- part 4 - amazon s3 · no representation or warranty is given that your particular application of...

21
No representation or warranty is given that your particular application of these products complies with relevant building codes or that the fasteners provided or used are appropriate for your application. Therefore consult with professionals and local building officials before beginning work: (i) to ensure compliance with relevant building codes for your application and for your proposed use of fasteners; (ii) to ensure the integrity of the structural components in connection with which these products are to be used; (iii) to identify appropriate safety gear that is to be used during installation such as a safety harness when working above ground; (iv) to ensure that the work area is free from utilities, services and hazards; and, (v) to clarify any instructions or warnings that may not be clear. Work in a safe manner wearing protective gear such as gloves, eyewear, headwear, footwear and clothing. When using tools always comply with operation manuals and instructions. Metal and glass may have sharp edges and could fragment or splinter during or as a result of handling or cutting. Do not use these products in connection with any substance that is or may be harmful or corrosive to the products. Inspect and maintain these products and the structural components that they are used in connection with on a regular basis using professionals when appropriate. These instructions have been prepared for certain standard residential applications. Obtain professional advice for any non-standard or non-residential application. WARNING - Part 4 - Part 4 - Part 4

Upload: ngocong

Post on 07-Apr-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

No representation or warranty is given that your particular application of these products complies withrelevant building codes or that the fasteners provided or used are appropriate for your application.

Therefore consult with professionals and local building officials before beginning work: (i) to ensure compliance with relevant building codes for your application and for your proposed use of fasteners; (ii) to ensure the integrity of the structural components in connection with which these products are to be used; (iii) to identify appropriate safety gear that is to be used during installation such as a safety harness when working above ground; (iv) to ensure that the work area is free from utilities, services and hazards; and, (v) to clarify any instructions or warnings that may not be clear. Work in a safe manner wearing protective gear such as gloves, eyewear, headwear, footwear and clothing. When using tools always comply with operation manuals and instructions. Metal and glass may have sharp edges and could fragment or splinter during or as a result of handling or cutting. Do not use these products in connection with any substance that is or may be harmful or corrosive to the products. Inspect and maintain these products and the structural components that they are used in connection with on a regular basis using professionals when appropriate. These instructions have been prepared for certain standard residential applications. Obtain professional advice for any non-standard or non-residential application.

WARNING

• - Part 4• - Part 4• - Part 4

RAILBLAZERS® Aluminum Railing System

Engineering Review for Compliance with Canadian

Building Codes Part 4

Peak Products Manufacturing Inc.

December 14, 2016

RJC No. VAN.106169.0014

Prepared for:

Peak Products Manufacturing Inc.

www.peakproducts.com

Prepared by:

Read Jones Christoffersen Ltd.

1285 West Broadway, Suite 300

Vancouver BC V6H 3X8

RAILBLAZERS® Aluminum Railing System Engineering Review for Compliance with Canadian Building Codes Part 4

December 14, 2016 RJC No. VAN.106169.0014

Table of Contents

1 . 0 O V E R V I E W 1

2 . 0 I N F I L L E L E M E N T S 2

2 . 1 A l u m i n u m I n f i l l E l e m e n t s 2

2 . 2 G l a s s I n f i l l E l e m e n t s 2

3 . 0 R A I L E L E M E N T S 2

3 . 1 G e n e r a l R a i l E l e m e n t s 2

4 . 0 C O N N E C T O R S 3

4 . 1 C o n n e c t o r s 3

5 . 0 R E S U L T S 3

6 . 0 C O N C L U S I O N 3

APPENDIX A: LIST OF COMPONENTS

APPENDIX B: ASSEMBLY DRAWINGS

RAILBLAZERS® Aluminum Railing System Engineering Review for Compliance with Canadian Building Codes Part 4

December 14, 2016 RJC No. VAN.106169.0014 page 1

1 . 0 O VE RVIE W

The RailBlazers® Aluminum Railing System is intended to act as a guard or barrier to protect the public

from a fall. The objectives were to complete a structural review of the structural components based

on Limit States Design, in accordance with applicable material standards and Part 4 of the following

Canadian building codes:

Alberta Building Code 2014

British Columbia Building Code 2012

National Building Code of Canada 2015

The following specified loads apply:

Concentrated lateral load of 1 kN (applied to the Railing System at top of guard)

Uniformly distributed lateral load of 0.75 kN/m (applied at top of guard)

Uniformly distributed vertical load of 1.5 kN/m (applied at top of guard)

Concentrated infill load of 0.5 kN (anywhere within the guard)

Concentrated live load of 0.1 kN applied in opposite directions on two individual infill elements

within a guard shall result in an opening size no greater than 100mm

Uniform wind load per the limits shown in Appendix B Assembly Drawings

In this report, the following structural components were reviewed:

A. Infill Elements

1. Wide aluminum pickets 38 mm (1½”) wide

2. Glass panels up to 1.676 m (66”) wide

3. Glass panels 152 mm or 6” wide

B. Rail Elements

1. Post

2. Railing Handrail

3. Railing Base rail

C. Connectors

1. Universal connector

2. Wall mount brackets

3. Mid/stair/end fascia mount bracket

4. Corner fascia mount bracket

The complete list of all components (including non-structural components) for the system is included

in Appendix A.

RAILBLAZERS® Aluminum Railing System Engineering Review for Compliance with Canadian Building Codes Part 4

December 14, 2016 RJC No. VAN.106169.0014 page 2

2 . 0 INF IL L E L E ME NT S

The primary infill elements included: 38 mm (1½”) wide aluminum picket, 6 mm (¼") thick glass panels

(up to 1.676 m (66”) wide), and 8 mm (5/16”) thick glass panels (152 mm (6”) wide).

The review was based on information and drawings provided by Peak Products Manufacturing Inc.

(Peak) for the elements listed above.

2 . 1 A lu m in u m In f i l l E lem e n ts

Our analysis was based on the following information:

Loads: Prescribed by the Canadian building codes. See Section 1.0, Overview.

Resistance: Completed in accordance with CAN/CSA S157-05 (R2015), Strength in Aluminum

Design.

Section properties: Determined from drawings provided by Peak. Calculations were completed in

accordance with CAN/CSA S157-05 (R2015).

Load configuration: Span and bearing lengths were provided by Peak.

2 . 2 G la s s In f i l l E lem en ts

Our analysis was based on the following information:

Loads (Live and Wind): Prescribed by the Canadian building codes. See Section 1.0, Overview.

Resistance: Completed in accordance with CAN/CGSB 12.20-M89, Structural Design of Glass for

Buildings.

Material: Tempered glass in accordance with CAN/CGSB-12.1-M90 per information and drawings

provided by Peak.

Section properties: Determined from drawings provided by Peak.

Load configuration: Span and bearing lengths were provided by Peak. The glass panels were

analyzed based on having pinned (simply-supported) ends at the top and bottom.

Allowable deflection: The allowable deflection was calculated based on preventing fall-out of the

glass from the frame.

3 . 0 RA IL E L E ME NT S

3 . 1 G en er a l Ra i l E lem en ts

The general rail elements include the hand rail, base rail, and posts. An analysis was completed based

on the worst-case configuration for these elements.

Loads: Prescribed by the Canadian building codes. See Section 1.0, Overview.

Resistance: Completed in accordance with CAN/CSA S157-05 (R2015), Strength in Aluminum

Design.

Section properties: Determined from drawings provided by Peak. Calculations were completed in

accordance with CAN/CSA S157-05 (R2015).

Fastener resistance: Completed in accordance with CAN/CSA S16-14, Design of Steel Structures.

RAILBLAZERS® Aluminum Railing System Engineering Review for Compliance with Canadian Building Codes Part 4

December 14, 2016 RJC No. VAN.106169.0014 page 3

Load configuration: Span and dimensions were provided by Peak. Posts were modeled as

cantilevers, fixed at the base. The results from our analysis show the maximum span that can be

achieved, as calculated from the material and fastener resistances.

4 . 0 C O NNE C T O RS

4 . 1 C o n n ecto r s

The general connectors included the universal connector, wall mount brackets, mid/stair/end fascia

mount bracket, and corner fascia mount bracket. An analysis was completed based on the worst-case

configuration for these elements.

Loads: Prescribed by the Canadian building codes. See Section 1.0, Overview.

Resistance: Completed in accordance with CAN/CSA S157-05 (R2015), Strength in Aluminum

Design and CAN/CSA S16-14, Design of Steel Structures.

Section properties: Determined by drawings provided by Peak. Calculations were completed in

accordance with CAN/CSA S157-05 (R2015).

Load configuration: Span and dimensions were provided by Peak.

Connections to the base building are not included as part of this review, including but not limited

to the rail and post connections.

5 . 0 RE S U L T S

A full set of calculations and results is presented in RJC #VAN.106169.0014 engineering review

package, including:

Dimensioned drawings of each component, including extrusion drawings

Calculation sheets for the structural capacity of components listed in 1.0 Overview

The above documents contain proprietary information and as such, have not been included in this

report.

6 . 0 C O NC L US IO N

The RailBlazers® Aluminum Railing System meets the requirements within Part 4 of the Alberta Building

Code 2014, British Columbia Building Code 2012 and National Building Code of Canada 2015.

Limitations of compliance are defined in the assembly drawings presented in Appendix B.

APPENDIX A

LIST OF COMPONENTS

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 1 Appendix A - List of Components RJC No. VAN.106169.0014

Read Jones Christoffersen Ltd.

SKU (White)

SKU (Black)

Description

10000 10001 END POST

10010 10011 MID POST

10020 10021 CORNER POST

10050 10051 STAIR POST

10100 10101 4’ HAND AND BASE RAIL

10110 10111 6’ HAND AND BASE RAIL

10350 10351 24’ WIDE PICKETS AND SPACERS

10360 10361 6’ WIDE STAIR PICKETS AND SPACERS

10710 10713 6” GLASS PANEL & GASKET

10820 10820 GLASS PANEL 18” x 3 5/16”

10823 10823 GLASS PANEL 21” x 3 5/16”

10830 10830 GLASS PANEL 24” x 3 5/16”

10833 10833 GLASS PANEL 27” x 3 5/16”

10840 10840 GLASS PANEL 30” x 3 5/16”

10843 10843 GLASS PANEL 33” x 3 5/16”

10850 10850 GLASS PANEL 36” x 3 5/16”

10853 10853 GLASS PANEL 39” x 3 5/16”

10860 10860 GLASS PANEL 42” x 3 5/16”

10863 10863 GLASS PANEL 45” x 3 5/16”

10866 10866 HEAT SOAKED GLASS PANEL 42” x 36 5/16”

10870 10870 GLASS PANEL 48” x 3 5/16”

10873 10873 GLASS PANEL 51” x 3 5/16”

10880 10880 GLASS PANEL 54” x 3 5/16”

10883 10883 GLASS PANEL 57” x 3 5/16”

10888 10888 GLASS PANEL 60” x 3 5/16”

10891 10891 GLASS PANEL 63” x 3 5/16”

10895 10895 GLASS PANEL 66” x 3 5/16”

10900 10901 UNIVERSAL CONNECTOR

10920 10921 WALL MOUNT BRACKET

10940 10940 6’ GLASS GASKET

10960 10961 CORNER FASCIA MOUNT BRACKET

10970 10971 MID/END/STAIR FASCIA MOUNT BRACKET

APPENDIX B

ASSEMBLY DRAWINGS

SEE DRAWING:RAILBLAZERS® ALLOWABLE SPANS

107

0 m

m [4

2-1/

8 in

]

MAXIMUM: 98 mm [3-27/32 in]

SEE DRAWING: POSTS SEE DRAWING: BRACKETS AND CONNECTORS

3

45

1

2

ITEM NO. DESCRIPTION SKU

1 WIDE PICKET 10350, 10351

2 SPACER (98 mm) 10350, 10351

3 HAND RAIL 10100, 10101, 10110, 101114 BASE RAIL 10100, 10101, 10110, 101115 POST 10000, 10001, 10010, 10011, 10020, 10021

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:15

RailBlazers® - Railing Assembly with Wide Pickets

Report assembly P4 Assembly Wide Pickets

DO NOT SCALE DRAWING

Report assembly P4 64in- wide picketsPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 1 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

107

0 m

m [4

2-1/

8 in

]

MAXIMUM: 100 mm [3-15/16 in]

SEE DRAWING:RAILBLAZERS® ALLOWABLE SPANS

SEE DRAWING: POSTSSEE DRAWING: BRACKETS AND CONNECTORS

6 mm (1/4 in) TEMPERED GLASSCAN/CGSB-12.1-M90

2

3

1

4

5

6

ITEM NO. DESCRIPTION SKU1 POST 10000, 10001, 10010, 10011, 10020, 100212 HAND RAIL 10100, 10101, 10110, 101113 BASE RAIL 10100, 10101, 10110, 10111

4 GLASS PANEL 10820, 10823, 10830, 10833, 10840, 10843, 10850, 10853, 10860, 10863, 10866, 10870 ,10873, 10880, 10883, 10888, 10891, 10895

5 LOWER GLASS GASKET 109406 UPPER GLASS GASKET 10940

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:15

RailBlazers® - Railing Assembly with Glass Panel

Report assembly P4 Assembly Glass Panel

DO NOT SCALE DRAWING

Report assembly P4 - 64in span- glass panelPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 2 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

1.270 m (50 in)

1.066 m (42 in)

42 in GLASS PANEL1

6 2 79

1.625 m (64 in)

1.447 m (57 in)

57 in GLASS PANEL

6

83

4 9

1.625 m (64 in)

1.066 m (42 in)

42 in GLASS PANEL AND FOUR WIDE PICKETS EACH SECTION

4 5 6

73

9

1.594 m (62-3/4 in)

1.066 m (42 in)

3

56

7

4

42 in GLASS PANEL AND TWO WIDE PICKETS EACH SECTION

9

ITEM NO. DESCRIPTION SKU1 HANDRAIL 4 FT 10100, 101012 BASE RAIL 4 FT 10100, 101013 HANDRAIL 6 FT 10110, 101114 BASE RAIL 6 FT 10110, 101115 WIDE PICKET 10350, 103516 POST 10000, 10001, 10010, 10011, 10020, 100217 GLASS PANEL 42 IN 108608 GLASS PANEL 57 IN 108809 GLASS GASKET 10940

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:25

RailBlazers® - Glass Panel Configuration Examples

Report assembly P4 Glass Examples

DO NOT SCALE DRAWING

Report assembly P4 50in repeating glass panelPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 3 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

107

0 m

m [4

2-1/

8 in

]

MAXIMUM: 96 mm (3-25/32 in]

SEE DRAWING:RAILBLAZERS® ALLOWABLE SPANS

SEE DRAWING: POSTS SEE DRAWING: BRACKETS AND CONNECTORS

8 mm (5/16 in) TEMPERED GLASSCAN/CGSB-12.1-M90

2

3

1

4

5

ITEM NO. DESCRIPTION SKU1 POST 10000, 10001, 10010, 10011, 10020, 100212 HAND RAIL 10100, 10101, 10110, 101113 BASE RAIL 10100, 10101, 10110, 101114 6" GLASS PANEL AND GASKET 10710, 107135 SPACER 10710, 10713

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:15

RailBlazers® - Railing Assembly with 6" Glass Panels

Report assembly P4 Assembly 6in Glass Panel

DO NOT SCALE DRAWING

Report assembly P4 64in glass picketsPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 4 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

SEE DRAWING:

RAILBLAZERS® ALLOWABLE STAIR SPANS

MAXIMUM: 98 mm [3-27/32 in]

UNIVERSAL CONNECTOR KIT

SEE DRAWING: POSTS

2

5

3

1

4

6

28 m

m[1

-3/3

2 in

]

7.2 m

m

[9/32

in]

UNIVERSAL CONNECTOR

MOUNTINGTEMPLATE:

ITEM NO. DESCRIPTION SKU1 POST 10000, 10001, 10010, 10011, 10020, 10021, 10050, 100512 HANDRAIL 10100, 10101, 10110, 101113 BASE RAIL 10100, 10101, 10110, 101114 UNIVERSAL CONNECTOR 10900, 109015 WIDE STAIR PICKET 10360, 103616 STAIR SPACER 10360, 10361

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:15

RailBlazers® - Stair Railing with Wide Pickets

Report assembly P4 Stair WIDE Pickets

DO NOT SCALE DRAWING

Report assembly - stair - Wide pickets - CANPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 5 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

MAXIMUM: 1880 mm [74 in] SINGLE RAILING PICKET SECTION

MAXIMUM: 1838 mm [72 ⅜ in ] WALL MOUNT PICKET SECTION

MAXIMUM: 1625 mm [64 in] MAXIMUM: 1625 mm [64 in]

MULTIPLE RAILING PICKET SECTIONS

ALLOWABLE SPANS* 6 in GLASS PANELS AND GLASS PANELS UP TO 1.676 m (66 in)

*Note: The above wind loads provided are guidelines for typical building types for a q50 = 0.48kPa in rough terrain.Actual wind loads must be determined by a professional engineer for the intended location.

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:20

RailBlazers® - Allowable Spans

Report assembly P4 Allowable Spans

DO NOT SCALE DRAWING

Report assembly P4 Span 74inPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 6 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

MAXIMUM: 1880 mm [74 in]

SEE NOTE SEE NOTE

MAXIMUM: 1859 mm [73- / in ]

SEE NOTE SEE NOTE

L-SHAPED CORNER SECTION: WALL MOUNT163

L-SHAPED CORNER SECTION: END POST

NOTE: Refer to drawing "RailBlazers® - Allowable Spans" for multiple railing section allowable spans.

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:20

RailBlazers® - Allowable spans for a single return section

Report assembly P4 L-Return

DO NOT SCALE DRAWING

US - ReturnPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 7 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

MAXIMUM: 1828 mm [72 in]

SINGLE STAIR RAILING SECTIONMULTIPLE STAIR RAILING SECTIONS

MAXIM

UM: 1574 m

m [62 in]

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:20

RailBlazers® - Allowable Stair Spans

Report assembly P4 Stair Span

DO NOT SCALE DRAWING

Report assembly - stair span singlePART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 8 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

28 mm (1-3/32 in)

2- 7.2 mm

(9/32 in)

UNIVERSAL CONNECTORHORIZONTAL INSTALLATION

SKU: 10900, 10901

MOUNTINGTEMPLATE:

27.5 mm (1-3/32 in)

2-9.5 mm (3/8 in)

24 mm(15/16 in) 2-

9.5 mm (3/8 in)

63.2 mm (2-1/2 in)

38 mm (1-1/2 in)

MOUNTINGTEMPLATE:

WALL MOUNT BRACKETSSKU: 10920, 10921

UNIVERSAL CONNECTORVERTICAL INSTALLATION

SKU: 10900, 10901

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:2

RailBlazers® - Railing Brackets and Connectors

Report-brackets RB-CAN

DO NOT SCALE DRAWING

fig-ubrackets-horizPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 9 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

CORNER FASCIA MOUNT BRACKETSKU: 10960, 10961

LEFT MOUNTINGTEMPLATE:

72 m

m(2

-27/

32 in

) 6- 11.5 mm (7/16 in)

33 mm (1-5/16 in) 33 mm (1-5/16 in)

112 mm(4-13/32 in)

112

mm

(4-1

3/32

in)

MID/STAIR/END FASCIA MOUNT BRACKETSKU: 10970, 10971

MOUNTINGTEMPLATE:

20 mm (25/32 in)

82 m

m (3

-7/3

2 in

)

30 m

m (1

-3/1

6 in

)

4- 11.5 mm(7/16 in)

95 mm (3-3/4 in)

15 m

m (1

9/32

in)

97 m

m (3

-13/

16 in

)

RIGHT MOUNTINGTEMPLATE:

4- 11.5 mm (7/16 in)95 mm (3-3/4 in)

20 mm (25/32 in)

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:3

RailBlazers® - Railing Fascia Mount Brackets

Report-brackets RB-CAN

DO NOT SCALE DRAWING

fig-fascia-cornerPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 10 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA

CORNER POSTEND POST MID POST STAIR POST

102

mm

(4 in

)

4 x 9.25 mm (11/32 in)

102 mm (4 in)

78 mm (3-1/16 in)

78

mm

(3-1

/16

in)

12 mm (1/2 in)

12

mm

(1/2

in)

MOUNTINGTEMPLATE

21.

5 m

m (2

7/32

in)

DESCRIPTION SKUEnd Post 10000, 10001Mid Post 10010, 10011

Corner Post 10020, 10021Stair Post 10050, 10051

DIMENSIONS ARE IN MM UNLESS NOTED

TITLE

SIZE

BDWG. NO.

SCALE: 1:8

RailBlazers® Railing Posts

Report-posts RB-CAN

DO NOT SCALE DRAWING

fig-post-corner PABPART FILE

SHT REV2016-06-01-A

DWG REV A

THIS DRAWING AND ITS CONTENTS ARE PROPERTY OF THE ISSUING PEAK COMPANY (INCLUDING PEAK INNOVATIONS INC. AND PEAK PRODUCTS CORPORATION). ANY DISSEMINATION OR REPRODUCTION IN WHOLE OR IN PART IS STRICTLY PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Compliance with Canadian Building Codes Part 4 RAILBLAZERS® Aluminum Railing System Page 11 Appendix B - Assembly Drawings RJC No. VAN.106169.0014 CANADA