ANALYSIS OF FIELD RETURN SET
Applicable Model : VAL254/VAL294
![Page 2: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/2.jpg)
ANALYSIS OF FIELD RETURN SET : FACTORY END
![Page 3: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/3.jpg)
ANALYSIS OF FIELD RETURN SET : FACTORY END
![Page 4: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/4.jpg)
ANALYSIS OF FIELD RETURN SET : FACTORY END
![Page 5: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/5.jpg)
ANALYSIS OF FIELD RETURN SET : FACTORY END
![Page 6: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/6.jpg)
ANALYSIS PROCESS TO BE FOLLWED AT FIELD
1. Applicable for 245 Ltr & 285 Ltr model of KAS factory2. Model start with VAL254,VAL294,KSL254,KSL294.3. Applicable for Less cooling / No cooling problem4. Check the side wall heating taking place or not.5. If yes then follow the basic gas charging process / other repair process6. If No then check the ports Back cond outlet, Side cond inlet, Side cond outlet, front
inlet are connected properly or not.7. If yes then follow the basic gas charging process / other repair process8. Identification for “Back out let” :
a) Debraze the cond inlet + compressor jointb) Debraze all the U trap jointsc) Put pressure from cond outlet & check the removal near U trap location.d) The tube from where the pressure is coming out will be the “Cond Back Outlet”.
9. Identification for “Front inlet” :a) Debraze the Cond outlet + Dryer jointb) Put pressure from Cond outlet & check the removal near U trap location.c) The tube from where the pressure is coming out will be the “Front inlet”.
10. Now make the connection properly11. Follow the gas charging process12. Check for final observation.
![Page 7: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/7.jpg)
ANALYSIS PROCESS TO BE FOLLWED AT FIELD
Side wall heating (Door Hinge side of
ref)
NO
YES
No Cooling / Less Cooling problem
Applicable model : 245 Ltr & 285 LtrApplicable factory : KAS
Follow the basic process for gas leakage case / other problem
Check “cond back out”, “cond side in”, “cond side out” &
“front in” connection
YESFollow the basic process for gas
leakage case / other problem
NO
Identify the ports properly & reconnect
Follow Gas charging process Check for result
![Page 8: 1.Applicable for 245 Ltr & 285 Ltr model of KAS factory 2.Model start with VAL254,VAL294,KSL254,KSL294. 3.Applicable for Less cooling / No cooling](https://reader038.vdocuments.us/reader038/viewer/2022100423/5a4d1b5d7f8b9ab0599abb08/html5/thumbnails/8.jpg)
THANKS