1 gas-phase actinide chemistry studies utilizing fourier transform ion cyclotron resonance mass...

44
1 utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

Upload: isabella-boyd

Post on 30-Dec-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

1

Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy

John Langridge

Chem 5460

Dr. Chyan

Page 2: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

2

OutlineI. A generalized view of Mass Spectroscopy

II. Fundamentals of FTICR-MS

III. Why gas phase?

IV. Actinide studies – applicationWhy study Actinides?ReactivityKinetics and Reaction efficienciesThermodynamicsIonization and bond energy

Page 3: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

3

I. A generalized view of Mass Spectroscopy

How stuff works website; http://science.howstuffworks.com/mass-spectrometry3.htm (accessed April 23, 2011)

Page 5: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

5

Fundamentals of FTICR-MSFunctions of ion mass

Radius

Velocity

Energy

Ion cyclotron frequency

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 6: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

6

Fundamentals of FTICR-MSIon cyclotron resonance (ICR)

• ICR frequency = fundamental resonant frequency of species

• Feature: Ions of given m/z are same regardless of velocity

• When ICR = excitation frequency, cyclotron motion results

• Cyclotron motion pr s on m/q w t outhigh eci i i h tr nsl t on la a i a n r / o us ne e g f c i g

• Factor separating FTICR-MS from other methods

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 8: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

8

Fundamentals of FTICR-MS:Components

Ion sources

External is best

Avoids magnetic perturbations

Sometimes at cost of ion optics

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 9: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

9

Fundamentals of FTICR-MS:Components

Ion trapping E field + H field

Trapping alone kinetic energy + mass/charge

ICR frequency sweep orbital transition

Collision induced dissociations (CID) of ions with gas

Changing system

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 10: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

10

Fundamentals of FTICR-MS:Components

Detection: ion time varying AC signal

Current AC “image” coupling to detector plates

analogous to broadcast model

Ions are part of the circuit!

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 11: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

11

Fundamentals of FTICR-MS:Components

Fourier transformation

Time domain frequency domain

ICR frequency proportional to m/z

Increases potential resolution

• Ion is “seen” multiple times – high path length

• Averaging: improved S/N

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 13: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

13

Useful application: excitation cyclotron motion

Not mutually exclusive

3 common configurations

Acceleration to larger radius then detection

Increase KE above threshold for reaction or dissociation CID

Mass selection as a function of acceleration and increased radiusA. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 14: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

14

Uses for cyclotron excitation

•ICR higher potential mass resolution

• Path length of excited ion is > 30000km/1s time scale

• Few ions used (comparatively speaking) to minimize space charge perturbations

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 15: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

15

ICR orbital frequency vs. m/z

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 16: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

16

ICR orbital radius vs. m/z

A. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.

Page 17: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

17

III. Why gas-phase?

Simply put:

Avoids effect of lattice structure

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 18: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

18

Classical view of gas-phase interactions (CID)

Attraction between ion and neutral

Potential well forms from attraction

Exceed the reaction barrier E products

Supersonic expansion kinetic studiesUniversity of Bristol: Center for mass spectroscopy http://www.chm.bris.ac.uk

/ms/theory/fticr-massspec.html (accessed April 18, 2011)

J. K. Gibson, et al, Eur. Phys. J. D. 45 (2007), 133.

Page 19: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

19

Gas-phase ionizationLaser ablation with prompt reaction and detection (LAPRD)

Laser ablates metal to vapor

Prompt reaction with neutral

OR

Laser/metal ablation plasma acceleration to trap

Backing gas introduces species to ion trap A. Marshall, et al. Mass Spectrometry Reviews 17 (1998), 1.J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 20: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

20

Gas-phase ionization

Laser desorption ionization

An-Pt alloy, 2% weight

Singly and doubly charged cations

Direct coupling to trap reduced loses

A. Marshall, et al. Mass Spectrometry Reviews 17 (1998), 1.

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 21: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

21

IV. Why study actinides?

Better understanding of natural laws

Materials science applications

Waste management/weapons programs

Medical applications

Page 22: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

22

Application to actinide chemistry

Reactivity

Page 23: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

23

Reactivity and FTICR-MSStudied via LAPRD and LDI

Neutral/ion interaction quadrupole stage/ion trap.

Alkene interactions; electron density in double bond available upon activation

Fragmentation = mass change bond formation provide clues about reactions

Relative abundance = amplitude of the frequency domain signalA. Marshall, et al. Mass Spectrometry Reviews 17 (1998), 1.

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 24: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

24

Reactivity of actinide ions (1+)

Th+ > Pa+ > U+ = Np+ > Cm+ > Pu+ > Bk+ > Am+ = Cf+ > Es+

Thorium transition metal character

Curium half filled f-orbital

Plutonium / Americium no 6d

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 25: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

25

Reactivity of An+

Promotion energy driven, 5fn-26d7s (filled) vs. 5fn-26d2 (open)

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 26: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

26

Actinyl ion vs. An2+

ThO+, UO+ , UO22+ only slightly reactive

Strong metal ion to oxygen bond impacts reactivity

Th 2+ and U2+

Highly activating to hydrocarbons, particularly arenes

cationic charge abstraction (2+) More efficient than 1+

J. Marcalo, J.P. Leal, A. P.de. Matos, Organometallics 16 (1997), 4581.

Page 27: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

27

Application to actinide chemistry

Kinetics and reaction efficiencies

Page 28: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

28

Kinetics, reaction efficiencies and FTICR-MS

Change must accompany ion-neutral collisions (product formation)

Frequency domain studied in a time domain “how does frequency change over a span of time?”

Concentrations related to relative amplitudes of signals

A. Marshall, C. Hendrickson, G. Jackson, Mass Spectrometry Reviews 17 (1998), 1.

Page 29: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

29

Reaction kinetics and efficiencies

Efficiencies ratio of experimental data and theoretical calculations

Kexp / Kcol = reaction efficiency

Kcol theoretical collisional rate constant

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 30: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

30

Reaction kinetics and efficiencies

Strong correlation: reaction efficiency promotion energy of An+

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 31: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

31

Reaction kinetics and efficienciesEfficiency/promotion energy correlation does not strictly exist for An2+ species

Ground state divalent state = high promotion energy with 2 unpaired non-f electrons for all but Th2+

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 32: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

32

Promotion energy and kinetics

Promotion energy controls reactionsHigher promotion energy indicates kinetic restrictions

M. Santos, et al. Int. J. Mass Spectrometry 228 (2003), 457.

Page 33: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

33

Application to actinide chemistry

Thermodynamics

Page 34: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

34

Thermodynamics and FTICR-MSBond dissociation energy

Energy of known sample fragment based on resonant freq and Kinetic Energy

CID fragments sample further

• Results in a new resonant frequency

Difference in E is BDE

A. Marshall, C. Hendrickson, G. Jackson, Mass Spectrometry Reviews 17 (1998), 1.

Page 35: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

35

Thermodynamics of actinide oxides

Oxidation studies BDE

Broad range of Oxygen dissociation energies known

An+-O, An2+-O, OAn+-O, OAn2+-O

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 36: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

36

Thermodynamics of actinide oxides

OPu+-O 250 kJ/mol too low

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.

Page 37: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

37

Thermodynamics of actinide oxides

Recently: PaO22+ intermediate state between 5+

and 6+

Experimentally and computationally confirmed

Thermodynamic instability in the species

Similar to simultaneous multi-state behavior seen in plutonium (4 states in single solution)

J. K. Gibson, et al. Eur. Phys. J. D. 45 (2007), 133.

Page 38: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

38

Application to actinide chemistry

Ionization Energy and Bond Energy

Page 39: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

39

Ionization energy-actinide oxides

Ions reacted with neutrals of known IE (CID)

Electron transfer of ion neutral• Establishes limits of ion electron affinities of the neutrals

2+ difficult due to coulombic interactions in product increase energy barriers

Formation enthalpy estimates made from bond and ionization energies

J. K. Gibson, J. Marçalo, Coord. Chem. Rev. 250 (2006), 776.J. K. Gibson, et al. Eur. Phys. J. D. 45 (2007), 133.M. Santos, et al. Int. J. Mass Spectrometry 228 (2003), 457.

Page 40: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

40

Complications of studying late actinides – issue one

Sample size

• Sub-milligram (literally microgram) samples typical

• Highly efficient ion source

• Smaller sample = fewer ions; 10-100 trapped ions necessary for decent resolution

J. K. Gibson, et al. Eur. Phys. J. D. 45 (2007), 133.

Page 41: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

41

Complications of studying late actinides – issue two

Half-life

• Late / Trans-actinides half-life < 1s

• Isotope production facility directly coupled to trap

J. K. Gibson, et al. Eur. Phys. J. D. 45 (2007), 133

Page 42: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

42

ConclusionsFirst time comparison of theoretical and experimental actinide data

FTICR-MS = High resolution high path length

Combine with other MS techniques

High flexibility; many options

Via ion manipulations

Page 43: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

43

Page 44: 1 Gas-phase actinide chemistry studies utilizing Fourier transform ion cyclotron resonance mass spectroscopy John Langridge Chem 5460 Dr. Chyan

44

Cyclotron motion

ReturnA. Marshall, et al., Mass Spectrometry Reviews 17 (1998), 1.