116378093 ericsson msc commands

35
CDLCP © Telefonaktiebolaget LM Ericsson 2001 Call Duration Supervision, Long Duration Call, Print 1 Format 1.1 Command CDLCP; 1.2 Parameters This command has no parameters. 2 Function The command CDLCP initiates the printout LONG DURATION CALL SUPERVISION DATAthat lists the set-up data of the function time supervision and disconnection of long duration calls and whether automatic disconnection is initiated. The order does not remain after system restart. 3 Examples 3.1 Example 1 CDLCP; The command results in an answer printout being issued. 4 Printouts 4.1 Check Printout No.

Upload: raina-mimi

Post on 13-Apr-2015

524 views

Category:

Documents


44 download

TRANSCRIPT

Page 1: 116378093 Ericsson MSC Commands

CDLCP

© Telefonaktiebolaget LM Ericsson 2001

Call Duration Supervision, Long Duration Call, Print

1 Format

1.1 Command

CDLCP;

1.2 Parameters

This command has no parameters.

2 Function

The command CDLCP initiates the printout LONG DURATION CALL SUPERVISION DATAthat

lists the set-up data of the function time supervision and disconnection of long duration calls

and whether automatic disconnection is initiated.

The order does not remain after system restart.

3 Examples

3.1 Example 1

CDLCP;

The command results in an answer printout being issued.

4 Printouts

4.1 Check Printout

No.

Page 2: 116378093 Ericsson MSC Commands

4.2 Procedure Printouts

NOT ACCEPTED

fault type

Fault type:

FUNCTION BUSY

The function is busy.

FORMAT ERROR

The command or a parameter was incorrectly specified.

FAULT CODE 10 FUNCTIONALITY NOT SUPPORTED BY THIS EXCHANGE

The functionality addressed by the command is not supported by this exchange.

4.3 Answer Printouts

LONG DURATION CALL SUPERVISION DATA

4.4 Result Printouts

This command has no result printouts.

Page 3: 116378093 Ericsson MSC Commands

© Telefonaktiebolaget LM Ericsson 1998

Transmission Function Synchronous Digital Path, State, Print

1 Format

1.1 Command

/ \

|SDIP=sdip... |

TPSTP:[IO=io,]+ +;

|SDIP=ALL[,STATE=state...]|

\ /

1.2 Parameters

IO=io Input/Output (IO) device name

Identifier 1 - 7 characters

SDIP=sdip Synchronous Digital Path (SDIP) name

Identifier 1 - 7 characters ALL

All SDIPs

STATE=state State of SDIP BLOC

Blocked PBLOC

Partly blocked TRAFBLOC

Traffic blocked TRAFLIM

Traffic limited WO

Working

2 Function

This command prints the state of specified SDIP on specified or default IO device.

Printout SYNCHRONOUS DIGITAL PATH STATE is received.

Up to 10 SDIPs can be specified in each command.

The order does not remain after system restart.

Page 4: 116378093 Ericsson MSC Commands

3 Examples

3.1 Example 1

TPSTP:SDIP=LONDON;

The state of SDIP LONDON is printed.

3.2 Example 2

TPSTP:IO=AT-4,SDIP=LONDON&OSLO;

The state of the SDIPs LONDON and OSLO is printed on IO device AT-4.

3.3 Example 3

TPSTP:SDIP=ALL;

The state of all SDIPs is printed.

3.4 Example 4

TPSTP:IO=AT-4,SDIP=ALL,STATE=WO&BLOC;

All working and all blocked SDIPs are printed on IO device AT-4.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

ORDERED

NOT ACCEPTED

fault type

Fault type:

FUNCTION BUSY

Page 5: 116378093 Ericsson MSC Commands

The function is busy.

FORMAT ERROR

details

The command or a parameter was incorrectly specified.

UNREASONABLE VALUE

details

The parameter was specified with an unreasonable value.

FAULT CODE 2 SDIP DOES NOT EXIST

details

The specified SDIP does not exist.

FAULT CODE 3 ALL IS NOT ACCEPTED AS AN SDIP NAME

"ALL" is not accepted as a SDIP name.

FAULT CODE 4 NO SDIPS EXIST

No SDIPs exist.

FAULT CODE 5 TOO MANY SDIPS SPECIFIED

Too many SDIPs are specified.

4.3 Answer Printouts

SYNCHRONOUS DIGITAL PATH STATE

4.4 Result Printouts

SYNCHRONOUS DIGITAL PATH STATE

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0)

Page 6: 116378093 Ericsson MSC Commands

Telefonaktiebolaget LM Ericsson 2000

Transcoder Pool Resource Data, Print

1 Format

1.1 Command

/ \

|ALL |/ / \\

TKPRP:TRAPOOL=+ +|,DETAILS|,BLOC||;

|trapool...|\ \ //

\ /

1.2 Parameters

BLOC Blocked transcoder pool resources

Specifies that only the blocked transcoder resources belonging to the

transcoder pool are printed.

DETAILS Detail resources

Specifies that all the resources belonging to the transcoder pool are

printed.

TRAPOOL=trapool Transcoder pool

Identifier 1 - 7 characters

2 Function

This command initiates a printout of transcoder pool data for the specified transcoder pools.

The data is presented in the answer printout TRANSCODER POOL RESOURCE DATA. If

parameter DETAILS is specified in the command, all the transcoder resources connected to

the pool are printed with their resource state. If parameter BLOC is specified in the

command, only the blocked transcoder resources connected to the pool are printed.

The order does not remain after system restart.

3 Examples

3.1 Example 1

Page 7: 116378093 Ericsson MSC Commands

TKPRP:TRAPOOL=UAMR;

The transcoder pool data for the pool UAMR is printed.

3.2 Example 2

TKPRP:TRAPOOL=UAMR,DETAILS;

The transcoder pool data for the pool UAMR is printed. A list of all transcoder resources in

the pool is printed.

3.3 Example 3

TKPRP:TRAPOOL=UAMR,DETAILS,BLOC;

The transcoder pool data for the pool UAMR is printed. A list of all the transcoder devices in

the pool that are blocked is printed.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED

fault type

Fault type:

FUNCTION BUSY

The function is busy.

FORMAT ERROR

The command or a parameter was incorrectly specified.

UNREASONABLE VALUE

details

The parameter was specified with an unreasonable value.

FAULT CODE 4 TRANSCODER POOL NAME DOES NOT EXIST

details

The transcoder pool to be printed does not exist.

Page 8: 116378093 Ericsson MSC Commands

FAULT CODE 35 FUNCTIONALITY NOT SUPPORTED BY THIS EXCHANGE

Optional feature transcoder service not supported by this exchange.

4.3 Answer Printouts

TRANSCODER POOL RESOURCE DATA

4.4 Result Printouts

This command has no result printouts.

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0)

Page 9: 116378093 Ericsson MSC Commands

SQTLP

SERVICE QUALITY STATISTICS TIME LIMITS, PRINT

1 Format

1.1 Command

SQTLP;

1.2 Parameters

-

2 Function

The command requests printout of the time limits for

post-dialling delay,time to B-answer and conversation

time. These times are specified with command SQTLI.

The order does not remain after system restart.

3 Examples

3.1 Example

SQTLP;

The time limits for post-dialling delay,B-answer

and conversation time will be printed.

Page 10: 116378093 Ericsson MSC Commands

SQREP

SERVICE QUALITY STATISTICS RESULT, PRINT

1 Format

1.1 Command

/ / \\

| |DETAILED||

SQREP:MP=mp|,+ +|;

| |SURVEY ||

\ \ //

1.2 Parameters

DETAILED Detailed answer printout

MP=mp Measuring program identity (Numeral)

The number of measuring programs is size

alterable.

See Application Information for block SEQS3.

SURVEY Survey answer printout

2 Function

The command requests a printout of the current service

quality statistics which is received as an answer

printout. If there is no result output period in

progress the previous result output period results

will be printed.

The answer printout can be detailed or survey. If

the parameter DETAILED or SURVEY is omitted the answer

printout type will be survey. The detailed answer

printout shows all events. Time limits (PDD, BANSWER,

CTIME) which have not been specified are not shown.

The survey answer printout is presented in main groups,

and events that have not got any registrations will

not be included in this printout.

The results are presented in the printout SERVICE

QUALITY STATISTICS RESULT and the printout SERVICE

QUALITY STATISTICS RESULT SURVEY.

The order does not remain after system restart.

3 Examples

Page 11: 116378093 Ericsson MSC Commands

3.1 Example 1

SQREP:MP=6;

A subresult received as an answer printout is

requested for measuring program 6.

The answer printout type is survey.

3.2 Example 2

SQREP:MP=7,DETAILED;

A subresult received as an answer printout is

requested for measuring program 7.

The answer printout type is detailed.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED fault type

Fault type:

FORMAT ERROR

Format error

UNREASONABLE VALUE

details Unreasonable value

FAULT CODE 16

SPECIFIED MP IS NOT DEFINED FOR THE FUNCTION

The specified measuring program

is not defined for the function.

FAULT CODE 17

THE FIRST RECORDING PERIOD HAS NOT STARTED

The first recording period has

not started.

FAULT CODE 24

BUFFER FOR OUTPUT NOT AVAILABLE

Buffer for output is not available.

Give the command again.

Page 12: 116378093 Ericsson MSC Commands

4.3 Answer Printouts

SERVICE QUALITY STATISTICS RESULT

SERVICE QUALITY STATISTICS RESULT SURVEY

4.4 Result Printouts

-

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0).

7 Command Receiving Block

Page 13: 116378093 Ericsson MSC Commands

COMMAND DESCRIPTION 3/190 82-CNT 216

1205 Uen A1

SQMPP

SERVICE QUALITY STATISTICS MEASURING PROGRAM, PRINT

1 Format

1.1 Command

/ \

|mp...|

SQMPP:MP=+ +;

|ALL |

\ /

1.2 Parameters

mp Measuring program identity.

ALL All measuring

programs defined in the function.

2 Function

The command requests output of data for one or several

measuring programs and of the number of idle measuring

programs.

The order does not remain after system restart.

3 Examples

3.1 Example 1

SQMPP:MP=1&3;

Printout of measuring programs 1 and 3 is requested.

3.2 Example 2

Page 14: 116378093 Ericsson MSC Commands

SQMPP:MP=ALL;

Printout of all measuring programs is requested.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED fault type

Fault type:

FORMAT ERROR

Formal format fault in relation to the command description.

UNREASONABLE VALUE

details Unreasonable values, overaddressing.

FAULT CODE 16

details

The specified measuring program

is not defined for the function.

4.3 Answer Printouts

SERVICE QUALITY STATISTICS MEASURING PROGRAM

4.4 Result Printouts

-

5 Logging

No.

6 Command Category Group

Page 15: 116378093 Ericsson MSC Commands

Recommended value 0 (H' 0 ).

7 Command Receiving Block

SEQS2

COMMAND DESCRIPTION 2/190 82-CNT 216 1470 Uen B

SQESP

Service Quality Statistics Connection of End-of- Selection Codes, Print

1 Format

1.1 Command

/ \

|event...|

SQESP:EVENT=+ +;

|ALL |

\ /

1.2 Parameters

EVENT=event Event group

ALL All event groups

The following events are possible:

GROUP 1:

ARBDAD A-replacement

before, during or after dialling

Page 16: 116378093 Ericsson MSC Commands

BBUSY B-subscriber

busy

BNOEX B-number does

not exist

BOUT B-number out of

order

CONGGS Congestion in

group switch

CONGJT Congestion in

junctor terminals

CONGNW Congestion in

the network (that is, in the next

exchange)

CONGOT Congestion

in outgoing trunk (last choice route)

CONGTS Congestion in

time switch. (in the digital

subscriber switch)

EOSNOSE End-of

selection codes not connected to any

specified event group

FSIGCR Faulty signal

received in code receiver

FSIGCS Faulty

signal received in code sender

FSIGIT Faulty signal

received in incoming trunk

FSIGOT Faulty signal

received in outgoing trunk

HWFCR Hardware

fault in code receiver

HWFCS Hardware

fault in code sender

HWFJT Hardware fault

in junctor terminals

HWFIT Hardware fault

in incoming trunk

HWFOT Hardware fault

in outgoing trunk

Page 17: 116378093 Ericsson MSC Commands

HWFTS Hardware fault

in the time switch. (in the digital

subscriber switch)

NMBLO Calls blocked

due to Network Management actions

TOBDD Time out

before or during dialling

TOCS Time out in

code sender

TOOT Time out in

outgoing trunk

SPARE1 For own use

SPARE2 For own use

SPARE3 For own use

. .

. .

. .

SPARE16 For own use

GROUP 2:

RESHF Hardware fault

in speech position

RESSF Signalling

fault in speech position

2 Function

Command SQESP requests a printout of specified event

groups with the corresponding end-of-selection

codes.

The printout SERVICE QUALITY STATISTICS

END-OF-SELECTION CODES PER EVENT is received in

answer to this command.

The order does not remain after system restart.

3 Examples

3.1 Example 1

Page 18: 116378093 Ericsson MSC Commands

SQESP:EVENT=BBUSY&BOUT&BNOEX;

The corresponding end-of-selection codes will

be printed for the following event groups:

- B-subscriber busy

- B-number out of order

- B-number does not exist

3.2 Example 2

SQESP:EVENT=EOSNOSE;

The end-of-selection codes which are not

connected to any event group will be printed.

3.3 Example 3

SQESP:EVENT=ALL;

End-of-selection codes will be printed for all

event groups.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED fault type

Fault type:

FORMAT ERROR

Format error.

UNREASONABLE VALUE

details Unreasonable value.

FAULT CODE 26

EVENT CANNOT BE SPECIFIED WITH THIS APPLICATION SYSTEM

If the application parameter

HFANDSFALLOWED is not set, then

events RESHF and RESSF are not

allowed for the function.

Page 19: 116378093 Ericsson MSC Commands

4.3 Answer Printouts

SERVICE QUALITY STATISTICS END-OF-SELECTION CODES PER EVENT

4.4 Result Printouts

-

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0).

7 Command Receiving Block

SEQS1

Page 20: 116378093 Ericsson MSC Commands

COMMAND DESCRIPTION 2/190 82-CNT 216

1470 Uen B

SQESP

Service Quality Statistics Connection of End-of- Selection Codes, Print

1 Format

1.1 Command

/ \

|event...|

SQESP:EVENT=+ +;

|ALL |

\ /

1.2 Parameters

EVENT=event Event group

ALL All event groups

The following events are possible:

GROUP 1:

ARBDAD A-replacement

before, during or after dialling

BBUSY B-subscriber

busy

BNOEX B-number does

not exist

BOUT B-number out of

order

CONGGS Congestion in

group switch

CONGJT Congestion in

junctor terminals

CONGNW Congestion in

the network (that is, in the next

exchange)

Page 21: 116378093 Ericsson MSC Commands

CONGOT Congestion

in outgoing trunk (last choice route)

CONGTS Congestion in

time switch. (in the digital

subscriber switch)

EOSNOSE End-of

selection codes not connected to any

specified event group

FSIGCR Faulty signal

received in code receiver

FSIGCS Faulty

signal received in code sender

FSIGIT Faulty signal

received in incoming trunk

FSIGOT Faulty signal

received in outgoing trunk

HWFCR Hardware

fault in code receiver

HWFCS Hardware

fault in code sender

HWFJT Hardware fault

in junctor terminals

HWFIT Hardware fault

in incoming trunk

HWFOT Hardware fault

in outgoing trunk

HWFTS Hardware fault

in the time switch. (in the digital

subscriber switch)

NMBLO Calls blocked

due to Network Management actions

TOBDD Time out

before or during dialling

TOCS Time out in

code sender

TOOT Time out in

outgoing trunk

SPARE1 For own use

Page 22: 116378093 Ericsson MSC Commands

SPARE2 For own use

SPARE3 For own use

. .

. .

. .

SPARE16 For own use

GROUP 2:

RESHF Hardware fault

in speech position

RESSF Signalling

fault in speech position

2 Function

Command SQESP requests a printout of specified event

groups with the corresponding end-of-selection

codes.

The printout SERVICE QUALITY STATISTICS

END-OF-SELECTION CODES PER EVENT is received in

answer to this command.

The order does not remain after system restart.

3 Examples

3.1 Example 1

SQESP:EVENT=BBUSY&BOUT&BNOEX;

The corresponding end-of-selection codes will

be printed for the following event groups:

- B-subscriber busy

- B-number out of order

- B-number does not exist

3.2 Example 2

SQESP:EVENT=EOSNOSE;

The end-of-selection codes which are not

connected to any event group will be printed.

3.3 Example 3

Page 23: 116378093 Ericsson MSC Commands

SQESP:EVENT=ALL;

End-of-selection codes will be printed for all

event groups.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED fault type

Fault type:

FORMAT ERROR

Format error.

UNREASONABLE VALUE

details Unreasonable value.

FAULT CODE 26

EVENT CANNOT BE SPECIFIED WITH THIS APPLICATION SYSTEM

If the application parameter

HFANDSFALLOWED is not set, then

events RESHF and RESSF are not

allowed for the function.

4.3 Answer Printouts

SERVICE QUALITY STATISTICS END-OF-SELECTION CODES PER EVENT

4.4 Result Printouts

-

5 Logging

No.

6 Command Category Group

Page 24: 116378093 Ericsson MSC Commands

Recommended value 0 (H'0).

7 Command Receiving Block

SEQS1

COMMAND DESCRIPTION 6/190 82-CNT 298 0026 Uen B

NRGGP

© Telefonaktiebolaget LM Ericsson 2001

Network Resourcing, Media Gateway Group, Print

1 Format

1.1 Command

/ \

|mgg...|

NRGGP:MGG=+ +;

|ALL |

\ /

1.2 Parameters

MGG=mgg Media gateway group

Text string 1 - 7 characters ALL

All defined Media Gateway Groups (MGG)s.

Page 25: 116378093 Ericsson MSC Commands

2 Function

This command orders a printout with information about a specific or all the defined MGGs.

When parameter MGG is assigned with a name of a specific MGG, only data for the specified

MGG are printed. When it is assigned with the value ALL, data for all defined MGGs are

printed.

Answer printout MEDIA GATEWAY GROUP DATA is received.

The order does not remain after system restart.

3 Examples

3.1 Example 1

NRGGP:MGG="MGG4GBR"&"MGG3GR";

Information about media gateway groups "MGG4GBR" and "MGG3GR" are printed.

3.2 Example 2

NRGGP:MGG=ALL;

Information about all defined media gateway groups are printed.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED

fault type

Fault type:

FORMAT ERROR

The command or a parameter was incorrectly specified.

Page 26: 116378093 Ericsson MSC Commands

UNREASONABLE VALUE

details

The parameter was specified with an unreasonable value.

FAULT CODE 10 THE SPECIFIED MGG HAS NOT BEEN DEFINED

The specified MGG has not been defined.

FAULT CODE 14 FUNCTIONALITY NOT SUPPORTED BY THE APPLICATION

The functionality is not supported by the application.

FAULT CODE 26 FUNCTIONALITY NOT SUPPORTED BY THIS EXCHANGE

The functionality is not supported by this exchange.

4.3 Answer Printouts

MEDIA GATEWAY GROUP DATA

4.4 Result Printouts

This command has no result printouts.

5 Logging

No.

6 Command Category Group

Recommended value 00 (H'00)

7 Command Receiving Block

NRM

8 Glossary

MGG Media Gateway Group

9 References

Page 27: 116378093 Ericsson MSC Commands

9.1 Printout Descriptions

MEDIA GATEWAY GROUP DATA

COMMAND DESCRIPTION 3/190 82-CNT 238

0164 Uen A

HGSTP

© Telefonaktiebolaget LM Ericsson 1999

Home Location Register, Subscriber Tracing, Print

1 Format

1.1 Command

/ \

|imsi|

HGSTP:IMSI=+ +;

|ALL |

\ /

1.2 Parameters

IMSI=imsi International Mobile Subscriber Identity (IMSI)

See the Application Information for block HTRAN.

ALL

All IMSI with initiated trace data

2 Function

Page 28: 116378093 Ericsson MSC Commands

This command prints the trace data for mobile subscribers in Home Location Register (HLR).

Answer printout HLR SUBSCRIBER TRACING DATA is received.

This command can be initiated from up to 16 Input/Output (IO) devices simultaneously.

Only one command can be initiated when parameter ALL is specified.

The order does not remain after system restart.

3 Examples

3.1 Example 1

HGSTP:IMSI=ALL;

The trace data for all mobile subscribers, are printed.

3.2 Example 2

HGSTP:IMSI=1234567890;

The trace data for IMSI 1234567890 are printed.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED

fault type

Fault type:

FUNCTION BUSY

The function is busy.

FORMAT ERROR

The command or a parameter was incorrectly specified.

Page 29: 116378093 Ericsson MSC Commands

UNREASONABLE VALUE

details

The parameter was specified with an unreasonable value.

FAULT CODE 13 IMSI NOT DEFINED

The IMSI is not defined.

FAULT CODE 73 SUBSCRIBER DISCONNECTION IN PROGRESS

Disconnection in progress for that mobile subscriber.

FAULT CODE 75 FUNCTIONALITY NOT SUPPORTED BY THIS EXCHANGE

The functionality connected to the command is not supported by this exchange.

FAULT CODE 232 TRACE DATA NOT INITIATED FOR THIS IMSI

No trace data are initiated for the specified IMSI.

4.3 Answer Printouts

HLR SUBSCRIBER TRACING DATA

4.4 Result Printouts

This command has no result printouts.

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0)

7 Command Receiving Block

HSTRA

8 Glossary

Page 30: 116378093 Ericsson MSC Commands

HLR Home Location Register

IMSI International Mobile Subscriber Identity

IO Input/Output

9 References

9.1 Printout Descriptions

HLR SUBSCRIBER TRACING DATA

9.2 Application Information

HTRAN

COMMAND DESCRIPTION 2/190 82-CNT 238 0034 Uen D

HGSDP

© Telefonaktiebolaget LM Ericsson 2001

Home Location Register, Subscriber Data, Print

1 Format

Page 31: 116378093 Ericsson MSC Commands

1.1 Command

/ \

/ \ | / \ |

|MSISDN=msisdn...| | |ALL | |

| | | |SUDA| |

HGSDP:+IMSI=imsi... + |,+SSDA+ |;

| | | |LOC | |

|CONNECTED | | |PDP | |

\ / | \ / |

\ /

1.2 Parameters

ALL All subscriber data

CONNECTED All connected subscribers

IMSI=imsi International Mobile Subscriber Identity (IMSI)

See the Application Information for block HTRAN.

LOC Subscriber location data

MSISDN=msisdn Mobile Station ISDN Number (MSISDN)

See the Application Information for block HTRAN.

PDP Packet Data Protocol (PDP) context subscriber data

Application system dependant parameter.

SSDA Permanent and supplementary service subscriber data

SUDA Permanent subscriber data

2 Function

This command prints subscriber data for mobile subscribers in Home Location Register

(HLR).

Answer printout HLR SUBSCRIBER DATA is received.

Associated answer printouts are also received depending on the parameter given:

PERMANENT SUBSCRIBER DATA, SUPPLEMENTARY SERVICE DATA, LOCATION DATA

and PACKET DATA PROTOCOL CONTEXT DATA answer printouts are received when

parameter ALL is entered.

PERMANENT SUBSCRIBER DATA is received when parameter SUDA is entered.

PERMANENT SUBSCRIBER DATA and SUPPLEMENTARY SERVICE DATA answer

printouts are received when parameter SSDA is entered.

LOCATION DATA answer printout is received when parameter LOC is entered.

Page 32: 116378093 Ericsson MSC Commands

PACKET DATA PROTOCOL CONTEXT DATA answer printout is received when parameter PDP is entered.

This command can be initiated from up to 16 Input/Output (IO) devices simultaneously.

The order does not remain after system restart.

3 Examples

3.1 Example 1

HGSDP:CONNECTED;

Subscriber data for all connected subscribers are printed.

3.2 Example 2

HGSDP:IMSI=1234567890,ALL;

All subscriber data for the mobile subscriber with IMSI 1234567890 are printed.

3.3 Example 3

HGSDP:IMSI=1234567890,SUDA;

Permanent subscriber data for the mobile subscriber with IMSI 1234567890 are printed.

3.4 Example 4

HGSDP:MSISDN=3417429013,SSDA;

Permanent and supplementary service subscriber data for the mobile subscriber with

MSISDN 3417429013 are printed.

3.5 Example 5

HGSDP:MSISDN=3417429013,LOC;

Location data for the mobile subscriber with MSISDN 3417429013 are printed.

3.6 Example 6

HGSDP:CONNECTED,LOC;

Page 33: 116378093 Ericsson MSC Commands

Location data for all connected subscribers are printed.

3.7 Example 7

HGSDP:MSISDN=3417429013&3417429015,SSDA;

Permanent and supplementary service subscriber data for the mobile subscribers with

MSISDNs 3417429013 and 3417429015 are printed.

3.8 Example 8

HGSDP:IMSI=3417429013&3417429015,PDP;

PDP context data for the mobile subscribers with IMSIs 3417429013 and 3417429015 are

printed.

4 Printouts

4.1 Check Printout

No.

4.2 Procedure Printouts

NOT ACCEPTED

fault type

Fault type:

FUNCTION BUSY

The function is busy.

FORMAT ERROR

The command or a parameter was incorrectly specified.

UNREASONABLE VALUE

details

The parameter was specified with an unreasonable value.

FAULT CODE 183 PARAMETER NOT SUPPORTED BY THIS EXCHANGE

details

The parameter is not supported by this exchange.

Page 34: 116378093 Ericsson MSC Commands

4.3 Answer Printouts

HLR SUBSCRIBER DATA LOCATION DATA PACKET DATA PROTOCOL CONTEXT DATA PERMANENT SUBSCRIBER DATA SUPPLEMENTARY SERVICE DATA

4.4 Result Printouts

This command has no result printouts.

5 Logging

No.

6 Command Category Group

Recommended value 0 (H'0)

7 Command Receiving Block

HSDA

8 Glossary

HLR Home Location Register

IMSI International Mobile Subscriber Identity

IO Input/Output

MSISDN Mobile Station ISDN Number

PDP Packet Data Protocol

9 References

9.1 Printout Descriptions

HLR SUBSCRIBER DATA

LOCATION DATA

PACKET DATA PROTOCOL CONTEXT DATA

PERMANENT SUBSCRIBER DATA