2014 Advanced Code Module for Electricians Florida Building Code 2014 Reviewing Electrical requirements in the Florida Building Code (2014) and comparing them with requirements in the National Electrical Code. This course satisfied the 1 hour of Advanced Building Code Module needed to renew your license in Florida. This course contains content and page questions. As you progress through the course you will read the content and questions will pop up periodically pertaining to that content which you need to answer in order to proceed. You will get 2 attempts and your answers will be scored and a grade will be issued at the end of the course. Your progress will be saved as you go so feel free to take a break whenever you need to. You can log back in and pick up where you left off at any time. If you have any questions please feel free to contact us directly at 888-632-2633.

Upload: others

Post on 27-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

2014 Advanced Code Module for Electricians Florida Building Code 2014

Reviewing Electrical requirements in the Florida Building Code (2014) and

comparing them with requirements in the National Electrical Code. This course satisfied the 1 hour of Advanced Building Code Module needed to renew your license in Florida. This course contains content and page questions. As you progress through the course you will read the content and questions will pop up periodically pertaining to that content which you need to answer in order to proceed. You will get 2 attempts and your answers will be scored and a grade will be issued at the end of the course. Your progress will be saved as you go so feel free to take a break whenever you need to. You can log back in and pick up where you left off at any time. If you have any questions please feel free to contact us directly at 888-632-2633.

Page 2: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 Introduction to the Florida Building Code Florida Building Code and Electrical Installations – Building

1. Chapter 1 - Administration

Page 3: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

The 2014 Revision to the FBC

Was adopted in November 2014 and goes into effect June 30, 2015. The 2014 Florida Building Code consists of 9 Volumes.

Page 4: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

FBC Administration – Chapter 1

Application Since it is a legal document it is adopted in its entirety statewide. Local municipalities may apply for a more stringent codes. Miami/Dade,

Broward, Pinellas, and Pasco have at this time. Enforcement

The 2011 NEC is the adopted electrical standard in the 2014 FBC

Page 5: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code – Section 102.4 “…..Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply.” This means the Florida Building Code overrides the NEC if there are additional requirements.

Page 6: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 – Energy Conservation Chapter 1 [CE] - Administration Chapter 4 [CE] – Residential Energy Efficiency

Page 7: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Why do we need an energy conservation code? Our national energy usage is now measured in Quadrillion Btu per year!

Total kwh = 890,056,837,900 Lighting = 240,315,346,233 x .10/kwh

Over $24 billion a year

Page 8: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

In Commercial Facilities…

Lighting is the largest consumer

Building electrical consumption can be reduced by up to 12% just by managing lighting loads.

Florida Energy Conservation code requires active management of lighting

loads in many applications.

Page 9: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

FBC – Energy Code The Energy Code has been split into two sections.*

Residential designated by [RE] before the section Chapter 4 is Residential Energy Efficiency

Commercial designated by [CE] before the section Chapter 4 is Commercial Energy Efficiency

*Many sections have similar titles and language so be careful as you search for code sections.

Page 10: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

FBC- Energy Code Review

[R/C]101.2 – Scope. The Energy Conservation Code applies to residential and commercial buildings.

It is a statewide uniform code that shall not be made more stringent or

lenient by local government. [R/C]101.3 – Intent. This code is intended to provide flexibility to permit the

use of innovative approaches and techniques to achieve the effective use of energy.

This means that just about any alteration, addition, renovation or repair will have to abide by the FBC-EC requirements, unless they qualify as one of the exemptions.

Page 11: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

FBC – Energy Code Review

[R/C]101.4 – Applicability. Where different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern.

Where there is a conflict between general requirements and a specific

requirement, the specific requirement shall govern.

Page 12: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Chapter 4 [RE] – Residential Energy Efficiency

Recessed Lighting

R402.4.4/C402.4.8

Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.

All recessed luminaires shall be IC-rated (insulation contact). All recessed luminaires shall be sealed with a gasket or caulk between the

housing and the interior wall or ceiling covering.

It is also required in Commercial C402.4.8

Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.

All recessed luminaires shall be IC-rated (insulation contact). All recessed luminaires shall be sealed with a gasket or caulk between the

housing and the interior wall or ceiling covering.

Page 13: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

R403.9.1 Pool & Spa Heaters

All pool and spa heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting.

R403.9.2 Time Switches

Time switches shall be installed on swimming pool heaters and pumps that

can automatically turn the heaters and pumps off and on according to a preset schedule.

Exceptions: Where public health standards require 24 hour operation; where

pumps are required to operate solar and waste heat recovery systems; or where pumps are powered from on-site renewable energy generation.

Page 14: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Section R404 Electrical Power and Lighting Systems (Mandatory)

404.1 Lighting Equipment. A minimum of 75% of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficiency lamps

Page 15: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Section R404 Electrical Power and Lighting Systems (Mandatory) High-Efficacy Lamps include –

Compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps, Or lamps with a minimum efficacy of:

60 lumens per watt for lamps over 40 watts, 50 lumens per watt for lamps over 15 watts to 40 watts, and 40 lumens per watt for lamps 15 watts or less.

Page 16: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Industry Examples: Compact Fluorescent

Pin Based Compact Fluorescents Triple or Quad Tube Multiple Wattages 18, 26, 32, and 42 watts Non Permanent, Self Ballasted Edison solutions available

Page 17: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Industry Examples: Linear Fluorescent

Linear Fluorescents High Efficacy T8 and T5 lamp sizes Common Wattages 32, 28, and 54 Economical & Widely available

Page 18: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Industry Examples: Metal Halide

High Wattage up

to 1500W High Efficacy No Instant-On No Dimming Long Life

Page 19: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Industry Examples:

Induction Lamps

Ultra Long Life Choice of Color Temperature High Reliability High Efficacy

Page 20: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Industry Examples: LED

Long Life Still maintains 70% light output at 50,000 hours Many different wattages Long warranties: 5-10 years

Page 21: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Commercial Energy Conservation

Section C405 – Electrical Power and Lighting Systems (Mandatory) C405.2 Lighting Controls

Lighting systems shall be provided with controls as follows: C405.2.1.1 Interior Lighting Controls. Each area enclosed by walls or

floor-to-ceiling partitions shall have at least one manual control for the lighting serving the area. The required Controls shall be located within the area served by the controls or be a remote switch that identifies the lights served and indicates their status.

Exception: 1.) Areas Designated as security or emergency areas that need to be

continuously lighted. 2.) Lighting in stairways or corridors that are elements of the means of

egress.

Page 22: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

C405.2 Lighting Controls C405.2.1.2 Light Reduction Controls Each area that is required to have manual controls shall also allow the occupant to reduce the connected lighting load in a reasonably uniform pattern by at least 50% by … Dual Switching fixtures, rows, lamps, or other approved method. Exception: Light Reduction controls need not be provided in the following areas and spaces: 1.) Areas that have only one luminaire, with rated power less than 100 watts. 2.) Areas that are controlled by an occupant-sensing device. 3.) Corridors, equipment rooms, storerooms, restrooms, public lobbies, electrical or mechanical rooms. *See this section for other exceptions.

Additional Requirements

While these represent some of the changes there are many other application specific changes that affect almost every lighting installation. Reference the 2014 Florida Energy Conservation Code for more details.

Page 23: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

C405.2.2 Additional Lighting controls

C405.2.2.2 Occupancy Sensors shall be installed in: All classrooms Conference/Meeting Rooms Employee Break Rooms Private offices Restrooms Storage Closets Other spaces 300 ft2 or less

C405.2.2.2 Occupancy Sensors

Shall be installed to turn lighting off within 30 minutes of all occupants leaving a space, and

Shall be either manual on or shall be controlled to automatically turn the lighting on to not more than 50 percent power.

Occupancy Sensor Time Clock

Page 24: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

C405.2.4 Exterior Lighting Controls Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination photo sensor and a time switch* or an astronomical time switch*.

Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch* or photo sensor.

*All time switches must be capable of retaining settings for 10 hours during power loss.

Page 25: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 – Building

Chapter 27 - Electrical Chapter 7 – Fire and Smoke Protection Features Chapter 9 – Fire Protection Systems

Page 26: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 - Building

Chapter 27 - Electrical Adopts NFPA 70 (The National Electrical Code) In Florida, NFPA 70-2011 was adopted in November of 2014. NEC adoption will always lag behind it’s publication date because FL

Bldg Code is revised 1 year ahead of NEC Releases.

Page 27: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Chapter 7 – Fire and Smoke Protection Features

Section 703.7 – Marking and Identification of Fire /Smoke Barriers

Fire walls, fire barriers, fire partitions, smoke barriers, smoke partitions or any other wall required to have protected openings or penetrations shall be permanently identified with signs or stenciling.

Page 28: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Such identification shall:

1. Be located in accessible concealed floor, floor-ceiling, attic spaces. 2. Be marked within 15’ of the end of each wall and at intervals not

exceeding 30’ measured horizontally along the wall or partition; and

Page 29: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

3. Include lettering not less than 3” in height and with a minimum of 3/8” stroke.

Page 30: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Section 714 – Penetrations of Fire/Smoke Barriers

714.3.1 – Through penetrations of fire-resistance-rated walls shall comply with Section 714.3.1.1 or 714.3.1.2

To ensure the safety of building occupants during a fire precautions

must be taken to prevent the spread of fire and smoke. NFPA 70 also covers this in rule 300.21

Page 31: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

714.3.1.2 Through Penetration Fire Stop System

Through penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E 814 or UL 1479

Page 32: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Chapter 9 – Fire Protection Systems

907.2.11.3 – Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm.

907.2.11.4 – In new construction the master or host device “shall

receive it’s primary power from a commercial source” the guest devices may be battery powered per UL 217

Page 33: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 – Residential

Florida Building Code – Residential Local Amendments to the FBC

Page 34: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Florida Building Code 2014 – Residential

R314.4 Alterations, Repairs, and Additions 314.4 Has similar language as 907.2.11 but has the following exception 3. One-family and two family dwellings and townhomes undergoing a

repair or a Level 1 alteration as defined in the Florida Building Code, may use smoke alarms powered by 10-year nonremovable, nonreplaceable batteries in lieu of retrofitting such dwelling with smoke alarms powered by the dwellings electrical system.

Page 35: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

Local Amendments to the Florida Building Code

Local municipalities such as Miami/Dade, Broward, Pinellas, and Pasco have applied for modifications and been approved.

Subscribe to your county or city newsletter. Engage your inspectors in discussion of local changes Visit https://www.floridabuilding.org

Page 36: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

2014 Advanced Code Module Course for Electricians – Online Course Questions 45-1-1 Introduction to the Florida Building Code (1) The 2014 Revision to the FBC goes into effect _____. (a) May 30, 2015 (b) June 1, 2015 (c) June 15, 2015 (d) June 30, 2015 (1) The FBC is _____ volumes. (a) five (b) seven (c) nine (d) twelve Florida Building Code – Building Chapter 1 - Administration (2) The _____ NEC is the adopted electrical standard in the 2014 FBC. (a) 2005 (b) 2008 (c) 2011 (d) 2014 (3) The Florida Building Code overrides the NEC (a) True (b) False 45-2-1 Florida Building Code - Energy Conservation Chapter 1 - Administration (2) _____ is the largest energy consumer in commercial facilities. (a) space heating (b) office equipment (c) lighting (d) water heating (4) This Code is a statewide Code and shall not be made more stringent or lenient by local government. (a) True (b) False (5) Where there is a conflict between general requirements and a specific requirement, the general requirement shall govern.

Page 37: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

(a) True (b) False Chapter 4 - Residential Energy Conservation (6) Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between _____ spaces. (a) conditioned (b) unconditioned (c) conditioned or unconditioned (d) none of these (7) Time switches shall be installed on swimming pool heaters and pumps that can automatically turn the heaters and pumps off and on according to a preset schedule except _____. (a) where standards require 24 hour operation (b) where pumps are required to operate solar and waste heat recovery systems (c) where pumps are powered from on-site renewable energy generation (d) any of these (8) A minimum of _____ of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps. (a) 10% (b) 20% (c) 30% (d) 50% (9) High-efficacy lamps include compact fluorescent lamps, T-8 or smaller diameter linear fluorescent lamps, lamps with a minimum efficacy of 60 lumens per watt for lamps over _____ watts. (a) 15 (b) 20 (c) 40 (d) 60 (11) A common wattage for a linear fluorescent bulb is _____. (a) 32 (b) 28 (c) 54 (d) all of these (12) Metal halide bulbs are _____. (a) high wattage up to 1500W (b) high efficacy (c) long lasting (d) all of these (13) Induction lamps are _____. (a) short lasting (b) low reliability

Page 38: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

(c) low efficacy (d) none of these Commercial Energy Conservation (15) A manual control device shall be installed in any area enclosed by walls or floor-to-ceiling partitions except areas designated as security or emergency areas that need to be continuously lighted. (a) True (b) False (16) Each area that is required to have manual controls shall also allow the occupant to reduce the connected lighting load in a reasonably uniform pattern by at least _____ by dual switching fixtures, rows, lamps, or other approved method. (a) 15% (b) 25% (c) 50% (d) 75% (17) All time switches must be capable of retaining settings for _____ hours during power loss. (a) 8 (b) 10 (c) 12 (d) 24 (18) Lighting Florida Building Code 2014, Building 45-3-1 Chapter 27- Electrical (1) In Florida, NFPA 70-2011 was adopted in _____ 2014. (a) September (b) October (c) November (d) December (1) NEC adoption will always lag behind its publication date because FL Bldg. Code is revised _____ ahead of NEC Releases. (a) 6 months (b) 1 year (c) 2 years (d) 3 years Chapter 7 – Fire and Smoke Protection Features (2) _____ are required to have protected openings or penetrations shall be permanently identified with signs or stenciling. (a) Fire walls

Page 39: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

(b) Fire barriers (c) Smoke barriers (d) All of these (3) Fire and Smoke protection identification shall be marked within _____ of the end of each wall and at intervals not exceeding 30’ measured horizontally along the wall or partition. (a) 10’ (b) 12’ (c) 15’ (d) 30’ (4) Fire and Smoke protection identification shall include lettering not less than _____ in height and with a minimum of 3/8” stroke. (a) 2” (b) 3” (c) 4” (d) 5” (5) Openings into or through fire-rated assemblies must be firestopped using approved methods to maintain the fire-resistance rating. (a) True (b) False Chapter 9 – Fire Protection Systems (7) Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. (a) True (b) False 45-4-1 Florida Building Code 2014, Residential (1) One-family and two family dwellings and townhomes undergoing a repair or a Level 1 alteration as defined in the FBC, may use smoke alarms powered by _____ year nonremovable, nonreplaceable batteries in lieu of retrofitting such dwelling with smoke alarms powered by the dwellings electrical system. (a) 2 (b) 3 (c) 5 (d) 10 Local Amendments to the Florida Building Code

(2) Local municipalities _____ have applied for modifications and been approved. (a) Miami/Dade (b) Broward (c) Pasco

Page 40: 2014 Advanced Code Module for Electricians Florida ... · Chapter 7 – Fire and Smoke Protection Features Section 703.7 – Marking and Identification of Fire /Smoke Barriers Fire

(d) all of these