Hub Industrial Supply Zinc Rich Cold Galvanizing Compound is a A high performance primer containing 97% pure zinc dust pigment blended with epoxy resin. Stops rust by electro-chemical action on steel or galvanized coatings. The self-sacrificing zinc protects the base metal, preserving strength and prevents rust creepage when the area is penetrated or scratched. This compound fuses zinc to the metal substrate and delivers protection against corrosion equal to or better than hot dipped galvanize. PRODUCT DATA Zinc Rich Cold Galvanizing Compound 065-017-015 PRODUCT DESCRIPTION USES For use in automotive, marine, nuclear facilities, power plants and refineries. • Industrial tanks • Piping • Welded joints • Bridges • Farm equipment • Fences • Wrought iron • Gutters • Structural steel • Transmission towers • Galvanized surfaces APPLICATION Must be applied directly to dry, clean metal or galvanized surfaces and not over any other paint or coating. Apply a heavy, wet coat to obtain proper thickness with no bare areas or pinholes. Double-lap spray all welds, corners, edges, etc. Im p o r t a n t : Do not contaminate with water or acid. Surface Preparation: Proper surface preparation contributes to maximum service life of coatings. All contaminates, millscale, rust, rust scale, chemicals, grease, oil, wax, eld spatter, old paint or other foreign matter must be removed down to bare metal. New Galvanized Metal: Oils, greases and waxes may be removed with mineral spirits or xylol. Stronger aromatic solvents such as xylol are recommended toremove silicone surface treatments. Silicates or white rust should be removed by sanding or sweep-blast. Do not use acetic acid or vinegar for surface preparation of galvanized metal. Keep surfaces moisture- free until coated with Zinc Rich Cold Galvanizing Compound. Spot reblast to remove any contamination-solvent wiping is not satisfactory. APPLICATION CONT . Previously Coated Surfaces: If coated surface has been scratched or penetrated to expose substrate, it should be treated as new galvanized metal. Previously coated surfaces in good condition should be treated to ensure a clean, dry surface, free of contaminants. Metal (iron or steel): Round off all rough welds, rivet heads and weld spatters. There are several methods of surface preparation depending upon the surface condition of the metal. Contaminants may be removed by wire brushing, chipping, scraping or sanding. If more effective cleaning is needed, power tools can be used. mil scale may be removed with acid. After treatment, surface must be rinsed thoroughly. Greases and other soluble materials can be removed with solvents such as mineral spirits, toluol and xyol, or by steam cleaning. If surface is particularly contaminated, several different methods of sand-blasting could be used. TECHNICAL DATA RESIN TYPE: Epoxy APPEARANCE: Medium Gray PROPELLANT: Hydrocarbon Blend SHEEN: Low Gloss % SOLIDS: 51.50% DRY FILM WEIGHT: ZINC DUST: 92.00% RESIN: 8.00% P IGMENT: Per ASTM D520, Type I 97% Zinc Dust WT./GAL.: 9.60 SPECIFIC GRAVITY: 1.16 HAZARD CODE: 2,2,1 V OC: 48.50% MIR: 0.81 OTC & CALIFORNIA COMPLIANT: Yes FLAMMABLE: Yes FLASH POINT: < 0°F RECOMMENDED FILM THICKNESS: 1 - 2.5 mils wet COVERAGE PER AEROSOL (THEORETICAL): 22 sq. ft. per can SHELF LIFE: 3 years from date of manufacture DRYING TIME @ 70°F @ 50%R.H. TO TOUCH: 10-15 minutes TO HANDLE: 1 hr. R ECOAT: 2 to 16 hrs. or after 36 hrs. CLEAN UP: Xylene SIZE: 16 oz. size can -14 oz. net wt. DIRECTIONS FOR USE • Remove all rust, scale, paint, grease or foreign matter. A good clean surface is necessary. Apply directly to DRY metal or galvanized surface and not over any other paint or coating. Product should be sprayed in a well ventilated area. Use at room temperature between 50°F (10°C) and 80°F (27°C) for best operation. • Turn can upside down. Hit sides lightly while rotating can in 1/ 4 turns until agitator ball breaks loose. • While holding can upright, alternately shake the can up and down and in a circle for 30-60 seconds until the agitator travels freely in the bottom. NOTE! INSUFFICIENT MIXING MAY CAUSE PRODUCT TO SETTLE AND PLUGGING TO OCCUR. • Press spray button firmly with the can 8” to 12” away from surface being coated. Move can with short dusting strokes, releasing button at the end of each stroke. Apply several thin coats. • For maximum performance in a highly corrosive environment, a topcoat is required. • To prevent clogging, hold can upside down and spray until only clear gas comes out.

Upload: others

Post on 16-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Zinc Rich Cold Galvanizing Compoundhub-cdn.s3.amazonaws.com/product-content/4/5/f/1/... · Galvanizing Compound is a A high performance primer containing 97%pure zinc dust pigment

Hub Industrial Supply Zinc Rich ColdGalvanizing Compound is a A highperformance primer containing 97% purezinc dust pigment blended with epoxyresin. Stops rust by electro- chemicalaction on steel or galvanized coatings.The self- sacrificing zinc protects the basemetal, preserving strength and preventsrust creepage when the area is penetratedor scratched. This compound fuses zinc tothe metal substrate and delivers protectionagainst corrosion equal to or better thanhot dipped galvanize.

PRODUCT DATA

Zinc RichCold Galvanizing Compound

065-017-015

PRODUCT DESCRIPTION

USES

For use in automotive, marine, nuclearfacilities, power plants and refineries.• Industrial tanks • Piping• Welded joints • Bridges• Farm equipment • Fences• Wrought iron • Gutters• Structural steel • Transmission towers• Galvanized surfaces

APPLICATION

Must be applied directly to dry, cleanmetal or galvanized surfaces and notover any other paint or coating. Apply aheavy, wet coat to obtain proper thicknesswith no bare areas or pinholes. Double- lapspray all welds, corners, edges, etc.Im por tan t : Do not contaminate withwater or acid.Su r face P reparat ion : Proper surfacepreparation contributes to maximumservice life of coatings. All contaminates,millscale, rust, rust scale, chemicals,grease, oil, wax, eld spatter, old paint orother foreign matter must be removeddown to bare metal.New Galvan ized Metal: Oils, greasesand waxes may be removed with mineralspirits or xylol. Stronger aromatic solventssuch as xylol are recommended toremovesilicone surface treatments. Silicates orwhite rust should be removed by sandingor sweep-blast. Do not use acetic acid orvinegar for surface preparation ofgalvanized metal. Keep surfaces moisture-free until coated with Zinc Rich Cold Galvanizing Compound. Spot reblast toremove any contamination-solvent wipingis not satisfactory.

APPLICATION CONT.P rev iou s ly Coated Su r faces :If coated surface has been scratched orpenetrated to expose substrate, it shouldbe treated as new galvanized metal.Previously coated surfaces in goodcondition should be treated to ensure aclean, dry surface, free of contaminants.Metal (iron or s teel): Round off allrough welds, rivet heads and weldspatters. There are several methods ofsurface preparation depending upon thesurface condition of the metal.Contaminants may be removed by wirebrushing, chipping, scraping or sanding.If more effective cleaning is needed, powertools can be used. mil scale may beremoved with acid. After treatment, surfacemust be rinsed thoroughly. Greases andother soluble materials can be removed withsolvents such as mineral spirits, toluol andxyol, or by steam cleaning. If surface isparticularly contaminated, several differentmethods of sand-blasting could be used.

TECHNICAL DATA

RESIN TYP E: EpoxyAP P EARANCE: Medium GrayP ROP ELLANT: Hydrocarbon BlendSHEEN: Low Gloss% SOL IDS: 51.50%DRY FILM WEIGHT:Z INC DUST: 92.00%RESIN: 8.00%P IGMENT: Per ASTM D520, Type I

97% Zinc DustWT./GAL.: 9.60SP ECIFIC GRAV ITY: 1.16HAZARD CODE: 2,2,1VOC: 48.50%MIR : 0.81OTC & CALIFORNIA COMPLIANT: YesFLAMMABLE: YesFLASH P OINT: < 0°FRECOMMENDED FILM THICKNESS:

1 - 2.5 mils wetCOVERAGE P ER AEROSOL

(THEORETICAL ): 22 sq. ft. per canSHELF L IFE: 3 years from date of

manufactureDRYING TIME @ 70°F @ 50% R.H.TO TOUCH: 10-15 minutesTO HANDLE: 1 hr.RECOAT: 2 to 16 hrs. or after 36 hrs.CLEAN UP : XyleneSIZE: 16 oz. size can -14 oz. net wt.

DIRECTIONS FOR USE

• Remove all rust, scale, paint, grease orforeign matter. A good clean surface isnecessary. Apply directly to DRY metalor galvanized surface and not over anyother paint or coating. Product shouldbe sprayed in a well ventilated area.Use at room temperature between 50°F(10°C) and 80°F (27°C) for bestoperation.

• Turn can upside down. Hit sides lightlywhile rotating can in 1⁄4 turns untilagitator ball breaks loose.

• While holding can upright, alternatelyshake the can up and down and in acircle for 30-60 seconds until theagitator travels freely in the bottom.

NOTE! INSUFFICIENT MIX ING MAYCAUSE P RODUCT TO SETTLE ANDP LUGGING TO OCCUR.• Press spray button firmly with the can 8”

to 12” away from surface being coated.Move can with short dusting strokes,releasing button at the end of eachstroke. Apply several thin coats.

• For maximum performance in a highlycorrosive environment, a topcoat isrequired.

• To prevent clogging, hold can upsidedown and spray until only clear gascomes out.

Page 2: Zinc Rich Cold Galvanizing Compoundhub-cdn.s3.amazonaws.com/product-content/4/5/f/1/... · Galvanizing Compound is a A high performance primer containing 97%pure zinc dust pigment

Hub Industrial SupplyP.O. Box 3609Lake City, FL 32056(800) 743-9401www.hubindustrialsupply.com

8/2017

Meets ASTM A780 - 09(2015) Yes• Highly resistant to salt corrosion and water• May be top-coated with conventional finish coats• Prevents rust creepage• Equal performance to hot dipped galvanize• Self- sacrificingDRY HEAT RESISTANCE: 400°F constant, 600°F intermittently

R ESISTANCE GUIDE

CHEMICAL RESISTANCE: Moderate Severe

Aliphat ic hy drocarbon solv en t s : XAlk alis : XArom at ic hy drocarbon solv en t s : XCh lor inated solv en t s : XSalt w ater : XGly col ethers , a lcohols : XInorgan ic acids : XOrgan ic acids : XOils : X

Resistance to fumes, splash and spillage; not immersion.