 on this system has a total demand
of _______ WSFU.
4.0
6.5
7.5
10.5
12.5 12. The size of the pipe to Branch 2 is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches 13. Branch 3 on this system has a total demand
of _______ WSFU.
4.0
6.5
8.0
10.5
12.5 14. The size of the pipe to Branch 3 is _______.
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inches 15. The total hot water demand WSFU for the
system is _______.
10.0
13.5
17.0
21.5 16. The size of the pipe feeding the Water
heater is ________.
3/4 inch
1 inch
1-1/2 inch
2 inches
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
6
Quiz 6 – Size Water System for 2 Story House (Diagram on page 19) 1. Design Pressure at Meter Base is _______.
45 psi
47 psi
52 psi
65.5 psi
78 psi 2. The total demand WSFU for the entire
system is _______.
14.5
16.5
19.5
25.5
29.0 3. The total WSFU to the water heater demand
is _______.
9.5
10.5
13.0
18.0
27.5 4. The longest developed length from the
meter to the most remote outlet is _______.
101 ft.
122 ft.
140 ft.
143 ft.
158 ft. 5. The design pressure range for sizing this
system is _______.
30-45 psi
46-60 psi
60 psi 6. The Maximum allowable length column for
this system using Table 610.4 is _______.
40
60
80
100
150 7. The Meter and Street service is _______.
3/4 inch
1 inch
1-1/2 inch
2 inches
8. The Building Supply and branch service size is _______.
3/4 inch
1 inch
1-1/4 inch
2 inches 9. Branch 1 on this system has a total demand
of _______ WSFU.
6.5
8.0
10.5
13.0
21.0 10. The size of the pipe to Branch 1 is _______.
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inches 11. Branch 2 on this system has a total demand
of _______ WSFU.
4.0
6.5
7.5
10.5
12.5 12. The size of the pipe to Branch 2 is _______.
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inches 13. Branch 3 on this system has a total demand
of _______ WSFU.
4.0
6.5
7.5
10.5
12.5 14. The size of the pipe to Branch 3 is _______.
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inches
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
7
15. The total hot water demand WSFU for the system is _______.
9.5
11.5
15.5
18.0
16. The size of the pipe feeding the Water heater is ________.
1/2 inch
3/4 inch
1 inch
1-1/2 inch
2 inches Quiz 7 Flushometers
Questions 1 – 10 refer to the above drawing 1. Branch A is sized for _______ WSFU.
40
70
90
105
125 2. Branch B is sized for _______ WSFU.
48
55
63
87
118 3. Branch C is sized for _______ WSFU.
48
55
63
87
188
4. Branch D is sized for _______ WSFU.
40
70
90
105
125 5. Branch E is sized for _______ WSFU.
48
55
63
87
118 6. Branch F is sized for _______ WSFU.
93
107
185
278
363
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
8
7. Branch G is sized for _______ WSFU.
40
70
90
105
125 8. Branch H is sized for _______ WSFU.
48
55
63
87
118
9. Branch I is sized for _______ WSFU.
93
107
188
278
368 10. Given Design minimum pressure of 65 psi,
length 90, what is the minimum size for Branch I?
3/4
1
1-1/4
2
2-1/2
Questions 11 – 21 refer to the above drawing 11. Branch A is sized for _______ WSFU.
40
70
90
105
125
12. Branch B is sized for _______ WSFU.
48
55
63
87
118
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
9
13. Branch C is sized for _______ WSFU.
93
107
188
278
363 14. Branch D is sized for _______ WSFU.
40
70
90
105
125 15. Branch E is sized for _______ WSFU.
45
70
90
105
125 16. Branch F is sized for _______ WSFU.
107
118
233
305
500 17. Branch G is sized for _______ WSFU.
45
70
90
105
125 18. Branch H is sized for _______ WSFU.
107
188
248
253
278 19. Branch I is sized for _______ WSFU.
90
250
375
425
750 20. Branch J is sized for ______ WSFU.
107
188
238
253
278 21. Given Design min. press. of 52 psi, length
75, what is the min. size for Branch J?
3/4
1
1-1/4
2
2-1/2 Quiz 8 1. The maximum velocity of water in a cold
water copper pipe is _________ per second.
3 feet
5 feet
8 feet
12 feet
15 feet 2. The maximum velocity of water in a hot
water copper pipe is _________ per second.
3 feet
5 feet
8 feet
12 feet
15 feet 3. The maximum velocity of water in a cold
water PEX tube is _________ per second.
3 feet
5 feet
8 feet
12 feet
15 feet 4. The maximum velocity of water in a hot
water PEX tube is _________ per second.
3 feet
5 feet
8 feet
12 feet
15 feet 5. Drinking water treatment units shall comply
with NSF 42 or NSF 53.
True
False
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
10
6. Discharge from all drinking water treatment units shall enter the drainage system through an air gap.
True
False 7. The tubing to and from drinking water treatment units shall be of a size and material as recommended
by the manufacturer.
True
False 8. The minimum size connection to a residential water softener is _________.
1/2 inch
3/4 inch
1 inch
none of the answers provide
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
11
Step 1. Determine design pressure to building. Use minimum pressure at meter plus or minus elevation at 0.5 psi per foot difference.
Min press – (0.5 x Ft. above) = __________________________________
Min press + (0.5 x Ft. below) = __________________________________
Step 2. Table 610.3 Determine the number of Cold / Hot Water WSFU for the system.
TABLE 610.3 WATER SUPPLY FIXTURE UNITS (WSFU)
Fixture Type Fixtures Cold WSFU Total WSFU - Cold Hot WSFU Total WSFU Hot
Bath
Tub / Shower 4.0 4.0
Shower 2.0 2.0
Water Closet 2.5 __________
Bath sink 1.0 1.0
Laundry
Laundry sink 1.5 1.5
Clothes washer 4.0 4.0
Kitchen
Kitchen sink 1.5 1.5
Dish washer 1.5* 1.5
Hose Bibb 2.5 __________
Hose Bibb - Add. 1.0 __________
Totals
Important: Total System WSFU = Total Cold Water WSFU plus dishwasher WFSU
Branch 1 Cold WSFU = ___________________________________ = ____________
Hot WSFU = ___________________________________ = ____________
Branch 2 Cold WSFU = ___________________________________ = ____________
Hot WSFU = ___________________________________ = ____________
Branch 3 Cold WSFU = ___________________________________ = ____________
Hot WSFU = ___________________________________ = ____________
Branch 4 Cold WSFU = ___________________________________ = ____________
Hot WSFU = ___________________________________ = ____________
Total System Demand: Total of Branch 1 + 2 + 3 + 4 = ________________________________
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
12
Step 3. Determine the Hot Water demand for system. This will be used in Step 8 to size the branch line to the water heater. Hot water system demand = total of hot water WSFUs from each branch.
Branch 1 – total of hot water WSFU = ___________________________________= ____________
Branch 2 – total of hot water WSFU = ___________________________________= ____________
Branch 3 – total of hot water WSFU = ___________________________________= ____________
Branch 4 – total of hot water WSFU = ___________________________________= ____________
Total Hot Water Demand = Total of Branch 1 + 2 + 3 + 4 hot WSFU = ______________________
Step 4. Determine longest run of pipe to the remote outlet. (From Meter Base) Branch 1: Length of Cold: ____________________________________________ = ____________
Length of Hot: _____________________________________________ = ____________
Branch 2: Length of Cold: ___________________________________________= ____________
Length of Hot: ____________________________________________ = ____________
Branch 3: Length of Cold: ___________________________________________= ____________
Length of Hot: ____________________________________________ = ____________
Branch 4: Length of Cold: ___________________________________________= ____________
Length of Hot: ____________________________________________ = ____________
Longest run to remote outlet is __________ ft. (Branch _______ Cold / Hot)
Step 5. Determine the pressure range rows and column for the longest run. Use Table 610.4 Always round up to the next vertical column of run of pipe to the remote outlet. Pressure range on Table 610.4 use: (cycle one) 30-45 psi 46–60 psi Over 60 psi Max allowable length column use: (cycle one) 40 60 80 100 150 200 250 300 400 500 600 700
Step 6. Size supply to meter and to building. Use Table 610.4 Read down to column until the minimum number of fixtures that were determined in Step 2 is found. Read Minimum Size Supply to Meter and to Building from far left column of table. Use: Meter size 3/4 Building Supply size 3/4 1 11/4 Use: Meter size 1 Building Supply size 1 11/4 11/2 2 Use: Meter size 1 1/2 Building Supply size 11/4 11/2 2 Use: Meter size 2 Building Supply size 11/2 2 2 ½
Step 7. Sizing branches.
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
13
Calculate branch demand WSFU for both the cold and hot water. Longest run to remote Outlet from Step 4 and the appropriate pressure rows, read down the column to the total WSFU for that branch. The far left column will show the minimum branch size. Note that the branch size does NOT need to be larger than the building service size. Branch 1: ______ (cold water WSFU) + _____ (hot water WSFU) =_____ total: _____” size
Branch 2: ______ (cold water WSFU) + _____ (hot water WSFU) =_____ total: _____” size
Branch 3: ______ (cold water WSFU) + _____ (hot water WSFU) =_____ total: _____” size
Branch 4: ______ (cold water WSFU) + _____ (hot water WSFU) =_____ total: _____” size
Step 8. Size supply ONLY to water heater. Size the pipe to Water Heater using Total Hot Water WSFU from Step 3. Total system hot water WSFU = ________ total: _______ “size
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
15
Quiz 2 – Studio Apartment
All W. C. – 1.6 Gravity feed
Min. Press. at meter – 48 psi
Highest outlet above meter – 8 ft.
Drawing NOT to Scale.
Pipe Section
Length
A 30 ft.
B 16 ft.
C 18 ft.
D 6 ft.
E 4 ft. F 18 ft.
G 12 ft.
H 15 ft.
I 10 ft.
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
16
Pipe Section
Length Pipe Section
Length
A 20 ft. I 15 ft.
B 10 ft. J 2 ft.
C 18 ft. K 10 ft.
D 15 ft. L 15 ft.
E 5 ft. M 5 ft. F 3 ft. N 15 ft.
G 20 ft. O 25 ft.
H 12 ft.
Quiz 3 – 1 Bedroom Small House
All W. C. – 1.6 Gravity feed
Min. Press. at meter – 40 psi
Highest outlet above meter – 10 ft.
Drawing NOT to Scale
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
17
Pipe Section
Length Pipe Section
Length
A 20 ft. K 8 ft.
B 10 ft. L 10 ft.
C 2 ft. M 8 ft.
D 3 ft. N 8 ft.
E 10 ft. O 10 ft. F 8 ft. P 10 ft.
G 3 ft. Q 8 ft.
H 18 ft. R 20 ft.
I 25 ft. S 12 ft.
J 5 ft. T 20 ft.
Quiz 4 – 2 Bedroom Town House 1.5 Bath
All W. C. – 1.6 Gravity feed
Min. Press. at meter – 43 psi
Highest outlet above meter – 10 ft.
Drawing NOT to Scale
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
18
Pipe Section
Length Pipe Section
Length
A 25 ft. M 10 ft.
B 10 ft. N 3 ft.
C 2 ft. O 10 ft.
D 5 ft. P 8 ft.
E 18 ft. Q 3 ft.
F 5 ft. R 15 ft.
G 3 ft. S 5 ft.
H 25 ft. T 18 ft.
I 25 ft. U 5 ft.
J 5 ft. V 8 ft.
K 3 ft. W 18 ft.
L 15 ft.
Quiz 5 – Rambler House 2 Bath
All W. C. – 1.6 Gravity feed
Min. Press. at meter – 52 psi
Highest outlet above meter – 10 ft.
Drawing NOT to Scale
2015 UPC Chapter 6 Water Systems Part 2 RV 10.24.16
19
Quiz 6 – 3 Bedroom House 2 Story 2.5 Bath
All W. C. – 1.6 Gravity feed
Min. Press. at meter – 78 psi
Highest outlet above meter – 25 ft.
Drawing NOT to Scale
Pipe Section
Length Pipe Section
Length Pipe Section
Length
A 50 ft. J 5 ft. S 3 ft.
B 10 ft. K 3 ft. T 25 ft.
C 2 ft. L 20 ft. U 5 ft.
D 15 ft. M 20 ft. V 20 ft.
E 25 ft. N 20 ft. W 5 ft.
F 5 ft. O 3 ft. X 10 ft.
G 3 ft. P 2 ft. Y 10 ft.
H 15 ft. Q 15 ft. Z 20 ft. I 35 ft. R 10 ft.