16 inletfrom collector of hot liquid outlet technical step
TRANSCRIPT
with 2x vertical collectorsconnectedin the center
12Mounting
structures
21Shield
38Brass rein-
forcement
42Shield angle
connectors
527Steel Nut
Μ8
619Steel screw
Μ8χ12
74Plastic expansion
D10
84Hanger bolts
91Short inox hose
102Steel Washer
Μ8Χ24
111Brass elbow
3/4’’
121Long inox hose
148
172
Brass T with O-rings
184Rubber Gasket
20
21 22
2 Steel washer Μ8Χ16
Anti-freeze liquid
Brass plug with O-ring
17Step
18Step
19Step
16Step
20Step
8
1 4
121 91171 171181 181
3232
151131161 211
Support beams for2x collectors
Stud Μ8Χ20
A. First screw the studs on the movable metallic nuts on the lower side of the collector then apply the collector on the support structure and tight with washers and nuts. Β. First check that the front part of the solar system looks to the South and then pierce the floor.C. In case the collector has extra outlets, then you have to tap them, according to step 16.D. Check that you fullfill the closed circuit of the solar system with water and antifreeze liquid according to the instruc-tions indicated on the label of antifreeze liquid and then screw the expansion tank EMPTY and the pressure relief valve with use of teflon insulation.Ε. Check before leaving the installation site that all bolts are properly tightened and all piping are properly connected without leaking.
F. ATTENTION! The connection of the backup heating element must be done by experienced personnel.
11191
181121181
19
131Non-return
pressure valve
151Expansion
tank
161Pressure relief
valve
TechnicalManualFor the installation of a solar system
Inlet of hot liquid from collector
Outlet of cold liquid to collector
Screw it tight with the use of teflon insulation
Alternative position of the pressure-relief valve and the expansion tank in case of one tube on top of the tank. (instead of 2 tubes)
Regulator of backup heat-ing element to 60ο C
Screw it tight with the use of teflon insulation
34224
ATTENTION!See note C
232Mounting X
6252
6252
THIS SIDE OUT
2Step
5Step 64
54
62
1Step
3Step
61
232
51
4Step
6Step
7Step
9Step
N
S
E
SESW
W
χ χ
8Step
10Step
8474
11Step 52
42
62
12Step
6252
10221
13Step
14Step
6252
15Step
ATTENTION!See note A
64192
144
144
54
54
204
204
54
Move and place the mounting structures in the correct orientation and then align and center the collectors on the structures.
Press the center of the shield in order to curvature it like in step 14
example
2 items from object 6
Outlet of hot water for use
Inlet of cold water from water network
Backup heating elementInlet of hot
liquid from collector
Outlet of cold liquid to collector