Activity measurements at the microfluidic scale: towards osmotic pressure measurements1
GDR CNRS AMC2October 20-22, SteZIANE NadiaSupervisors: J. Leng and JB. SalmonIntroductionDialysis process: Perfect control of the environment Concentration of non-volatile solutes in aqueous solutionsTowards phase diagrams
Microfluidics interests:Linear geometryEasy observations of confined volumeEasy analysis and fast experiments
2Microfluidic chip3
PDMSPDMS membranee = 30 40 mglass slide rectangular channelw = 50 60 mh = 30 40 mL0 = 1,5 3 cmL0 hnLRandall and al., 2005Salmon and Leng, 2010 Water pervaporation4
4
Channel geometry: confined drop5Step 1Fill dead-end microchannels Step 3Evaporation of confined dropletsStep 2Injection of a fluorinated oil or airL0 = 1,5-3 cm
60 mNoblin and al., 2008Simple model for solutions and dispersions6
Continuous and uniform concentration (t) = 0 L0 /L(t)
Evaporation rate controlled by activity Hypotheses:
No initial gradientsPe = hV/D < 1 no vertical gradientsPervaporation rate uniform along xQuasi steady regime for water pervaporation6
Absorbance measurements7 Bleu brillant FCF at 0,1 mM (10x) No gradients for molecular solutions200 m
Fluorescence meausurements8Fluorescent latex (40x)Gradients at x=0 : evidence of leakage velocityDiameter = 20 nm
J. Angly and al., 2012x=0x=Lg50 m
Fluorescence meausurements9Gradients at x=0 : evidence of leakage velocity
Gradients at x=Lg : is not true
Fluorescent latex (40x)Diameter = 200 nm hTD = h/DT = h/Vx=0x=Lg50 m9Pure water 10
Time ~ 1h30 Image analysisPure water 11
Accurate estimation of humidy using 1D modelVf ~ 0,52 m/sTe ~ 1500 sBinary water/glycerol mixture12
Water/glycerol 2% v/vRoom humidity = 60%h = 26 m, time ~ 2 hrNinni and al., 2000
Binary water/glycerol mixture13
Te ~ 2200 s
Binary water/glycerol mixture14
Binary water/glycerol mixture15
Conclusion & outlooksRobust measurements of the activity of aqueous solutions at the nanoliter scale
New chip design
16
17Estimation of liquid-liquid transition of ternary system PEG/water/ammonium sulfate Conclusion & outlooksPEG: 5% w/w
Ammonium sulfate:5% w/wTime ~ 1h20 Conclusion & outlooks18
Development and characterization of new microfluidic devices including dialysis membranes
Control of osmotic exchanges at a nanoliter scale
Quantitative measurements of thermodynamic properties of complex fluidsMicrodialysis processHsieh, 2007Jensen and al., 2008Thank youQuestions ?19