- home - mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · i. northern lights...

29

Upload: trandat

Post on 15-Nov-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural
Page 2: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural
Page 3: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

I. Northern Lights Marine Generators & Sound Enclosures 2

II. Northern Lights Marine Generator Options & Accessories 9

III. Northern Lights C-Series Generators 10

IV. Northern Lights Land-Based Generators 12

V. Lugger Marine Diesel Engines 15

VI. Hybrid Marine Systems 18

VI.Technicold Marine Air Conditioning & Refrigeration Systems 19

VII. Footnotes 23

The specifi cations in this document are subject to change without notice. Please note that dimensions and weights of generators are affected by optional equipment, AC output, phase (three phase or single phase may be options) and cooling confi gurations. Specifi cations of diesel propulsion engines are similarly affected by options and other factors. Please contact the factory for special applications and derating factors.

www.northern-lights.com

Contact factory for installation drawings.Northern Lights® generators, Lugger® marine engines, and Technicold® marine

systems are manufactured by Northern Lights, Inc.

4420 14th Avenue Northwest • Seattle, WA 98107-4616Tel: (206) 789-3880 • (800) 762-0165 • Fax: (206) 782-5455

Web: www.northern-lights.com • E-mail: [email protected]

Northern Lights, Technicold and Lugger are registered trademarks ofNorthern Lights Incorporated ©2013

Information, specifi cations, materials, and dimensions subject to change without notice.©2013 All Rights Reserved. Litho in USA. L605

TABLE OF CONTENTS

1

Page 4: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

MARINE GENERATORS

Marine Power Generation

Northern Lights manufactures acomprehensive line of 50 and 60 Hz marine generator sets from 4.5 to 250 kW. Powered by rugged Lugger diesels and proven in commercial fi shing boats, high-performance yachts and passenger vessels, Northern Lights generators provide unmatched quality and reliability.

Experienced engineering and meticulous craftsmanship go into every Northern Lights generator set. Our hand-wound skewed stator makes electricity with a symmetrical sine wave for today’s sensitive electronic equipment. All 60 Hz Northern Lights generator sets are compliant with current US EPA regulations, ensuring clean, reliable power production. Larger Northern Lights generator sets are manufactured with features like electronic control units and high-pressure common rail fuel injection.

M773LW3 7 - 9 kW

Marine Pow

er Generation M844LW3 16 - 20 kW

2

Page 5: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

MARINE GENERATORS

Sound EnclosuresEngineered for SilenceNorthern Lights’ industry-leading sound enclosures deliver exceptionally quiet operation. Dual sound-dampening barriers ensure optimum sound absorption. Advanced damper-sheet-coated internal air ducting keeps your generator quiet and cool - even in the warmest environments. To allow for quick and easy maintenance, the enclosures are equipped with stainless steel paddle latches. The advanced construction features rigid, powder-coated aluminum or electro-galvanized steel, making the enclosure extraordinarily robust, resistant to corrosion, and handsomeenough to complement any engine room. Reward yourself with a Northern Lights sound enclosure, and you’ll understand why Northern Lights continuously raises marine generator standards.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M673LD3 (1, 2)

5 kW4.5 kW3 inline2.64 in (67 mm)2.83 in (72 mm)46.4 cid (0.76 ltr)MechanicalNatural28.5 in (724 mm)19.5 in (495 mm)20.1 in (510 mm)377 lbs (171 kg)

M673L3 (1, 2)

6 kW5 kW3 inline2.64 in (67 mm)2.83 in (72 mm)46.4 cid (0.76 ltr)MechanicalNatural28.5 in (724 mm)19.5 in (495 mm)20.1 in (510 mm)377 lbs (171 kg)

• Secure, easy to reach latches on top and front. Stainless steel paddle latch on service side.• Interior latches on non-service sides improve aesthetics.• Multiple layers of fi rm and fl exible sound dampening materials absorb all frequency noise.• Protective fi lm coating ensures safety and longevity.• Fuel and oil drains outside of the sound enclosure for easy connection.• Front exhaust exit option.• Tough, white, powder-coat fi nish.• External exhaust connection on M773LW3 & M843NW3

Northern Lights’ revolutionary sound enclosure shares a base frame with the generator set, creating a compact power and sound attenuation package.

M673LD3, L3 Sound Shield28.5 in (724 mm)19.5 in (495 mm)20.8 in (528 mm)44 lbs (20 kg)05-78010

Length:Width:

Height:Weight:Part #:

Revolutionary design integrates base frame with enclosure

M673L3 6 - 5 kW

3

(shown with optional sound enclosure)

Page 6: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M773LW3 (1, 2)

9 kW7 kW3 inline3.03 in (77 mm)3.19 in (81 mm)69 cid (1.13 ltr)MechanicalNatural35.0 in (889 mm)22.0 in (559 mm)23.8 in (604 mm)537 lbs (244 kg)

M844W3 (1, 2)

16 kW12 kW4 inline3.3 in (84 mm)3.5 in (90 mm)121 cid (1.9 ltr)MechanicalNatural46.0 in (1169 mm)22.8 in (580 mm)26.7 in (680 mm)897 lbs (397 kg)

M843NW3 (1, 2)

12 kW10 kW3 inline3.3 in (84 mm)3.5 in (90 mm)91 cid (1.5 ltr)MechanicalNatural39.4 in (1000 mm)22.8 in (580 mm)25.2 in (641 mm)837 lbs (380 kg)

M844LW3 (1, 2)

20 kW16 kW4 inline3.3 in (84 mm)3.9 in (100 mm)135 cid (2.2 ltr)MechanicalNatural46.0 in (1169 mm)22.8 in (580 mm)27.5 in (697 mm)973 lbs (441 kg)

M773LW3 Sound Shield

M844W3 Sound Shield

M843NW3 Sound Shield

M844LW3 Sound Shield

35.0 in (889 mm)22.0 in (559 mm)24.2 in (614 mm)60 lbs (27 kg)05-78610

46.0 in (1169 mm)22.8 in (580 mm)28.1 in (714 mm)79 lbs (35 kg)05-70000

39.4 in (1000 mm)22.8 in (580 mm)25.7 in (654 mm)75 lbs (34 kg)05-73110

46.0 in (1169 mm)22.8 in (580 mm)28.1 in (714 mm)125.0 lbs (57 kg)05-70010

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

4

MARINE GENERATORS

Page 7: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M864W3 (1, 2)

25 kW20 kW4 inline3.4 in (86 mm)4.2 in (107 mm)152 cid (2.49 ltr)MechanicalNatural52.9 in (1350 mm)24.2 in (696 mm)26.5 in (672 mm)993 lbs (450 kg)

M944T

38 kW32 kW4 inline3.7 in (94 mm)4.7 in (120 mm)203 cid (3.33 ltr)MechanicalTurbocharged60.0 in (1524 mm)29.0 in (737 mm)30.5 in (775 mm)1416 lbs (642 kg)

M944W3 (1, 2)

30 kW26 kW4 inline3.7 in (94 mm)4.7 in (120 mm)203 cid (3.33 ltr)MechanicalNatural56.0 in (1422 mm)29.0 in (737 mm)30.7 in (779 mm)1351 lbs (604 kg)

M864W3 Sound Shield

M944T Sound Shield

M944W3 Sound Shield

52.9 in (1350 mm)24.2 in (696 mm)27.7 in (703 mm)140 lbs (64 kg)05-78705

60.0 in (1524 mm)29.0 in (737 mm)32.0 in (813 mm)140 lbs (64 kg)05-71220

56.0 in (1423 mm)29.0 in (737 mm)31.5 in (800 mm)158 lbs (72 kg)05-01200

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

M944T 38 - 32 kW(shown with optional sound enclosure and compound mounts)

5

MARINE GENERATORS

Page 8: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M1064D

40 kW33 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalNatural75.0 in (1905 mm)38.0 in (965 mm)38.4 in (975 mm)2513 lbs (1140 kg)

M1064A (3)

92 kW70 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)Electronic DE 10Turbo & Aftercooled77.2 in (1960 mm)38.0 in (965 mm)38.4 in (975 mm)2750 lbs (1248 kg)

M1064T1

55 kW50 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalTurbocharged75.0 in (1905 mm)38.0 in (965 mm)38.4 in (975 mm)2513 lbs (1140 kg)

M1064T2 (3)

65 kW55 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)Electronic DE10Turbocharged75.0 in (1905 mm)38.0 in (965 mm)38.4 in (975 mm)2603 lbs (1181 kg)

M1064H (3)

99 kW90 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)HPCRTurbo & Aftercooled77.2 in (1960 mm)38.0 in (965 mm)38.4 in (975 mm)2750 lbs (1248 kg)

M1064A, D, H, T1 & T2* Sound Shield

M1064A, D, H, T1 & T2* Sound Shield

75.0 in (1905 mm)38.0 in (965 mm)41.0 in (1041 mm)336 lbs (152 kg)05-79435 (M1064D)05-79455 (M1064T2, T1, A & H)05-79445 (M1064T1 & T2 3 phase)

80.9 in (2054 mm)41.3 in (1048 mm)46.6 in (1159 mm)336 lbs (152 kg)05-79430 (M1064D)05-79440 (M1064T1 & T2, 3ph)05-79450 (M1064T2 1ph, A & H 3 ph.)

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

6

* Narrow

* Wide - for use with InSep

MARINE GENERATORS

Page 9: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M1066T (3)

99 kW80 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)Electronic DE 10

TurbochargedConsult Factory38.0 in (965 mm)38.4 in (975 mm)Consult Factory

M1066A1 (3,5)

130 kW105 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)Electronic DE 10 @60 Hz

Electronic VP 44 @50 Hz

Turbo & Aftercooled90.0 in (2286 mm)42.0 in (1066 mm)39.3 in (998 mm)3541 lbs (1646 kg)

M1066A2 (3,5)

145 kW115 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)Electronic VP 44Turbo & Aftercooled90.0 in (2286 mm)42.0 in (1066 mm)39.3 in (998 mm)3630 lbs (1646 kg) @60 Hz

Consult Factory @50 Hz

M1066A3 (3,5)

160 kWn/a6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr) Electronic VP 44Turbo & Aftercooled90.0 in (2286 mm)42.0 in (1067 mm)39.3 in (998 mm)3734lbs (1694 kg) @60 Hz

consult factory @50 Hz

M1066T Sound Shield (4)

M1066A1, A2 & H Sound Shield (4)

Consult Factory38.0 in (965 mm)41.0 in (1041 mm)Consult Factory05-79645

90.0 in (2286 mm)42.0 in (1067 mm)42.0 in (1067 mm)436 lbs (198 kg)05-79650

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

7

M1066A3 Sound Shield (4)

M1066H Sound Shield (4)

90.0 in (2286 mm)42.0 in (1067 mm)42.0 in (1067 mm)436 lbs (198 kg)05-79650

90.0 in (2286 mm)42.0 in (1067 mm)42.0 in (1067 mm)436 lbs (198 kg)Consult Factory

Length:Width:

Height:Weight:Part #:

Length:Width:

Height:Weight:Part #:

MARINE GENERATORS

Page 10: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M1306A12 (3,5)

355 kW300 kW6 inline5.1 in (130 mm)6.3 in (160 mm)775 cid (12.7 ltr)High Pressure / ElectronicTurbo & Aftercooled111.0 in (2819 mm)42.0 in (1067 mm)47.1 in (1196 mm)6190 lbs (2808 kg)

M1306A22 (3,5)

400 kW350 kW6 inline5.1 in (130 mm)6.3 in (160 mm)775 cid (12.7 ltr)High Pressure / ElectronicTurbo & Aftercooled111.0 in (2819 mm)42.0 in (1067 mm)47.1 in (1196 mm)6190 lbs (2808 kg)

M1306A32 (3,5)

n/a400 kW6 inline5.1 in (130 mm)6.3 in (160 mm)775 cid (12.7 ltr)High Pressure / ElectronicTurbo & Aftercooled111.0 in (2819 mm)42.0 in (1067 mm)47.1 in (1196 mm)6560 lbs (2976 kg)

8

M1066H (Shown with optional sound enclosure) 185 - 155 kW

M1066H3(3,5)

185 kW155 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)HPCRTurbo & Aftercooled90.0 in (2286 mm)42.0 in (1067 mm)39.3 in (998 mm)3776 lbs (1713 kg)

MARINE GENERATORS

M1306A12, 22, 32 Sound Shield (4) 111.0 in (2819 mm)42.0 in (1067 mm)49.5 in (1257 mm)600 lbs (272 kg)

Length:Width:

Height:Weight:

Page 11: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M1066TR (6)

99 kW80 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)Electronic DE10Turbocharged94.1 in (2390 mm)34.2 in (868 mm)44.9 in (1140 mm)2910 lbs (1320 kg) @60 Hz

MCA Compliant Emergency Generator Sets

Consult factory for more information on Options & Accessories.

Mar

ine

Gene

rato

r Opt

ions

& A

cces

sori

es

9

M1064DR (6)

36 kW33 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalNatural64.0 in (1626 mm)31.0 in (787 mm)40.2 in (1021 mm)1900 lbs (862 kg)

M944WR3 (6)

c/f24 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)Electronic DE10Turbochargedtbdtbdtbdtbd

Compound MountsIn addition to the industry’s best vibration mounts supplied as a standard

feature, Northern Lights offers optional Compound Mounts to minimize

generator set vibration. Optimal attenuation is achieved by using

MARINE GENERATORS

industrial grade rubber and galvanized steel - components tough enough

for the marine environment.

Fitting beneath the base frame,

Northern Lights’ Compound Mounts

add only centimeters to the height of the

generator set, ensuring engine room space is

not sacrifi ced for attenuation.

Page 12: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

Marine Pow

er Generation C-Series

C-SERIES MARINE GENERATORS

C-Series Power for Commercial ChallengesNorthern Lights’ C-Series generator sets are designed for tough commercial applications. These generators deliver the rugged durability, long-life dependability and the peace of mind that comes with owning a Northern Lights.

60 Hz/1800 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M30CW3 (7)

30 kW4 inline3.7 in (94 mm)4.7 in (120 mm)203 cid (3.3 ltr)MechanicalNatural51.9 in (1319 mm)24.8 in (630 mm)30.9 in (785 mm)1182 lbs (536 kg)

M38CR3 (7)

38 kW4 inline3.7 in (94 mm)4.7 in (120 mm)203 cid (3.3 ltr)MechanicalNatural60.1 in (1527 mm)24.9 in (633 mm)30.9 in (785 mm)1361 lbs (617 kg)

10

M30CW3 30 kW

M40C2 (7)

40 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalNatural64.3 in (1633 mm)27.5 in (699 mm)37.5 in (953 mm)1993 lbs (904 kg)

60 Hz/1800 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M20CRW3 (7)

20 kW4 inline3.3 in (84 mm)3.9 in (100 mm)135 cid (2.2 ltr)MechanicalNatural43.2 in (1098 mm)20.7 in (526 mm)32.8 in (833 mm)820 lbs (372 kg)

Page 13: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

C-SERIES MARINE GENERATORS

60 Hz/1800 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

M99C2 (7)

99 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)Electronic DE 10Turbocharged82.5 in (2096 mm)27.5 in (699 mm)39.3 in (999 mm)2500 lbs (1134 kg)

M55C2 (7)

55 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalTurbocharged67.8 in (1723 mm)27.5 in (699 mm)37.5 in (953 mm)1965 lbs (891 kg)

M150C12 (7)

150 kW6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)HPCRTurbo & Aftercooled82.7 in (2100 mm)33.8 in (858 mm)41.6 in (1056 mm)3550 lbs (1610 kg)

M200C12 (7)

200 kW6 inline4.6 in (118 mm)5 in (127 mm)549 cid (9.0 ltr)HPCRTurbo & Aftercooled97.5 in (2745 mm)37.3 in (947 mm)45.5 in (1156 mm)4263 lbs (1935 kg)

M65C2 (7)

65 kW4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)Electronic DE 10Turbocharged69.6 in (1769 mm)27.5 in (699 mm)37.5 in (953 mm)2075 lbs (941 kg)

Standard Features• Molded belt guard (20 - 99 kW)• Welded steel base frame• Service side lube oil fi lter• 20 and 38 kW units feature generator reconnectable for 3 or single phase.

• Brushless, continuous duty generator end.• 12 Volt starter placed high and dry.• Center bonded vibration isolation mounts.

M250C12 (7)

250 kW6 inline4.6 in (118 mm)5 in (127 mm)549 cid (9.0 ltr)HPCRTurbo & Aftercooled102.5 in (2604 mm)36.0 in (914 mm)44.8 in (1138 mm)4640 lbs (2104 kg)

11

Page 14: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

LAND-BASED GENERATORS

60 Hz/1800 rpm:50 Hz/1800 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

NL673L4 (8)

6 kW5 kW3 inline2.64 in (67 mm)2.83 in (72 mm)46.4 cid (0.761 ltr)MechanicalNatural32.8 in (834 mm)15.4 in (390 mm)25.6 in (651 mm)374 lbs (169 kg)

NL773LW4 (8)

9 kW7 kW3 inline3.03 in (77 mm)3.19 in (81 mm)69 cid (1.13 ltr)MechanicalNatural37.9 in (965 mm)19.0 in (483 mm)31.4 in (798 mm)539 lbs (244 kg)

NL843NW4 (8)

12 kW10 kW3 inline3.3 in (84 mm)3.5 in (90 mm)91 cid (1.5 ltr)MechanicalNatural45.7 in (1160 mm)18.1 in (461 mm)33.1 in (841 mm)753 lbs (341 kg)

Land-Based Power GenerationNorthern Lights manufactures a comprehensive line of prime and stand-by diesel industrial generators from 5 kW to 400 kW. Fifty years ago, Northern Lights generators were developed to provide life-sustaining power in the Alaskan wilderness. They became renowned for outstanding reliability in schools, villages and during pipeline construction.

Today, Northern Lights handles the tough-est challenges for prime and stand-by power.

Land-Based Power Generation

44TIERI

T

NL673L4 5 - 6 kWNorthern Lights generator sets up to 20 kW are Tier IV approved,

and all land based units are US EPA compliant ensuring clean, reliable production. No matter whether on a job site, a hunting camp, or a remote telecommunications station, Northern Lights offers the superior engineering and technical precision to bring you reliable power.

Project-tailored designs and special fabrication options are available for power modules, trailer units and more.

12

Page 15: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

LAND-BASED GENERATORS

13

60 Hz/1800 rpm:

50 Hz/1500 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:50 Hz/1500 rpm:

Cylinders:Bore:

Stroke:Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

NL944T3 (8)

36 kW

32 kW4 inline3.7 in (94 mm)4.72 in (120 mm)203 cid (3.33 ltr)MechanicalTurbocharged64.8 in (1647 mm)25.6 in (650 mm)35.8 in (909 mm)1390 lbs (630 kg)

NL1064T23 (9)

50 kW - prime54 kW - standbyn/a4 inline4.2 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)MechanicalTurbocharged77.5 in (1968 mm)28.0 in (711 mm)57.0 in (1447 mm)1958 lbs (888 kg)

NL844LW4 (8)

20 kW16 kW4 inline3.3 in (84 mm)3.9 in (100 mm)135 cid (2.213 ltr)MechanicalNatural53.2 in (1350 mm)21.7 in (552 mm)34.2 in (869 mm)960 lbs (435 kg)

NL1064H23 (9)

75 kW - prime85 kW - standbyn/a4 inline4.2 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)HPCRTurbo & Aftercooled85.6 in (2174 mm)30.5 in (775 mm)52.2 in (1325 mm)2846 lbs (1291 kg)

NL944D3 (8)

28 kW24 kW4 inline3.7 in (94 mm)4.72 in (120 mm)203 cid (3.33 ltr)MechanicalNatural64.8 in (1647 mm)25.6 in (650 mm)35.7 in (907 mm)1316 lbs (597 kg)

NL773LW4 9 - 7 kW

Page 16: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

60 Hz/1800 rpm:

50 Hz/1500 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

60 Hz/1800 rpm:

50 Hz/1500 rpm:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:Length:Width:

Height:Weight:

NL1066H33 (9, 10)

180 kW - prime200 kW - standbyn/a6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)HPCRTurbo & Aftercooled112.7 in (2851 mm)50.5 in (1285 mm)66.2 in (1682 mm)4106 lbs (1862 kg)

NL1064H33 (9)

90 kW - prime100 kW - standbyn/a4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)HPCRTurbo & Aftercooled85.6 in (2174 mm)30.5 in (775 mm)52.2 in (1325 mm)2900 lbs (1315 kg)

NL1186H43 (9, 10)

250 kW - prime275 kW - standbyn/a6 inline4.66 in (118 mm)5.35 in (136 mm)548 cid (9.0 ltr)HPCRTurbo & Aftercooled116.0 in (2946 mm)48.0 in (1219 mm)64.7 in (1643 mm)4980 lbs (2259 kg)

NL1064H43 (9)

110 kW - prime125 kW - standbyn/a4 inline4.19 in (106 mm)5 in (127 mm)276 cid (4.5 ltr)HPCRTurbo & Aftercooled85.6 in (2174 mm)30.5 in (775 mm)53.6 in (1361 mm)3016 lbs (1368 kg)

NL1326H (10)

360 kW - prime400 kW - standbyn/a6 inline5.2 in (132 mm)6.5 in (165 mm)824 cid (13.5 ltr)Electronic Unit InjectionTurbo & AftercooledConsult FactoryConsult FactoryConsult FactoryConsult Factory

NL1066H23 (9,10)

135 kW - prime150 kW - standbyn/a6 inline4.19 in (106 mm)5 in (127 mm)414 cid (6.8 ltr)HPCRTurbo & Aftercooled102.2 in (2595 mm)40.1 in (1019 mm)54.7 in (1389 mm)3385 lbs (1535 kg)

LAND-BASED GENERATORS

14

Page 17: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

The Diesel Tough Enough to Go the Distance

L1066A 250 - 185 Hp (shown with optional gear.)

Northern Lights builds anvil-tough Lugger marine diesels from 40 to 470 HP.

Originally designed for the uninterrupted operation necessary on commercial

vessels, Lugger engines are recognized worldwide for performance, fuel

effi ciency and long-life dependability.

All Lugger marine diesel engines feature

impressive torque curves. Their fl awless

performance is the result of fi ve decades of

marinization expertise coupled with

meticulous craftsmanship. Luggers are fully

customizable to provide the optimal match

at propulsion and vessel.

A comprehensive list of standard features makes Lugger engines

rugged enough for commercial craft, yet sophisticated enough for

high-performance yachts. For easy installation, economical maintenance

and long engine life, features such as in-line design, mechanical seals and

seawater-cooled aftercoolers make Lugger an obvious choice.

Today, fi shing boats, work boats, passenger

ferries, yachts and even circumnavigating

long-range cruisers all rely on the

dependability and low operating costs

offered by Lugger engines.

15

MARINE PROPULSION ENGINES

Lugg

er M

arin

e Pr

opul

sion

Eng

ines

L844D 40 Hp

Page 18: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

MARINE PROPULSION ENGINES

High Output:Medium Duty:

Continuous Duty:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:SAE Housing:

Length:Width:

Height:Weight:

(without gear):

High Output:Medium Duty:

Continuous Duty:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:SAE Housing:

Length:Width:

Height:Weight:

(without gear):

L844D40 kW40 HP @ 2800 rpmn/an/a4 inline3.3 in (84 mm)3.5 in (89 mm)121 cid (1.9 ltr)MechanicalNatural#427.2 in (691 mm)19.8 in (502 mm)26.9 in (683 mm)K.C. 574 lbs (260 kg)H.E. 587 lbs (266 kg)

L1064A40 kW140 HP @ 2400 rpm125 HP @ 2200 rpm115 HP @ 2000 rpm4 inline4.19 in (106 mm)5.0 in (127 mm)276 cid (4.5 ltr)Electronic DE 10Turbo & Aftercooled#445.0 in (1143 mm)29.4 in (747 mm)36.0 in (913 mm)K.C. 1250 lbs (567 kg)H.E. n/a L1066T (3)40 kW

170 HP @ 2500 rpm165 HP @ 2400 rpm135 HP @ 2200 rpm6 inline4.19 in (106 mm)5.0 in (127 mm)414 cid (6.8 ltr)Electronic DE 10Turbocharged#254.9 in (1396 mm)27.3 in (693 mm)36.2 in (919 mm)K.C. - 1960 lbs (889 kg)H.E. - 1982 lbs (899 kg)

L1064T140 kWn/an/a100 HP @ 2500 rpm4 inline4.19 in (106 mm)5.0 in (127 mm)276 cid (4.5 ltr)MechanicalTurbocharged#440.5 in (1028 mm)32.7 in (830 mm)35.9 in (911 mm)K.C. 1190 lbs (540 kg) H.E. 1160 lbs (526 kg)

L1066A (3) 40 kW250 HP @ 2400 rpm200 HP @ 2200 rpm185 HP @ 2400 rpm6 inline4.19 in (106 mm)5.0 in (127 mm)414 cid (6.8 ltr)Electronic VP 44Turbo & Aftercooled#256.6 in (1439 mm)29.7 in (753 mm)37.3 in (948 mm)K.C. - n/aH.E. - 2155 lbs (977 kg)

16

L1066H (3) 40 275 275 HP @ 2400 rpm250 HP @ 2200 rpmn/a6 inline4.19 in (106 mm)5.0 in (127 mm)414 cid (6.8 ltr)HPCRTurbo & Aftercooled#255.6 in (1412 mm)28.9 in (734 mm)37.3 in (947 mm)K.C. - n/aH.E. - 2162 lbs (981 kg)

Page 19: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

L6125H 350 - 470 Hp

MARINE PROPULSION ENGINES

17

High Output:Medium Duty:

Continuous Duty:Cylinders:

Bore:Stroke:

Displacement:Fuel System:

Aspiration:SAE Housing:

Length:Width:

Height:Weight:

(without gear):

L6125H40 kW470 HP @ 2300 rpm440 HP @ 2200 rpm350 HP @ 1800 rpm6 inline4.9 in (125 mm)5.9 in (150 mm)674 cid (11 ltr)HPCRTurbo & Aftercooled#169.0 in (1758 mm)33.0 in (840 mm)45.0 in (1143 mm)K.C. - tbaH.E. - 2867 lbs (1300 kg)

Notes:

Length: Measured from the face of the fl ywheel housing to the frontmost point of the engine.

Rating Defi nitions:Following are defi nitions of duty ratings for Luggers. Please contact your Lugger representative to verify your application.

High Output:Based on a load factor of 20% or less. A maximum of fi ve minutes at full throttle, followed by not less than ten minutes at cruise power or below. For applications up to 200 total hours per year

Medium Duty:Based on a load factor of 66% or less. A maximum of two hours at full throttle, followed by at least one hour at cruise power or below. For applications up to 4000 total hours per year.

Continuous Duty:Based on a load factor of 100%. No limit on time at full throttle. No limit on hours per year.

Page 20: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

18

Hybrid Marine System

MARINE SYSTEMS

Northern Lights Hybrid Marine System provides clean, reliable power with world class components. Based on a tested, reliable Lugger propulsion engine and a traction generator, energy is held in a series of battery packs and metered through a power control system. The traction motor provides power to the prop, while energy is stored for its most effi cient usage.

Available in 3 phase, 60 or 50 Hertz confi gurations, the amount of power produced and stored can be customized to fi t your vessel’s requirements.

The entire package is designed to be clean, quiet, environmentally responsible and will reduce both energy waste and fuel costs as soon as its installed.

Visit www.northern-lights.com/hybrid for specifi cations.

Page 21: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

MARINE SYSTEMS

Tech

nico

ld A

ir C

ondi

tion

ing

& R

efri

gera

tion

19

Customized Options Available. Contact factory for details

Technicold by Northern Lights is recognized as the industry leader in marine air conditioning, refrigeration and refrigerated seawater systems.

Technicold marine cooling systems have earned their reputation as the industry’s best. Technicold offers a comprehensive line of chilled water air conditioners from 24,000 to 120,000 BTU and a line of direct expansion systems from 8,000 to 32,000 BTU. In addition to a wide range of “Plug and Play” systems that are ready to install, Technicold offers cooling and refrigeration systems for virtually any application.

Stackable and fully customizable, Technicold can provide the cooling solution for your yacht, trawler or commercial application.

Direct Expansion Condensing Unit and Evaporator

Page 22: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

CHILLED WATER SYSTEMS

Capacity:Draw (230V/1ph):Draw (208V/3ph):

Height:Width:Depth:

Weight:

CW24C 40 275 HP 24,000 BTU6.8 amps5.4 amps16.0 in (406 mm)13.5 in (343 mm)26.5 in (673 mm)151 lbs (68 kg)

CW30C 40 275 HP 30,000 BTU8.4 amps6.3 amps16.0 in (406 mm)13.5 in (343 mm)26.5 in (673 mm)164 lbs (74 kg)

CW36C 40 275 HP 36,000 BTU14.0 amps9.5 amps16.8 in (425 mm)13.5 in (343 mm)26.5 in (673 mm)170 lbs (77 kg)

Capacity:Draw (230V/1ph):Draw (208V/3ph):

Height:Width:Depth:

Weight:

CW48C 40 275 HP 48,000 BTU13.3 amps9.0 amps18.0 in (457 mm)14.5 in (368 mm)26.5 in (673 mm)181 lbs (82 kg)

CW60C 40 275 HP 60,000 BTU22.0 amps12.4 amps18.8 in (476 mm)14.5 in (368 mm)26.5 in (673 mm)187 lbs (84 kg)

CW72C 40 275 HP 72,000 BTUn/a14.2 amps23.0 in (584 mm)14.5 in (368 mm)26.5 in (673 mm)194 lbs (88 kg)

Capacity:Draw (230V/1ph):Draw (208V/3ph):

Height:Width:Depth:

Weight:

CW180C 40 275 180,000 BTUConsult FactoryConsult Factory53.0 in (1353 mm)24.5 in (622 mm)18.0 in (457 mm)Consult Factory

Chilled Water Air Conditioner

20

CW120C 40 275 120,000 BTUn/a19.8 amps24.8 in (629 mm)14.5 in (368 mm)34.0 in (864 mm)304 lbs (137 kg)

Page 23: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

RA0808,000 BTU2651.9 amps0.9 amps9.0 in (229 mm)17.0 in (432 mm)14.0 in (356 mm)19 lbs (8 kg)

RA18418,000 BTU5003.6 amps1.7 amps12.0 in (305 mm)19.0 in (483 mm)17.6 in (447 mm)33 lbs (15 kg)

RA12 412,000 BTU3503.2 amps1.6 amps12.0 in (305 mm)18.5 in (470 mm)15.0 in (381 mm)27 lbs (12 kg)

RA24424,000 BTU7006.4 amps3.2 amps12.0 in (305 mm)35.0 in (889 mm)13.5 in (394 mm)51 lbs (23 kg)

RA16 416,000 BTU5003.6 amps1.7 amps12.0 in (305 mm)18.5 in (470 mm)17.0 in (432 mm)28 lbs (12 kg)

RA32

32,000 BTU1,0007.1 amps3.4 amps12.0 in (305 mm)35.0 in (889 mm)17.0 in (432 mm)55 lbs (25 kg)

Capacity:CFM

Draw (115V/1ph):Draw (230V/1ph):

Height:Width:Depth:

Weight:

Capacity:CFM

Draw (115V/1ph):Draw (230V/1ph):

Height:Width:Depth:

Weight:

Chilled Water Air Handler RA16

Chilled Water Air Handler Double Blowers RA24

CHILLED WATER AIR HANDLERS

21

Page 24: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

22

Direct Expansion Condensing Unit

DIRECT EXPANSION AIR CONDITIONING

Capacity:Draw (115V):Draw (230V):

Height:Width:Depth:

Weight:

RC08 (11) 40 275 8,000 BTU8.9 amps4.4 amps15.0 in (381 mm)14.0 in (343 mm)10.0 in (254 mm)59 lbs (26 kg)

RC12 (11)40 275 12,000 BTU11.0 amps5.9 amps15.0 in (381 mm)14.0 in (343 mm)10.0 in (254 mm)64 lbs (29 kg)

RC16 (11) 40 275 16,000 BTU15.0 amps6.2 amps15.0 in (381 mm)14.0 in (343 mm)10.0 in (254 mm)66 lbs (30 kg)

Capacity:Draw (115V):Draw (230V):

Height:Width:Depth:

Weight:

RC24 (11) 40 275 24,000 BTUn/a12.0 amps17.0 in (432 mm)16.0 in (406 mm)13.0 in (330 mm)120 lbs (54 kg)

RC32 (11) 40 275 32,000 BTUn/a16.5 amps17.0 in (432 mm)17.0 in (432 mm)13.0 in (330 mm)128 lbs (58 kg)

Capacity:Draw (115V):Draw (230V):

Height:Width:Depth:

Weight:

RC40 (11) 40 275 40,000 BTUn/a22.5 amps17.0 in (432 mm)18.0 in (457 mm)13.0 in (330 mm)130 lbs (59 kg)

RC48 (11) 0 275 48,000 BTUn/a22.7 amps17.0 in (432 mm) 20.0 in (508 mm)13.0 in (330 mm)149 lbs (67 kg)

RC60 (11) 40 275 60,000 BTUn/a26.0 amps17.0 in (432 mm)21.0 in (533 mm)13.0 in (330 mm)152 lbs (69 kg)

Page 25: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

23

DIRECT EXPANSION EVAPORATORS

RE088,000 BTU2651.9 amps0.9 amps9.5 in (241 mm)13.0 in (330 mm)13.0 in (330 mm)19 lbs (8 kg)

RE066,000 BTU2651.9 amps0.9 amps9.5 in (241 mm)13.0 in (330 mm)13.0 in (3330 mm)18 lbs (8 kg)

RE1818,000 BTU5003.6 amps1.7 amps12.0 in (305 mm)15.0 in (381 mm)16.0 in (406 mm)27.0 lbs (12 kg)

RE1212,000 BTU3503.2 amps1.6 amps12.0 in (305 mm)15.0 in (381 mm)14.0 in (356 mm)25 lbs (11 kg)

RE2424,000 BTU7006.4 amps3.2 amps12.0 in (305 mm)32.0 in (813 mm)14.0 in (356 mm)51 lbs (23 kg)

RE1616,000 BTU5003.6 amps1.7 amps12.0 in (305 mm)15.0 in (381 mm)16.0 in (406 mm)27 lbs (12 kg)

RE32 32,000 BTU1,0007.1 amps3.4 amps12.0 in (305 mm)32.0 in (813 mm)15.5 in (394 mm)55 lbs (25 kg)

Capacity:CFM

Draw (115V/1ph):Draw (230V/1ph):

Height:Width:Depth:

Weight:

Capacity:CFM

Draw (115V/1ph):Draw (230V/1ph):

Height:Width:Depth:

Weight:

Capacity:CFM

Draw (115V/1ph):Draw (230V/1ph):

Height:Width:Depth:

Weight:

Customized Options Available. Contact factory for details

Direct Expansion Evaporator

Page 26: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

REFRIGERATION CONDENSING UNITS, SELF CONTAINED AIR CONDITIONING, & FRESH AIR MAKE-UP

Type:Capacity:

Height:Width:Depth:

Weight:

SC12C 40 275 Cool Only12,000 BTU12.0 in (343 mm)12.0 in (343 mm)24.0 in (609 mm)81 lbs (36 kg)

Type:Capacity:

Height:Width:Depth:

Weight:

Refrigerator Condensing UnitsRB050W9314.5 in (368 mm)13.5 in (343 mm)12.5 in (317 mm)73 lbs (33 kg)

Draw (110V):Draw (220V):

Height:Width:Depth:

Weight:

RB075W0124.514.5 in (368 mm)13.5 in (343 mm)13.5 in (343 mm)95 lbs (43 kg)

Fresh Air Make-Up

MA500VB (12)

50023012.3 in (312 mm)19.2 in (488 mm)19.3 in (490 mm)48 lbs (21 kg) (13)

MA1000VB (12)

100023012.3 in (312 mm)35.2 in (894 mm)15.0 in (401 mm)71 lbs (32 kg) (13)

CFM:VAC:

Height:Width:Depth:

Weight:

Self Contained Air Conditioning

24

Self Contained Air Conditioner

SC12CH40 275 With Heat12,000 BTU12.0 in (343 mm)12.0 in (343 mm)26.0 in (660 mm)82 lbs (37 kg)

SC16C 40 275 Cool Only16,000 BTU12.0 in (343 mm)12.0 in (343 mm)26.0 in (660 mm)85 lbs (38 kg)

SC16CH 40 275 With Heat16,000 BTU12.0 in (343 mm)12.0 in (343 mm)26.0 in (660 mm)86 lbs (39 kg)

Page 27: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

Information, specifi cations, materials and dimensions subject to change without notice.

FOOTNOTES

Footnotes:

1. Prime kW rating based on SAE J-1995 and ISO 3046. Single-phase, 1.0 power factor.2. Lloyd’s Register of Shipping Type Approved.3. Features electronic fuel injection and an electronic control unit (ECU).4. Classed sound enclosure available. Inquire with factory.5. Prime kW rating for standard three-phase generators at 0.8 power factor. Dimensional data is for units with hydrolastic mounts, heat exchanger cooling, and three-phase generator ends with PMG. Consult factory for dimensions on single phase and additional options.6. Radiator Cooled; MCA Compliant.7. Prime kW ratings for standard three-phase generators at 0.8 power factor. Dimensional information is based on standard 1800 rpm, 60 Hz, three-phase generators with standard mounts.8. Ratings based on SAE J-1995 at 1.0 unity power factor.9. Ratings for three-phase units with 0.8 power factor.10. Tier 3 unit with limited application and availability in 2011 and beyond. Consult factory to see if interim Tier IV is required for your application.11. Dimensions given for reverse cycle units. Consult factory for cool-only and 3 phase equipment.12. Models shown are 60 Hz, single phase. Reduce CFM 17% for 50Hz models.13. Consult factory for weights and dimensions on units with optional heat strips.

Founded in 1958, Northern Lights is a global leader of marine and land-based systems, offering a comprehensive line of marine and land-based generator sets as well as propulsion engines, and the Technicold line of marine cooling products. Based in Seattle, Washington, USA, Northern Lights is dedicated to delivering reliability, durability, and simplicity. With a worldwide dealer network in over 40 countries, support is never far away.

25

Page 28: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural
Page 29: - Home - Mavexmavex.com/.../pdfs/marine-air-conditioning-northern-lights.pdf · I. Northern Lights Marine Generators & Sound Enclosures 2 ... 152 cid (2.49 ltr) Mechanical Natural

4420 14th Ave NWSeattle, WA 98107-4616Tel: 206-789-3880Fax: 206-782-5455Toll Free: 1-800-762-0165

WORLDWIDECORPORATE

HEADQUARTERS

1200 W Int’l Airport RoadAnchorage, AK 99519-0208Tel: 907-562-2222Fax: 907-563-1921Toll Free: 1-800-478-3006

ALASKAREGION

1419 W. Newport Center DriveDeerfield Beach, FL 33442-7709Tel: 954-421-1717Fax: 954-412-1712Toll Free: 1-800-843-6140

SOUTHEASTREGION

8 Connector RoadAndover, MA 01810-5904Tel: 978-475-7400Fax: 978-475-7745Toll Free: 1-800-480-4223

NORTHEASTREGION