As described in the One Tacoma Comprehensive Plan Qualies associated with single-family residenal designaons that are desirable include: low noise levels, limited traffic, large setbacks, private yards, small scale buildings, and low-density development. Community facilies, such as parks, schools, day cares, and religious facilies are also desirable components of residenal neighborhoods. Limited allowances for other types of residenal development are also provided for in the singe family designaon with addional review to ensure compability with the desired, overarching single-family character. In some instances, such as the HMR-SRD, areas designated for single family residenal development have an historic mix of residenal densies and housing types which should be maintained while allowing for connued expansion of housing opons consistent with the single family designaon. Target Development Density: 6–12 dwelling units/acre As described in the One Tacoma Comprehensive Plan This district enjoys many of the same qualies as single-family neighborhoods such as low traffic volumes and noise, larger setbacks, and small-scale development, while allowing for mul-family uses and increased density along with community facilies and instuons. The Mul-Family (low-density) district can oſten act as a transion between the single-family designaon and the greater density and higher intensity uses that can be found in the Mul-Family (high density designaon) or commercial or mixed use\designaons. This designaon is more transit-supporve than the Single Family Residenal areas and is appropriate along transit routes and within walking distance of transit staon areas. Target Development Density: 14–36 dwelling units/acre As described in the One Tacoma Comprehensive Plan This designaon allows for a wide range of residenal housing types at medium and higher density levels, along with community facilies and instuons, and some limited commercial uses and mixed-use buildings. It is characterized by taller buildings, higher traffic volumes, reduced setbacks, limited private yard space, and greater noise levels. These areas are generally found in the central city and along major transportaon corridors where there is increased access to public transportaon and to employment centers. Target Development Density: 45–75 dwelling units/acre Single-Family Zones Mul-family Zones (low-density) Mul-family Zones (high-density) RESIDENTIAL ZONES R1 R2, R2-SRD, HMR-SRD, R3, R4-L R4 R5 60’ 150’ 35’ T, C1 C2, PDB NCX CCX, RCX UCX,CIX HMX URX NRX NRX NRX DRAFT

Upload: others

Post on 30-Dec-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Zoning Reference Guide 2020 - Tacoma

As described in the One Tacoma Comprehensive Plan Qualities associated with single-family residential designations that are desirable include: low noise levels, limited traffic, large setbacks, private yards, small scale buildings, and low-density development. Community facilities, such as parks, schools, day cares, and religious facilities are also desirable components of residential neighborhoods. Limited allowances for other types of residential development are also provided for in the singe family designation with additional review to ensure compatibility with the desired, overarching single-family character. In some instances, such as the HMR-SRD, areas designated for single family residential development have an historic mix of residential densities and housing types which should be maintained while allowing for continued expansion of housing options consistent with the single family designation.

Target Development Density: 6–12 dwelling units/acre

As described in the One Tacoma Comprehensive Plan This district enjoys many of the same qualities as single-family neighborhoods such as low traffic volumes and noise, larger setbacks, and small-scale development, while allowing for multi-family uses and increased density along with community facilities and institutions. The Multi-Family (low-density) district can often act as a transition between the single-family designation and the greater density and higher intensity uses that can be found in the Multi-Family (high density designation) or commercial or mixed use\designations. This designation is more transit-supportive than the Single Family Residential areas and is appropriate along transit routes and within walking distance of transit station areas.

Target Development Density: 14–36 dwelling units/acre

As described in the One Tacoma Comprehensive Plan This designation allows for a wide range of residential housing types at medium and higher density levels, along with community facilities and institutions, and some limited commercial uses and mixed-use buildings. It is characterized by taller buildings, higher traffic volumes, reduced setbacks, limited private yard space, and greater noise levels. These areas are generally found in the central city and along major transportation corridors where there is increased access to public transportation and to employment centers.

Target Development Density: 45–75 dwelling units/acre

Single-Family Zones

Multi-family Zones (low-density)

Multi-family Zones (high-density)

RESIDENTIAL ZONESR1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

DRAFT

Page 2: Zoning Reference Guide 2020 - Tacoma

SINGLE-FAMILYZONING SUMMARY

Land-Use Diagrams

R-1 Building Envelope

35’

35’

25’

25’

25’

20’

5’

5’

5’

5’

Alley

Street

R-2 Building Envelope

R-1 Single-family District Zone DescriptionThe R-1 district is intended for a typical neighborhood with only single family dwelling units. It is most appropriate in established areas with a relatively quiet and stable neighborhood environment. The R-1 has low traffic volumes, larger lot sizes and may be part of a View Sensitive Overlay district. Left and above: large lot single-family homes typical of R-1

R-1 Single-Family TMC13.06.100… TMC13.06.100.C.5 7,5006,75050 4535257.525

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf) Min. Small Lot Area (sf) Min. Standard lot width (ft) Min. Small lot width (ft) Max. Height (ft) Setback Front (ft) Setback Side (ft) Setback Rear (ft)

R-2 Single Family DistrictZone DescriptionThe R-2 is the most common residential zoning district in the City. This district is intended for single-family detached housing. This district permits all uses allowed in an R-1 and may also allow for lodging uses limited to one guest room. It generally abuts more intense residential and commercial districts. Left and above: while large lots are still predominant, some infill of smaller more tightly clustered lots support a range of single-family dwellings

R-2 Single-FamilyTMC13.06.100...TMC13.06.100.C.55,0004,50050353520525

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf) Min. Small Lot Area (sf) Min. Standard lot width (ft) Min. Small lot width (ft) Max. Height (ft) Setback Front (ft) Setback Side (ft) Setback Rear (ft)

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

DRAFT

Page 3: Zoning Reference Guide 2020 - Tacoma

Land-Use Diagrams

HMR-SRD Historic Mixed Residential Special Review District

Zone DescriptionThe HMR-SRD district is designed to apply to existing neighborhood areas or portions of existing neighborhood areas which have been designated as an historic special review district because the buildings within reflect significant aspects of Tacoma’s early history, architecture and culture. Single-family dwellings are the predominant land use within the HMR-SRD district.

Above: a historic home as are common in this zone. Below: a recent two-family construction designed to reflect neigh-borhood character

R-2SRD Residential Special Review DistrictZone DescriptionThe R-2SRD district is very similar to the R-2 district, however it allows a limited number of two and three-family dwellings, subject to conditional use permitting. Some preexisting multi-family dwellings may also exist in this district.

Left: Larger lot single family. Below: a recent two-family construction designed to reflect neighborhood character

SINGLE-FAMILY ZONING SUMMARY

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf) Min. Small Lot Area (sf) Min. Standard lot width (ft) Min. Small lot width (ft) Max. Height (ft) Setback Front (ft) Setback Side (ft) Setback Rear (ft)

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf) Min. Small Lot Area (sf) Min. Standard lot width (ft) Min. Small lot width (ft) Max. Height (ft) Setback Front (ft) Setback Side (ft) Setback Rear (ft)

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

R-2SRDResidential SRDTMC13.06.100TMC13.06.100.C.5 5,0004,50050353520525

HMR-SRDHistoric Mixed SRD TMC13.06.100… TMC13.06.100.C.55,0004,50050353520525

SPECIAL REVIEW DISTRICT

35’

20’

25’5’

5’

Street

Alley

R-2SRD/HMR-SRD Building Envelope

DRAFT

Page 4: Zoning Reference Guide 2020 - Tacoma

R-4L Low-Density Multi-Family District

R-3 Two-Family DistrictZone DescriptionThe R-3 district is intended for one, two, and three family dwellings. Some lodging and boarding homes are also appropriate. The R-3 district is characterized by low residential traffic volumes and generally abuts more intense residential and commercial districts.

Zone DescriptionThe R-4-L district is intended for low-density multiple-family housing, retirement homes, and group living facilities. The R-4L district is very similar to the R-4 district, but has more restrictive site development standards which are intended to minimize adverse impacts of permitted and conditional uses on adjoining land.

Left: a two-family home built to mimic adjacent single-family. Below: A small lot development that provides more density and maintains street facing entrances

Left: two examples of Multi-family build-ings with unit entrances on the interior and congregate parking

MULTI-FAMILYZONING SUMMARY

Land-Use Diagrams

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

R-3 Two/three-family TMC13.06.100TMC13.06.100.C.55,0004,500503050%10352052530%

R-4LLow-density MFTMC13.06.100TMC13.06.100.C.55,0002,500502550%14352052530%

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf)Min. Small Lot Area (sf)Min. Standard lot width (ft)Min. Small lot width (ft)Bldg. Coverage (%)Min. Density (units/acre)Max. Height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Tree Canopy (%)

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf)Min. Small Lot Area (sf)Min. Standard lot width (ft)Min. Small lot width (ft)Bldg. Coverage (%)Min. Density (units/acre)Max. Height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Tree Canopy (%)

LOW-RISE RESIDENTIAL

Street

Street

R-3 and R-4L Building Envelope

35’25’

20’

No building on <50% of lot area

5’

5’

DRAFT

Page 5: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionThe R-4 district is intended for medium-density multiple-family housing. Other appropriate uses may include day care centers, and certain types of special needs housing. The R-4 district is located generally along major transportation corridors and between higher and lower intensity uses.

Zone DescriptionThe R-5 district is intended for high-density multiple family housing and also permits residential hotels, retirement homes, and limited mixed-use buildings. The district is generally located in the center of the city in close proximity to employment centers, conveniences, services, major transportation corridors, and public transportation facilities. Minor retail businesses such as drug stores, personal services such as beauty salons, and minor eating and drinking establishments are also permitted in the R-5 district.

Left: two examples of low rise multi-family buildings that are typical in the R-4 zoning

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is primarily in mixed-use zones

Land-Use Diagrams

R-5 Mult-Family District

R-4 Multi-Family District

MULTI-FAMILY ZONING SUMMARY

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

SPECIAL REVIEW DISTRICT

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf)Min. Small Lot Area (sf)Min. Standard lot width (ft)Min. Small lot width (ft)Bldg. Coverage (%)Min. Density (units/acre)Max. Height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Tree Canopy (%)

ZoneDescriptionCode SectionUseMin. Standard Lot Area (sf)Min. Small Lot Area (sf)Min. Standard lot width (ft)Min. Small lot width (ft)Bldg. Coverage (%)Min. Density (units/acre)Max. height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Tree Canopy (%)

R-4Multi-familyTMC13.06.100TMC13.06.100.C.55,0002,500502565%18601552520%

R-5 Dense multi-familyTMC13.06.100…TMC13.06.100.C.55,0002,500502565%221501052015%

60’

150’

25’

15’

10’

5’

5’ 5’

5’

StreetStreet

R-4 Building Envelope

R-5 Building Envelope

No building on <35%

of lot area

DRAFT

Page 6: Zoning Reference Guide 2020 - Tacoma

As described in the One Tacoma Comprehensive Plan This designation is characterized primarily by small-scale neighborhood businesses with some residential and institutional uses. Uses within these areas have low to moderate traffic generation, shorter operating hours, smaller buildings and sites, and less signage than general commercial or mixed-use areas. There is a greater emphasis on small businesses and development that is compatible with nearby, lower intensity residential areas.

Target Development Density: 14-36 dwelling units/acre

Intent of the General Community CommercialAs described in the One Tacoma Comprehensive Plan This designation encompasses areas for medium to high intensity commercial uses which serves a large community base with a broad range of larger scale uses. These areas also allow for a wide variety of residential development, community facilities, institutional uses, and some limited production and storage uses. These areas are generally located along major transportation corridors, often with reasonably direct access to a highway. This designation is characterized by larger-scale buildings, longer operating hours, and moderate to high traffic generation.

Target Development Density: 45–75 dwelling units/acre

Neighborhood Commercial Zones

General Community Commercial

COMMERCIAL ZONESR1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

DRAFT

Page 7: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionTransitional Districts are intended to serve as a transition between commercial or industrial areas and residential areas. The area is characterized by lower traffic generation, fewer operation hours, smaller scale buildings and less signage that general commercial areas. Permitted uses include small-scale office space, daycares, schools, parks, religious facilities, group housing, and retirement homes.

Zone DescriptionThe C-1 district contains low-intensity, smaller-scale land uses such as retail, office, and service uses. All uses permitted in the Transitional District are also permitted in the C-1 district with the addition of fueling stations. Building sizes are limited for compatibility with surrounding residential areas.

Left: A mix of commercial and residential typologies are found in the T Zone

Left:

Land-Use Diagrams

C-1 General Neighborhood Commercial

T Transitional District

COMMERCIAL ZONING SUMMARY

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

NEIGHBORHOOD COMMERCIAL DISTRICTS

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Maximum Floor Area (sf)Tree Canopy (%)

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Maximum Floor Area (sf)Tree Canopy (%)

TTransitional DistrictTMC13.06.200TMC13.06.200.C.5N/A or 1,500SF/res. unitN/A or R-4L for residential3500020,000SF30%

C-1Neighborhood Commer-cialTMC13.06.200TMC13.06.200.C.50N/A or R-4L for residential3500030,000SF30%

T Building Envelope

Street

Street

C-1 Building Envelope

35’

35’

DRAFT

Page 8: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionThe C-2 district is similar to the C-1 district however it is intended to serve a larger market area. Higher-intensity uses of the permitted uses in the C-1 district are allowed in the C-2 district.

Zone DescriptionPDB districts are intended to provide limited areas for a mix of land uses that include warehousing, distribution, light assembly, media, education, research, and limited commercial. Retail uses are size limited and signage is reduced. Sites in the PDB district should have reasonably direct access to a highway or major arterial.

Left: two examples of low rise multi-family buildings that are typical in the R-4 zoning

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is only in mixed-use zones

Land-Use Diagrams

PDB Planned Development Business

C-2 General Community Commercial

COMMERCIAL ZONING SUMMARY

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

GENERAL COMMERCIALDISTRICTS

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Maximum Floor Area (sf)Tree Canopy (%)

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Maximum Floor Area (sf)Tree Canopy (%)

C-2Community CommercialTMC13.06.200TMC13.06.200.C.50N/A or R-4 for residential4500045,000SF20%

PDBPlanned Development TMC13.06.200TMC13.06.200.C.50N/A or R-4 for residential450007,000SF20%

PDB Building Envelope

C-2 Building Envelope

Street

Street

45’

45’DRAFT

Page 9: Zoning Reference Guide 2020 - Tacoma

As described in the One Tacoma Comprehensive Plan This designation allows for a variety of industrial uses that are moderate in scale and impact, with lower noise, odors and traffic generation than heavy industrial uses. This designation may include various types of light manufacturing and warehousing and newer, clean and high-tech industries, along with commercial and some limited residential uses. These areas are often utilized as a buffer or transition between heavy industrial areas and less intensive commercial and/or residential areas.

Intent of the General Community CommercialAs described in the One Tacoma Comprehensive Plan This designation is characterized by higher levels of noise and odors, large-scale production, large buildings and sites, extended operating hours, and heavy truck traffic. This designation requires access to major transportation corridors, often including heavy haul truck routes and rail facilities. Commercial and institutional uses are limited and residential uses are generally prohibited.

Light Industrial

Heavy Industrial

INDUSTRIAL ZONESR1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

DRAFT

Page 10: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionM-1 Light Industrial District. This district is intended as a buffer between heavy industrial uses and less intensive commercial and or residential uses. M-1 districts may be established in new areas of the City. However, this classification is only appropriate inside Comprehensive Plan areas designated for medium and high intensity uses.

Left: two examples of low rise multi-family buildings that are typical in the R-4 zoning

Land-Use Diagrams

M-1 Light Industrial District

INDUSTRIAL ZONING SUMMARY

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Minimum Lot Width (ft)Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)

M-1 Light Industrial TMC 13.06.400… TMC 13.06.400.C.5 0 0 0 75 0 0 0

M-2, PMI Building Envelope

M-1 Building Envelope

Street

Street

75’

100’

LIGHT INDUSTRIAL

DRAFT

Page 11: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionM-2 Heavy Industrial District. This district is intended to allow most industrial uses. The impacts of these industrial uses include extended operating hours, heavy truck traffic, and higher levels of noise and odors. This classification is only appropriate inside Comprehensive Plan areas designated for medium and high intensity uses.

Zone DescriptionPMI Port Maritime & Industrial District. This district is intended to allow all industrial uses and uses that are not permitted in other districts, barring uses that are prohibited by City Charter. The Port of Tacoma facilities, facilities that support the Port’s operations, and other public and private maritime and industrial activities make up a majority of the uses in this

district. This area is characterized by proximity to deep water berthing; sufficient backup land

between the berths and public right-of-ways; 24-hour operations to accommodate regional and international shipping and distribution schedules; raw materials processing and manufacturing; uses which rely on the deep water berthing to transport raw materials for processing or manufacture, or transport of finished products; and freight mobility infrastructure, with the entire area served by road and rail corridors designed for large, heavy truck and rail loads.The PMI District is further characterized by heavy truck traffic and higher levels of noise and odors than found in other districts. The uses are primarily marine and industrial related, and include shipping terminals, which may often include container marshaling and inter-modal yards, chemical manufacturing and distribution, forest product operations (including shipping and wood and paper products manufacturing), warehousing and/or storage of cargo, and boat and/or ship building/repair. Retail and support uses primarily serve the area’s employees.Expansion beyond current PMI District boundaries should be considered carefully, as such expansion may decrease the distance between incompatible uses. Expansion should only be considered contiguous to the existing PMI District. This classification is only appropriate inside Comprehensive Plan areas designated for high intensity uses.

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is only in mixed-use zones

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is only in mixed-use zones

M-2 Heavy Industrial District

PMI Port Maritime & Industrial District

INDUSTRIAL ZONING SUMMARY

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Minimum Lot Width (ft)Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Minimum Lot Width (ft)Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)

M-2 Heavy Industrial TMC 13.06.400… TMC 13.06.400.C.5 0 0 0100000

PMI Heavy Industrial TMC 13.06.400… TMC 13.06.400.C.5 0 0 0100000

HEAVY INDUSTRIAL DISTRICTS

DRAFT

Page 12: Zoning Reference Guide 2020 - Tacoma

As described in the One Tacoma Comprehensive Plan The crossroads center is a concentration of commercial and/or institutional development that serves many nearby neighborhoods and generally includes a unique attraction that draws people from throughout the city. Some residential development may already be present, and there is a goal to have more residential development. It is directly accessible by arterials and local transit. Pedestrian accessibility is important within the center, but because of its focus on larger scale commercial development, the crossroads center continues to provide for automobile parking, preferably within structures.

Min. Allowable Development Density: 25 dwelling units/net acre

Intent of the General Community CommercialAs described in the One Tacoma Comprehensive Plan The neighborhood center is a concentrated mix of small- to medium-scale devel-opment that serves the daily needs of center residents, the immediate neighbor-hood, and areas beyond. Development contains a mix of residential and commer-cial uses, and the majority of parking is provided within structures. Buildings are generally up to six stories along the commercial corridors, up to three stories at the periphery of the centers near single-family districts, and up to four stories in areas between the core and the periphery. They are designed with a compatible charac-ter to adjacent residential neighborhoods. The design of the neighborhood center encourages pedestrians and bicyclists and its location on a major arterial makes it a convenient and frequent stop for local transit. The regional transit network also may directly serve some neighborhood centers.

Min. Allowable Development Density: 25 dwelling units/net acre

Intent of the General Community CommercialAs described in the One Tacoma Comprehensive Plan The Tacoma Mall is a highly dense self-sufficient concentration of urban develop-ment. Buildings can range from one to twelve stories and activity is greater than in most areas of the city. It is an area of regional attraction and a focus for both the local and regional transit systems. Many major city arterials connect to the Tacoma Mall Regional Growth Center and nearby freeway access is present. Parking is provided both in surface lots and within structures. Internal streets and pathways provide connections among the developments within the center.

Minimum Allowable Site Density: 25 dwelling units/net acre

Crossroads Center

Neighborhood Center

Tacoma Mall Regional Growth Center

MIXED-USE ZONESR1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

R1

R2, R2-SRD, HMR-SRD, R3, R4-L

R4

R5

T, C1

C2, PDB

NCX

CCX, RCX

UCX,CIX

HMX

URX

NRX

NRX

NRX

60’

150’

35’

45’

100’75’

35’

65’75’

150’

45’35’

45’

DRAFT

Page 13: Zoning Reference Guide 2020 - Tacoma

35’

60’

StreetStreet

NRX Building Envelope

RCX Building Envelope

Zone DescriptionNRX Neighborhood Residential Mixed-Use District. To provide for a predominantly residential neighborhood, to discourage removal of existing single-family residential structures; and to encourage in-fill residential development of appropriate size and design. This district is designed for areas characterized by an established mix of housing types and limited neighborhood commercial uses, in areas which were formerly zoned to permit residential development at densities greater than single-family, where redevelopment removed many existing single-dwelling structures and where there is continued development pressure that threatens single-family dwellings. Adaptive reuse of existing single-family detached structures as duplexes or triplexes is permitted with special review. Multiple-family dwellings in existence at the time of reclassification to NRX are

conforming uses.

Zone DescriptionRCX Residential Commercial Mixed-Use District. To provide sites for medium- and high-intensity residential development in centers, with opportunities for limited mixed use. This district is primarily residential in nature and provides housing density on the perimeter of more commercial mixed-use zones. Commercial uses in this district are small in scale and serve the immediate neighborhood. These uses provide opportunities for employment close to home. This district frequently provides a transition area to single-family neighborhoods.

Photos: two examples of low rise multi-family buildings that are typical in the R-4 zoning

NRX Neighborhood Residential Mixed-Use District

RCX Residential Commercial Mixed-Use District

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)

Maximum Floor Area (sf)

ZoneDescriptionCode SectionUseMinimum Lot Area (sf)

Maximum height (ft)Setbacks

CCX Community Commercial TMC13.06.300… TMC13.06.300.D 0 0 60 0 0 030; 40 on designated pedestrian streets. See Section 13.06.300.C45,000 square feet per business for retail uses, unless approved with a conditional use permit. See Section 13.06.640

NRX Neighborhood Residential TMC13.06.300… TMC13.06.300.D 3,500 square feet for single-family dwellings; 2,500 square feet per unit for duplexes; 6,000 square feet for triplexes and multi-family dwellings; 5,000 square feet total per townhouse development 25 feet for single-family dwellings, duplexes and triplexes; 14 feet for townhouses 35 For single, two- and three-family dwellings and townhouses: 10-foot front, 5-foot sides, 15-foot rear For other uses: 10-foot front, 7.5-foot sides, 20-foot rear See Section 13.06.503; residential transition standards may also apply.

MIXED-USEZONING SUMMARY

RESIDENTIAL MIXED-USE CENTER

DRAFT

Page 14: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionHMX Hospital Medical Mixed-Use District. This district is intended for limited areas that contain hospitals and/or similar large-scale medical facilities along with a dense mix of related and supportive uses, such as outpatient medical offices, care facilities, counseling and support services, medical equipment and support facilities, food and lodging. Residential uses are also appropriate. The district includes limitations on non-medical and non-related uses. It is not intended for introduction into areas not containing or non-contiguous to a hospital or similar facility. Walking and transit use is facilitated through designs which decrease walking distances and increase pedestrian safety. This classification is not appropriate inside Comprehensive Plan designated low-intensity areas.

Zone DescriptionURX Urban Residential Mixed-Use District. To provide sites for medium intensity residential development, such as townhouses, condos and apartments. This district is residential in nature and provides housing density in proximity to more

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is only in mixed-use zones

Above: not many examples of R-5 zone exist in Tacoma as mid to high-rise construction is only in mixed-use zones

HMX Hospital Medical Mixed-Use District

URX Urban Residential Mixed-Use District

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)Maximum Floor Area (sf)

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)Maximum Floor Area (sf)

HMX Hospital/Medical TMC13.06.300… TMC13.06.300.D 0 0 150 0 0 0 07,000 SF per busi-ness for eating and drinking, retail and personal services uses

URX Urban Residential TMC13.06.300… TMC13.06.300.D 0 0 45 0 0 0 0 0

MIXED-USE ZONING SUMMARY

150’

45’

StreetStreet

URX Building Envelope

HMX Building Envelope

RESIDENTIAL MIXED-USE CENTER

DRAFT

Page 15: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionCIX Commercial Industrial Mixed-Use District. To provide sites for a mix of commercial establishments and limited industrial activities, including light manufacturing, assembly, distribution, and storage of goods, but no raw materials processing or bulk handling. Larger scale buildings are appropriate. Residential uses are permitted.

CIX Commercial Industrial Mixed-Use District

CCX Commercial Industrial Mixed-Use District

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)Maximum Floor Area (sf)

CIX Commercial Industrial TMC13.06.300… TMC13.06.300.D 0 0 75 0 0 0 0 45,000 square feet per business for retail uses, unless approved with a conditional use permit. See Section 13.06.640

This document should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code and policy requirements, regardless of whether they are referred to or contained within this document

MIXED-USEZONING SUMMARY

60’

75’

StreetStreet

CCX/RCX Building Envelope

CIX Building Envelope

Zone DescriptionCCX Community Commercial Mixed-Use District. To provide for commercial and retail businesses intended to serve many nearby neighborhoods and draw people from through-out the City. These areas are envisioned as evolving from traditional suburban develop-ment to higher density urban districts. Walking and transit use are facilitated through designs which decrease walking distances and increase pedestrian safety. Uses include shopping cen-ters with a wide variety of commercial estab-lishments; commercial recreation; gas stations; and business, personal, and financial services. Residential uses are encouraged in CCX Districts as integrated development components.

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)

Maximum Floor Area (sf)

CCX Community Commercial TMC13.06.300… TMC13.06.300.D 0 0 60 0 0 030; 40 on designated pedestrian streets. See Section 13.06.300.C45,000 square feet per business for retail uses, unless approved with a conditional use permit. See Section 13.06.640

COMMERCIAL MIXED-USE CENTER

DRAFT

Page 16: Zoning Reference Guide 2020 - Tacoma

Zone DescriptionUCX Urban Center Mixed-Use District. To provide for dense concentration of residential, commer-cial, and institutional development, including re-gional shopping centers, supporting business and service uses, and other regional attractions. These centers are to hold the highest densities outside the Central Business District. An urban center is a focus for both regional and local transit systems. Walking and transit use is facilitated through designs which decrease walking distances and increase pedestrian safety. Residential uses are encouraged in UCX Districts as integrated development components.

Photos: two examples of low rise multi-family buildings that are typical in the R-4 zoning

UCX Urban Center Mixed-Use District

ZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)

Maximum Floor Area (sf)

CCX Community Commercial TMC13.06.300… TMC13.06.300.D 0 0 60 0 0 030; 40 on designated pedestrian streets. See Section 13.06.300.C45,000 square feet per business for retail uses, unless approved with a conditional use permit. See Section 13.06.640

Zone Description NCX Neighborhood Commercial Mixed-Use District. To provide areas primarily for immediate day-to-day convenience shopping and services at a scale that is compatible and in scale with the surrounding neighborhood, including local retail businesses, professional and business offices, and service establishments. This district is intended to enhance, stabilize, and preserve the unique character and scale of neighborhood centers and require, where appropriate, continuous retail frontages largely uninterrupted by driveways and parking facilities with street amenities and direct pedestrian access to the sidewalk and street. Residential uses are encouraged as integrated components in all development.

NCX Neighborhood Commercial Mixed-Use DistrictZoneDescriptionCode SectionUseMinimum Lot Area (sf) Bldg. Coverage (%)Maximum height (ft)

Setback Front (ft)Setback Side (ft)Setback Rear (ft)Min. Density (units/Acre)

Maximum Floor Area (sf)

NCX Neighborhood Commercial TMC13.06.300… TMC13.06.300.D 0 0 45 feet; 65 feet in the Stadium District of the DRGC 0 0 030; 40 on designated pedestrian streets. See Section 13.06.300.C30,000 square feet per business; 45,000 square feet for full service grocery stores only; offices shall be exempt from these limits.

75’

20’

45’

StreetStreet

NCX Building Envelope

UCX Building Envelope

NCX Building Envelopein Stadium District

MIXED-USE ZONING SUMMARY

COMMERCIAL MIXED-USE CENTER

DRAFT