1. outline of application control - carriertcb-ifmb640tle bms-lsv6e bacnet server lonworks bacnet...

11
SMMS-i Data book -1 10 10 Controls 1. Outline of application Control Side remote Master remote Schedule timer TCB-EXS21TLE Central remote controller TCB-SC642TLE2 Remote ON/OFF TCB IFCB-4E2 External master ON/OFF board TCB-PCMO2E Power peak-out control board TCB-PCDM2E Error output control board TCB-PCIN2E Batch drive, error output Master ON/OFF signal Error/operation output Master ON/OFF signal Power peak-out control signal “1:1 model” connection TCC-Link Interface TCB-PCNT30TLE2 Super Digital Inverter Digital Inverter SMMS SMMS-i Alarm Status output ON/OFF Command Mini-SMMS BMS-LSV4E BMS-IFLSV4UL(U.S.) TCS-Net Relay Interface Modbus (Master) BMS-LSV6E BACnet Server TCB-IFMB640TLE BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE BMS-TP0641PWE BMS-TP5121PWE Compliant Manager BMS-CM1280FTLE Compliant Manager BMS-CM1280TLE Wired remote controller with Weekly timer RBC-AMS41E Wired remote controller RBC-AMT32(31)E Simple remote controller RBC-AS21E2 Wireless remote controller Remote Sensor TCB-TC21LE2 BMS-WB01GTE Master Server Webserver BMS-WB2561PWE BMS-WB2561PWE Gateway BMS-WB2561PWE Gateway Sensors/switch/key/actuator .LonWorks Analog I/F(DCvoltage) TCB-IFLN642TLE/TCB-IFLN642UL TCB-IFCB640TLE Op Open System en System Daiseikai GSM REMOTE CONTROL I/F TCB-IFGSM1E GSM Modem Air-conditioning Management System TCC-LINK Intranet Energy monitoring Relay I/F BMS-IFWH5E BMS-IFWH5UL(U.S.) Digital I/O Relay I/F BMS-IFDD03E BMS-IFDDO3UL(U.S.) Power Meter I/O Device *Monitoring *Remote control *Schedule operation *Error code indication *Alarm list indication *Monthly report *Energy monitoring data etc. 1.LonWorks : Registered trademark by Echelon corporation. 2.BACnet : ANSI/ASHRAE 135-1995,A data Communication Protocol for Building Automation and Control Network. 3.Modbus : Registered trademark by Schneider E. Notes:Co-existence and interoperability of each product shall be referred to another documents. RS485 RS485 RS485 RS485 RS485 RS485 RS485 RS485 RS485 TCC-LINK TCC-LINK TCC-LINK TCC-LINK TCC-LINK ON-OFF controller TCB-CC163TLE2 Error output control board Compressor operation /system operation ratio(SMMS-i only) TCB-PCIN4E Compressor operation /system operation ratio(SMMS-i only) External sw TCB-KBOS1E for SDI4 only Cable for connector CN32(TCB-KBCN32VEE) CN60(TCB-KBCN60OPE) CN61(TCB-KBCN61HAE) CN70(TCB-KBCN70OAE) CN73(TCB-KBCN73DEE) CN80(TCB-KBCN80EXE) Cable for connector CN32(TCB-KBCN32VEE) CN60(TCB-KBCN60OPE) CN61(TCB-KBCN61HAE) CN70(TCB-KBCN70OAE) CN73(TCB-KBCN73DEE) CN80(TCB-KBCN80EXE) Energy monitoring Relay I/F Digital I/O Relay I/F Power Meter I/O Device Energy monitoring Relay I/F Digital I/O Relay I/F Energy monitoring Relay I/F Digital I/O Relay I/F TCC-LINK TP DC line Air-conditioning Management System on site

Upload: others

Post on 10-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

SMMS-i Data book

-110

10 Controls

1. Outline of application Control

S

ide

rem

ote

Mas

ter r

emot

e

Sch

edul

e

timer

TC

B-E

XS

21TL

E

Cen

tral r

emot

e co

ntro

ller

TCB

-SC

642T

LE2

R

emot

e O

N/O

FF

TC

B IF

CB

-4E

2

E

xter

nal m

aste

r ON

/OFF

boa

rd

TCB

-PC

MO

2E

Pow

er p

eak-

out c

ontro

l bo

ard

TCB

-PC

DM

2E

Err

or o

utpu

t con

trol b

oard

TC

B-P

CIN

2E

Bat

ch d

rive,

err

or o

utpu

t

Mas

ter O

N/O

FF s

igna

l

Err

or/o

pera

tion

outp

ut

Mas

ter O

N/O

FF s

igna

l P

ower

pea

k-ou

t con

trol s

igna

l

“1:1

mod

el” c

onne

ctio

n

TCC

-Lin

k In

terfa

ce

TCB

-PC

NT3

0TLE

2

Sup

er D

igita

l Inv

erte

r

Dig

ital I

nver

ter

SM

MS

S

MM

S-i

Ala

rm S

tatu

s ou

tput

ON

/OFF

C

omm

and

Min

i-SM

MS

BM

S-L

SV

4E

BM

S-IF

LSV

4UL(

U.S

.)

TCS

-Net

Rel

ay In

terfa

ce

Mod

bus

(M

aste

r)

BM

S-L

SV

6E

BA

Cne

t Ser

ver

TCB

-IFM

B64

0TLE

BA

Cne

t

LON

WO

RK

S

Gen

eral

Pur

pose

I/F

TCB

-IFC

G1T

LE

Touc

h-sc

reen

Con

trolle

r B

MS

-TP

0641

AC

E

BM

S-T

P51

21A

CE

B

MS

-TP

0641

PW

E

BM

S-T

P51

21P

WE

Com

plia

nt M

anag

er

BMS-

CM

1280

FTLE

C

ompl

iant

Man

ager

B

MS-

CM

1280

TLE

Wire

d re

mot

e co

ntro

ller

with

Wee

kly

timer

R

BC

-AM

S41

E

Wire

d r

emot

e co

ntro

ller

RB

C-A

MT3

2(31

)E

Sim

ple

rem

ote

cont

rolle

r R

BC

-AS

21E

2

Wire

less

rem

ote

cont

rolle

r

Rem

ote

Sen

sor

TCB

-TC

21LE

2

BM

S-W

B01

GTE

Mas

ter S

erve

r

Web

serv

er

BM

S-W

B25

61P

WE

BM

S-W

B25

61P

WE

Gat

eway

BM

S-W

B25

61P

WE

Gat

eway

Sen

sors

/sw

itch/

key/

actu

ator

.Lon

Wor

ks

Ana

log

I/F(D

Cvo

ltage

)

TCB

-IFLN

642T

LE/T

CB

-IFLN

642U

L

TCB

-IFC

B64

0TLE

Op

Ope

n Sy

stem

en

Sys

tem

Dai

seik

ai

GSM

REMO

TE C

ONTR

OL I/F

TCB

-IFG

SM

1E

GS

M M

odem

Air-c

ondi

tioni

ng M

anag

emen

t

Sys

tem

TCC

-LIN

K

Intra

net

Ene

rgy

mon

itorin

g R

elay

I/F

BM

S-IF

WH

5E

BM

S-IF

WH

5UL(

U.S

.)

Dig

ital I

/O

Rel

ay I/

F B

MS

-IFD

D03

E

BM

S-IF

DD

O3U

L(U

.S.)

Pow

er M

eter

I/O

Dev

ice

*Mon

itorin

g

*Rem

ote

cont

rol

*S

ched

ule

oper

atio

n

*Err

or c

ode

indi

catio

n

*Ala

rm li

st in

dica

tion

*M

onth

ly re

port

*E

nerg

y m

onito

ring

data

etc

.

1.Lo

nWor

ks: R

egis

tere

d tr

adem

ark

by E

chel

on c

orpo

ratio

n.2.

BA

Cne

t: A

NSI

/ASH

RA

E 1

35-1

995,

A da

ta C

omm

unic

atio

n Pr

otoc

ol fo

r B

uild

ing

Aut

omat

ion

and

Con

trol

Net

wor

k.

3.M

odbu

s: R

egis

tere

d tr

adem

ark

by S

chne

ider

E.

Not

es:C

o-ex

iste

nce

and

inte

rope

rabi

lity

of e

ach

prod

uct

shal

l be

re

ferr

ed

to

anot

her

docu

men

ts.

RS48

5

RS48

5 RS

485

RS48

5

RS48

5

RS48

5

RS48

5

RS48

5

RS48

5 TCC-

LIN

K

TCC-

LIN

K

TCC-

LIN

K

TCC-

LIN

K

TCC-

LIN

K

ON

-OFF

con

trol

ler

TCB-

CC16

3TLE

2

Err

or o

utpu

t con

trol b

oard

C

ompr

esso

r ope

ratio

n /s

yste

m o

pera

tion

ratio

(SM

MS

-i on

ly)

TCB

-PC

IN4E

Com

pres

sor o

pera

tion

/sys

tem

oper

atio

n ra

tio(S

MM

S-i

only

)

Ext

erna

l sw

TCB

-KB

OS1

E

for

SD

I4 o

nly

Cab

le fo

r co

nnec

tor

CN32

(TCB

-KBC

N32

VEE)

CN

60(T

CB-K

BCN

60O

PE)

CN61

(TCB

-KBC

N61

HAE

) CN

70(T

CB-K

BCN

70O

AE)

CN73

(TCB

-KBC

N73

DEE

) CN

80(T

CB-K

BCN

80EX

E)

Cab

le fo

r co

nnec

tor

CN32

(TCB

-KBC

N32

VEE)

CN

60(T

CB-K

BCN

60O

PE)

CN61

(TCB

-KBC

N61

HAE

) CN

70(T

CB-K

BCN

70O

AE)

CN73

(TCB

-KBC

N73

DEE

) CN

80(T

CB-K

BCN

80EX

E)

Ene

rgy

mon

itorin

g

Rel

ay

I/F

Dig

ital I

/O R

elay

I/F

Pow

er M

eter

I/O

Dev

ice

Ene

rgy

mon

itorin

g R

elay

I/F

D

igita

l I/O

Rel

ayI/F

Ene

rgy

mon

itorin

g R

elay

I/F

Dig

italI

/OR

elay

I/F

TCC-

LIN

K

TP

DC

lin

e

Air-

cond

ition

ing

Man

agem

ent S

yste

m o

n si

te

Page 2: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-210

2. Applications for indoor remote controller

Basic function System diagram Model

2-1

Individual controlAir conditioner is individually operated at a distance.

• Wired remote controllerRBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2

2-2

GROUP controlOne remote controller can control a group of up to a max. 8 indoor units. Operating on the same setting.

• Wired remote controllerRBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2

2-3

Two remote controlAir conditioner is controlled by two remote controllers in two locations.

• Wired remote controllerRBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2

2-4

Control by schedule timer

Schedule timer mode and Weekly timer mode

• Wired remote controllerRBC-AMT32ERBC-AMT31E

• Central remote controllerTCB-SC642TLE2

• Schedule timerTCB-EXS21TLE

(((

Main remote controller

Receiver unit

Wireless remote controller

Indoor unit

Remote controller

Wireless remote

controller

Indoor unit

Max.8 indoor units

Indoor unit

Indoor unit

Indoor unit

Indoor unit

Remote controller

(((

( ( (

( ( (

Wireless system

Wired system

Indoor unit

Indoor unit

Remote controller

Remote controller

Wireless remote

controller 1

Wireless remote

controller 2

Master Side

Master Side

Indoor unit

Wired & Wireless combination control(Either one of the two controllers can be set as side control.)

Remote controller

Wireless remote

controller

When two wireless remote controllers are operated at the same time, the communication are not done by interference of both infrared rays.

Indoor unit

Central remote

controller

Schedule timer

Weekly timer modeSchedule timer mode

Schedule timer

Wired remote

controller

Indoor unit

TCC-LINK

SW setting at schedule timer is necessary.

Page 3: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-310

3. Application control for central remote controller

Basic function System diagram Model

3-1Central management

controllers for 64/128 units Controller for 64 units(TCB-SC642TLE2)

• Individual control up to 64 indoor units• Individual control for max. 64 indoor units divided in to 4 zones

(Up to 16 indoor units for each zone)• Up to 16 outdoor header units are connectable.• Setting for one of 1 to 4 zones is available.

Controller for 128 units(BMS-CM1280TLE)• Individual control of up to (64 indoor units) 2 TCC-LINK buses• Individual control of up to (64 indoor units divided 1 to 64

zone) 2 TCC-LINK buses (Up to 64 indoor units for each zone)• Up to 16 outdoor header units are connectable per 1 TCC-LINK

bus• Setting for (one of 1 to 64 zones) 2ch is available.• Setting for (one of 1 to 64 groups) 2ch is available.• Return back setting

Common• 4 types central control settings to restrict individual operation by

remote controller are selectable.• Usable with other central control devices (Up to 10 central

control devices in one control circuit)• Two control mode selectively Contral controller mode/Remote

controller mode• Master/Sub setting possible

• Central remote controllerTCB-SC642TLE2BMS-CM1280TLE

Indoor remote controller• Wired remote controller

RBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kit

Outdoor unit

Indoor unitLine-3

U3, U4

U5, U6

U1, U2

Single phase 220V

Powersupply

Central remote controller

Outdoor unit

Outdoor unit

Indoor unit

Indoor unit

Indoor remote controller

Indoor remote controller

Indoor remote controller

Line-2

Line-1

U3, U4

U3, U4

Zone4

Zone3

Zone2

Zone1

U5, U6

U1, U2

Header unit

Header unit

U1, U2

Header unit

Function of central remote controller

Page 4: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-410

3-2

Central remote controller+

Schedule timerWeekly operation schedule can be set by connecting a schedule timer to the central remote controller

• Central remote controllerTCB-SC642TLERBC-CM1280TLE

+• Schedule timer

TBC-EXS21TLE

Indoor remote controller• Wired remote controller

RBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kit

3-3

Either one of the two controllers can be set as

side control without indoor remote controller.

• Central remote controllerTCB-SC642TLE2

Indoor remote controller• Wired remote controller

RBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Wireless remote controller kit

Basic function System diagram Model

Outdoor unitU3, U4

U1, U2

Indoor remote controller

Indoor unit

Schedule timerCentral

remote controller

Power supply

Single phase 220V

Even when grouping operation is performed by connecting multiple indoor units to 1 line, the indoor remote controller is required.

Available

Available

U3, U4 Outdoor unitU1, U2

Indoor unitPower supply

Central remote controller

Single phase220V

Example of grouping operation

U3, U4Outdoor unitU1, U2

(Group)

Indoor remote controller is required

Central remote controller

Power supply

U3, U4Outdoor unitU1, U2

(Group)Power supply

Central remote controller

Single phase220V

Single phase220V

Page 5: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-510

3-4 Central management control with ‘‘1 : 1 model’’

* TOSHIBA Digital Inverter System and Super Digital Inverter System

• Central remote controllerTCB-SC642TLE2BMS-CM1280TLE

• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).

Indoor remote controller• Wired remote controller

RBC-AMT32ERBC-AMT31E

• Wired remote controller with weekly timer RBC-AMS41E

• Simple wired remote controllerRBC-AS21E2

• Wireless remote controller kit

Basic function System diagram Model

Super MMS * 1

Power supply

Central remote controller

U3, U4

U1, U2

Header unit

Indoor unit

Indoor remote controller

“1 : 1 model” connection interface

Page 6: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-610

4. Application control for network

Basic function System diagram Model

4-1-1 LONWORKS

*1TOSHIBA Digital Inverter System and Super Digital Inverter System

The LONWORKS interface should be connected between a building management computer and a Super MMS air conditioning system.

• LN InterfaceTCB-IFLN640TLE

• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).

4-1-2 BACnet

*1TOSHIBA Digital Inverter System and Super Digital Inverter System

The local server should be connected to the BACnet network, and the Super MMS air conditioning system through the interface.

• Intelligent serverBMS-LSV6E

• BACnet server softwareBMS-STBN08E

• TCS-Net Relay InterfaceBMS-IFLSV3E

• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).

4-1-3 Modbus

*1TOSHIBA Digital Inverter System and Super Digital Inverter System

• Modbus InterfaceTCB-IFMB640TLE

• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).

TCB-

Super MMS

LN Interface

Remote controller

LON centerLON WORKS

TCB-IFLN060

TCB-

* 1

“1:1 model”connection interface

• • •

TCB-

Super MMS

Intelligent server

TCS-NetRelay Interface

Remote controller

BACnet center

* 1

“1:1 model”connection interface

■ BACnet server software

TCB-

Super MMS

Modbus Interface

Remote controller

Modbus

* 1

“1:1 model”connection interface

Page 7: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-710

Touch screen controller system

System diagram

4-2-1

Dev

ices

Model Name Model Name SpecificationTouch Screen controller BMS-TP0641ACE Max. 64 indoor units, without electrical bill calculation

BMS-TP5121ACE Max. 512 indoor units, without electrical bill calculationBMS-TP0641PWE Max. 64 indoor units, with electrical bill calculationBMS-TP5121PWE Max. 512 indoor units, with electrical bill calculation

TCS-Net Relay Interface BMS-IFLSV3E I/F in between Touch Screen controller & Control wiringEnergy Monitoring Relay Interface BMS-IFWH4E2 I/F for Power MeterDigital I/O Relay Interface BMS-IFDD02E2 I/F for I/O signal

Func

tion

(1) Monitoring air-conditioners Operation status can be viewed according to a unit.[Unit] All building, All tenants, Each tenant, Each area, Each air-conditioning system[Monitoring contents] Operation and alarm status, Setting status for each air-conditioning system

(2) Operating of air-conditioners Header/individual control can be performed according to a unit.[Operating contents] ON/OFF, Operation setting (operation mode, air volume, louver position,

setting temp., restricted setting from remote location)(3) Schedule operation Air-conditioners are operated according to the set-up schedule/operation pattern.

Schedule operataion can be performed according to a unit.[Operation pattern] Weekly pattern, special day pattern (4 pattern), Non-operation days pattern

(4) Alarm list display The present alarm contents are list-displayed.[Display contents] Alarm contents, Unit number, Generated time

(5) Alarm record display The alarm history records are displayed.[Display contents] Alarm contents, Unit number, Generated time

(6) Monthly report data extraction Monthly report data is written to ‘‘Compact Flash’’. Monthly reports can be created according to a unit using the monthly report software.[Monthly report contents] The number of ON/OFF, Operating time, Results of energy monitoring

Monthly report creation software

1:1model

Touch Screen Controller

Ethernet

RS-485 Relay I/F

Power Meter Energy monitoring Relay I/F

Digital I/O Relay I/F

Pulse signal

Digital I/O signal Fire alarmDoor key Error

TCC-link bus

TCC-link bus Fire alarm Door key etc

Digital I/O signal

Max12

Max8

Max8

Max8

Max In 8 /Out 4

Max In3 /Out3

Relay I/F

Connection I/F

Max 64/512 Indoors/groups

Power meter: Pulse width:50-1000ms Pulse generator constants (kWh/pulse) 0.1-99.9

Page 8: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-810

Compliant Manager

System diagram

4-2-2

• Compliant ManagerBMS-CM1280TLE

• Compliant Manager with WEBBMS-CM1280FTLE

TCC-LINK LINE 1

Compliant Manager

TCC-LINK LINE 2

Local Supply (BMS-CM1280FTLE only)

HUB

Monitoring

Zone setting (64 zone x ~ 2)Individual units operation (ON/OFF, Operation mode, Setting temperature, Air volume, Filter sign)Operation restrictionAlarm display

Operation

Individual operationMax. 128 indoor unitsReturn Back operationWeekly Schedule Operation* (ON/OFF)External control inputStatus outputFire alarm inputAlarm display * accessory necessary

Web Application (WEB model only)

Network connectionSchedule operation (ON/OFF, Setting temperature, operation mode and Remote control Permit/Prohibit)Alarm historyEnergy monitoring external connection* * accessory necessary

Page 9: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-910

WEB Based Controller

System diagram

4-2-3

WEB Based Controller• Gateway Server

BMS-WB2561PWE• TCS-Net Relay I/F

BMS-IFLSV3E

• Energy Monitoring Relay I/FBMS-IFWH4E2

• Digital I/O Relay I/FBMS-IFDD02E2

4-2-4

WEB Based Controller• Master server

BMS-WB01GTE• Gateway Server

BMS-WB2561PWE• TCS-Net Relay I/F

BMS-IFLSV3E

• Energy Monitoring Relay I/FBMS-IFWH4E2

• Digital I/O Relay I/FBMS-IFDD02E2

System diagram for connecting 256FCUs or less

BMS-WB2561PWE(Web Server) TCS-Net Relay I/F

TCC-LINK

TCC-LINK

SMMS

SMMS SMMS

MiNi-SMMS

BMS-IFLSV3E

BMS-IFLSV3E

TCS-Net Relay I/F

I/F for Power Meter(BMS-IFWH4E2)

I/F for I/O signal(BMS-IFDD02E2E)

Ethernet

RS-485

Network, Intranet, connection through LAN port

HUB

Local Supply

System diagram for connecting 257FCUs or more

Local Supply

BMS-WB01GTE(Master Server)

TCS-Net Relay I/F

TCC-LINK

TCC-LINK

SMMS

SMMS

SMMS

SMMS

SMMS

MiNi-SMMS

BMS-WB2561PWE(Gateway)

HUB

Ethernet

RS-485

SMMS

MiNi-SMMS

TCS-NetRelay I/F

TCS-Net Relay I/F

TCS-NetRelay I/F

TCC-LINK

TCC-LINK

I/F for Power Meter (BMS-IFWH4E2)

I/F for I/O signal(BMS-IFDD02E2E)

BMS-WB2561PWE(Gateway)

Network, Intranet, connection through LAN port Enable to connector up to 2,048 FCUs

RS-485

Page 10: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-1010

Application control of optional devices connectable to indoor units

[1] Remote location ON/OFF control box

[2] ‘‘1 : 1 model’’ connection interface

Model Name Appearance Features

TCB

-IFC

B-4

E2

Start and stop of the air conditioner is possible by a external signal and indication of operation/alarm externally.

Application Function

• MonitoringON/OFF status (for indoor unit)Alarm status (system & indoor unit stop)

• ON/OFF commandAir conditioner can be turned ON/OFF by external signals.The external ON/OFF signals will initiate the signals shown below.

Model Name Appearance Features

TCB

-PC

NT3

0TLE

2

Install optional P.C. board in Electrical parts box of indoor unit.

Link adapter for ‘‘1 : 1 model’’ into super modular multi network

1 : 1 model: Super digital inverter Digital inverter

Connection of cables

Application

Wiring diagram of indoor P.C. board

Display

Operation

Interface

RemoteController ON/OFF

COM

Non-voltageON/OFF continious signal

ON-OFFcontroldevices

Central Remote Controller

1:1 model connection

interfaceIndoor units

Super MMS control wiring

Digital Inverter Super Digital Inverter

Outdoor unit

Metal fitting kit (TCB-PX30MUE) is necessary for 4-way and Compact 4-way cassette type.

adoptor

Page 11: 1. Outline of application Control - CarrierTCB-IFMB640TLE BMS-LSV6E BACnet Server LONWORKS BACnet General Purpose I/F TCB-IFCG1TLE Touch-screen Controller BMS-TP0641ACE BMS-TP5121ACE

10Controls

-1110

Application controls by optional P.C. board of outdoor unit

Model name Application Feature

TCB

-PC

DM

4E

* Install these optional P.C.Board in the inverter assembly of the header outdoor unit.

[1] Power peak-cut ControlThe upper limit capacity of the outdoor unit is restricted based on the power peak cut request signal from outside.

TCB

-PC

MO

4E

[2] Snowfall fan controlOutdoor fan is operated by a snowfall signal from outside.

[3] External master ON/OFF controlThe outdoor unit starts or stops the system.

[4] Night operation (Sound reduction) controlSound level can be reduced by restricting the compressor and fan speeds.

[5] Operation mode selection controlThis control can restrict the selectable operation mode.

TCB

-PC

IN4E [6] Error/Operation output control

Error/operation are displayed and output.[7] Compressor operation output control

Three compressor’s operation/stop output[8] System operation output control