zenitsuite what’s new on version 2 · zenitsuite what’s new on version 2.0 part library...
TRANSCRIPT
ZenitSuite What’s new on Version 2.0
ZenitSuite 2.0www.zenitpcb.com
What’s new on Version 2.0
Copyright 2007,2016 Stortini Mirko Bruno.
This software is provided as-is, without any expressed or implied warranty.
In no event will the author be held liable for any consequences/damages arising from the use
of this software.
This program and the accompanied libraries are FREEWARE.
It may contain bugs, so use of this tool is at your own risk.
You can use it for personal, business, educational or any other need of yours, subject to the
following restrictions:
1. You may not re-distribute this program without contacting the author and
getting his consent.You may not charge any fee or re-distribution fee for it.
2. This notice may not be removed or altered from any distribution.
3. No form of decompilation / reverse engineering / disassembling parts or whole
of the software may be done.
4. You may not misrepresent the origin of the software/artwork.
If you are distributing the package and library, the files must be clearly indicated that they are part of ZenitPCB Layout software by Stortini Mirko Bruno.
1
ZenitSuite What’s new on Version 2.0
General indexZenitParts...................................................................................................................4 Pins Attribute............................................................................................................4 Part Library Attribute.................................................................................................5 Auto Open Part or Symbol..........................................................................................6 Auto increase pin length (F8)......................................................................................6 Symbol Library Description.........................................................................................7 Add Multi Overbar on Pin Name...................................................................................7
Overbar Examples..................................................................................................7ZenitCapture...............................................................................................................8 Explorer Overview.....................................................................................................8 Part Property............................................................................................................8
Part Not Verified.....................................................................................................9 Software Info.......................................................................................................11 Not Electrical Data................................................................................................11
Change Part Value...................................................................................................12 Sheet Number and Sheet Name.................................................................................12 Place Parts Form......................................................................................................14
Find Part on Libraries............................................................................................14 Last Part Placed...................................................................................................14
Rename Net............................................................................................................15 Auto-Rename Net....................................................................................................15 Align Wire Text & Note.............................................................................................16 Insert MultiText.......................................................................................................18 Align Parts..............................................................................................................19 Report Output.........................................................................................................20
Custom Report.....................................................................................................20 Software Data Report:..........................................................................................21 Not Electrical Data................................................................................................21
Report Option..........................................................................................................22 Print Schematic Sheets Option..................................................................................23 Other improvements................................................................................................24
Read Only Project.................................................................................................24 Change Sheet......................................................................................................24 Text Origin..........................................................................................................24 Bug Fix...............................................................................................................24
ZenitPCB...................................................................................................................25 Print Alternative Text................................................................................................25
2
ZenitSuite What’s new on Version 2.0
ZenitParts
Pins Attribute
It is now possible to insert the pin names, directly inside a grid, copy and paste, so as to avoid tedious, single manual inputs.
Moreover, in "Pins Attribute" you can change other attributes as "electrical type" and "Inside & Outside Edge".
Video: Pins Attribute
3
ZenitSuite What’s new on Version 2.0
Part Library Attribute
With part library, is possible to displays all the attributes of a library in spreadsheet format.
This allows you, in a single environment, to change all the attributes you want, for example the cost, without having to open one by one each parts.
You can filter your search, to display only the affected components.
4
ZenitSuite What’s new on Version 2.0
Auto Open Part or Symbol
On ZenitCapture, it is now possible to open directly on ZenitParts the selected symbol or part, to eventually modify it.
Auto increase pin length (F8)
It is now possible to increase the selected pin length by F8 key, without open pin property.
I remember you, that it is possible to do the same thinks for Electrical Type (F9) and
Type (F10) .
5
F8 F8
ZenitSuite What’s new on Version 2.0
Symbol Library Description
The symbol library now, has the possibility to insert a description, to better understand the library itself.
Add Multi Overbar on Pin Name
It is now possible to insert OverBar on the pin text name only on a specific position, by the wildcard character (!)
Overbar Examples
!MCLR
GP3/!MC
P60/!SCK00!/SCL00
P54/TI11/TO11/!SSI10
6
ZenitSuite What’s new on Version 2.0
ZenitCapture
Explorer Overview
New Items on explorer overview, that list all unverified parts.
Part Property
New on “Part Properties” :
7
Report Part like a non electrical component, e.g. Labels,Screw,heat sink...
Soft
ware
In f
o
Par t
No t
ye t
ver
ifie
d an
d N
o te
ZenitSuite What’s new on Version 2.0
Part Not Verified
When we are drawing a part of the circuit, often values of the components are indicative, and only later, adjusted to the correct value. This is true both for the value, which for the footprint.
So it is helpful to know which parts are not yet defined, displaying them on the explorer bar, which allows you to jump from one component to another.
This avoids unnecessary artifices on schematic workspace, to add shape like circles on the parts or add single text near the unverified part.
Consider a schematic with 300 or more parts and you will understand that they are really hard to find.
The program also warning you if you have not checked components, when you try to create reports or export netlist. With double click on the grid, you can zoom around the part not verified.
8
ZenitSuite What’s new on Version 2.0
Software Info
Now is possible to store software data info, inside the part (e.g. microprocessor).
Of course, more lines are available, to store more software info.
Software Data Report:
List all software detail on the report. Really useful, because in a single document, you also have the software code and software-part matching.
Obviously, the source code of the micro is not stored, inside part!→
Not Electrical Data
Now you can specify whether the component is part of the assembly bom (pick & place), or a subsequent assembly, to complete the product (screws, housing, wiring, labels and so on)
On Report:
List all parts “not electrical”, that are mounted after PCBA assembly.
You can see that on the description part there is the owner part (e.g. E1)
9
ZenitSuite What’s new on Version 2.0
Change Part Value
On the fly, is possible to change the part value, without open the part property.
You have to fill the combo box whit a value e.g. 100K and than "Active change Part Value". Click on every part that you want to change. The combo box shows the latest values inserted.
Sheet Number and Sheet Name
Added New Field Texts : Sheet Number
Report the sheet number on workspace.Every time you change sheet pagethis number change.
Sheet NameReport the sheet name on workspace.Every time you change sheet pagethis text change.
10
Combo Box Value | Activate Command “Change Value”
ZenitSuite What’s new on Version 2.0
Place Parts Form
There are also new developments on the dialog box "Parts Place"
Find Part on Libraries
On “Place Part” form, you can find a specific part that match the filter criteria.
Last Part Placed
To speed up the placement of the parts, in the "Place Parts" is present the combobox "Last Part Placed" tab, which shows the last placed parts. You can choose one of them and place it, again.This avoid to waste time on looking for the library and the part itself, of an already placed part.
11
ZenitSuite What’s new on Version 2.0
Rename Net
If you decide to rename a net, the system will ask you if you just want to rename the selected branch or the whole net.
Auto-Rename Net
With this command, you can rename the nets automatically. Just set the name of the net (prefix) and the number of auto increment. Now as soon as you click in a net, it will be changed to the new name (e.g., PD1, PD2...)
Align Wire Text & Note
You can align the "Wire Name Text" with the "Align" command, after selecting the texts.
12
ZenitSuite What’s new on Version 2.0
Insert MultiText
Multi-Text lines, is a text editor (ASCII),with the possibility to set some properties like justification, colors, angle and background shape.
MultiText examples:
13
Text Properties
Text Distance
Text Angle Shape Brush Properties
Shape Border Line Properties
ZenitSuite What’s new on Version 2.0
Align Parts
Is possible to align parts to the same axis. This command also, involve the wire nets.
14
ZenitSuite What’s new on Version 2.0
Report Output
Custom Report
Redesign the Report Output Form. Now is possible to save and open user reports.
Is possible to filter reports, from SMT, PTH, MIXED and DOC Parts.
Like an options, you can insert at the end of the report, a section with “Not Electrical Part Data” like screws, housing, wiring, labels and so on, or a software section with part software data.
15
Generate the report
Save the report into ASCII file
Report column structure | Part Property| Header Text | n.Char
Choose Text Data Delimiter
Choose User Report Type
Sort Bill of Material Report
Filter Report PartInclude or not, these types of parts to the report.
e.g. Parts included inside part E1
Save Report Format to the default directory
ZenitSuite What’s new on Version 2.0
Software Data Report:
List all software detail on the report. Really useful, because in a single document, you also have the software code and software-part matching.
Obviously, the source code of the micro is not stored, inside part!→
Not Electrical Data
Now you can specify whether the component is part of the assembly bom (pick & place), or a subsequent assembly, to complete the product (screws, housing, wiring, labels and so on)
On Report:
List all parts “not electrical”, that are mounted after PCBA assembly.
You can see that on the description part there is the owner part (e.g. E1)
16
ZenitSuite What’s new on Version 2.0
Report Option
Header text properties Report
17
ZenitSuite What’s new on Version 2.0
Print Schematic Sheets Option
Is possible to print the schematic with the “Alternative Text Output”, that convert the vectorial text with True type Font. In this way you can create text in pdf files, for example.
In addition you can also print “All to Black”.
18
ZenitSuite What’s new on Version 2.0
Other improvements
Read Only Project
Lock the project when it is already open.
Change Sheet
To switch pages, you can use the sheet combo box,or the keys PageUp and PageDown.
Text Origin
When select Text or Multitext, the origin will be showed.
Bug Fix
Undo No Text\IEEE\Field Rotate
19
ZenitSuite What’s new on Version 2.0
ZenitPCB
Print Alternative Text
Is possible to print the pcb layout, with the “Alternative Text Output”, that convert the vectorial text with True type Font. In this way you can create text in pdf files, for example.
Thanks
Mirko Bruno Stortini
20