1655 cuspidor - summitdental.com · 2020. 6. 2. · summit dental systems toll free: (800) 275-3368...

24
Summit Dental Systems Toll Free: (800) 275-3368 www.summitdental.com Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17 1655 Cuspidor

Upload: others

Post on 06-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 1 of 24

Installation

Operation

Maintenance

Troubleshooting

Version Dec/17

1655 Cuspidor

Page 2: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 2 of 24

Table of Contents

Important Information ............................................................................................................................ 4

Weight & Dimensions ........................................................................................................................... 6

Operator’s Instructions ......................................................................................................................... 7

Cleaning Your Cuspidor ....................................................................................................................... 8

Post Leveling.......................................................................................................................................... 9

Installation Instructions ....................................................................................................................... 10

Troubleshooting Guide ....................................................................................................................... 19

Parts List ............................................................................................................................................... 20

WARRANTY ......................................................................................................................................... 23

Page 3: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 3 of 24

Congratulations!

All of us at Summit Dental Systems want you to know that your 1655

Palm Beach Cuspidor has been built with the finest materials available.

The assembly and testing was completed by technicians devoted to making

SDS products perform to all prescribed specifications.

Our five year limited warranty is just one of the ways we express our

confidence that you will be completely satisfied with your purchase.

We appreciate your support and look forward to meeting your future

professional needs through our expanding product line.

Cesar Coral President

Page 4: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 4 of 24

Important Information

Technical Specifications Factory Pre-set Air Regulator Pressure: 80 PSI

Factory Pre-set Water Regulator Pressure: 40 PSI

Handpiece Pressure: 30-35 PSI (for most high-speed handpieces)

40-45 PSI (for most low-speed handpieces) Unpacking

Pay careful attention when unpacking the cuspidor and its accessories. Damage

caused by mishandling the equipment during unpacking or installation is not

covered under warranty.

New Owner

Please read, sign and submit the warranty registration form that is located at the

end of this manual. Failure to return this form may void the warranty.

Serial Number

Record this serial number in a convenient location. You will be

asked for this number when requesting service or warranty

information. (see drawing on next page for location of label).

Warning

SUMMIT DENTAL SYSTEMS Ft, Lauderdale, FL USA

MODEL No: SERIAL No: PRODUCT: VOLTS HERTZ AMPS

Medical Electrical Equipment needs special precautions regarding EMC and

needs to be installed and put into service according to the EMC information

provided in this manual. Portable and mobile RF communications equipment can affect Medical

Electrical Equipment.

Attention Manufacturer and

Serial Number

CE-mark Date of manufacture

Attention, consult

accompanying operation

instructions.

Page 5: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 5 of 24

European Authorized Representative

MT Promedt Consulting GmbH Altenhofstrasse 80 D-66386 St. Ingbert, Germany Phone: +49 (0)6894-581020 Fax: +49 (0)6894-581021

Questions? Read this manual carefully. If you have any questions, please call Summit Dental

Systems Technical Service at 1-800.275.3368 (USA) or (954) 730-3636 (Outside

USA).

CAUTION

! When adjusting the bowl rinse or cup fill flow control valves, do not over tighten the screws. This may result in unnecessary damage to the tubing.

CAUTION

Do not attempt to over extend the breakaway assembly. Over extension to the

! breakaway assembly may cause unnecessary damage to the cuspidor.

SUMMIT DENTAL SYSTEMS Ft, Lauderdale, FL USA

MODEL No: SERIAL No: PRODUCT:

VOLTS HERTZ AMPS

Product Label

Location

The product label can be located

behind the post mounted utility

box cover.

Page 6: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 6 of 24

Weight & Dimensions

Shipping Information

13”/330.2mm

23.5”/596.9mm

39”/990.6mm

Shipping Weight:

54 lbs/24.49mm

General Dimensions

6.11” 8.89”

155.2mm 225.7mm

35.27” / 896mm

Page 7: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 7 of 24

Operator’s Instructions

A. Automatic Cup Fill Control

B. Timed Bowl Rinse

C. Solids Collector D. City/Bottle Switch E. Water Bottle Switch F. Air Quick Disconnect G. Water Quick Disconnect H. Cup Fill Level Control I. Bowl Rinse Time Control J. Bowl Rinse Pressure Control H. Cup Fill Pressure Control

• Press and release cup fill button. The Cup Fill will automatically turn

off • Press and release bowl rinse button. The Bowl Rinse will

automatically turn off • Move cuspidor to access collection screen for disposal • Alternate from city or bottled water • Pressurizes the self-contained water bottle system • Air supply to accessories • Water supply to accessories • Adjusts the water level in the cup fill. • Adjusts the amount of time water flow in the bowl rinse. • Pinch valve on tubing. Controls amount of pressure at rinse nozzle. • Pinch valve on tubing. Controls water pressure from cup filler spout

Page 8: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 8 of 24

Cleaning Your Cuspidor

Daily Maintenance

At the end of every day.

1. Remove bowl screen from the cuspidor bowl and clean or discard (bio-hazard). 2. Raise the chair to its highest position and activate the bowl rinse several times, long

enough for the water to flow down the drain for approximately 60 seconds.

3. This will help prevent clogs in the drain line.

CAUTION

! Do not empty the bowl screen into the cuspidor. This can clog the cuspidor drain.

3. Remove the solids collector screen and discard.

CAUTION

! Bio-Hazard – use gloves mask and goggles.

4. Your cuspidor is designed for quick and easy cleaning. The smooth surfaces,

removable porcelain bowl and contoured spouts help facilitate more complete

cleaning.

Contoured Spouts

Bowl Screen Porcelain Bowl

Solids Collector

Page 9: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 9 of 24

Post Leveling

1. Install the post with the bushing at the top; be certain that the post bottoms in the

post socket ad that the hole in the side of the post is facing toward the head of the

chair. Look at the post socket and locate the eight leveling screws (see figure above). 2. Place a 6 to 12 inch level in the upright post (a magnetic level works best). While

holding the post as upright as possible, tighten the upper four leveling screws until

they just contact the post on all four sides. Position the level so that it is in line with

the front to back level screws.

3. Level the post front to back. Now move the level 90 degrees and repeat the above

procedure with the remaining screws for leveling side to side. Re-check level in both

directions, and then fully tighten all leveling screws.

4. To ensure that the unit is absolutely level, it will be necessary to level the base

unit on the post once the post has been leveled.

Page 10: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 10 of 24

Installation Instructions

Cup Fill & Bowl Rinse Spouts

Stop Pin

5o Clock Porcelain Bowl

Solids Canister

HVE & SE Hangers

6

o Clock

12o Clock

Drain Channel

Assembly 4 - ¼” Socket Set

Cover

4 ¼”

1. Lay cuspidor down on soft surface to prevent scratching outer cover. 2. Remove magnetic cover to expose mounting screws. 3. Insert light post into center hole of cuspidor until 4 ¼” of post protrudes out from bottom of

cuspidor.

Page 11: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 11 of 24

4. Tighten the two lowest ¼” socket head screws making sure that the stop pin is at 5o clock position

when cuspidor is at 12+6o clock position when mounted on chair. This position will stop the

horizontal arm of the Palm Beach light at 6o clock.

5. Lift the entire assembly and put light post bottom into chair mounting bracket and level. 6. Once level, adjust the cuspidor to the desired height and tighten all 4 socket head screws. 7. Attach the porcelain bowl to the bowl socket by slowly pressing down. This will allow the

cuspidor to properly set in the bowl socket. 8. Coat O-ring on cup fill and bowl flush spouts with O-ring lube before inserting them into their

respective sockets. If these spouts are removed for periodic cleaning, re-coat with O-ring lube as

necessary. 9. Insert the Cup Fill & Bowl Spouts in to their respected sockets, with the rubber gray seals

underneath the bowl and flush against the sockets.

10. Attach the HVE and Saliva Ejector tubing in their corresponding sockets of the solids canister

and place valves in hangers.

Adjust Bowls Rinse Water Flow 1. Test water flow around bowl 2. If needed put small round instrument in hole and rotate to get

desired water flow around bow.

Page 12: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 12 of 24

Test Bowl Rinse

1. Activate bowl rinse. 2. If bowl does not rinse long enough adjust 3-way bleed valve clockwise 3. If rinses to short turn 3-way bleed valve counter-clockwise

Test Cup Fill 1. Activate cup fill. 2. If bowl does not fill enough adjust 3-way bleed valve clockwise 3. If cup fills too much turn 3-way bleed valve counter-clockwise

Page 13: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 13 of 24

Junction Box Plumbing Layout Not to Scale

Page 14: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 14 of 24

Cuspidor Umbilical Connections

ƒ White 1/8” - spare

ƒ Red 1/8” – from air filter housing to in port on master switch ƒ Yellow 1/8” – signal air from master switch to air operated solenoids in Junction

Box

ƒ Orange 1/4” – drive air to unit ƒ Blue ¼” C – regulated and filtered water supply to cup filler relay valve in cuspidor

ƒ Blue ¼” B – regulated non-filtered water to bowl flush solenoid in cuspidor ƒ Clear

Blue 1/8” – to city water toggle valve in cuspidor

Post Mount Unit and Cuspidor Utility Box Connections

FROM PALM BEACH UNIT ARM

ƒ 1/8” red – master valve ƒ 1/8”

yellow – pilot air to unit ƒ 1/4”

orange – drive air

ƒ 1/8” pink – bio filter air, purge, syringe

ƒ 1/8” blue – water to unit ƒ 1/8” orange – air coolant

ƒ 1/8” green – purge ƒ 1/8” clear – handpiece valves, remote bowl and cup fill valves, biofilter

ƒ 1/8” white – spare

Junction Box Connections for Post Mount Unit

ƒ 1/8” red to master ƒ 1/8” yellow pilot air to unit

ƒ ¼” orange drive air to unit

ƒ ¼” gray foot control inlet

ƒ 1/8” blue water to unit ƒ ¼”

blue water to cuspidor ƒ 1/8”

green purge

Foot Control Connections

1/4” Orange Drive air out

1/4” Gray Drive air in

Page 15: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 15 of 24

Umbilical Entering Tray Head

Page 16: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 16 of 24

Utility Center Tubing Diagram Post and Swing Mounted Unit

Water and Air Regulator Assembly

Description Part # Wet & Dry Ft Ctrl 5-020-0058 Tubing, Sand 4H 5-070-0025 Water Regulator 5-070-0103 Filter Shut-Off Block 5-070-0102 Air Regulator 5-070-0111 ¼” Gray Tubing 5-070-0040

Description Part # ¼” Blue Tubing 5-070-0049 1/8” Blue Tubing 5-070-0028 1/8” Red Tubing 5-070-0027 ¼” Orange Tubing 5-070-0047 1/8” Green Tubing 5-070-0083 1/8” Yellow Tubing 5-070-0026

Page 17: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 17 of 24

Flow Diagram & Parts - Box Assembly

Page 18: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 18 of 24

Flow Diagram & Parts - Housing Assembly

Item Description Part # 1 Cup Fill Spout 5-030-3006

2 Bowl Rinse Spout 5-030-3004

3 Cusp. Bowl Housing 2-020-3035

4 Egg, Syringe Holder 5-020-3003

6 2-Way Push Button Valve - Bowl Flush 5-030-0054

7 2-Way Push Button Valve – Cup Filler 5-030-3000

Page 19: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 19 of 24

Troubleshooting Guide

SYMPTOM PROBABLE CAUSE

1. Water does not drain. A. Check drain for clogs or blockage.

2. Cup Fill and/or Bowl Rinse too slow. A. Adjust flow control valve. B. Kinked or pinched tubing. C. Check water pressure (40 PSI). D. Check water filter element in Junction Box

(cup fill only).

3. Cup Fill and/or Bowl Rinse too fast. A. Adjust flow control pinch valves.

B. Check water pressure (40 PSI).

4. No water flow. A. Kinked or pinched tubing.

B. Check for blockage at pinch valve location.

C. Replace element in water filter housing

(cup fill only).

5. Little to no suction. A. Replace suction solids screen under

cuspidor.

B. Check vacuum pump.

C. Kinked or pinched tubing.

Page 20: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 20 of 24

Parts List

Page 21: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 21 of 24

Cuspidor Assembly

Item Description Part # Item Description Part # 1 Post Mounted 2-030-3001 5 Cup Fill Spout 5-030-3006

Utility Center 6 Cup Fill Push 5-030-3007

2 Porcelain Bowl 2-020-3035 Button

3 Syringe Holder 5-020-3003 7 Bowl Rinse Push 5-030-3008

4 Bowl Rinse Spout 5-030-3004 Button

Page 22: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 22 of 24

Bowl Assembly 2-030-1000

Post Mounted Box Assembly 2-030-3001

Item Description Part # Item Description Part #

1 Water Bottle Valve 2-030-0019 8 Spacer 2-030-0020

2 Back Cover 2-020-3029 9 Top Cover 2-020-3030

3 Chassis 2-030-0014 10 Beauty Collar 2-030-0035

4 HP/Syringe Holder 5-020-3003 11 Beauty Collar 2-030-0026

5 Water Bottle Cap 5-020-0283 12 Screw ¼-20 x 3/8 5-030-0078

6 Front Cover 2-020-3028 13 Screw 10-32 x 5/8 5-030-0079

7 Water Bottle Cover 2-020-0068 14 Washer ¼ 4-010-0042

* Magnetic (on Cover) 4-020-0012

Page 23: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 23 of 24

WARRANTY

Summit Dental Systems (SDS) warrants its products against defects in materials or workmanship from the date of shipment to the Buyer as follows:

Summit Dental Systems (SDS) Equipment: Warranty Period: Chairs, Delivery Units, Cuspidors, Lights 5 Years Control Block Diaphragm (part of Delivery Unit) Lifetime All Upholstery, Stools, all Plastic Covers, and Cabinets 1 Year

Summit Dental Systems’ sole obligation under the warranty is to provide parts for repair, or at its option a replacement product (excluding all labor and shipping fees). “In any action, BUYER’S remedies are limited to warranty described above. BUYER shall not be permitted to claim lost profits, reliance, special, incidental, or consequential damages in any proceedings.”The warranty does not cover damage from improper installation or maintenance, accident or misuse. The warranty does not cover damage resulting from the use of cleaning disinfecting or sterilization chemicals and processes. Failure to follow instructions provided in Summit Dental Systems’ Operation and Installation Manuals (Owner’s Guides) may void the warranty. In the event Warranty service must be performed to correct any defect, only an authorized Summit Dental System dealer may perform any and all warranty repairs. Any repairs by unauthorized dealers, technicians, or repairmen may void the warranty.

• In the case of a defective warranty item, a copy of the replacement invoice, model and serial number of the product under which it was replaced, and a description of symptoms of the defect must be returned with the part within 30 days of the replacement invoice date to Summit Dental Systems, 1280 SW 27th Ave Pompano Beach, FL 33069, USA, in order to receive credit. Any and all expenses for freight, labor to perform warranty service, and purchase of spare parts are the responsibility of the buyer. Any fraudulent claims made may void the warranty. Any additional warranty that may be provided by an authorized Summit Dental Systems dealer is the sole responsibility of said dealer.

• SDS reserves the right to make changes or improvements on any products without being

required to modify existing equipment in a like manner.

Please complete and retain for your records the following Information:

In case of warranty part replacement/repair or when ordering a part, please call your authorized Summit Dental Systems dealer and have the following information available:

Owners’Name: Phone #: Model #: SDS Serial #:

Dealer: Phone:

Purchase Date:

Page 24: 1655 Cuspidor - summitdental.com · 2020. 6. 2. · Summit Dental Systems Toll Free: (800) 275-3368 Page 1 of 24 Installation Operation Maintenance Troubleshooting Version Dec/17

Summit Dental Systems

Toll Free: (800) 275-3368

www.summitdental.com

Page 24 of 24

1280 SW 27th Ave - Pompano Beach - FL 33069

Toll Free: (800) 275-3368

www.summitdental.com