1 pressure transmitter integrated open dcs positioner cv diagnostics azbil solutions for...
TRANSCRIPT
1
Pressure Transmitter
Integrated Open DCS Positioner
CV Diagnostics
“azbil” Solutions for Petrochemical Plant
Special
Control Valve
2
OperationAnywhere
DOPC
Ex Proof Field Client
Field Client PlantWalker-HV
AMCPM100PM-EX
DGFC DGPL
Integrated HMI
3rd party system
Knowledge PowerAlarm AnalystPREXION, Electric Shift LogUtility Optimization
Yamatake Solution Vision with Yamatake Solution Vision with System PlatformSystem Platform
azbil Open System Platform with a variety of Solution Packages
3
For Shift LeaderFor Manufacturing Stuff
For Manufacturing Manager
•Distill data in multiple sources into useful data
•Personalize useful data for each individual meeting their role and responsibility
HistoryQualityLabo
Plan/PerformanceSOP Asset DataShift Log Batch Order/Ship
MIB- For Manufacturing data visualization
• Personalized window presentation images…
4
Infrastructure of production
Information systemProcess historical information user can utilize the information at any time and any accuracy depending on their work.
TechnologyControl
QualityControl
FacilityManagement
ProductionControl
OperationManageme
nt
Site performancefor Plant Manager
Production performancefor Production Engineer
Process performancefor Shift Leader
PREXION – For production monitoring
5
Alarm Analyst - Correlation analysis
Correlation Analysis;-Easy to build Knowledge-Base alarm & event
model… unique technology
From alarm & event historical logs, Correlation Analysis extracts ;- Event groups consisted of the alarms and the operation
actions in a process upset Propagation path Source origin Nuisance alarms Total counts in Alarm & Event group Information about Alarm & Event group structure Cause & Effect relationship
– Cause of alarm flood or complex operation is estimated using order of events occurrence.
Alarm Analyst R20
6
Clogging of fluid in the body
Tank bottom charge valve Y-type slurry angle valve
High viscous fluids make clogging problems easily. No dead space and smooth flow through inside the valve body are required.
Example 1: PTA plant Example 2: Polypropylene plant
azbil Solution-oriented Control Valve
7
azbil Solution-oriented Control Valve
For detailed specification, please contact the sales representative in Azbil India.
8
SVP has diagnostic algorithm and parameter of control valve operating condition.<Diagnostic parameters> Stick Slip Total Stroke Max. Travel Speed Travel histogram Shut Count Cycle Count
Threshold for alarmThreshold for alarm
Valstaff: Diagnostics function of control valve
When the trend of these parameters are monitored…
Early detection of control valve abnormality
Establishment of control valve maintenance period
Customers can identify normality as the safety of the control valve.Customer can do predictive maintenance of control valve.
HMIApplication software Valstaff
Diagnosis algorithm
Smart Valve Postioner
<Diagnostic system>
9
AT9000(GTX): Impulse-line less instrumentation
Instrumentation with Impulse line
Impulse-line
Impulse-line less instrumentation
½ inches remote seal type transmitter
It enable to remove the Impulse-line with ½ inches remote seal type transmitter .
GTX solve the problem with Impulse-line like clogging, corrosion …etc.
You can significantly reduce the cost of field maintenance work!